08-1111-002, 1 TELE. EQUIP. UN19 \ P.B.X. \ N�_ \ NEW 14D49 \\ 1 1 MEZZANINE FLOOR PLAN SCALE: 1/8" - 1' -0' I I I / / I \ 1 \ SECOND FLOOR PLAN \\ SCALE: 1/8" I / / I / I / I / 1 / F AY • X11 15 13 FIRST FLOOR PLAN z SCALE: 1/8" psi z oaT" o 1 Y 1 NEW ��, 1TJN)2 To ROOF I Ntw I \ / I T 1 I` ( I I I I I MINA MECHANICALLY VENTILATED AREA THIS IS A NON SPRINKLED BUILDING eM ALARM SYS-IU4 TO BE RMAUM IN AaMFMANMWrM NFTPA72:71% 101" FIRE ALARM SHIALL BE A CENTRAL STAM,, SERVICE. A CERTIFICATE OR BMCARID SHALL BE POBTEI) AT FIN& DISPECTM. AS PER NFPA 72 CAROB.1AW MPR NUICYPWAL Ur. 01111!11111 11180 NIINr 4o Nl'IFB>tT -- - -- - 7i SCOPE OF WORK CHANGE FACP FROM UNIMODE 4520 TO UNIMODE 9600 AND ADD ADDITIONAL DEVICES AS SHOWN ON PLANS. MOVE 2 EXISTING NAC CKTS FROM UNIMODE 4520 TO NEW POWER SUPPLY. PROVIDE POWER SUPPLY TO POWER EXISTING SMOKE DETECTORS. FIRE ALARM RTES 1. THIS IS A POWER LIMITED FIRE ALARM SYSTEM. ALL DEVICES OR UNITS SHALL BE INSTALLED USING APPROVED MATERIALS AND WIRING PRACTICES IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE 070 AND THE NATIONAL FIRE PROTECTION ASSOCIATION ARTICLEf760 POWER LIMITED SECTION AND ALL APPLICABLE LOCAL WIRING ORDINANCES. 2. CONDUCTORS AND CABLES FOR USE WITH THIS POVER LIMITED FIRE ALARM SHALL BE INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE 0760 POWER LIMITED SECTION AND SHALL BE LISTED FOR THIS USE CONDUCTORS SHALL HAVE MINIMUM RATING OF 300V AND SHALL BE lF SOLID COPPER OR BUNCH- TINNED STRANDED COPPER CONDUCTORS. THESE CONDUCTORS OR CABLES SHALL BE FPLP OR FPLR IN ACCORDANCE WITH NEC ARTICLE 760 AND NEC ARTICLE 725 CLASS 2 OR 3 CIRCUITS. 3. CONDUCTORS OR CABLES USED IN DUCTS OR PLENUM TYPE CEILING F13R ENVIRONMENT AIR SHALL EMPLOY THE USE OF ELECTRICAL METAL TUBING OR PLENUM RATED INSULATED TYPE CABLE 0"). THE CABLE SHALL BE UL LISTED FOR SUCH USE AND MEET ALL THE REQUIREMENTS 13F THE NATIONAL FIRE PROTECTION ASSOCIATION. 4. ALL INDICATING DEVICES SHALL BE MOUNTED AT 80' A.F.F. FROM THE FLOOR TO THE BOTTOM OF THE LENS UNLESS OTHERWISE NOTED, AND SWILL BE UL LISTED 1971 ADA 75 CANDELA MINIMl1HL 5. ALL MANUAL- INITIATING DEVICES SHALL BE MOUNTED AT 48' TO CENTER AFF. UNLESS OTHERWISE NOTED, 6. CUSTOMER TO PROVIDE (2) PHONE LINES FOR CERTIFICATED CENTRAL STATION MONITORING WITH DIFFERENT LONG DISTANCE CARRIERS. 7. ELECTRICAL CONTRACTOR TO PROVIDE ILOV DEDICATED CIRCUIT WITH 2OAMP CIRCUIT BREAKER, USING 12AVG THHN TYPE WIRE WITH 600V MINIMUI4 INSULATIO. IN I/2' HIM" CONDUIT. THE THE CIRCUIT BREAKER NUMBER AND PANEL SHALL BE NOTED AND MARKED IN ACCORDANCE TO WPA 72, AND ANY LOCAL ORDINANCE. 8. ALL INDICATING CIRCUITS SHALL BE STYLE Y (CLASS B) UNLESS OTHERWISE SPECIFIED. ALL INITIATING ADDRESSABLE DEVICES SHALL CONNECT WITH TWO WIRES TO ONE IF THE CONTROL PANELS SLC LOOPS. 9. DUCT DETECTOR SEQUENCE OF OPERATION UPON ALARM DUCT DETECTOR SHALL ACTIVATE ANY TROUBLE CONDITION VILL BE ANNUNCIATED4T THE MAIN PANEL, AND ANNUNCIATOR, ALSO SHUTDOWN A/C UNIT 10. ANY DUCT DETECTOR ALARM SHALL CAUSE THE AIR HANDLERS TO SHUT DOWN. 11. THIS SYSTEM WILL BE CERTIFICATED AS A CENTRAL STATION SERVICE FIRE ALARM SYSTEM. 12. ALLOVABLC AMPACITY ACCORDING TO CONDUCTOR SIZE. SIZE(AVG) ALLOWABLE AMPACITY 18 6 16 8 1♦ 17 12 23 10 28 13. MAXIMUM NUMBER OF CONDUCTORS IN ELECTRICAL METAL TUBING. L= 2TM TRADE SIZES IN INCHES LETTER SIZE (AVG) 1/2' 3/4' 1' 1 -1/4' 1 -1/2' 2' 2 -1/2' TEN, TFFN 18AWG 22 38 63 108 148 244 TFN, TFFN 16AW6 17 29 48 83 113 186 THHN 14AVG 12 22 35 61 84 138 241 THVN 12AVG 09 16 26 45 61 101 176 THVN -2 IOAVG 05 10 16 28 38 63 111 WIRE LEGEND CHART TYPE 0Niri1CTORS /DESCRIPT ❑N MARKINGS A 2 COND 18 AVG SOLID ADT493490 ZC /18AWG TYPE FPLP /CMP(UL) 9 4 COND 16 AVG SOLID ADT494449 4C /18AVG TYPE FPLP /CMP(UL) C 2 COND 14 AVG SOLID ADT493491 2C /14AWG TYPE FPLP /CMP(UL) D 2 COND 16 AVG SOLID SHLD 860830A 2C /18AVG TYPE FPLP /C>P(UL) E 4 COND 18 AVG SOLID SHLD 860836 4C /18AVG TYPE FPLP /CRP(UL) F 4 COND 22 AVG SOLID ADT494469 4C /22AVG TYPE FPLP /CMP(lL) G 12 COND 22 AVG SOLID ADT494469 12C /22AVG TYPE FPLP /CMP(UL) H 2 COND 18 AVG SOLID BLACK BURIAL 180010 2C /1BAVG TYPE FPL.P /IRR(M) 14. ALL EQUIPMENT COMPATIBLE AND LL LISTED FOR FIRE SERVICE 1/2' MIN EMC FOR STUBS 40% FILL FOR ALL CONDUIT. 15. THE DESIGN INSTALLATION COPLIES WITH FBC 11 -428.3 SEQUENCE OF OPERATION ANY INITIATING DEVICE ACTIVATED SHALL CAUSE THE FIRE ALARM PANEL TO GO INTO ALARM CONDITION, ON INITIATING DEVICE SUPERVISORY SIGNAL SHALL CAUSE THE FIRE ALARM PANEL TO SHOW A SUPERVISORY CONDITION, ALSO ON ANY TROUBLE CONDITION, BOTH THESE SIGNALS WILL DISPLAY THE DEVICE OR ZONE ON THE FRONT PANBIS WELL AS ANY REMOTE ANNLINCIAT13RS CONNECTED TO SYSTEM. ACTIVATE INDICATING DEVICES, TRAMSMIT SIGNAL TO OFFSITE LISTED CENTRAL STATION AND ACTIVATE OR OPERATE OPERATE ANY AUX. RELAYS OR FUNCTONSAS NOTED W FLOOR PLAN. SEE SEQUENCE O OPERATION MATRIX AS SHOWN ON PLANS. FIRE ALARM LEGEND CONTRACTOR SHALL COORDINATE ALL MOUNTING HEIGHTS AND FINAL LOCATIONS OF DEVICES WITH A REPRESENTATVE PRIOR TO ROUGH -IN). SYMBOL DESCRIPTION PART / CATALOG / MANUFACTURER FIRE ALARM CABINET - INSTALLED 5' -0' AFF UNIMODE 9600 ADT 8 POWER SUPPLY FCPS -24FSS ADT POWER SUPPLY FCPS -24FSB ADT FIRE ALARM MANUAL PULL STATION ADT -BG-10 ADT a FIRE ALARM MANUAL PULL STATION ADT- BC -I2LX ADT D� WEATHERPROOF FIRE ALARM MANUAL PULL STATION ADT- BQ -I2LOB FIREUTE 1� FIRE ALARM HORN - STROBE -'RED' CANDELLA 15/75 GX90S- 4- 15/75 -W GENTEX FIRE ALARM HORN- STROBE -'RED' CANDELLA 75 P2R SYSTEM SENSOR FIRE ALARM HORN - STROBE -'RED' CANDELLA 110 P2R SYSTEM SENSOR WEATHERPROOF HORN - STROBE -'RED" CANDELLA 75 P2RK SYSTEM SENSOR FIRE ALARM STROBE -'RED' CANDELLA 75 SR SYSTEM SENSOR @D DUCT SMOKE DETECTOR P.O.C. BY OTHERS 9p_ P PHOTO ELECTRIC SMOKE DETECTOR 3534 -2 CRT ADT 2 PHOTO ELECTRIC SMOKE DETECTOR 50355 ADT HO HEAT DETECTOR 4220 -135 ADT ® CONTROL. RELAY CRF -300 ADT Q MONITOR MODULE MMF -300 ADT Q LCD ANNUNCIATOR LCD -80F ADT B❑ BEAM SMOKE DETECTOR BEAM1224S/BEAMMMK SYSTEM SENSOR REVISIONS ' ' I ''1_" I114 v. . 2801 GATEWAY DRIVE POMPANO BEACH, FLORIDA 33089 (954) 917 -2400 FAX (954) 917 -2419 DATES: dH.T. GEORGE A MANGINEW EF OW1121 x,/22/00 FIR ST NATIONAL BANK OF SOUTH FLORIDA 5750 SUNSET DRIVE S.-MIAMI. FL 33143 ocoomm - - - - -- ADT FIRE ALARM PLAN R.0 OATS: SCAIL• SHM Ma: m N0.: 8/11/00 1/8' . 1' -0' 1 OF 2 149- 03915 -38 CITY OF SOUTH MIAMI BUILDING DEPT. ELECTRICAL SECTION APPROVED 8Y: / c SATE' (�