13-152-004CONSTRUCTION FLOOR PLAN
1'-0"
TYPE I EXISTING I-HR RATED DEMISING PARTITION
r;Xl5TINC7 0Ob!L7UKKjION:
EXISTING I-HR RATED DEMISING PARTITION TO REMAIN. FIRE
CAULK ALL PENETRATIONS.
EXIST. STOREFRONT TO REMAIN
CXIf2'1lblC7 STOREFRONT:
EXISTING STOREFRONT TO REMAIN.
TYPE 3 EXIST. TO REMAIN
EXISTING CONSTRUCTION-.
EXISTING CONSTRUCTION TO REMAIN. PATCH, REPAIR AND
PREPARE 5URFA(:,E AS REQUIRED FOR NEW FINISHES.
TYPE 4 EXISTING PARTITION To BE I-HR (DET. 5, SHEET A-1.0)
EXISTING CONSTRUCTION- CONVERT TO I-HR RATED
PARTITION:
CONVERT EXISTING PARTITION INTO 1-HR FIRE RATED
PARTITION PER UL DESIGN U4401. EXTEND To UNDERSIDE OF
STRUCTURE. FIRE CAULK ALL PENETRATIONS.
TYPE 5 NEW I-HR RATED DEMISING PART. (VET. 5, SHEET
A-1.0)
NEW CONSTRUCTION:
NEW I-HR RATED DEMISING PARTITION PER UL DESIGN U4141.
EXTEND To UNDER54DE OF STRUCTURE. FIRE CAULK ALL
PENETRATIONS.
FF
*1--jeLD vmpy axisrNs CONDITIONS PRIOR TO 001%,MENCINS WORK. IF
TMe ARE ANY vI5C4epAt4II!5 Pte" TVeEN EXISTING CONDITIONS AND
THE INTENT OF THESE DRAWINGS NOTIFY ARCHITECT IN WRITING
IMMEDIATELY,, PRIOR TO COMMENCING WORK.