13-188-001FIRE REVEW DISAPPROVAL COMMENT RESPONSE SHEET
FOR PERMIT APPLICATION 13 -188 5748 SUNSET DR ( SW 72st )
1. PROVIDE RESPONSE SHEET ADDRESSING EACH COMMENTS AND INDICATE
TELESCO THE SHEET IN WISH CORRECTION IS FOUND - IF NOT PROVIDED ORIGINAL FULL
ASSOCIATES, INC. REVIEW FEE WILL BE ASSESSED AGAIN.
RESPONSE: PLEASE SEE ATTACHED RESPONSE SHEET.
Architecture &
Interior Design NOTE: THIS IS A DEMOLITION PLAN ONLY A SET OF CONSTRUCTION PLANS IS
for the Hospitality FORTHCO WING FROM THIS OFFICE INAPROXAMETLY 3 - 4 WEEKS. THE FUTURE UCE
Industry WILL BE MERCANTILE GROUP M(RESTAURANT WITH UNDER 50 OCCUPANTS, LESS
NY License 031794 THAN 4, 000 SQ FT AND TRA VEL DISTANCE TO EXIT LESS THAN 75'
FL. Lic . # AA- 0002884
2. INDICATE ON PLANS THE TYPE OF OCCUPANCY AND THE OCCUPANT LOAD
Miami (Main) Office AS PER TABLE 7.3.1.2
1111 Kane Concourse RESPONSE: SEE SHEET D -0 UNDER PROJECT DATA FOR OCCUPANCY TYPE. SEE .SHEET
Suite 301
Miami Beach, FL 33154 D -0 UNDER EXIT DATA FOR EXISTING OCCUPANCY LOAD. MERCANTILE GROUP M
Tel 305.866.1014
Fax 305.866.3317 3. PROVIDE MINIMUM REQUIRED FLAME SPREAD CLASSIFICATION FOR
New York Office INTERIOR FINISH AS PER TABLE A.10.2.2
224 5 "' Avenue, 4`" Floor RESPONSE: SEE SHEET D -0 UNDER FIRE PROTECTION NOTES FOR FLAME SPREAD
New York, NY 20001 CLASSIFICATION
Tel 212 777 2052
Western NY Office . PROVIDE DOOR SCHEDULE WITH ALL REQUIRED INFORMATION AS PER
ce
190 Deerhurst Park Blvd SCT.7.2.1.2.4
Tonawanda, NY 14217 RESPONSE. THIS ISA SELECTIVE DEMOLITION. FOR EXISTING DOOR REQUIREMENTS
Tel 716 884 6100 REFER TO SHEET D -0 UNDER EXIT DATA
E -mail 5. PROVIDE EXIT SIGNS AND EMERGENCY LIGHTS THROUGH
tom(a-�restaurant- RESPONSE: SEE SHEET D -2. ON THE EXISTING /DEMOLITION CEILING PLAN FOR EXIT
design.com
SIGNS AND EMERGENCY LIGHTS THROUGHOUT. THEYARE TO REMAIN.
Website
www restaurant- 6. INDICATE IF THERE IS AN EXISTING FIRE SPRINKLER AND /OR FIRE ALARM
design.com SYSTEM - IF SO PROVIDE A CONCEPTUAL PLAN SHOWING THE LOCATION OF ALL
NEW AND EXISTING HEADS AND DEVICES.
RESPONSE': NO EXISTING FIRE SPRINKLER NEITHER FIRE ALARM SYSTEMARE IN THE
SPACE. SEE SHEET D -0 UNDER FIRE PROTECTION NOTES FOR FLAME FOR NOTE.
7. INDICATE THAT THE KITCHEN HOOD SYSTEM MEETS THE REQUIREMENTS
OF NFPA 96 AND THE FIRE SUPPRESSION SYSTEM MEETS THE REQUIREMENTS OF
NFPA 17A.
RESPONSE': THE GREASE HOOD IS SCHEDULED FOR DEMOLITION IN THIS
DEMOLITION PERMIT APPLICATION AND PLAN.
8. - ADDITIONAL COMMENTS MAY FOLOW ONCE ALL INFORMATION IS
PROVIDED.
RESPQ1y§g; YNDERSTOOD. PMA