1/2 "0 SCHD. 40 BLACK - IRON SUPPLY LINE 3/8 "0 SCHD. 40 BLACK - IRON SUPPLY LINE VENT PLUG 1/4" OD COPPER TUBE (1) WHDR -260 CYLINDER (1) WHDR -400 CYLINDER 16" 12" MI TO FUSIBLE LINKS AND REMOTE PULL STATION i TO GAS- VALVE XV CONTROL BOX CONTROL PANEL REMOTE FIRE CABINET HOOD & LIGHT SWITCH TO TANK #2 IN 10 10 REMOTE FIRE CABINET �r 1/16" S/S CABLE IN 1/2" EMT TO XV CONTROL BOX IN CABINET USE CORNER PULLEYS AT ALL CHANGE OF DIRECTIONS 0 0 0 0 0 FIRE SUPPRESSION ELEVATION VIEW CONTROL PANEL & DOUBLE MICROSWITCH PROVIDED BY HOOD DEPOT. CONTROL PANEL PRE -WIRED TO LIGHT SWITCH, HOOD SWITCH, AND 1 POLE OF FIRE SYSTEM MICROSWITCH. THE CONTROL PANEL IS PRE -WIRED TO SHUTDOWN MUA AND TURN ON EXHAUST IN CASE OF FIRE. ALL OTHER CONNECTIONS ARE TO BE MADE BY OTHERS. THERE IS (1) NO /NC MICROSWITCH AVAILABLE IN THE J -BOX FOR FIRE ALARM ACTIVATION. FOR OTHER REQUIREMENTS SUCH AS THE SHUTDOWN OF ELECTRIC APPLIANCES AND RECEPTACLES UNDER HOOD, GAS SOLENOID ACTIVATION, AND ANY OTHER REQUIREMENTS BY NATIONAL, STATE, OR LOCAL AUTHORITIES HAVING JURISICTION USE TERMINALS NC AND NO AS REQUIRED. NC /NO HAVE 115V /1PHASE AND ARE ACTIVATED UPON FIRE SYSTEM ACTUATION. NOTE: IF THERE IS NO BUILDING ALARM IT MAY BE REQUIRED TO PROVIDE A HORN TO BE SOUNDED UPON FIRE SYSTEM ACTUATION. CONTACT YOUR MUNICIPALITY FOR THEIR REQUIREMENTS. FIRE CABINET /FIRE. SYSTEM DETAILS KIDDE NOZZLE DETAIL RING PATTERN t - I I DM ADP F GRW R LPF LPR 0 1 2 3 4 1 &4 0 RINGS RING RINGS RINGS RINGS RINGS RINGS W/ DISC & CORE DUCT TEMPERATURE SENSOR DETAIL DUCT TEMPERATURE SENSOR TEMPERATURE SENSOR TO BE PLACED IN THE GREASE EXHAUST DUCT TO ACTIVATE THE EXHAUST HOOD SYSTEM PER FLORIDA MECHANICAL CODE 507.2.1.1 OPERATION. WHICH STATES TYPE I HOOD SYSTEMS SHALL BE DESIGNED AND INSTALLED TO AUTOMATICALLY ACTIVATE THE EXHAUST FAN WHENEVER COOKING OPERATIONS OCCUR. THE ACTIVATION OF THE EXHAUST FAN SHALL OCCUR THROUGH AN INTERLOCK WITH THE COOKING APPLIANCES, BY MEANS OF HEAT SENSORS OR BY MEANS OF OTHER APPROVED METHODS. TO SENSOR RELAY IN THE _ = HOOD DEPOT CONTROL PANEL D STEEL SCALE: 1/2" = V -0" 1/16" S/S CABLE IN 1/2" EMT TO XV CONTROL BOX IN CABINET USE CORNER PULLEYS AT ALL SEE PLAN VIEW I CHANGE OF DIRECTIONS FOR SPECIFIC LOCATION OF PULL STATION i I i I ;EMOTE FIRE CABINET I I I I I I I I I I I MECHANICAL GAS VALVE FIELD LOCATE AND j 9 --A CONNECT KIDDE WHDR SCHEDULE NOZZLE APPLICATION COVERAGE LENGTH OF DUCT PER NOZZLE SPECIAL NOTES FOR COVERAGE FLOW PAINTS ( TANK 1 No. F.P. TANK 2 No. F.P. ADP Duct 56' PERIMETER UNLIMITED N/A 1 0 0 1 1 (2) ADP Duct 100" PERIMETER UNLIMITED 2 ADP nozzles re 'd 1 2 2 0 1 0 NOZZLE APPLICATION COVERAGE NOZZLE HEIGHT (in Inches) SPECIAL NOTES FOR COVERAGE P AINTS f. .) 1 No. F.P. 2 No. F.P. ADP Plenum 10' x 4' N/A "V" Bank or Single 1 1 1 1 1 1 NOZZLE APPLICATION COVERAGE UMTATIONEFROM SPECIAL NOTES P INTS 1 2 - DM, LPF, LPR L COOKING SURFACE FOR COVERAGE f. ) No. F.P. No. F.P. DM Mesquite Charbroiler (chips, wood, logs) 30' X 24" " 24 min /48 max 45 degree to 90 degree; 3 2 6 0 0 REMOTE PULL STATION 87- 120050 -001 SUPPLY LINE GAS VALVE 10" fuel depth NONE ® 2 2.5 3 NONE SUPPLY LINE ADP Upright Broiler/ 30.25" X 34" n/a within top 4" of 1 1 1 0 0 © Salamanders STATION broiler compartment 7O 360' FUSIBLE LINK ® F Single Vat Fryer 18" X 18" 27" min /45" max 45 degree to 90 degree 2 0 0 1 2 (drip boards 1 to 6) R Range 28" x 28" 20" min /42" max 9" radius from midpoint 1 0 0 1 1 TOTAL FLOW POINTS 10 1 5 MFG: KIDDE — FENWALL GENERAL NOTES MAXIMUM FLOW POINTS: For piping allowances and balances WHDR125: 4 Flow Points L Z O O refer to KIDDE — FENWALL Technical WHDR260: 8 Flow Points J Manual —U.L. File EX3559. WHDR400: 12 Flow Points The System installation shall conform WHDR600: 18 Flow Points to the requirements of NFPA #17A & 96 DUAL WHDR400: 24 Flow Points (manifolded) and all applicable State and Local Codes. pit KIDDE PARTS LEGEND SYMBOL DESCRIPTION KIDDE P/N AB EIRE EQUIPMENT 2759 19TH STREET POMPANO BEACH, FL APPLIANCE NOZZLE GRW, R, F, ADP, SYSTEMS - DM, LPF, LPR L PLENUM NOZZLE ADP WHDR -400 50IN PERIMETER ADP #1 DUCT NOZZLE 20 TANK #2 = 100IN PERIMETER (2) ADP FOR .TANK DUCT NOZZLE 0318" • REMOTE PULL STATION 87- 120050 -001 SUPPLY LINE GAS VALVE .75 ", 1", 1.25 ", 1.5 ", ", ", ". NONE ® 2 2.5 3 FIRE SYSTEM DESIGN SCHEDULE FIRE SYSTEM COMPONENTS 10 ADP NOZZLE 11 R NOZZLE J u AB EIRE EQUIPMENT 2759 19TH STREET POMPANO BEACH, FL MANUFACTURER — KIDDE FIRE SYSTEMS - 17 K TYPE EXTINGUISHER (BY OWNER) 7/24/13 D TANK #1 = WHDR -400 SUPPLY LINE FOR TANK #1 0112" 20 TANK #2 = WHDR -260 SUPPLY LINE FOR .TANK #2 0318" 30 TANK #3 = NONE SUPPLY LINE FOR TANK #3 NONE ® TANK #4 = NONE SUPPLY LINE FOR TANK #4 NONE 50 CONTROL BOX = XV O FOOD WARMER 12"x24" NO PROTECTION REQ'D © MECHANICAL PULL STATION 7O 360' FUSIBLE LINK ® 450' FUSIBLE LINK 9O GAS VALVE = MECHANICAL 0 GENERAL FIRE SYSTEM NOTES 1. NO GALVANIZED PIPE TO BE USED ONLY USE SCHEDULE 40 BLACK IRON STEEL PER NFPA # 17A 2 SYSTEM TO HAVE AUDIBLE /VISUAL DEVICE TO SOUND UPON ACTUATION OF FIRE SUPPRESSION SYSTEM. (INSTALLED AND PROVIDED BY ELECTRICIAN) 3. ALL HOOD PENETRATIONS TO BE WELDED LIQUID TIGHT .OR SHALL USE A UL LISTED SEAL PER NFPA # 17A 4. ALL MOTORS, LIGHTS AND OTHER ELECTRICAL DEVICES INSTALLED IN TYPE I DUCTS OR HOODS OR LOCATED IN THE PATH OF TRAVEL OF EXHAUST PRODUCTS ARE SPECIFICALLY APPROVED FOR SUCH USE 5. FIXED PIPE EXTINGUISHING SYSTEMS IN A SINGLE HAZARD AREA SHALL BE ARRANGED FOR SIMULTANEOUS AUTOMATIC OPERATION UPON ACTIVATION OF ANY ONE OF THE SYSTEM COMMON EXHAUST DUCT FOR MORE THAN ONE HOOD WOULD DEFINE A SINGLE HAZARD AREA EXCEPTION WOULD BE A SECONDARY FIRE SUPPRESSION SYSTEM CONTAINED IN THE COMMON EXHAUST. HOOD AND FANS OPERATIONS NOTES FIRE MODE REQUIRES EXHAUST FAN CONTINUES TO OPERATE AND SUPPLY FAN STOPS. SUPPLY AND EXHAUST FANS ARE INTERLOCKED WITH PILOT LIGHTED SWITCH IN KITCHEN AREA. HOOD EXHAUST FANS SHALL ' OPERATE WHENEVER THE FIRE EXTINGUISHING SYSTEM IS ACTIVATED (EVEN WHEN HOOD SWITCH IS IN OFF POSITION). ALL' ELECTRIC AND FUEL TO ALL EQUIPMENT AND RECEPTACLES UNDER HOOD TO SHUT DOWN UPON FIRE SYSTEM ACTIVATION SYSTEM TO HAVE REMOTE PULL STATION FOR MANUAL MEANS OF ACTUATION AND FUSIBLE LINKS FOR AUTOMATIC MEANS OF ACTUATION PER NFPA 17A 0X B RA,y . .� •• C E NS •.• No. 72500 ? 'z O : STATE OF ;•LU x. NAL 2 ��Aj( O C-1) � 710 SOUTH POWERLINE ROAD CHIEF ENGINEER DEERFIELD BEACH, FL. 33442 MAX BRAND, P.E. O E —MAIL: HOODDEPOT @AOL. COM PH# 800 - 322 -8730 °qc" LICENSE # 72500 10 ADP NOZZLE 11 R NOZZLE J u AB EIRE EQUIPMENT 2759 19TH STREET POMPANO BEACH, FL 14 LPR NOZZLE 15 DM NOZZLE 16 LPF NOZZLE DATE 1 17 K TYPE EXTINGUISHER (BY OWNER) 0 GENERAL FIRE SYSTEM NOTES 1. NO GALVANIZED PIPE TO BE USED ONLY USE SCHEDULE 40 BLACK IRON STEEL PER NFPA # 17A 2 SYSTEM TO HAVE AUDIBLE /VISUAL DEVICE TO SOUND UPON ACTUATION OF FIRE SUPPRESSION SYSTEM. (INSTALLED AND PROVIDED BY ELECTRICIAN) 3. ALL HOOD PENETRATIONS TO BE WELDED LIQUID TIGHT .OR SHALL USE A UL LISTED SEAL PER NFPA # 17A 4. ALL MOTORS, LIGHTS AND OTHER ELECTRICAL DEVICES INSTALLED IN TYPE I DUCTS OR HOODS OR LOCATED IN THE PATH OF TRAVEL OF EXHAUST PRODUCTS ARE SPECIFICALLY APPROVED FOR SUCH USE 5. FIXED PIPE EXTINGUISHING SYSTEMS IN A SINGLE HAZARD AREA SHALL BE ARRANGED FOR SIMULTANEOUS AUTOMATIC OPERATION UPON ACTIVATION OF ANY ONE OF THE SYSTEM COMMON EXHAUST DUCT FOR MORE THAN ONE HOOD WOULD DEFINE A SINGLE HAZARD AREA EXCEPTION WOULD BE A SECONDARY FIRE SUPPRESSION SYSTEM CONTAINED IN THE COMMON EXHAUST. HOOD AND FANS OPERATIONS NOTES FIRE MODE REQUIRES EXHAUST FAN CONTINUES TO OPERATE AND SUPPLY FAN STOPS. SUPPLY AND EXHAUST FANS ARE INTERLOCKED WITH PILOT LIGHTED SWITCH IN KITCHEN AREA. HOOD EXHAUST FANS SHALL ' OPERATE WHENEVER THE FIRE EXTINGUISHING SYSTEM IS ACTIVATED (EVEN WHEN HOOD SWITCH IS IN OFF POSITION). ALL' ELECTRIC AND FUEL TO ALL EQUIPMENT AND RECEPTACLES UNDER HOOD TO SHUT DOWN UPON FIRE SYSTEM ACTIVATION SYSTEM TO HAVE REMOTE PULL STATION FOR MANUAL MEANS OF ACTUATION AND FUSIBLE LINKS FOR AUTOMATIC MEANS OF ACTUATION PER NFPA 17A 0X B RA,y . .� •• C E NS •.• No. 72500 ? 'z O : STATE OF ;•LU x. NAL 2 ��Aj( O C-1) � 710 SOUTH POWERLINE ROAD CHIEF ENGINEER DEERFIELD BEACH, FL. 33442 MAX BRAND, P.E. O E —MAIL: HOODDEPOT @AOL. COM PH# 800 - 322 -8730 °qc" LICENSE # 72500 10 ADP NOZZLE 11 R NOZZLE 12 F NOZZLE 13 GRW NOZZLE AB EIRE EQUIPMENT 2759 19TH STREET POMPANO BEACH, FL 14 LPR NOZZLE 15 DM NOZZLE 16 LPF NOZZLE DATE 1 17 K TYPE EXTINGUISHER (BY OWNER) 7/24/13 HOOD #1 SIZE = 10' -0 "x60" HOOD #1 EXHAUST DUCT SIZE = 32 %18" IN -3084 HOOD #2 SIZE = 4'- 0"x45" HOOD #2 EXHAUST DUCT SIZE = 9"x9" APPLIANCE LAYOUT SCALE.- NOTED DRAWN BY- M. C. APPLIANCE TYPE OVERALL SIZE COOKING SURFACE O WOOD BURNING CHARBROILER 57 "x34" 54"x24" © CHARCOAL —FIRED BROILER 37"x28" 36 "x24" O FRYER 16"x24" 15 "x 14" O 2 BURNER RANGE 12"x24" 12"x22" O FOOD WARMER 12"x24" NO PROTECTION REQ'D 0 GENERAL FIRE SYSTEM NOTES 1. NO GALVANIZED PIPE TO BE USED ONLY USE SCHEDULE 40 BLACK IRON STEEL PER NFPA # 17A 2 SYSTEM TO HAVE AUDIBLE /VISUAL DEVICE TO SOUND UPON ACTUATION OF FIRE SUPPRESSION SYSTEM. (INSTALLED AND PROVIDED BY ELECTRICIAN) 3. ALL HOOD PENETRATIONS TO BE WELDED LIQUID TIGHT .OR SHALL USE A UL LISTED SEAL PER NFPA # 17A 4. ALL MOTORS, LIGHTS AND OTHER ELECTRICAL DEVICES INSTALLED IN TYPE I DUCTS OR HOODS OR LOCATED IN THE PATH OF TRAVEL OF EXHAUST PRODUCTS ARE SPECIFICALLY APPROVED FOR SUCH USE 5. FIXED PIPE EXTINGUISHING SYSTEMS IN A SINGLE HAZARD AREA SHALL BE ARRANGED FOR SIMULTANEOUS AUTOMATIC OPERATION UPON ACTIVATION OF ANY ONE OF THE SYSTEM COMMON EXHAUST DUCT FOR MORE THAN ONE HOOD WOULD DEFINE A SINGLE HAZARD AREA EXCEPTION WOULD BE A SECONDARY FIRE SUPPRESSION SYSTEM CONTAINED IN THE COMMON EXHAUST. HOOD AND FANS OPERATIONS NOTES FIRE MODE REQUIRES EXHAUST FAN CONTINUES TO OPERATE AND SUPPLY FAN STOPS. SUPPLY AND EXHAUST FANS ARE INTERLOCKED WITH PILOT LIGHTED SWITCH IN KITCHEN AREA. HOOD EXHAUST FANS SHALL ' OPERATE WHENEVER THE FIRE EXTINGUISHING SYSTEM IS ACTIVATED (EVEN WHEN HOOD SWITCH IS IN OFF POSITION). ALL' ELECTRIC AND FUEL TO ALL EQUIPMENT AND RECEPTACLES UNDER HOOD TO SHUT DOWN UPON FIRE SYSTEM ACTIVATION SYSTEM TO HAVE REMOTE PULL STATION FOR MANUAL MEANS OF ACTUATION AND FUSIBLE LINKS FOR AUTOMATIC MEANS OF ACTUATION PER NFPA 17A 0X B RA,y . .� •• C E NS •.• No. 72500 ? 'z O : STATE OF ;•LU x. NAL 2 ��Aj( O C-1) � 710 SOUTH POWERLINE ROAD CHIEF ENGINEER DEERFIELD BEACH, FL. 33442 MAX BRAND, P.E. O E —MAIL: HOODDEPOT @AOL. COM PH# 800 - 322 -8730 °qc" LICENSE # 72500 REVISIONS AB EIRE EQUIPMENT 2759 19TH STREET POMPANO BEACH, FL NUMBER DESCRIPTION DATE 1 CHANGED HOOD GSIZE. COOKING EQUIPMENT 7/24/13 JffrYNS AND BUNS 5748 SUNSET DR MIAMI, FL IN -3084 SCALE.- NOTED DRAWN BY- M. C. CHECK BY. R. Z. DATE.• 04/04/13, TITLE.• FIRE SUPPRESSION SYSTEM 1 OF 2