13-488R-001ENEU REEN EMEN INEE 0 1/2 "0 SCHD. 40 BLACK - IRON SUPPLY LINE 3/8 "0 SCHD. 40 BLACK - IRON SUPPLY LINE VENT PLUG 1/4" OD COPPER TUBE (1) WHDR -260 CYLINDER (1) WHDR -400 CYLINDER PERF 8" 12" MI TO FUSIBLE LINKS AND REMOTE PULL STATION i TO GAS VALVE XV CONTROL BOX CONTROL PANEL REMOTE FIRE CABINET HOOD & LIGHT SWITCH TO TANK #2 IN 10 10 REMOTE FIRE CABINET 1/16" S/S CABLE IN 1/2" EMT TO XV CONTROL BOX IN CABINET USE CORNER PULLEYS AT ALL CHANGE OF DIRECTIONS f' „ 1� ' i . - 7il. 1/16" S/S CABLE IN 1/2" EMT TO XV CONTROL BOX IN CABINET USE CORNER PULLEYS AT ALL SEE PLAN VIEW I CHANGE OF DIRECTIONS FOR SPECIFIC LOCATION OF PULL STATION I I I I I ZEMOTE FIRE CABINET I i I I 17 O • I I I I I I MECHANICAL GAS VALVE FIELD LOCATE AND I f CONNECT 0 @ @ @ EIRE SUPPRESSION ELEVATION VIEW SCALE: 1/2" = 1' -0" CONTROL PANEL & DOUBLE MICROSWITCH PROVIDED BY HOOD DEPOT. CONTROL PANEL PRE -WIRED TO LIGHT SWITCH, HOOD SWITCH, AND 1 POLE OF FIRE SYSTEM MICROSWITCH. THE CONTROL PANEL IS PRE -WIRED TO SHUTDOWN MUA AND TURN ON EXHAUST IN CASE OF FIRE. ALL OTHER CONNECTIONS ARE TO BE MADE BY OTHERS. THERE IS (1) NO /NC MICROSWITCH AVAILABLE IN THE J -BOX FOR FIRE ALARM ACTIVATION. FOR OTHER REQUIREMENTS SUCH AS THE SHUTDOWN OF ELECTRIC APPLIANCES AND RECEPTACLES UNDER HOOD, GAS SOLENOID ACTIVATION, AND ANY OTHER REQUIREMENTS BY NATIONAL, STATE, OR LOCAL AUTHORITIES HAVING JURISICTION USE TERMINALS NC AND NO AS REQUIRED. NC /NO HAVE 115V /1PHASE AND ARE ACTIVATED UPON FIRE SYSTEM ACTUATION. NOTE: IF THERE IS NO BUILDING ALARM IT MAY BE REQUIRED TO PROVIDE A HORN TO BE SOUNDED UPON FIRE SYSTEM ACTUATION. CONTACT YOUR MUNICIPALITY FOR THEIR REQUIREMENTS. FIRE CABINET /FIRE SYSTEM DETAILS KIDDE NOZZLE DETAIL RING PATTERN DM ADP F GRW R LPF LPR 0 1 2 3 4 1 &4 0 RINGS RING RINGS RINGS RINGS RINGS RINGS W/ DISC & CORE DUCT TEMPERATURE SENSOR DETAIL DUCT TEMPERATURE SENSOR TEMPERATURE SENSOR TO BE PLACED IN THE GREASE EXHAUST DUCT TO ACTIVATE THE EXHAUST HOOD SYSTEM PER FLORIDA MECHANICAL CODE 507.2.1.1 OPERATION. WHICH STATES TYPE I HOOD SYSTEMS SHALL BE DESIGNED AND INSTALLED TO AUTOMATICALLY ACTIVATE THE EXHAUST FAN WHENEVER COOKING OPERATIONS OCCUR. THE ACTIVATION OF THE EXHAUST FAN SHALL OCCUR THROUGH AN INTERLOCK WITH THE COOKING APPLIANCES, BY MEANS OF HEAT SENSORS OR BY MEANS OF OTHER APPROVED METHODS. TO SENSOR RELAY IN THE HOOD DEPOT CONTROL PANEL ) STEEL 0 KIDDE WHDR SCHEDULE NOZZLE APPLICATION COVERAGE LENGTH OF DUCT PER NOZZLE SPECIAL NOTES FOR COVERAGE FLOW P fIN)S TANK 1 No. F.P. TANK 2 No. F.P. ADP Duct 50" PERIMETER UNLIMITED N/A 1 0 0 1 1 1 (2) ADP Duct 100" PERIMETER UNLIMITED 2 ADP nozzles re 'd 1 1 1 2 2 1 0 1 0 NOZZLE APPLICATION COVERAGE NOZZLE HEIGHT (in inches) SPECIAL NOTES FOR COVERAGE FLOW PfIN)S 1 No. F.P. 2 No. F.P. ADP Plenum 10' x 4' N/A 'Y" Bank or Sin le 1 1 1 1 1 NOZZLE APPLICATION COVERAGE UMTATONEFROM COOKING SURFACE SPECIAL NOTES FOR COVERAGE PQIN>)S (( f. 1 NO. F.P. 2 No. F.P. DM Mesquite Charbroiler (chips, wood, logs) 30" X 24" 24" min /48" max 45 degree to 90 degree; 3 2 6 0 0 WHDR -400 SUPPLY 100IN PERIMETER (2) ADP 10" fuel depth DUCT NOZZLE 0 1/2" • REMOTE PULL STATION 87- 120050 -001 ADP Upright Broiler/ 30.25" X 34" n/a within top 4" of 1 1 1 0 0 LINE Salamanders TANK #3 broiler compartment ® TANK #4 = NONE SUPPLY LINE F Single Vat Fryer 18" X 18" 27" min /45" max 45 degree to 90 degree 2 0 0 1 2 (drip boards 1 to 6) © MECHANICAL PULL STATION R Range 28" x 28" 20" min /42" max 9" radius from midpoint 1 0 0 1 1 TOTAL FLOW POINTS 10 1 5 MFG: KIDDE — FENWALL GENERAL NOTES MAXIMUM FLOW POINTS: For piping allowances and balances WHDR125: 4 Flow Points U L3 0 0 refer to KIDDE — FENWALL Technical WHDR260: 8 Flow Points Manual —U.L. File EX3559. WHDR400: 12 Flow Points The System installation shall conform WHDR600: 18 Flow Points to the requirements of NFPA #17A & 96 DUAL WHDR400: 24 Flow Points (manifolded) and all applicable State and Local Codes. KIDDE PARTS LEGEND SYMBOL DESCRIPTION KIDDE P/N APPLIANCE NOZZLE GRW, R. F, ADP, DESCRIPTION MANUFACTURER — DM, LPF, LPR L PLENUM NOZZLE ADP _ - 50IN PERIMETER ADP 10 DUCT NOZZLE WHDR -400 SUPPLY 100IN PERIMETER (2) ADP TANK DUCT NOZZLE 0 1/2" • REMOTE PULL STATION 87- 120050 -001 SUPPLY GAS VALVE •75 ", 1", 1.25 ", 1.5 ", ", ", TANK #2 2 2.5 3" 0 FIRE SYSTEM DESIGN SCHFDUI_E FIRE SYSTEM COMPONENTS O O 710 SOUTH POWERLINE ROAD CHIEF ENGINEER DEERFIELD BEACH, FL. 33442 MAX BRAND, P.E. �� O E —MAIL: HOODDEPOT(PAOL. COM PH# 800 - 322 -8730 °G"'c• LICENSE # 72500 REVISIONS AB EIRE EQUIPMENT 2759 19TH STREET POMPANO BEACH, F L NUMBER DESCRIPTION MANUFACTURER — KIDDE FIRE SYSTEMS 7/24/13 _ - -_ M'YNS AND BUNS 5748 SUNSET DR MIAMI, FL 10 TANK #1 = WHDR -400 SUPPLY LINE FOR TANK #1 0 1/2" 20 TANK #2 = WHDR -260 SUPPLY LINE FOR TANK #2 0318" O TANK #3 = NONE SUPPLY LINE FOR TANK #3 NONE ® TANK #4 = NONE SUPPLY LINE FOR TANK #4 NONE O CONTROL BOX = XV © MECHANICAL PULL STATION O 360' FUSIBLE LINK ® 450' FUSIBLE LINK 9O GAS VALVE = MECHANICAL 10 ADP NOZZLE 11 R NOZZLE 12 F NOZZLE 13 GRW NOZZLE 14 LPR NOZZLE 15 DM NOZZLE 16 LPF NOZZLE 17 K TYPE EXTINGUISHER (BY OWNER) HOOD #1 SIZE = 10'- 0"x60" HOOD #2 SIZE = 6'- 0"x45" APPLIANCE LAYOUT APPLIANCE TYPE O WOOD BURNING CHARBROILER © CHARCOAL —FIRED BROILER O 2 BURNER RANGE O FRYER O TURBOCHEF OVEN HOOD #1 EXHAUST DUCT SIZE = 32"x18" HOOD #2 EXHAUST DUCT SIZE = 1 1 "x1 1 " 2 OVERALL SIZE COOKING SURFACE 57"x34" 54 "x24" 37 "x28" 36 "x24" 12 "x24" 12 "x22" 16"x24" 15"x 14" 26"x30" NO, PROTECTION REQ'D GENERAL FIRE SYSTEM NOTES 1. NO GALVANIZED PIPE TO BE USED ONLY USE SCHEDULE 40 BLACK IRON STEEL PER NFPA # 17A 2 SYSTEM TO HAVE AUDIBLE /VISUAL DEVICE TO SOUND UPON ACTUATION OF FIRE SUPPRESSION SYSTEM. (INSTALLED AND PROVIDED BY ELECTRICIAN) 3. ALL HOOD PENETRATIONS TO BE WELDED LIQUID TIGHT OR SHALL USE A UL LISTED SEAL PER NFPA #1 7A 4. ALL MOTORS, LIGHTS AND OTHER ELECTRICAL DEVICES INSTALLED IN TYPE I DUCTS OR HOODS OR LOCATED IN THE PATH OF TRAVEL OF EXHAUST PRODUCTS ARE SPECIFICALLY APPROVED FOR SUCH USE 5. FIXED PIPE EXTINGUISHING SYSTEMS IN A SINGLE HAZARD AREA SHALL BE ARRANGED FOR SIMULTANEOUS AUTOMATIC OPERATION UPON ACTIVATION OF ANY ONE OF THE SYSTEM COMMON EXHAUST DUCT FOR MORE THAN ONE HOOD WOULD DEFINE A SINGLE HAZARD AREA EXCEPTION WOULD BE A SECONDARY FIRE SUPPRESSION SYSTEM CONTAINED IN THE COMMON EXHAUST. 0 HOOD AND FANS OPERATIONS NOTES FIRE MODE REQUIRES EXHAUST FAN CONTINUES TO OPERATE AND SUPPLY FAN STOPS. SUPPLY AND EXHAUST FANS ARE INTERLOCKED WITH PILOT LIGHTED SWITCH IN KITCHEN AREA. HOOD EXHAUST FANS SHALL OPERATE WHENEVER THE FIRE EXTINGUISHING SYSTEM IS ACTIVATED (EVEN WHEN HOOD SWITCH IS IN OFF POSITION). ALL ELECTRIC AND FUEL TO ALL EQUIPMENT AND RECEPTACLES UNDER HOOD TO SHUT DOWN UPON FIRE SYSTEM ACTIVATION SYSTEM TO HAVE REMOTE PULL STATION FOR MANUAL MEANS OF ACTUATION AND FUSIBLE LINKS FOR AUTOMATIC MEANS OF ACTUATION PER NFPA 17A -__/ P,� ` � fui3 OU t � •``�px B RA 40''� � i� •.. G E N •. No. 72500 _�• * :c- = z O� •W STATE OF •'4v 4 s ••....•• ,0•,, /ONA � 1, �.`. APPROVED BY OvA ENT RM►T / ASITE 110 _ O O 710 SOUTH POWERLINE ROAD CHIEF ENGINEER DEERFIELD BEACH, FL. 33442 MAX BRAND, P.E. �� O E —MAIL: HOODDEPOT(PAOL. COM PH# 800 - 322 -8730 °G"'c• LICENSE # 72500 REVISIONS AB EIRE EQUIPMENT 2759 19TH STREET POMPANO BEACH, F L NUMBER DESCRIPTION DATE 1 CHANGED HOOD D SIZE, COOKING EQUIPMENT 7/24/13 M'YNS AND BUNS 5748 SUNSET DR MIAMI, FL IN -3084 SCALE.- NOTED DRAWN BY- M. C. CHECK BY- R.Z. DATE.• 04/04/13 TITLE. FIRE SUPPRESSION SYSTEM 1 OF 2