09-834-0010 1 1 1 2 3 4 1 5 6 7 1 8 1 9__� 1u 1 11 ELECTRICAL NOTES: 12 13 14 15 18 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 U3V7 u 38 il V A 1) ALL WIRING IS "POWER LIMITED ". 2) ALL WIRING AS APPLICABLE SHALL BE : 14/2, 12/2, 12/4, 18/2 & 18/4 UL FPL CABLE OR THWN. 3) INSTALLATION ADDITIONS SHALL COMPY WITH THE 2004 FBC / MIAMI —DADE COUNTY & LOCAL AHJ CODES 4) INSTALLATION ADDITIONS SHALL COMPLY WITH NFPA 72 2002 ALL APPLICABLE CHAPTERS 5) INSTALLATION ADDITIONS SHALL COMPLY WITH NFPA 101 2003 ALL APPLICABLE CHAPTERS 6) INSTALLATION ADDITIONS SHALL COMPLY WITH THE NEC 2005 ALL APPLICABLE SECTIONS 7) CONDUIT AS REQUIRED SHALL BE 1/2" & 3/4" EMT RACEWAY SIZED FOR MAXIMUM OF 40% WIRE FILL ! FLEXIBLE METALLIC RACEWAY AS REQUIRED SHALL BE 1/2" MINIMUM SIZED FOR MAXIMUM OF 40% WIRE FILL 8) SYSTEM SHALL BE GROUNDED PER MANUFACTURERS SPECIFICATIONS AND THE NEC 2005 ARTICLE 250 9) ALL VISUAL DEVICES SHALL BE MOUNTED @ 80" AFF TO BOTTOM OF VISUAL PER ADA & NFPA 72 2002 10) SYSTEM COMPONENTS SHALL BE UL LISTED, MFR COMPATIBLE AND SUITABLE FOR FIRE SERVICE USE 1 1) COST OF THIS PROJECT IS LESS THAN S 5,000 12) THE FIRE ALARM EVACUATION SIGNAL SHALL BE TEMPORAL PER NFPA 72 2002 & NFPA 101 2003 13) ALL FIRE /SMOKE PARTITION PENETRATION(S) SHALL BE SEALED AS REQUIRED, WITH LISTED APPROVED FIRESTOP COMPOUND, TO MATCH PENETRATED STRUCTURE(S) FIRE RATING 14) • INITIATING CIRCUITS SHALL BE CLASS B, STYLE B • ALL NOTIFICATION APPLIANCE CIRCUITS SHALL BE CLASS B — STYLE Y 15) DUCT SMOKE DETECTORS IF APPLICABLE SHALL BE SUPERVISORY ANNUNCIATION ON[_Y, DUCT DETECTORS SHALL NOT INITIATE GENERAL ALARM 16) MANUAL PULL STATIONS SHALL BE MOUNTED @ 48" AFF 17) FIRE ALARM SYSTEM CONTROL SHALL BE MOUNTED AT FRONT ENTRANCE LOBBY PER PLAN @ 60" AFF ! FIRE ALARM CONTROL SHALL HAVE BUILT —IN ANNUNCIATOR 18) THE FIRE ALARM SYSTEM IS EXISTING AND SHALL BE REMOTE STATION / 24 HOUR STANDBY BATTERY REQUIRED 19) ALL VISUALS SHALL BE SYNCRONIZED @ 1 HZ PER ADA AND NFPA 72 20) THE MAXIMUM NUMBER OF POWERED DEVICES FOR EACH INITIATION CIRCUIT IS: 20 21) THE BUILDING IS NOT FIRE PROTECTION SPRINKLERED 22) ALL HVAC & FAN COIL UNITS GREATER THAN 2,QOOCFM HAVE BEEN PROTECTED. 23) AUDIBLE SIGNAL SHALL BE MINIMUM OF 75 dB OR 15dB ABOVE THE AVERAGE AMBIENT SOUND LEVEL OR 5dBA ABOVE THE MAXIMUM SOUND LEVEL HAVING A DURATION OF AT LEAST 60 SECONDS (WHICHEVER IS GREATER), MEASURED 5ft A.F.F. IN THE OCCUPIABLE AREA CEILING CHARACTERISTICS: i ALL CEILINGS ARE LESS THAN 10' AND ARE FLAT PROJECT SOPE OF WORK: • INSTALL ADDITIONAL FIRE ALARM DEVICES PER MASTER PERMIT SCOPE OF WORK SYMBOL DESCRIPTION MODEL MANUFACTURER E FAC FIRE ALARM CONTROL MFA -6024 NAPCO E Esq FIRE SYSTEM REMOTE ANNUNCIATOR RP -6000 NAPCO E. FAC NAC BOOSTER POWER SUPPLY SK -5495 SILENT KNIGHT OP PHOTO SMOKE SENSOR 429CT ESL /GE E MANUAL STATION RED — S/A BG -12 FIRELITE E\ 0 AUDIBLE VISUAL 24VDC 75CD — RED 1 HZ P2475 —W SYSTEM SENSOR E\ � �0 VISUAL ONLY 24VDC 75CD — RED 1 HZ 52475 —W SYSTEM SENSOR DD P DUCT MOUNTED PHOTO SMOKE DETECTOR DI- 1100ACDC SYSTEM SENSOR N\0 AUDIBLE VISUAL 24VDC MULTI —CD — RED 1 HZ P2R SYSTEM SENSOR N\ VISUAL ONLY 24VDC MULTI —CD — RED 1 HZ SR SYSTEM SENSOR cad A FIRE A SYSTEM IS 4 U .� 5 d 0 O v a 0 rr j L L d z a 0 O 0 E N NEW E = EXISTING ER = EXISTING RELOCATED WP = WEATHERPROOF SECTION A -A 1. Wall Assembly -- The 1 or 2 hr fire —rated gypsum wallboard /stud wall assgjnbly shall be constructed of the materials and in the manner specified in the individual U300 or U400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features: A. Studs -- Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. lumber spaced 16 in. OC. Steel studs to be min 2 -1/2 in• wide and spaced max 24 in. OC. When steel studs are used and the diam of opening exceeds the width of stud cavity, the opening shall be framed on all sides using lengths of steel stud installed between the vertical studs and screw— attached to the steel studs at each end. The framed opening in the wall shall be 4 to 6 in. wider and 4 to 6 in. higher than the diam of the penetrating item such that, when the penetrating item is installed in the opening, a 2 to 3 in. clearance is present between the penetrating item and the framing on all four sides. B. Gypsum Board* -- 5/8 in. thick, 4 ft wide with square or tapered edges. The gypsum board type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual U300 or U400 Series Design in the UL Fire Resistance Directory. Max diam of opening is 32-1/4 in. for steel stud walls. Max diam of opening is 14 -1/2 in. for wood stud walls. The F Rating of the firestop system is equal to the fire rating of the wall assembly. 2. Through— Penetrants -- One metallic pipe, conduit or tubing to be installed either concentrically or eccentrically within the firestop system. The annular space shall be min 0 in. to max 2 -1/4 in. Pipe may be installed with continuous point contact. Pipe, conduit or tubing may be installed at an angle not greater than 45 degrees from perpendicular. Pipe, conduit or tubing to be rigidly supported on both sides of wall assembly. The following types and sizes of metallic pipes, conduits or tubing may be used: A. Steel Pipe -- Nom 30 in diam (or smaller) Schedule 10 (or heavier) steel pipe. B. Iron Pipe -- Nom 30 in, diam (or smaller) cast or ductile iron pipe. C. Conduit -- Nom 4 in diam (or smaller) steel electrical metallic tubing or 6 in. diam steel conduit. D. Copper Tubing -- Nom 6 in. diam (or smaller) Type L (or heavier) copper tubing. E. Copper Pipe -- Nom 6 in. diam (or smaller) regular (or heavier) copper pipe. 3. Fill, Void or Cavity Material* -- Sealant -- Min 5/8 in. thickness of fill material applied within the annulus, flush with both surfaces of wall. At the point or continuous contact locations between pipe and wall, a min 1/2 in. diam bead of fill material shall be applied at the pipe wall interface on both surfaces of wall . HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC -- FS —One Sealant *Bearing the UL Classification Mark Reproduced by HILTI, Inc. Courtesy of FIREST4P SYSTEMS Underwriters Laboratodes, Inc. I IS V WIRING LEGEND DESCRIPTION COND SYMBOL ELECTRICAL TYPE cd CLASSIFICATION 2 CONDUCTOR 14 AWG FPLR CABLE Q? p V 1 ( +) RED, 1 ( —) BLACK a' 0 SIGNAL CIRCUIT OR B FPLR T_ 2 CONDUCTOR 14 AWG THWN 4) 1 ( +) RED, 1 ( —) BLACK L _0 -- EL Q R N 3) -•'� O INITIATION CIRCUIT 2 CONDUCTOR 18 AWG FPLR CABLE A FPLR AUXILIARY POWER CKT 2 CONDUCTOR 14 AWG FPLR /CMR CABLE P FPLR AUXILIARY POWER CKT 1 ( +) RED, 1 ( —) BLACK w cad WET LOCATION WIRING LEGEND, INCLUDING UNDERGROUND [300.5(B)] DESCRIPTION COND SYMBOL ELECTRICAL TYPE cd CLASSIFICATION 2 CONDUCTOR 14 AWG VNTC CABLE Q? p V 1 ( +) RED, 1 ( —) BLACK a' 0 SIGNAL CIRCUIT OR WB FPL T_ 2 CONDUCTOR 14 AWG THWN 4) 1 ( +) RED, 1 ( —) BLACK L _0 -- EL Q R N 3) -•'� O INITIATION CIRCUIT 2 CONDUCTOR 18 AWC VNTC SHIELDED CABLE WA FPL AUXILIARY POWER CKT 2 CONDUCTOR 14 AWG VNTC CABLE WP FPL � 0 1 ( +) RED, 1 ( —) BLACK w cad A FIRE A SYSTEM IS EXISTING AND SHALL BE REMOTE STATION MONITORED PER MDFR ORDINANCE FIRE ALARDA SYS17EM TO BE iNSTALLED 11?1 ACCORDANCE Wri"14 NFPA 71; 70 101- �t N ..: s i .. �,1.r•�t o REWORK DRAWINGS Z FIRE ❑ ELECTRICAL DATE: 07 -20 -2009 U U rJ U U V System No. C —AJ -1226 F RATING = 3 —HR. T RATING = 0 —HR. L Rating At Ambient — Less than 1 CFM /Sq Ft U U L Rating At 400 F — 4 CFM /Sq Ft .... U U A 3 413 F_ 46 1 2 iV 4A 3 �A SECTION A —A 1. Floor or Wall Assembly Min 4 -1/2 in. thick reinforced lightweight or normal weight (100 -150 pcf) concrete. Wall may also be constructed of any UL Classified Concrete Blocks *. Max diam of opening is 32 in. 2. Metallic Sleeve (Optional) Nam 32 in. diam (or smaller) Schedule 40 (or heavier) steel sleeve cast or grouted into floor or wall assembly, flush with floor or wall surfaces. 3. Through- Penetrant One metallic pipe or conduit to be installed either concentrically or eccentrically within the firestop system. The annular space between pipe or conduit and periphery of opening shall be min 0 in. (point contact) to max 1 -7/8 in. Pipe may be installed with continuous point contact. Pipe or conduit to be rigidly supported on both sides of floor or wall assembly. The following types and sizes of metallic pipes or conduits may be used: A. Steel Pipe Nom 30 in. diarn (or smaller) Schedule 10 (or heavier) steel pipe. B. Iron Pipe Nom 30 in. diam (or smaller) cast or ductile iron pipe. C. Copper Pipe Norrl 6 in. diam (or smaller) Regular (or heavier) copper pipe. D. Copper Tubing Nom 6 in. diam (or smaller) Type L (or heavier) copper tubing. E. Conduit Nom 6 in. diam (or smaller) steel conduit. F. Conduit Nam 4 in. diam (or smaller) steel electrical metallic tubing (EMT). 4. Firestop System The firestop system shall consist of the following: A. Packing Material Min 4 in. thickness of min 4 pcf mineral wool batt insulation firmly packed into opening as a permanent form. Packing material to be recessed from top surface of floor or from both surfaces of wall as required to accommodate the required thickness of fill material. B. Fill, Void or Cavity Material* -- Sealant Min 1/4 in, thickness of fill material applied within the annulus, flush with top surface of floor or with both surfaces of wall. At the point or continuous contact locations between pipe and concrete, a min 1/4 in, diam bead of fill material shall be applied at the concrete /pipe interface on the top surface of floor and on both surfaces of wall. HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC - FS -One Sealant *Bearing the UL Classification Marking ��II 5 I Fj�o Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. FIREiiOP SYSTEMS c YL Us 80" A.F.F. OR 6" BELOW CEILING — (WHICHEVER IS LOWER) STROBE OR HORN /STROE PULL STATIO 48" A.F.F. ADA HEIGHT REQUIREMENTS NO SCALE U e U V U V U U U U U C I 0 1 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 r 24 25 26 27 28 29 ':,31 32 33 34 35 36 37 38 39 , F G H J K L M N 0 0 9 0 S UNITED FIRE COMMUNICATIONS E F0001087 701 S.W. 27 AVENUE - M33 MIAMI, FLORIDA 33135 PHONE (305) 541 -8375 RON IWSSE, SET CONTRACTOR AMSAFE of MIAMI, Inc P.Q. Box 550189 Fort Lauderdale, FL EF0000103 U_ Revisions No. Date Description 1 08 -18 -09 Fire Review Comments 2 07 -20.09 Fire Review Comments T U 4 V W 0/ Z 1 A - i