Loading...
13-1386R-002U •d b P-4 1. 0 0 w b 0 m 0 P4 0 P., I I d CID 0 m D W e7 O cq a / N td -I r, 0 cli 0 c� d z z x w w z z w z H a 0 n, NOTES: GENERAL NOTES: I.-SHALL COMPLY FLORIDA BUILDING CODE, BUILDING EDITION 2010 ALL LOCAL ORDINANCES GOVERNING. 2.-CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES BEFORE STARTING THE WORK 3.-CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLIANCE WITH ALL SAFETY RELATED O.S.H.A. REQUIREMENTS DURING CONSTRUCTION. 4. -ALL WORK SHALL BE PERFORMED BY A LICENSED AND INSURED STATE CERTIFIED GENERAL CONTRACTOR OR BY THE OWNER IF APPROVED BY THE LOCAL BUILDING DEPARTMENT OFFICIAL. 5: 5AFETY PROVISIONS DURING CONSTRUCTION AND PROTECTION OF ADJACENT PUBLIC AND PRIVATE PROPERTIES. ACCORDING TO CHAPTER 13 OF THE EXISTING FLORIDA BUILDING 2010 EDITION. ENVIRONMENTAL PROTECTION: 1.- CONTROL AMOUNT OF DUST RESULTING FROM CONSTRUCTION OR DEMOLITION TO PREVENT SPREAD OF DUST TO OTHER BUILDINGS AND TO AVOID CREATION OF A NUISANCE IN SURROUNDING AREAS16E OF WATER TO CONTROL DUST WILL NOT BE ALLOWED WHEN IT WILL RESULT IN, OR CREATE HAZARDOUS OR OBJECTIONABLE CONDITIONS SUCH AS FLOODING. 2.-TRAFFIC MAINTENANCE: CONDUCT REMOVAL OPERATIONS TO MAINTAIN TRAFFIC ALONG EXISTING STREETS AND WALKS. KEEP PAVED STREETS AND WALKWAYS FREE OF DEBRIS. REMOVE MATERIAL AND OTHER MATTER TRACKED OR FALLEN ONTO TRAFFIC SURFACES. 3.-THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION MATERIALS INCLUIDING DEBRIS AND DUST, AND DISPOSE OF LEGALLY OFF SITE. USE METHODS APPROVED BY A/E BEFORE BEGINING CLEANUP OPERATIONS.USE OF BLOWERS TO DISTRIBUTE DUST IS NOT ALLOWED. FLAME SPREAD AND SMOKE DENSITY: 1. -WALL AND CEILING FINISHES SHALL BE HAVE FLAME SPREAD CLASSIFICATION OF NOT GREATER THAN 200. EXCEPTION: FLAME - SPREAD REQUIREMENTS FOR FINISHES SHALL NOT APPLY TO TRIM DEFINED AS PICTURE MOLDS, CHAIR RAILS, BASEBOARDS AND HANDRAILSi TO DOORS AND WINDOWS OR THEIR FRAMES 2.-WALL AND CEILING FINISHES SHALL HAVE A SMOKE - DEVELOPED INDEX OF NOT GREATER THAN 450. 3.-INSULATION MATERIALS, INCLUDING FACINGS, SUCH AS VAPOR RETARDERS OR VAPOR PERMEABLE MEMBRANES INSTALLED WITHIN FLOOR - CEILING ASSEMBLIES, ROOF - CEILING ASSEMBLIES, WALL ASSEMBLIES, CRAWL SPACES AND ATTICS SHALL HAVE A FLAME - SPREAD INDEX NOT TO EXCEED 25 WITH AN ACCOMPANYING SMOKE- DEVELOPED INDEX NOT TO EXCEED 450 WHEN TESTED IN ACCORDANCE WITH ASTM E 84. EXCEPTIONS: I.-WHEN SUCH MATERIALS ARE INSTALLED IN CONCEALED SPACES, THE FLAME - SPREAD AND SMOKE - DEVELOPED LIMITATIONS DO NOT APPLY TO THE FACINGS, PROVIDED THAT THE FACING 15 INSTALLED IN SUBSTANTIAL CONTACT WITH THE UNEXPOSED SURFACE OF THE CEILING, FLOOR OR WALL FINISH. 2.- CELLULOSE LOOSE -FILL INSULATION, WHICH 15 NOT SPRAY APPLIED, COMPLYING WITH THE REQUIREMENTS OF SECTION 83163, SHALL ONLY BE REQUIRED TO MEET THE SMOKE - DEVELOPED INDEX OF NOT MORE THAN 450. ?Jf#- FM pi, �• ti I.-THE REWUIRED EXIT DOORS SHALL BE A SIDE - HINGED DOOR NOT LESS THAN 3 FEET IN WIDTH AND 6 FEET 8 INCHES IN HEIGHT. OTHER DOORS SHALL NOT BE REQUIRED TO COMPLY WITH THESE MINIMUM DIMENSIONS. AS PER F.B.C. RESIDENCIAL. 2.-ALL LOCKS OR LATCH ON EGREES DOOR SHALL BE READILY OPENABLE FROM THE SIDE FROM WHICH EGRESS 15 TO BE MADE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEGDE OR EFFORT AS PER RESIDENCIAL 2010 EDITION. 3.-ALL SINGLE EXTERIOR SWING DOORS SHALL HAVE A LOOCK TO BE KEY OPERATED FROM THE EXTERIOR WITH A MINIMUM OF 6000 POSSIBLE KEY CHANGES OR LOCKING AUXILIARY SINGLE DEAD BOLT WITH HARDENED BOLT. ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RESISTING A FORCE OF 300 LBS. APPLIED IN ANY MOVABLE DIRECTION AND IN ACCORDANCE WITH RESISTANCE STANDARS SET FORTH BY FLORIDA BUILDING CODE. 4.-THE ACTIVE LEAF OF PAIRS OF EXTERIOR SWING DOORS SHALL HAVE SAME LOCKS AS REQUIRED FOR SINGLE EXTERIORSWING DOORS. THE INACTIVE LEAF SHALL HAVE MULTIPLE POINTS OF LOCKS WITH 5/8" MIN. THROW BOLTS WITH INSERTS. 5: JAMBS OF ALL EXTERIOR OFFSET TYPE IN SWING DOORS SHALL BE RABBETED, OR OF SIMILAR FABRICATION, TO PREVENT DEFEATING THE PURPOSE OF THE STRIKE AND THE INTEGRITY OF THE LOCKS AND LATCHES. 6.- HINGES ON EXTERIOR OUT SWINGING DOORS SHALL HAVE NON - REMOVABLE PINS AND NON - EXPOSED SCREWS. I.-GLASS AND EXTERIOR DOORS SHALL COMPLY WITH THE AMERICAN NATIONAL STANDARDS INSTITUTES STANDARD 291.1. 8.- VISION PANEL EXTERIOR DOORS OTHER THAN GLAZING WITHIN 40" OF THE INSIDE LOCKING ACTIVATION DEVICE OF LOOSE AND SWING DOORS SHALL COMPLY WITH THE ANSI STANDARD 291.1. 13.-ALL WINDOW, DOORS, GLASS AND GLAZING SHALL BE AS SET OF CHARTER 24 OF F.B.C. BUILDING 2010 EDITION. lo.-FRONT MAIN ENTRANCE DOORS SHALL BE PROVIDED WITH A DOOR SCOPE OR VISION PANELS. II.-ALL EGRE55 WINDOWS TO HAVE A CLEAR OPENING OF NOT LESS THAN 30" IN WIDTH AND 24" IN HEIGHT, MINIMUM 5.1 S.F. IN AREA HEIGHT TO OPENING SHALL NOT EXCEED 36" ABOVE FINISH FLOOR 12.- SECONDARY MEANS OF ESCAPE SHALL CONFORM TO NF.P.A. 22- 2.12.0 WINDOWS USED AS SECOND MEANS OF ESCAPE MUST PROVIDE A CLEAR OPENING (WHEN FULLY OPENED) OF NOT LESS THAN TWENTY INCHES (20 ") IN WIDTH, TWENTY FOUR INCHES (24 ") IN HEIGHT AND 5.1 SQUARE FEET IN AREA +/- AND THE BOTTOM OF THE OPENING SHALL NOT BE MORE THAN FORTY FOUR INCHES (36 ") OFF THE FLOOR 13. -ALL WINDOWS USED SHALL HAVE DADE COUNTY PRODUCT APPROVAL. 14.- COORDINATE ALL MASONRY OPENINGS FOR WINDOWS t DOORS WITH WINDOWS t DOOR MANUFACTURER PRIOR TO TIE BEAM AND BLOCK ERECTION. BATHROOMS: NON - ABSORBENT SURFACE ON WALLS ENCLOSING BATHTUBS AND SHOWER COMPARTMENTS MUST EXTEND TO A HEIGHT OF NOT LESS THAN 12" ABOVE FLOOR TYPICAL FOR ALL BATHROOMS AS PER F.B.G. 01 83012. I