09-925-012PLUI" 51NG GENERAL NOTES AND SPECIFICATIONS: 1. A. SCOPE OF WORK: THE WORK SHALL INCLUDE ALL PLUMBING NECESSARY SHOWN ON THE DRAWINGS, SPECIFIED HEREIN AND /OR AS NEEDED FOR A COMPLETE SYSTEM, INCLUDING BUT NOT NECESSARILY LIMITED TO: I. DOMESTIC COLD AND HOT WATER PIPING SYSTEMS 2. SANITARY DRAIN AND VENT SYSTEMS 3. PLUMBING FIXTURES AND TRIM 4. AIR CONDITIONING CONDENSATE DRAINS 5. PRESSURE AND TEMPERATURE RELIEF FROM WATER HEATER 6. PIPING INSULATION 1. SUPPORTS AND HANGERS B. ALL PLUMBING WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST EDITION OF THE "FLORIDA BUILDING CODE" 2001 LOCAL ORDINANCES AND IN COMPLIANCE WITH THE "FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION ", AND "HRS" REGULATIONS. IN THE EVENT OF CONFLICT BETWEEN ANY CODE OR REGULATIONS, THE MORE STRINGENT REQUIREMENTS WILL GOVERN. 2. CONTRACTOR TO VERIFY AT SITE THE LOCATION, ELEVATION AND SIZE OF ALL EXISTING LINES FOR CONNECTION BEFORE INSTALLATION OF ANY PIPING. 3. UNDERGROUND METAL PIPING SHALL BE PROTECTED WITH A COAT OF BITUMINOUS ,COMPOUND BEFORE COVERING 4. ALL FIXTURES SHALL BE PROTECTED AGAINST WATER HAMMER WITH AIR CHAMBERS OR SHOCK ABSORBERS AS INDICATED ON PLANS, 5. ALL FLOOR DRAINS TO HAVE TRAP PRIMERS 1/2" LINE FROM THE NEAREST PLUMBING FIXTURE. Co. PLUMBING FIXTURES SHALL BE CONSTRUCTED WITH THE APPROVED MATERIALS, SHALL HAVE SMOOTH IMPERVIOUS SURFACES AND SHALL BE FREE FROM DEFECTS AND CONCEALED FOULING SURFACES. ALL FIXTURE TRIM TO BE CHROME PLATED. FIXTURES SHALL BE PROVIDED WITH SUPPORTS, HANGERS, ETC. 1. UNDERGROUND WASTE LINES ABOVE 2 "TO BE PVC SCH. 40 AND SLOPE s 1/811/ FT. WASTE LINES 2" AND UNDER, AND ABOVE GROUND PIPES SLOPE 0 1 /4 "/FT. 8. PROVIDE FULLY ACCESSIBLE CLEAN OUTS ON SANITARY AND ANY WASTE PIPING AT EVERY CHANGE OF DIRECTION, AND AT BOTTOM OF STACKS. CLEAN OUT LOCATIONS AND SIZES ON HORIZONTAL LINES SHALL BE ACCORDING TO CODE. S. VENT LINES TO EXTEND 9" MIN. ABOVE ROOF AND FLASH. 10. WATER PIPE BELOW GROUND SHALL BE COPPER TYPE "K" ABOVE GROUND TO BE COPPER TYPE "L" OR "M ". OR APPROVED CPVC . NO JOINTS ALLOWED UNDER SLAB. 11. PIPING A. SUPPORT ALL PIPE FROM SOUND PORTIONS O- STRUCTURE AND AT PROPER INTERVALS ACCORDING WITH CODE. B. PROVIDE SLEEVES FOR ALL PIPING PASSING THROUGH FOUNDATION SLABS OR MASONRY WALLS, CAULK OPENINGS BETWEEN PIPE AND SLEEVES, C. WHERE EXPOSED PIPES PASS THROUGH FLOORS, WALLS, OR CEILINGS, PROVIDE ESCUTCHEONS FIRMLY SECURED TO THE PIPES AND OF SUFFICIENT OUTSIDE DIAMETER TO COVER THE SLEEVED OPENINGS FOR THE PIPES. PROVIDE CHROMIUM PLATED ESCUTCHEONS IN BATHROOMS. 12. INSPECTIONS AND TESTS A. CONTRACTOR SHALL BE RESPONSIBLE TO ASK FOR INSPECTIONS TO THE AUTHORITIES HAVING JURISDICTION, AS THE WORK PROGRESSES. ALL SYSTEMS SHALL BE TESTED BY CODE AND /OR LOCAL REGULATIONS. B. DRAINAGE PIPING: BEFORE INSTALLATION OF ANY DRAINS, THE ENDS OF SYSTEMS SHALL BE CAPPED AND ALL LINES FILLED WITH THE WATER TO THE HIGHEST POINT AND ALLOWED TO STAND UNTIL INSPECTION IS MADE BY AN OWNER REPRESENTATIVE. 13, STERILIZE ALL WATER LINES WITH A MIXTURE OF TWO (2) POUNDS OF CHLORINATED LIME TO EACH 1000 GALLONS OF WATER (50 PPM OF AVAILABLE CHLORINE) RETAIN MIXTURE IN PIPES 24 HOURS AND FLUSH THOROUGHLY WITH POTABLE WATER BEFORE PLACING IN SERVICE. 14, COMPLETE SYSTEM, FIXTURES AND EQUIPMENT SHALL BE GIVEN AN IN- SERVICE TEST AFTER COMPLETION OF THE INSTALLATION. FLU 51NG 4 PIPING LEGEND C /— RATED CAP MUL EXI s;DISIDENSATE DRAM C &MCTOR (D nN Dt"WOM SHALL DE AS PWZM04MW BY TFE AIR HANMM3 WIT MAN AGUPM (b THL PLWMMCi C WRACTOR SHALL COO M"M UM 11-E hEC"iCAL COW ACTOR TO BdE M T"T TH1:RE U LL W SUMCWff CLEAR CE Off= EH TM ORAM AND THS MOM CONNECT TO AIR HA%VLMG UW CRAM. PLUI" 15ING FIXTURE SCHEDULE RAIN WATER LEADER TRAP SIZE UNI ❑N CONNECTION ® ROOF DRAIN —It-- FLANGED CONNECTION 3 FLOOR DRAIN G7 —' ECCENTRIC REDUCER ❑ AREA BASIN ---f� = CONCENTRIC REDUCER Q CATCH BASIN 2 FIRE DEPARTMENT SIAMESE CONNECTION --�� HOSE BIBB W /VACUUM BREAKER U) ROOF MANIFOLD Q PENDANT TYPE SPRINKLER HEAR OF 11/4" —� SIDEWALL SPRINKLER HEAD 1/2" BASKET STRAINER —D4— GATE VALVE — 'Y' STRAINER — BALANCING PLUG I I I ANGLE VALVE —{�-- OS t Y VALVE FLOAT VALVE —�.i -- CHECK VALVE(NON -SLAM) _ --�— FLEXIBLE CONNECTIUN(I2 PIPE DIAMETERS PRESSURE & TEMPERATURE RELIEF VALVE UP TO 24' MAX.) BALL VALVE FLOOR CLEAN -OUT BUTTERFLY VALVE/ AGA APP. GAS VALVE FLOOR CLEAN-OUT —0 ;' HW SHUT -OFF VALVE �- -� WALL CLEAN -OUT CW SHUT -OFF VALVE —► DIRECTION OF FLOW 1 BUILDING SANITARY DRAIN OR SEWER A/C j AIR CONDITIONING CONDENSATE DRAIN i — COLD WATER LINE HOT WATER LINE HOT WATER RECIRCULATION LINE F FIRE LINE G GAS LINE(NATURAL OR LIP) SANITARY VENT LINE SD STORM DRAIN C /— RATED CAP MUL EXI s;DISIDENSATE DRAM C &MCTOR (D nN Dt"WOM SHALL DE AS PWZM04MW BY TFE AIR HANMM3 WIT MAN AGUPM (b THL PLWMMCi C WRACTOR SHALL COO M"M UM 11-E hEC"iCAL COW ACTOR TO BdE M T"T TH1:RE U LL W SUMCWff CLEAR CE Off= EH TM ORAM AND THS MOM CONNECT TO AIR HA%VLMG UW CRAM. PLUI" 15ING FIXTURE SCHEDULE MAW TRAP SIZE FIXTURE UNITS NOT WATER COLD WATER WC 3" 3 — 1/211 LAV 11/2" 1 - -- 1/2" MSK 2" 2 f /2" V2 It N U) Miami, Fiorillo 33155 En'" zo OF 11/4" a - 1/2" CAP 0007612 F_r I I I 1) FIXTURES TO COMPLY W/FBC 2001 Plumbing Sections 406 -421, 603.1 t 6043 t.4 601.1 Z, .21 3, t 109.1, AND MIAMI -DARE WATER -USE EF�ICIiRe-Y STANDARDS MANUAL 2) ANTI -SCALD VALVE: ALL SHOWERS t BATH /SHOWER COMBINATIONS SHALL BE PROTECTED WITH A CONTROL VALVE OF THE PRESSURE BALANCE, THERMOSTSTIC MIXING OR COM- BINATION TYPE SET. HANDLE POSITION STOPS PER MANUFACTURERS INSTRUCTIONS AT TIME OF INSTALLATION TO A MAXIMUM MIXED WATER OUTLET TEMPERATURE OF 120' -. s n a .yoil # r MM '1 MR, CLEANDUT DETAILS N,T.B. f e;f i . JOB t: 09 -1 OS [,_1 LaDON co, t!1 O. N d' W C GUERRERO /GONZALEZ t~!1 r.. tr'1 lift ENGINEERS, INC. LL�� // Michoel C. Guerrero, P.E. k Mechonicl EM Lk— /15235 n Wool L Gonzolez. P.E. . Uc. #11057 _Q Q SE�ric°1C�F.n N U) Miami, Fiorillo 33155 En'" zo Tel. (305 262 -3944. Fauc 305) 262 -8211 ..'- C� o! CL 7) E EC,SOGUERR ENgNEERS.COM CAP 0007612 [,_1 LaDON co, t!1 O. N d' W C iNV f.>Nt0 t~!1 r.. tr'1 lift ON LL�� ~ N yEnLn Mmes in in O n _Q Q N U) 0WO En'" zo W� C� o! CL 7) 1 a� C3 ID N W } 0' f-- Ld w Q v} cv W 5 `r' cv 3: 00 m 0 W 3: L F— U" _ rr Q �00 c (/) F— Z W m- W > z O -' LIJ � w W � w �_j W l C14 O 60 Cr1 O _ L0 �-' W q as O N 1