13-406-024MEN' RESTROOM REMOTE FIRE CABINET W/ ACCESS DOOR Wagim rorsialm SWITCH PANEL 1 LIGHT, 1 FAN HOOD #1 13 13 13 13 12 --------------- --------- 8 REMOTE PULL AS N S T 0 INSTALLED 0 48 OF F.F. 3 F ALONG PATH RESS PART# 875572' NFW DINING AREA FRONT ENTRANCE FIRE SYSTEM PARTIAL FLOOR PLAN EXISTING SIDEWALK FIRE SYSTEM DESIGN- SCHEDULE FIRE SYSTEM COMPONENTS MANUFACTURER — KIDDE FIRE SYSTEMS FRYER 16"x24" 15"xl 4" OTANK #1 = WHDR-400 SUPPLY LINE FOR TANK #1 0112-11 TANK #2 = NONE SUPPLY LINE FOR TANK #2 NONE TANK #3 = NONE SUPPLY LINE FOR TANK #3 NONE TANK #4 = NONE SUPPLY LINE FOR TANK #4 NONE CONTROL BOX = XV INDIVIDUALLY ALL SUPPLY FANS MUST SHUT CONTRACTOR @) MECHANICAL PULL STATION ACTIVATIONS. THIS CAN BE ACCOMPLISHED 1. WIRE EACH FAN CIRCUIT FROM CIRCUIT 0 360* FUSIBLE LINK (70 450* FUSIBLE LINK SPARE SET OF CONTACTS WE HAVE ON OUR CONTROL PANEL. @) GAS VALVE = MECHANICAL CONTACT THE FACTORY FOR YOUR SPECIFIC 2. WIRE EACH FAN FROM LOAD SIDE • SCENARIO. ADP NOZZLE 11 R NOZZLE @ F NOZZLE DISCONNECT SWITCHES ON FAN. DISCONNECT 13 GRW NOZZLE LPR NOZZLE 15 DM NOZZLE 16 LPF NOZZLE SENSOS THEY NEED T-1j, I ARE MULTIPLE HEAT R a K TYPE EXTINGUISHER (BY OWNER) TERMINALS L AND N IN CONTROL PANEL. BE WIRED IN PARALLEL. 4. WIRE FROM CONTROL PANEL TERMINALS 9. LIGHTS ARE PRE WIRED ON TOP OF HOOD #1 SIZE = 12'—O"x60" HOOD #1 EXHAUST DUCT SIZE = 32"08" APPLIANCE LAYOUT APPLIANCE TYPE OVERALL SIZE COOKING SURFACE FRYER 16"x24" 15"xl 4" RADIANT CHARBROILER 36"x24 34"x2l DOUBLE CONVECTION OVEN 38x39 NO PROTECTION REQ'D REQUIREMENTS By 7. IF ANY OTHER NEW OR EXISTING HOOD SYSTEMS ARE WITHIN THE SAME ROOM AS ELECTRICAL EACH OTHER AND THEY OPERATE INDIVIDUALLY ALL SUPPLY FANS MUST SHUT CONTRACTOR DOWN UPON ANY OF THE FIRE SYSTEMr..' ACTIVATIONS. THIS CAN BE ACCOMPLISHED 1. WIRE EACH FAN CIRCUIT FROM CIRCUIT THROUGH SHUNT TRIP BREAKERS OR A BREAKER TO LINE SIDE OF CONTACTOR IN SPARE SET OF CONTACTS WE HAVE ON OUR CONTROL PANEL. FIRE RELAY" IN OUR CONTROL PANEL. CONTACT THE FACTORY FOR YOUR SPECIFIC 2. WIRE EACH FAN FROM LOAD SIDE • SCENARIO. CONTACTOR IN CONTROL PANEL TO FAN ♦ HEAT SENSORS NEED TO BE WIRED DISCONNECT SWITCHES ON FAN. DISCONNECT FROM EACH HOOD COLLAR TO THE CONTROL,*,,: SWITCHES PROVIDED ON FANS. 1­4 PANEL TERMINALS 4 AND 5. WHEN THERE '*_. 3. WIRE A 120V 20 AMP CIRCUIT To_ SENSOS THEY NEED T-1j, I ARE MULTIPLE HEAT R a TERMINALS L AND N IN CONTROL PANEL. BE WIRED IN PARALLEL. 4. WIRE FROM CONTROL PANEL TERMINALS 9. LIGHTS ARE PRE WIRED ON TOP OF NO AND N TO O- .O, DEVICE IN EACH HOOD TO A SINGLE JUNCTION BOX. JUMPERS NEED TO BE PROVIDED AND KITCHEN. 120V r' It DEVICE TO BE INSTALLED IN BETWEEN HOOD SECTIONS AND PROVIDED BY ELECTRICAL CONTACTOR. FROM THE NEAREST HOOD TO THE CONTROC PANEL AND WIRE TO TERMINALS 14 AND 5. WIRE FROM CONTROL PANEL TERMINALS NO AND N TO SHUNT TRIP BREAKERS IN 10. WHEN THERE IS NOT ♦ FIRE CABINET CIRCUIT BREAKER PANEL. ALL ELECTRIC BUILT INTO OUR HOOD THE MICRO SWITCH RECEPTACLES OR HARDWIRED APPLIANCES MUST BE WIRED FROM THE FIRE SYSTEM UNDER THE HOOD OR FEEDING EQUIPMENT CONTROL BOX TO OUR CONTROL PANEL. THE UNDER THE HOOD NEED TO SHUT DOWN COM WIRE (BLUE) GOES TO TERMINAL C IN UPON FIRE SYSTEM ACTIVATION. SHUNT TRIP OUR PANEL, THE NORMALLY CLOSED WIRE BREAKERS PROVIDED BY ELECTRICAL (YELLOW) GOES TO TERMINAL NC IN OUR CONTRACTOR. PANEL AND THE NORMALLY OPEN WIRE 6. FIRE ALARM CONNECTIONS —IF A FIRE (BROWN) GOES TO TERMINAL 3 IN OUR ALARM IS PRESENT IT NEEDS TO BE CONTROL PANEL. CONNECTED TO A SPARE MICRO SWITCH WE 0 BR,470 o A*o \V HAVE AT THE FIRE SYSTEM CONTROL HEAD. 4, ........ E N IF AN ALARM IS PRESENT ► HORN/STROBE DEVICE IS NOT REQUIRED. No. 72500 • :cc:= APR 15 z • STATE • % 0 • 710 SOUTH POWERLINE ROAD CHIEF ENGINEER DEERFIELD BEACH, FL. JJ442 MAX BRAND, P.E. irl E—MAIL: HOODDEPOTOAOL.COM PHj 800—J22-87JO LICENSE j 72500 E2=: DESCRIPTION FIRE EQUIPMENT 2759 19TH STREET POMPANO BEACH, FIL w