Loading...
14-850-003I OR 2 HOUR FIRE RATED THROUGH 2 HOUR FIRE RATED THROUGH lirl 0 'SOS I PENETRATION FIRESTOP FOR (j, 30,01 PENETRATION FIRESTOP FOR SINGLE METAL PIPE THROUGH GYPSUM U '00 ci MULTIPLE METAL PIPE THROUGH CONCRETE FLOORS OR WALLS UL 0 L WALLS USING TREMSTOP WBM. Vow 0 USING TYRE- SHIELD. voot 0 F-RATING =1 AND 2 HR. F-RATING = 2 HR. WLI 147 T-RATING - 0 AND 1t2 HR. CAJ-1304 T-RATING = 0 HR. 2 3B 3B ........... 2 1. FLOOR OR WALL ASSEMBLY — 4 THICK CONCRETE, MAX AREA OF OPENING IS 288 SQ. IN. 2. COPPER PIPE: 4' DIA. (OR SMALLER) REGULAR (OR HEAVIER) COPPER. STEEL PIPE: So DIA. (OR SMALLER) SCHAO (OR HEAVIER) STEEL CONDUIT: 40 DIA. (OR SMALLER) EMT OR 60 DIA. (OR SMALLER) STEEL CONDUIT. COPPER TUBING: 4" DIA.(OR SMALLER) TYPE L(OR HEAVIER) COPPER. 1. 1 OR 2 - HOUR FIRE RATED GYPSUM WALLBOARD /STUD ASSEMBLY IRON PIPE: W DIA.(OR SMALLER) CAST OR DUCTILE IRON. MAX NUMBER OF PIPES WITH OPENING IS THREE (3). 2. A) STEEL PIPE - 6" DIAM.(OR SMALLER) SCH. 40 (OR HEAVIER) STEEL B) CONDUIT - 4" DIAM.(OR SMALLER) EMT OR RIGID STEEL 3 A) FORMING MATERIAL - (NOT SHOWN) - NOM. In THICK POLY URETHANE BACKER ROD FRICTION FITTED INTO OPENING. 3. TREMSTOPWBM - FILL MAX 3/4w ANNULUS AT A THICKNESS B) NOM. FYRE-SHIELD THICKNESS INSTALLED WITHIN OPENING. OF 1 (2 HR. F-RATING) OR 3/4r (I HR. F-RATING). /V2w NOTE: FOR WALL APPLY FYRE-SHIELD TO BOTH SURFACES OF WALL. 2 HOUR FIRE RATED THROUGH I OR 2 HOUR FIRE RATED THROUGH PENETRATION FIRESTOP FOR SINGLE fz PENETRATION FIRESTOP FOR R51 PLASTIC PIPE THROUGH 0 PLASTIC PIPE THROUGH VUL9 CONCRETE FLOORS OR WALLS U L GYPSUM WALLS USING USING BLAZEMASTER CAULK& FYRE-CAN SLEEVE e F-RATING = 2 HR. F-RATING = 2 HR. CAJ 2221 T-RATING 1-112 HR. WL2151 T-RATING =1 HR. 2 4 2 2 ..... ...... Id .......... Q. 3 1. PRE-RATED CONCRETE FLOORS OR BLOCK WALLS = MIN. 4-1W THICKNESS 1. PRE-RATED GYPSUM WALLBOARD/STUD ASSEMBLY. 2. PLASTIC PIPE - A) NOM. 2" DIAM. (OR SMALLER) SCH. 40 PVC PIPE. 2. PLASTIC PIPE - 3" DIA. OR 20 DIA. SCHAO PVC FOR USE B) NOM. 2' DIAM. (OR SMALLER) CPVC PIPE IN CLOSED OR VENTED PIPING SYSTEMS. THE ANNULAR SPACE RANGE SHALL BE MIN MIN 1/4r TO MAX 3V 3. FYRE-CAN SLEEVE/INTUMESCENT DEVICE: NOTE: FOR USE IN CLOSED (PROCESS OR SUPPLY) PIPING SYSTEMS. NOM. PIPE DIAM. OF ANNULAR 3. FORMING MATERIAL - FOAM BACKER ROD FIRMLY PACKED INTO THE OPENING DIAM. (IN.) DEVICE SIZE OPENING (IN.) SPACE (IN.) AS A PERMANENT FORM. 2 TS2 3-112 1/4 TO 7/8 3 TS3 4-3/4 1/2 TO 314 4. BLAZEMASTER CAULK & WALK - MIN 1/20 THICKNESS OF SEALANT APPLIED WITHIN OPENING, FLUSH TOP SURFACE OF FLOOR OR BOTH SURFACES OF 4. TREMSTOP WBM - MIN. 1/40 THICK SEALANT APPLIED AT WALL ASSEMBLY SLEEVE/PIPE AND SLEEVE/WALL INTERFACES. The above described assembly and 'Y19INHOO(O THE PRODUCTS USED IN THE ABOVE ASSEMBLY HAVE products have been tested and are based on both and anticipated past 3735 Green Rd. BEEN TESTED IN ACCORDANCE WITH THE FOLLOWING: performance criteria. tremco shall Beachwood, OH, 44122 ASTM E814 (UL1479) STANDARD TEST METHOD not be liable far any damages, direct FOR THROUGH PENETRATION FIRESTOPPING. or consequential, resulting from use • ASTM E119 (UL 263) STANDARD FOR FIRE TESTS of this material or design. tremoo OF BUILDING CONSTRUCTION AND MATERIALS. shall only be responsible for replacing DRAWING NOT TO SCALE material found to be defective. w a I OR a "A VA W NJ MNS-