FIN. FLR.
SECTION VIEW
FOR
CLARITY.
NOTE: ALL DRRAIN PIPING UNDER SLAB SHALL BE 2" MIN
2" E LESS PIA DRAIN 'w 1/4" DROP
3" 4 4" DIA DRAIN m 1 /8" DROP
WALL
"zURN"
"ZN- 1400- 5P -T -VP
FLOOR CLEANOUT.
FACE OF WALL.
STAINLESS STEEL COVER
SCREWED TO THREADED
C.O. PLUG.
"ZURN" OZ-1446-15P-VP
FOR EXPOSED BLOC<
AND GYPSUM BOARD
WALLS. "ZURN"
MZN- 144 -1-510-VP FPR TILE
WALLS. "zURN"
"ZN- 1448 -5P -VP FOR
PLASTER WALLS.
CONCRETE PAD "ZURN" "Z- 1404- VPIRON
2'x2'x8" W/ 4" 3EW. BOX W/ COVER MARKED
"CO..
FIN. GRADE
COMPACTED
FILL
ELEVATION VIE
TWO -WAY CLEANOUT TEE
OR LONG SWEEP QUARTER
BEND.
NOTE: REFER TO SPECIFICATIONS FOR
MATERIALS
AND REQUIREMENTS FOR INSTALLATION.
CLEANOUT DE TA I L S N.T.S.
SAND OR GRASS LEVEL
TIE DOWN C
Z" ANCHOR
10" CONCR
FILL VOIDS W/
OILED SAND.
CLEANOUT
FITTING W/
BRASS PLUG.
GROUND
WET SEASON WATER TABLE
UNSATISFACTORY
UNSATISFACTORY
SOIL
SOIL /WATER TABLE SITE
EVALUATION CRITERIA NTS
"GUY GRAY" MODEL T -200 DRAIN
BOX. MOUNT 42" A.F.F. OR AS
DIRECTED BY ARCH
NOTE: DRAIN PIPING
SLOPE NO LESS
1/4" PER FOOT.
3"
TO TRAMP
0VEABLE
GRADE
WASHING MACHINE INE DRAIN BOX
TAN< HYDROSTATIC LIFT CONCRETE SLAB SLAB STEEL
120 GAL 6400 6' L X 3' W X 10" THICK 66/0/0
250 GAL 15430 8' L X 3'W X 10" THICK #3 e 9" EW
500 GAL 2950# 10' L X 4' W X 10" THIC< 03 a 9" EW 2
1000 GAL 6310# 16'LX5'WX10 "THICK 0368 "EW 3
TIE DOWN CABLES
2
2
N.T.S.
SYMBOL
FIXTURE TYPE
TRAP
C. P.
H.W.
DESCRIPTION
1.28 <<
WATER CLOSET
3"
11/2"
-
SHOWER HEAD
O
LAVATORY
111/2
11/2"
11/211
DISHWASHER
®
BATH TUB
2"
1/2"
li2 11
w/ ANTI -SCALD VALVE
>C1<1
SHOWER
2"
11/2"
11/2"
w/ ANTI -SCALD VALVE
C,4
KITCHEN SIN<
11/211
lit °
11/211
w/ GARBAGE DISPOSAL
®
DISHWASHER
_
11/2
DISCHARGE INTO GARBAGE
DISPOSAL UNIT.
WASHING MACHI.
2"
11/2"
11/2"
FIN. FLR.
SECTION VIEW
FOR
CLARITY.
NOTE: ALL DRRAIN PIPING UNDER SLAB SHALL BE 2" MIN
2" E LESS PIA DRAIN 'w 1/4" DROP
3" 4 4" DIA DRAIN m 1 /8" DROP
WALL
"zURN"
"ZN- 1400- 5P -T -VP
FLOOR CLEANOUT.
FACE OF WALL.
STAINLESS STEEL COVER
SCREWED TO THREADED
C.O. PLUG.
"ZURN" OZ-1446-15P-VP
FOR EXPOSED BLOC<
AND GYPSUM BOARD
WALLS. "ZURN"
MZN- 144 -1-510-VP FPR TILE
WALLS. "zURN"
"ZN- 1448 -5P -VP FOR
PLASTER WALLS.
CONCRETE PAD "ZURN" "Z- 1404- VPIRON
2'x2'x8" W/ 4" 3EW. BOX W/ COVER MARKED
"CO..
FIN. GRADE
COMPACTED
FILL
ELEVATION VIE
TWO -WAY CLEANOUT TEE
OR LONG SWEEP QUARTER
BEND.
NOTE: REFER TO SPECIFICATIONS FOR
MATERIALS
AND REQUIREMENTS FOR INSTALLATION.
CLEANOUT DE TA I L S N.T.S.
SAND OR GRASS LEVEL
TIE DOWN C
Z" ANCHOR
10" CONCR
FILL VOIDS W/
OILED SAND.
CLEANOUT
FITTING W/
BRASS PLUG.
GROUND
WET SEASON WATER TABLE
UNSATISFACTORY
UNSATISFACTORY
SOIL
SOIL /WATER TABLE SITE
EVALUATION CRITERIA NTS
"GUY GRAY" MODEL T -200 DRAIN
BOX. MOUNT 42" A.F.F. OR AS
DIRECTED BY ARCH
NOTE: DRAIN PIPING
SLOPE NO LESS
1/4" PER FOOT.
3"
TO TRAMP
0VEABLE
GRADE
WASHING MACHINE INE DRAIN BOX
TAN< HYDROSTATIC LIFT CONCRETE SLAB SLAB STEEL
120 GAL 6400 6' L X 3' W X 10" THICK 66/0/0
250 GAL 15430 8' L X 3'W X 10" THICK #3 e 9" EW
500 GAL 2950# 10' L X 4' W X 10" THIC< 03 a 9" EW 2
1000 GAL 6310# 16'LX5'WX10 "THICK 0368 "EW 3
TIE DOWN CABLES
2
2
N.T.S.
FLU SING NOTES
GENERAL
PROVIDE ( FURNISH AND INSTALL ) ALL NECESSARY
MATERIALS AND LABOR FOR A COMPLETELY OPERATIONAL
PLUMBING SYSTEM AS SHOWN ON THE DRAWINGS AND
HEREIN SPECIFIED. INSTALL IN ACCORDANCE WITH THE
FLORIDA BUILDING CODE AND LOCAL ORDINANCES.
SCOPE OF WORK
PROVIDE THE FOLLOWING COMPLETE SYSTEMS
A. SANITARY COLLECTION.
8. DOMESTIGOT ANrCOLD WATER.
C. AIR CONDITIONING CONDENSATE.
PAY FOR ALL FEES, INSPECTIONS AND CONNECTION
CHARGES REQUIRED
VERIFY AT JOB SITE ALL SPACE CONDITIONS, DIMENSIONS
WITH PIPE, FIXTURES, AND EQUIPMENT SIZES PRIOR TO
FABRICATIONORINSTALLATION .COORDINATE REQUIREMENTS
TO AVOID INTERFERENCE WITH OTHER TRADES.
SUBMIT SHOP DRAWINGS FOR ARCHITECT / ENGINEER
APPROVAL BEFORE PROCEEDING WITH THE PURCHASE OR
INSTALLATION OF EQUIPMENT AND MATERIALS.
GUARANTEE ALL WORK FREE OF DEFECTS IN MATERIALS
AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM
DATE OF ACCEPTANCE.
FLU" 51NG LEGEND
SANITARY SEWER LINE
VENT LINE
CD CONDENSATE DRAINAGE LINE
CTG-- CLEANOUT TO GRADE
WCO-II WALL CLEANOUT
PT
FLOOR DRAIN
COLD WATER (C.W.) LINE
HOT WATER (H.W.) LINE
PRESS. 4 TEMP. RELIEF LINE
GATE VALVE
CHEC< VALVE
n
183"
MATERIALS
PROVIDE SHUT -OFF VALVES FOR EACH FIXTURE AND AIR
CHAMBERS WHERE SHOWN AND WHERE REQUIRED FOR
PROPER PERFORMANCE OF THE SYSTEM.
PROVIDE DIELECTRIC FITTINGS TO CONNECT PIPING TO
EQUIPMENT OF DISSIMILAR METALS. USE CLAMPS AND
FASTENERS OF SIMILAR METALS OR ISOLATE THEM FROM
PIPING AND SLABS TO PREVENT CORROSION.
PIPING
DOMESTIC HOT ANDCOLD WATER: PVC TUBING TYPE
SANITARY WASTE AND VENT: PVC PIPING
A/C CONDENSATE: PVC, SCEDULE 40 PIPE AND FITTINGS.
P.V.G. DRAIN PIPE AND FITTINGS - MAY BE USED WHEN
ALLOWED BY THE LOCAL JURISDICTION.
^'
c—�-.
VB
VIV
VTR
AFF
• FE
-� FEG
—® FCO
OUTDOOR <IT
AQOK
`T
FITTINGS
MAXIMUM
FLOW RATE
WATER CLOSETS
1.28 <<
gallons per flushing cycle
LAVATORY
1.0 <<
gpm at 60 psi
SHOWER HEAD
1.5 <<
gpm at 80 psi
SINK FAUCET
1.0 <<
gpm at 60 psi
DISHWASHER
6.5 gallons per cycle or less
(Energy Star /Water Sense Certified)
WASHING MACHINE
Water factor of 8 or lower
(Energy Star /Water Sense Certified)
FLU SING NOTES
GENERAL
PROVIDE ( FURNISH AND INSTALL ) ALL NECESSARY
MATERIALS AND LABOR FOR A COMPLETELY OPERATIONAL
PLUMBING SYSTEM AS SHOWN ON THE DRAWINGS AND
HEREIN SPECIFIED. INSTALL IN ACCORDANCE WITH THE
FLORIDA BUILDING CODE AND LOCAL ORDINANCES.
SCOPE OF WORK
PROVIDE THE FOLLOWING COMPLETE SYSTEMS
A. SANITARY COLLECTION.
8. DOMESTIGOT ANrCOLD WATER.
C. AIR CONDITIONING CONDENSATE.
PAY FOR ALL FEES, INSPECTIONS AND CONNECTION
CHARGES REQUIRED
VERIFY AT JOB SITE ALL SPACE CONDITIONS, DIMENSIONS
WITH PIPE, FIXTURES, AND EQUIPMENT SIZES PRIOR TO
FABRICATIONORINSTALLATION .COORDINATE REQUIREMENTS
TO AVOID INTERFERENCE WITH OTHER TRADES.
SUBMIT SHOP DRAWINGS FOR ARCHITECT / ENGINEER
APPROVAL BEFORE PROCEEDING WITH THE PURCHASE OR
INSTALLATION OF EQUIPMENT AND MATERIALS.
GUARANTEE ALL WORK FREE OF DEFECTS IN MATERIALS
AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM
DATE OF ACCEPTANCE.
FLU" 51NG LEGEND
SANITARY SEWER LINE
VENT LINE
CD CONDENSATE DRAINAGE LINE
CTG-- CLEANOUT TO GRADE
WCO-II WALL CLEANOUT
PT
FLOOR DRAIN
COLD WATER (C.W.) LINE
HOT WATER (H.W.) LINE
PRESS. 4 TEMP. RELIEF LINE
GATE VALVE
CHEC< VALVE
n
183"
MATERIALS
PROVIDE SHUT -OFF VALVES FOR EACH FIXTURE AND AIR
CHAMBERS WHERE SHOWN AND WHERE REQUIRED FOR
PROPER PERFORMANCE OF THE SYSTEM.
PROVIDE DIELECTRIC FITTINGS TO CONNECT PIPING TO
EQUIPMENT OF DISSIMILAR METALS. USE CLAMPS AND
FASTENERS OF SIMILAR METALS OR ISOLATE THEM FROM
PIPING AND SLABS TO PREVENT CORROSION.
PIPING
DOMESTIC HOT ANDCOLD WATER: PVC TUBING TYPE
SANITARY WASTE AND VENT: PVC PIPING
A/C CONDENSATE: PVC, SCEDULE 40 PIPE AND FITTINGS.
P.V.G. DRAIN PIPE AND FITTINGS - MAY BE USED WHEN
ALLOWED BY THE LOCAL JURISDICTION.
^'
c—�-.
VB
VIV
VTR
AFF
• FE
-� FEG
—® FCO
OUTDOOR <IT
AQOK
.e
UNION
HOSE BIBS
VACUUM BREA <ER
VALVE IN VERTICAL
VENT THRU ROOF
ABOVE FINISHED FLOOR LEVEL
FIRE EXTINGUISHER ON WALL BRACKET (2A -105C)
FIRE EXTINGUISHER IN CABINET (2,4 -105C)
FLOOR CLEAN OUT
PRESS. 4 TEMP. RELIEF VALVE
SCORE OF REVISION:
1. -ADDED TAN<LESS CHAS WATER HEATER.
8
NORITZ MODEL NU -98E
GAS TANKLESS
WATER HEATER
PIPE
FROM SERV.
COLD WATER
-HW TO FIXTURES
98e TECHNICAL SPECIFICATIONS:
POWER IMPUT: NATURAL GAS 15)00- 199,000 BTU
MINIMUM FLOW TO ACTIVATE (GPMh 0.40 GALLONS PER MINUTE (GPM)
`T
17 F RISE /42 GF'M
,=
W "Z_
65' F RISE/52l GPM
^_-
Z W,N 5��.4
ENERGY FACTOR:
NG:.95
THERMAL EFFICIENCY
N.G:B2%
DIMENSIONS:
p- ` �. _, , �w o
WEIGHT
612 LBS.
U W LUU)LOa,o
YES
IGNITION
J�Loa) N
Z�L
CI
4U
L
o
o
cm,)
J (0
z
Q
n
'k-
Z
Q
0
0 ml,
<-W
°�noo
�
C,4
�
G7(�a-
.e
UNION
HOSE BIBS
VACUUM BREA <ER
VALVE IN VERTICAL
VENT THRU ROOF
ABOVE FINISHED FLOOR LEVEL
FIRE EXTINGUISHER ON WALL BRACKET (2A -105C)
FIRE EXTINGUISHER IN CABINET (2,4 -105C)
FLOOR CLEAN OUT
PRESS. 4 TEMP. RELIEF VALVE
SCORE OF REVISION:
1. -ADDED TAN<LESS CHAS WATER HEATER.
8
NORITZ MODEL NU -98E
GAS TANKLESS
WATER HEATER
PIPE
FROM SERV.
COLD WATER
-HW TO FIXTURES
98e TECHNICAL SPECIFICATIONS:
POWER IMPUT: NATURAL GAS 15)00- 199,000 BTU
MINIMUM FLOW TO ACTIVATE (GPMh 0.40 GALLONS PER MINUTE (GPM)
CHAS WATER ,NEATER DETAIL
N.T.S.
s
N
90' F RISE /3b GPM
17 F RISE /42 GF'M
FLOW RATES.
65' F RISE/52l GPM
45' F. RISE/5.9' GF'M
ENERGY FACTOR:
NG:.95
THERMAL EFFICIENCY
N.G:B2%
DIMENSIONS:
H: 2601 W: 183" D: 10"
WEIGHT
612 LBS.
MODULING GAS
YES
IGNITION
ELECTRICAL (120 V PLUGS IN)
CHAS WATER ,NEATER DETAIL
N.T.S.
s
N
10
LIJ
m
w
�Qo
i- Z
''i
Q<
w
Q�
V)
j
Zw�
2w=
Z
CI
4U
L
o
o
r
L
z
Q
n
'k-
Z
Q
0
0 ml,
<-W
r
REVISIO
1 /2\ 05 -05 -141
DESCRIPTION
Project No.
13001
Date:
12 -25 -13
Drawn By:
Y. SOSA
Approved By:
P.M.
P . •. NF °
N SF '•� ° ° °°
A205� ••% .
�^ Y
cr .
N� :w:
of-
Lll b
°,off .F�0R�
FLORIDA RE.GJV% 650,
P-2
v
�m
�
w
�Qo
i- Z
''i
Q<
w
Q�
V)
Zw�
2w=
Z
CI
4U
L
o
o
r
L
z
Q
L
'k-
Z
Q
0
0 ml,
REVISIO
1 /2\ 05 -05 -141
DESCRIPTION
Project No.
13001
Date:
12 -25 -13
Drawn By:
Y. SOSA
Approved By:
P.M.
P . •. NF °
N SF '•� ° ° °°
A205� ••% .
�^ Y
cr .
N� :w:
of-
Lll b
°,off .F�0R�
FLORIDA RE.GJV% 650,
P-2
v