10-511-002m FUEL UTILIZATION RATE 24' 24' THE TIER 1 PAIN 1 SPRAY BOOTH INCORPORATES A PROPANE ' 1 1 1 /4„ -- GAS 'DIRECT FIRFD HEATER' THAT IS AN INTEGRAL PART OF 5 THE_ PAINT BOOTH CABIN AND THE PAINT /BAKE CYCLE 13, -3„ 3'--3" b' -6 1 4" 1,3 -6 5/8 " -- HEAT INPUT_ 997000 BTU /HR. FUEL: PROPANE GAS HEAT VALUE: .839 MILLION BTU /I`ACF AT 150% EFFICIENCY 997000 X 10 -" MILLION BTU /HR FUEL UTILIZATION: .E39 MILLION BTL'rMCF zmm — NOTES: BAKE CYCLE: X20 MIN PER VEHICLE r GAS FIRING: <10 MIN. PER VEHICLE I i� - FRESH PRODUCTS: -- i� .PAINTS, RE:- DUCERS & OTHER PAINTING RELATED PRODUCTS ARE STORED IN THE PAINT MIX ROOM IN ORIGINAL 1- GALLON AND 1 -QUART 4„ W -10 1/8" 4' N CONTAINERS. M in -- - - - -- -- - - - - -- w - -_- *SOLVENTS ARE STORED WITHIN A SECONDARY a I CONTAINMENT. IN A 55- GALLON STEEL DRUM. n _ CD ri r WASTES: _ •WAS -Tk PF.INTS & SOLVE NIS ARL STORED �1 WITHIN A SECONDARY CONNTAINMENT, IN A 30- GALLON ©- STL:F,L DRUM. i CO .A LICENSED HAULER WILL PICK UP WASTES FOR J PROPER DISPOSAL. (D - M - - - - -. - -.... GARMAT 49935 (MOD.) *WASTE CONTAINFRS SHALL BE GROUNDED PAINT MIXING ROOM - — - .WASTE CONTAINERS SHALL BE UL LISTED OR OF EXISTING (W/ BUILT -IN GARMA-( 4210 ;x \ APPOVED TYPE. CO TA I N M E N T TH R E SH O L -- -- - --- -- / / r-9 ACC U D RAFT Z %' TIER 1 0 �✓ SPILL CONTAINMENT AREA CALCULATIONS: - - ® I *MODEL 1620 DRUM SPILL. CON TAINME-IN T SPRAY BOOTH ij SPRAY B001-H 51" X 26° X 15" = 20.275 5 CU IN (AC-fUAL) — -- - - - - -— - - -- - -- I R LINE N CONNEC N 55 GALLON DRUM = 13,659 CU IN X 110 % = 15,025 10 6 1 /4" _ _— - -� INTO R01 CU. IN. (RE:�UIRED) PANE I... TIER 1 PAINT SPRAY BOOTH EQUIPMENT WEIGHT LINE TIER 1 PAINT SPRAY BOOTH: 9,900 LBS INTO lf_) THRESHOLD BOOTH ( FRONT AND REAR OF THE BOOTH) 00 1T6 5/8" X 2 - 2" 1 1/4" (27,104', EXISTING � THRESHOLD WIDTH = 25" AIRLINES 27.104'X 12 - 324.104 LINEAR INCHES 324.104" X 2.5" = 810 -26 SQ. INCHES 3,267 LBS. / 810.26 SO INCHES - 4 -032 LBS / SQ INCH _ SIDE WALLS_ / ( LEFT AND RIGHT OF THE BOOTIE 2T2 1/4" X 2 = 54'4 112" (54 375'8 P.M.R. HAS CONTINUOUS SPILL CONTAINMENT SIDE WALL WID,H - 3" THRESHOLD. P.M.R. HOLDS SEALED GAL. AND 54.375 X 12 = 652.50 LINEAR INCHES 652.50" X 3" = 1957.5 SQ INCHES QUART PAINT CANS. SEALED CANS ARE STORED 6 633 LBS./1957.50 SQ. INCHES = 3.389 LBS,/SQ. INCH 2 IN PAINT MIXING SYSTEM. ( THERE WILL BE THE EXISTING CONCRETE SLAB IN THIS BUILDINGS IS 6" THICK AND APPROX. 42 QUARTS AND 8 GALLONS STORED IN 3000 PSI PER rHE ORIGINAL CONSTRUCTION DOCUMENTS, Ln THE P.M.R ") 3000!4.032 = 5 F OF 744.05 3000/3.389 = S.H. OF n85.22 ALLOW AN ADEQUATE CLEARANCE OF 3' MIN. FROM ALL I EAGLE FM -1947 FxPLOSION -PROOF HAZARDOUS STORAGE CABINET. ADDITIONAL. NOTES: SPARKING ELECTRICAL COMPONENTS. TO CONFORM 45 GAL. CAPACITY ( MEETS TO NFPA 33, 2000 ED., SECTION 4.3 ( TYPICAL FOR O.S.H.A. REQUIREMENTS, THE GARMAT EQUIPMENT IS MANUFACTURED TIN ENGLEWOOD, COLORADO. PAIINT SPRAY BOOTHS AND PAINT MIIX ROOM.) THE GARMAT F.DUIPMEN I IS E I L LIS I ED CLEANER-, THE STRUCTURAL COMPONENTS ARE MADE OF 16 GAUGE STEEL. THE NON STRU C7 URAL W- I ALL PANELS ARE MADE OF 1 LAYER -- - SCOPE OF WORK: INSTALLATION OF (1) 271 r Of 11 GLAGE S1ELL RETENTION AREA LIP - s i LEL COMPONENTS ARE POWDERED COA EEO. NEW (�ARMAT 42106X TIER 1 SPRAY BOOTI M*ND 55 GAL N1;IJIMLWJNILLOA�REQ °IREME�I TSOR�Ff3° DO�YWIT "T "E ( 1) NEW GARMAT PAINT MIX ROOM I I EAGLE MODEL x`1620 DRUM -THE GARMAT EQUIPMENT IS SHIPPED IN CRATES FOR SPILL CONTAINMENT ASSEMBLY ON SITE. u EXISTING COMMERCIAL, C.B.S. BUILDING, CURRENTLY DOING BUSINESS AS A BODY SHO NOTE: BUILDING HAS EXISTING COMPRESSOR AND AIRLINE SYSTEM. NOTE: BUILDING DOES NOT HAVE FIRE SUPPRESSION SYSTEM. BOOTH WILL BE PROTECTED WITH ITS OWN FIRE SUPPRESSION SYSTEM. 0 0 9 a, BUILDING PLAN VIEW 1/411 - 1' -"-0" ,4'-3" X 2' -3" X 6') \ 55 GAL... WASTE D R U M/� MODEL 27'42106 TIER 1 INTAKE - 2) NIC 630937W ADH 355 G1_2 TWIN AXIAL FAN W/ (1 BALDOR M37 10T 7.5HP MOTOR- RATED AT 1,760 RPM FAN DIAMETER: 14 " /C. F, M. @ 0.5 S.P. 11,000 TO "4,000 EXHAUST- (1) NIC 632N49W RDH 450K EX FAN ( OIL SHAFT) Wi ('j BALDOR FM3710T 7.5 HP MOTOP, - RATED 1,760 R.P.M. FAN DIAMETLR: 17 384" C.F.M. (c� 0.5 S.P. 11,000 MODEL INTERIOR EXTERIOR EXHAUST FILTER SURFACE AREA 27' 42'.06 75 SO. F 1. HEGHT 8' 10 1/4" 12'4" LFNGTH 26'9 1/8" 27' 2 114 W I L'TH 13'1 1/2" 1T6 5/8" CROSS- SECTIONAL AREA 1'5 SO. FT. (40 16 SO. FT., a' - RAYS 5E 1/2" X 23 3 B" T-iF GARMAT iILP 1 IS EQUIPPLD'VVI i -i A PHOI OHFHC GAUGE. I HE NORMAL FACTORY RECOIe VENDED OPLRATING RANGE 13.01 ­03 INCHES WATER COLUMN. THE PHOTOHELIC GAUGE 'ADJUSTS' DAMPERS TO COMPENSATE FOR EXHAUST FILTER LOADING AND CA% 3k USED AS AN INDICATOR FOR WHEN FILTERS NEED CHANGING I.E. WHLN BOOi H �3AN NO LONGER ADJUST FOR LOADING. NOTE: ALL EQUPMENT COMLS STANDARD WIT F1 ADJUSTABLE SHEAVES FOR CON I ROLLING =AN SPEE _)S, AMP LOADS AND C.F.M. ADJUSTMENT. THEREFOPE, C.F.M. CAN BE CHANCED -ADJUS I ED FOR DIFFERENT STATIC PRESSURE LOSS CAUSED BY DIFFERENT DU;T SITUATICNS, 49935 PAIN- Nl1X ROOM EXiAL� ST - (1) DAYTON 40659 TUBE AXIAL FAN Il (' DAYTON 514191 1 /4HP MOTOR - RATED AT 1,725 RPM =Aa DIAMETER: 12 " /CFM (i C.25 S.P. 1,100 N7A4E - 20" X 20" CEILING __IL I ER MODEL INTERIOR EXTERIOR EXHAUST FILTER SURFACE AREA 49935 PAINT P,'IX ROOM N/A HEIG -- T6 3' 8" LENG-T 11'4 11' 1C'' ',','D7- 9' 10" 1 �' 2" NOTE: A' -L GA- tWl PAINT MIX ROOVS ,NILL BE LESS THAN 15 SQ. FT. i- PROGRESS ROAD SITE PLAN -T NOT TO SCALE EX1,S1 ING BUILDING NOFES BUILDING SOUARE FOOTAGE: 6630 S.F. E. -XI'. I ING BL)II..DING HE:IGI-iT: 18' ( APPROXIMATE) EXISTING BUILDING TYPE 'I -STORY C -B -S. CONSTRUCTION THIS PROJECT HAS BEEN DESIGNED AND SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE FOLLOWING APPI- ICABL.F BUILDING CODES: FLORIDA BUILDING CODE, EXISTING BUILDING ( FBC -EB) ( 2007 EDITION W/ 2009 SUPPLIMENTS) FLORIDA BUILDING CODE, BUILDING ( FBC -B) ( 2007 EDITION W/ 2009 SUPPLIMENTS) FLORIDA BUILIDNG CODE, MECHANICAL ( FBC -M) ( 2007 EDITION W/ 2009 SUPPLIMENTS) FLORIDA BUILDING CODE, FUEL GAS ( FBC -FG) ( 2007 EDITION W/ 2009 SUPPLIMENTS) FLORIDA BUILDING CODE, PLUMBING ( FBC -P) ( 2007 EDITION W/ 2009 SUPPLIMENTS) FLORIDA FIRE PREVENTION CODE (FFPQ ( 2004 EDITION) NATIONAL ELECTRIC CODE ( NEC) ( 2005 EDITION) NOTE: ALL ELECTRICAL TO COMPLY WITH CLASS 1/ DIVISION 2 AS PER NFPA 33. t , �� ♦ � ,4 �. I V / �I L� LL_LJ �J7 LL O x W r7 U) W 0 c� M 00 n LL_ a LL ^ 00 F, < Ln SEAL A. rE DRAWN N.B.S. CHECKED PL DATE 3/26/2010 JOB No. CAD No. MECHANICAL SHEET m - I 0 F 2 rn N O Ijr� r) C 7 r) � < 71- C � H O (I') F CJ w = O F- � r c,D _D w co r (J) � (V �= i ¢ � a I 01) = V) C:) 0 O K 2 J N D' 07 O Fo O ,n - S m SEAL A. rE DRAWN N.B.S. CHECKED PL DATE 3/26/2010 JOB No. CAD No. MECHANICAL SHEET m - I 0 F 2