10-920-024Q vi L V) z off.. w a. 0 0 CL GENERAL. NOTES 1. CONTRACTOR SHALL FIELD VERIFY EXISTING SEWER UTILITY CONNECTION SIZE, LOCATION, SLOPE, DIRECTION OF FLOW, AND INVERT PRIOR TO BEGINNING CONSTRUCTION. CONTRACTOR SHALL IMMEDIATELY NOTIFY ENGINEER OF ANY DISCREPANCIES BETWEEN THE PLANS AND ACTUAL FIELD CONDITIONS. 2. CONTRACTORS SHALL FIELD VERIFY EXISTING WATER UTILITY CONNECTION SIZE, AND LOCATION PRIOR TO BEGINNING CONSTRUCTION. CONTRACTOR SHALL IMMEDIATELY NOT�FY ENGINEER OF ANY DISCREPANCIES BETWEEN THE PLANS AND ACTUAL FIELD CONDITIONS. 3. PLUMBING CONTRACTOR T COORDINATE EXACT STREET WATER PRESSURE AND NOTIFY ENGINEER OF ANY DISCREPANCIES. CONTRACTOR SHALL PROVIDE A PRESSURE REDUCING VALVE (PRV) IF STREET WATER PRESSURE EXCEEDS 80 PSI. PRV SHALL BE INSTALLED ON BUILDING SIDE OF WATER METER AND SET TO 80 PSI. 4. CONTRACTOR TO FIELD VERIFY EXISTING DOMESTIC WATER SYSTEM IS PROVIDED WITH A REDUCED PRESSURE BACKFLOW PREVENTER (RPBP). IF NOT EXISTING, PROVIDE AN APPROVED RPBP ASSEMBLY SIZED TO MATCH BUILDING WATER METER. INSTALL NEW RPBP BETWEEN THE WATER METER AND THE BUILDING PERK LOCAL J.URISDICTION'S REQUIREMENTS. 5. CONTRACTOR SHALL MAINTAIN ALL WARRANTIES ASSOCIATED WITH ROOF FOR ALL ROOF PENETRATIONS. KITCHEN GENERAL NOTES 1. REFER TO K.E.C. DRAWINGS FOR ADDITIONAL WORK REQUIRED (INDIRECT WASTE PIPING, ETC.) AND FOR ALL EQUIPMENT SCHEDULES, AND SPECIFICATIONS. 2. REFER TO K.E.C. ROUGH -IN DRAWINGS AND COORDINATE WITH CONTRACTOR EXACT LOCATIONS OF EQUIPMENT AND FLOOR SINK LOCATIONS, PLUMBING ROUGH -IN HEIGHTS, ETC. 3. ALL FLOOR SINKS HAV HALF GRATE UNLESS NOTED OTHERWISE. FLOOR. SINKS LOCATED BELOW I EQUIPMENT SHALL BE RAISED 1/4" MIN. A.F.F. OR AS DIRECTED BY LOCAL JURISDICTION. 4. PROVIDE CHROME PLATED STOP VALVES AT EACH REQUIRED EQUIPMENT WATER CONNECTION. PROVIDED BUTTERFLY VALVE AT EACH REQUIRED EQUIPMENT GAS CONNECTION. PROVIDE CHROME PLATED P -TRAP, TAILPIECE AND ESCUTCHEON AT EACH REQUIRED EQUIPMENT DIRECT WASTE CONNECTION. FOR EACH REQUIRED EQUIPMENT INDIRECT, WASTE PIPING CONNECTION. ROUTE INDIRECT WASTE PIPING FROM EQUIPMENT TO NEAREST FLOOR SINK PER K.E.C.I DWGS. INDIRECT WASTE PIPING: COPPER TYPE "DWV" WITH SOLDERED END DRAINAGE FITTINGS. 5. ALL DIRECT CONNECT EQUIPMENT SHALL BE PROVIDED WITH BACKFLOW PREVENTION "CARBONATOR" TYPE SODA DISPENSERS ARE CONSIDERED TO BE "HIGH HAZARD" APPLIANCES AND SHALL BE PROTECTED BY A STAINLESS STEEL REDUCED PRESSURE PRINCIPLE BACKFLOW PREVENTER. (WATTS SS009 OR EQUAL). ALL OTHER APPLIANCES SUCH AS ICE MACHINES, COFFEE- MAKERS, YOGURT DISPENSERS, AND SIMILAR EQUIPMENT WITH DIRECT CONNECTIONS TO POTABLE WATER SHALL BE PROTECTED BY A DOUBLE CHECK VALVE TYPE BACKFLOW PREVENTER (WATTS 007 OR EQUAL). 6. ALL INDIRECT WASTE PIPING INSTALLED WITH A LENGTH GREATER THAN 5' -0" SHALL HAVE A CLEANOUT PROVIDED. MAXIMUM LENGTH OF INDIRECT WASTE LINE SHALL BE 15' -0 "1 71 ALL HAND SINKS /LAVATORIES SHALL BE PROVIDED WITH A THERMO- STATIC MIXING VALVE TO SUPPLY TEMPERED HW, MAX. 110 DEG. HW. INVESTIGATION OF CONDITIONS EXAMINE THE CONTRACT DRAWINGS AND ALL AVAILABLE INFORMATION CONCERNING EXISTING INSTALLATION, STRUCTURE, AND LOCAL CONDITIONS. VISIT THE SITE TO UNDERSTAND THE NATURE�AND SCOPE OF ALL WORK TO BE PERFORMED AND VERIFY EXISTING CONDITIONS. THE SUBMISSION OF A BID WILL BE TAKEN AS EVIDENCE THAT SUCH AN EXAMINATION HAS BEEN MADE AND THAT ALL EXISTING CONDITIONS HAVE BEEN CONSIDERED. NO ALLOWANCES WILL BE MADE AFTER THE PROJECT HAS BEEN AWARDED FOR FAILURE TO VERIFY EXISTING CONDITIONS. CONTRACTOR SHALL NOTIFY ENGINEER OF ANY DISCREPANCIES BETWEEN ACTUAL FIELD CONDITIONS AND THAT OF THESE DRAWINGS PRIOR TO .BEGINING CONSTRUCTION. .NOTE: GENERAL CONTRA A RESPONSIBILITY TO VERIFY EXACT LOCATION & DEPTH OF EXISTING WASTE LINE DURING FIELD VISIT /BID PROCESS NOTE: ALL WALL PENETRATIONS INTO A FIRE RATED ASSEMBLY SHALL NOT BE LARGER THAN 4" NOMINAL PIPE OR 16 SQUARE INCHES IN OVERALL CROSS - SECTIONAL AREA WITH AN AGGREGATE AREA NOT MORE THAN 100 SQUARE INCHES FOR ANY 100 SQUARE FEET. NOTE: PLUMBING CONTRACTOR MUST PROVIDE CAMERA VERIFICATION OF EXACT LOCATION OF WASTE LINE TO GC DURING BID. VERIFICATION MUST BE MADE PRIOR TO ISSUANCE OF PERMIT AND AFTER ACCEPTANCE OF CONTRACT TO PROCEED. NOTE: PLUMBING CONTRACTOR IS RESPONSIBLE FOR THE INSTALLATION OF THE GLYCOL SYSTEM. MATERIALS FOR GLYCOL SYSTEM WILL BE PURCHASED BY KES IN KITCHEN PACKAGE. NOTE: MENS AND WOMENS RESTROOM MUST COMPLY WITH HANDICAP ACCESSIBILITY. L ---------- ; NOTE: -- ---- =- GLYCOL UNIT ON ROOF. CLOSED LOOP COOLING i SYSTEM PROVIDED TO COOL YOGURT MACHINES e i L----- - - - - -j POMESTIC WATER PIPING PLAN SCALE: 1/4" = V -0" i C ,AL TANK STATE STRIES WATER HEATER VE) SINK SHEET P2.1 FOR JRT /GLYCOL CONNECTION 'WASTE PIPING PLAr-_ SANITARYY, SCALE: 1/4" = V -0" aELF DINED WALK -IN :RS, NO FLOOR REQUIRED GT2700 -50 aE TRAR3 -COMP TO DRAIN TO 'E TRAP - 50/100 DE VENTING PER SPECS q PREP SINK AND )MP SINK INDIRECT LOOR SINKS BELOW W/H TO MOP BELOW I INDIRECT COLD STATION >ENSATE TO R SINK N^ rnd H U W W z Wp0Q X CL�Wa- � U _. z - n ad " ~ c10 z z�z d wd °�.nrn> Q z -J � Lo u, Ln -r- c) Q z rn d- U) .-J z Q d ® -t- d W Q �o q-0 d= U ui W ¢ 00� ©`-'z�c % E ��0 0 ME o) < < I M C�1 � 6 REVISION AFIRE COMMENTS 10 -22 -10 A FIRE COMMENTS 11 -10 -10 ACITY COMMENTS 4 -1 -11 I MENCHIE'S MENB549 i SHEET NAME NUMBER