13-1205-028STANDARD 3" WIDE HANGERS Hanget extension to be the sum of the distances between the hanging wires and the duct size, iD (Smacna) CHANNEL SECTION IF Total Maximum Hanger Duct size, inches Spacing 48: Wide or grater 4 ft Less tha 48" wide Eft and less than 48" 6" deep 3" X 15" Width between 2S" roft 4 48" and greater 301' than 16" deep 311 X 21 Less than 29" wide art and 16" depth or less CHANNEL SECTION IF Total Minimum Minimum Extension is Channel Channel not greater than: Gauge Profile 6" 24 3" X 15" 18" 22 3" X 2" 301' l8 311 X 21 USE OF 2" WiDE 22 gauge 2'x 151f hangers may be substituted for 3" hangers for ducts with widths not over 48" and depths not over 24" provided that not more than one Joint occurs between hangers and the maximum hanger spacing Oft. Exception: When duct perimeter is 80" or less and does not require reinforcement two Joints are permitted between hangers s Ho4N (3E2Rns AND 5Uf'I='O�:TS 2 -1/2" SQUARE WASHERS 12" MAX. O.G., MIN. 2 PER SiDE. 010 X 1 -1/4" SHEET METAL SCREWS. FIBROUS GLASS DUCT. GFM CLOSURE. FLANGE. 6 SCREW, POP RIVET OR SPOT WELD TO EQUIPMENT FLANGE. A. H. U P LE NUM C O NNE C TIO N. N.T.S. 4"0 EXHAUST DUCT STEEL HANGER WiRE TYPICAL CEILING CABINET EXHAUST FAN KITH BACKDRAFT DAMPER, LOW NOISE LEVEL AND NO WBRA770N. FRONT FACE GRILLE K1TH FASTENING SCREENS EXHAUST FAN HANGING BRACKET (ADJUSTABLE) CEILING MOUNTED CABINET EXHAUST FAN DETAIL N. T. S. GENERAL H. V.A.C. NOTES 1. The contractor shall furnish all labor, material and equipment for a complete H.V.A.C. system in accordance with these drawings. The Florida Building Code 2010 and the latest edition of the following publications: (a )ANS B9.1 Mechanical Refrigeration (b) NFPA Pamphlets 90A & 91 c) SMACNA (d) ASHRAE. 2. All air conditioning ductwork shall be 1 112 " standard duty foil reinforced fiberglass (R -6) manufactured logo printed on the vapor barrier. 3. All exhaust ductwork shall be code gage galvanized sheet metal. 4. Duct size shown are net free area inside. 5. All air devices diffusers, registers and grilles) shall be all aluminum construction, with exposed surface chemically treated to receive paint to match color or AiRGUIDE or approved equal. 6. Provide opposed blade dampers at all diffusers and registers. 7. Thermostats shall be combination cooling /heating with system Cool /Auto /Heat /Off and Fan On /Auto selector switches. 8. Refrigerant piping shall be copper type "L" with 314" ormoflex. Insulation shall be provided for suction lines. 9. Provide new filters for fan coil before starting. These filters must also be replaced prior to final acceptance by owner. 10. Refrigerant suction line shall be insulated with R -4 minimum insulation and external permeance, not exceeding 0.05 perm (ASTME 96) UNIT MUST BE INSTALLED TO Wi THSTAND 160 MPH HURRICANE FORCE WINDS & PROVIDE 1-X118- STRAP 77E —DOWN TO UNIT FASTENED INSIDE C.U. TO SLAB W/ 4 -114 "0 x 1 -112" POWDERED ACTUATED PiNS AS PER MANUFACTURER SPEC'S POWER & CONTROL LOCA77ON POEFENES LIQUID LINE W/ 0 INSULATION SUCTION LINE W/ 112 ARMAFLEX INSULATION & VAPOR BARRIER NOTE. UNITS SHALL BE CLEAR BY 3" MIN. FROM DRIP LINE. MECHANICAL DETAILS PACK VOID SW/ ARMAFLEX & COAT W/ SILICONE SEALANT FOR TIGH CLOSURE 1" MIN CONCRETE SLAB REFRIGERANT LINES UP THRU CONCRETE SLAB. PVC PiPE -RUN UNDER SLAB SEE FLOOR PLAN FOR LOCATION (SCH. 40 W/ SOLVENT WELD JOINTS) USE 4" OR 5" PIPE AS REQUIRED THEN RUN REF. PIPING IN WALL SPACE HARD TUBING SOFT TUBING 0 REFRIGERANT LINE WIPING DETAIL. N. T.S. NOTES: 1. CONCEALED OR NOW REMOVABLE JOINTS SHALL NOT BE INSTALLED BELOW SLAB 2. PVC. SCH. 40 SLEEVE SHALL BE 2" LARGER THAT THE PIPE INSULATION ENCASED. HAVING AN ANGLE NO GREATER THAN 45 DEGREES WiTH THE ENCASED REFRIGERANT PiPiNG REMOVABLE FOR REPLACEMENT. PROVIDE A MIN. OF 6" SPACE BETWEEN THE UNIT AND PARTITIONS AT SIDES, BACK AND TOP THE ENCLOSING SPACE (FBCR -M 1305.1.1) COIL /HEAT FAN SECTION SECTION FILTER ACCESS AHU SHALL BE MECHANICALLY ATTACHED TO THE SUPPLY AIR PLENUM DUCT WALLS I— REF. LINES PROVIDE CAP OFF WITH 114" PERFORATED FOR VENT 12" MiN. DRAIN PAN W /WET DETECTOR ? TO CONTROL OVERFLOW BY J� SHUTTING DOWN THE UNiT WHEN ACTIVATED. PREFAB MTL. FRAME F. F. A/C CLOSET I N STALLATI O N �Co rt -w m Zc n T 0) CC)ao M 00 `2 0 O 0 H o I.-, N �Z� W0 Ha a w � EV- a0 0 O m 0 0 ao Co o Co .r ®ammlIZIMaa Pao ®Q0 ®m aaal�u ®a6aa �� P.E. No 53288 Jose Antonio Mendez. Professional Engineer ® o in 0 a 1385 Coral Way Suite #203 Miam pmoffalsaammaa Miami. FL 33145 ammo ®aa ®um® PO ®P. PH:(305)854 -9824 FAX(305)856 -1797 jose0118@aol.com CA 00008324 • • LO H (� �"� O Z O A � � 1--1 E LO v E-H Z O U a O W O z 1 O ! I r~ 0 .4 to $_. 91 J n ¢� b o as 'cl ^d U A, sheet no. M -2 - of -