10-920-0190 Lo GENERAL NOTES, Z) 1 ALL WORK SHALL BE INSTALLED, it'l ACCORDANCE WITH APPLICABLE BUILDING AND MECHANICAL CODES. ALL PLUMBING WORK SHALL BE INSTALLED IN ACCORDANCE WITH THE STATE PLUMBING CODE AND LOCAL BOARD OF V) HEALTH. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST z LANDLORD'S TENANT CRITERIA AND GUIDELINES. 2. LOCATIONS OF EXISTING PIPING;' DUCTWORK, AND MECHANICAL EQUIPMENT CL ARE BASED ON BEST AVAILABLE; INFORMATION, CONTRACTOR SHALL FIELD ui VERIFY EXACT LOCATIONS PRIOR TO COMMENCING WORK. cl- 3. REMOVE EXISTING MECHANICAL �ITEMS (EQUIPMENT, PIPING, DUCTWORK, ETC..) NOT REQUIRED IN REMODELED. A, RRANGEMENT. .REMOVE OR RELOCATE 0 PLUMBING ITEMS IN WALLS TO BE REMOVED AND AS NECESSARY TO 8 W- COORDINATE WITH REMODELED SPACES. EXISTING LOCATIONS OF ALL EXISTING 0- SANITARY, VENT AND WATER LINES MUST BE FIELD VERIFIED. MODIFY NEW LAYOUT AS REQUIRED TO COORDINATE WITH EXISTING CONDITIONS. PROVIDE OWNER WITH AS-BUILT PLANS OF ACTUAL INSTALLED SYSTEM. 4. ALL EXISTING PIPING NOT REUSED IN REMODELED SPACE SHALL BE CUT AND CAPPED IN CONCEALED LOCATIONS, FLUSH WITH FLOOR OR WALL. ALL UNUSED PIPING THAT IS NOT COMPLETELY CONCEALED SHALL BE REMOVED. DISCONNECTED PIPING TO REMAIN IN USE SHALL BE RECONNECTED TO BEST SUIT JOB CONDITIONS. 5. WHERE EXISTING WALLS ARE REMOVED, EXPOSED PIPING THAT WILL REMAIN IN USE SHALL BE OFFSET TO THE NEAREST AVAILABLE WALL AND RECONNECTED USING ALL NEW MATERIAL. THIS SHALL APPLY TO ALL PLUMBING PIPING OF BOTH KNOWN AND UNKNOWN LOCATIONS. 6. PROVIDE DIRT LEGS IN GAS PIPING AT EACH CHANGE IN ELEVATION AND AT CONNECTIONS TO APPLIANCES. PROVIDE ACCESSIBLE SHUTOFF VALVE AT EACH CONNECTION TO APPLIANCES OR EQUIPMENT WHERE APPLICABLE. 7. NOT USED 8. NOT USED 9. ALL ROOFING WORK SHALL BE PERFORMED BY LANDLORD DESIGNATED I ROOFING CONTRACTOR AT TENANT CONTRACTOR'S EXPENSE. 10. FIELD VERIFY (IF EXISTING) SMOKE EXHAUST/CONTROL SYSTEMS IN TENANT SPACE INCLUDING FANS, GRILLES, CONTROLS, ETC.. COORDINATE REQUIREMENTS WITH LANDLORD .1 PROVIDE WIRING TO LANDLORD'S FIRE ALARM SYSTEM AS DIRECTED BY LANDLORD, PROVIDE NEW EQUIPMENT, ACCESSORIES, WIRING, ETC.. AS REQUIRED FOR LANDLORD APPROVAL AND CODE COMPLIANCE. WIRE ROOF TOP FANS THRU RELAY TO STOP AIR CIRCULATION WHEN BUILDING FIRE ALARM SYSTEM IS ACTIVATED. 11. REFER I TO ARCHITECTURAL PLANS FOR LOCATIONS OF FIRE RATED WALLS, CEILINGS OR ROOF. FIRE DAMPERS AND ACCESS DOORS SHALL BE INSTALLED IN DUCTWORK WHEREVER DUCTWORK PENETRATES RATED CONSTRUCTION. SEAL AROUND ALL DUCT AND PIPE PENETRATIONS OF RATED CONSTRUCTION WITH FIRE RESISTANT SEALANT. 12. COORDINATE LOCATION, INSTALLATION, AND WIRING OF SENSORS AND THERMOSTAT(S) WITH BUILDING OWNER. 13. FIRE SPRINKLERS: ADDITIONS &,: MODIFICATIONS AS REQUIRED BY CODE AND NFPA PAMPHLET #13. SPRINKLER HEADS CENTERED WITHIN CEILING BOARD. ANY MODIFICATION TO BE DONE BY TENANT'S SPRINKLER CONTRACTOR. 14, MECHANICAL CONTRACTOR SHALL INSPECT EXISTING UNIT AND REPORT TO OWNER ANY SERVICE OR REPAIRS THAT ARE REQUIRED IN REGARD TO BELTS, REFRIGERANT CHARGE, COOLING COIL, FILTERS, ETC. 15. MECHANICAL COMPONENTS EXCEEDING 20 POUNDS IN WEIGHT SHALL HAVE THEIR CONNECTIONS TO THE BUILDING DESIGNED PER SECTION ASCE 7-05, CH. 13 � O NEW 5 TON RTU. GC TO OBTAIN MANUFACTURER SPECS DURING BID PROCESS. - GC TO CONSULT LANDLORD & STRUCTURAL ENGINEER FOR PLACEMENT. OEXHAUST FAN IN RESTROOM O NOT USED O NOT USED NOT USED O NOT USED 07 NEW WATER HEATER. SEE PLUMBING DRAWINGS 08 NEW THERMOSTAT ATTACHED TO EXISTING ROOF TOP UNIT. VERIFY OPERATION AND MOUNT AS SHOWN AT A HEIGHT OF 48-54" A.F.F. MECHANICAL EQUIPMENT SCHEDULE 1� A AIR 6E&Q COOLING TOTAL NOMINAL IT ES ELECTRI 29�& - MIN. ARI HEATIN2 — 0PE`,RA`nNG HEIGHT SYMBOL MANUFACTURER MODEL # TONS ItirAL. O'S'A' IES.P. MAX FAN HP UNIT MCA VOLT / # EFFICIENCY ENT. AIR AMB' CA PA ITY H ELECTRI�__ HEAT .., WEIGHT W1 CURB MB P = EL CFM, DB I WB RDIBEN–T , TOM SM KW USOTAGLS i CARRIER (5 TON) 5 2000 400 0.8 1.0 1 kBH 600 45' RTU-1 NEW 40 208 / 1 10.0 SEER 80-0 1651 0 110 51j.743.5 an NM CARRIER OR EQUAL - GC TO VERIFY ELECTRICAL SPECS F!JRNISH- WITH THE FOLLOWING: 1. PROGRAMMABLE THERMOSTAT, ECONOMIZER 2. PROGRAMMABLE THERMOSTAT, W/GRAVITY EXHAUST & DUAL ENTHAPY W/GRAVITY EXHAUST & DW CONTROL, OUTDOOR AIR DAMPER SECTION, CONTROL, OUTDOOR AIR DAN ROOF CURB POWER ENTRY KIT, ROOF BAROMETRIC RELIEF DAMPER MOUNTING FRAME, PREFAB ROOF CURB. PRE-FAB ROOF CURB, DUAL SMOKE DETECTORS ASSOCIATED WITH SMOKE DAMPERS AND HVAC SHUTOFFS SHALL BE TESTED BY AN APPROVED TESTING AGENCY OR A QUALIFIED THIRD PARTY SPECIAL INSPECTOR. THE SPECIAL INSPECTOR/TESTING AGENCY SHALL BE AN INDEPENDENT THIRD PARTY INDIVIDUAL OR FIRM AND SHALL NOT BE THE INSTALLING CONTRACTOR. A PROFESSIONAL ENGINEER SHALL SUBMIT A FINAL SIGNED AND SEALED REPORT TO THE MECHANICAL INSPECTOR PRIOR TO CITY ISSUANCE OF FINAL INSPECTION APPROVAL OR OCCUPANCY APPROVAL, INCLUDING CONDITIONAL OCCUPANCY APPROVAL." I I MATERIALS SPECS: 1 ALL MAINLINE DUCTWORK SHALL BE NO. 1 GRADE GALVANIZED STEEL, ASTM A-120, IN ACCORDANCE WITH SMACNA STANDARDS LATEST EDITION, CURRENT UNIFORM MECHANICAL CODE, AND WITH ASHRAE GUIDE RECOMMENDATIONS. 2. FLEXIBLE DUCTS TO DIFFUSERS SHALL BE THERMAFLEX TYPE M—KE OR EQUIVALENT GLENFLEX, CLASS 0 OR CLASS 1 WITH FLAME SPREAD RATING OF 25 AND A SMOKE DEVELOPED RATING OF 50. 3. ALL AIR CONDITIONING SUPPLY AIR DUCTS SHALL BE WRAPPED WITH A MINIMUM OF 1-1/2" DUCT INSULATION MEETING NFPA —90A. INSULATION SHALL BE 3/4 PCF DENSITY WITH FOIL SCRIM KRAFT FACING. ALL AIR CONDITIONING RECTANGULAR RETURN AIR DUCTS & PLENUMS SHALL BE LINED WITH 1" THICK, 1-1/2 PCIF JOHNS—MANVILLE "LINACOUSTIC R" OR EQUAL. 4. COIL CONDENSATE DRAINS SHALL BE TYPE "M" HARD DRAWN COPPER TUBING. INSULATE CONDENSATE DRAINS INSIDE BUILDING WITH 1/2" FLEXIBLE CLOSED CELL FOAMED PLASTIC PIPE INSULATION, ARMSTRONG ARMAFLEX AP, OR EQUAL, SECURED WITH ADHESIVE. FLAME SPREAD RATING NO GREATER THAN 25 AND SMOKE DEVELOPED RATING OF 50. MECHANICAL CONTRACTOR NOTE: GENERAL C&ITRACTOR IS REQUIRED TO PERFORM A TEST AND BALANCE AND DUCT DETECTOR TEST AND PROVIDE A CONFIRMATION REPORT PRIOR TO A FINAL INSPECTION. FYI'.c;TlNr, MFCHANICAI WAIT Wr UAWSWAN_bl DIFFUSER, GRILLE & A NOT USED CC TO LOCATE GLYCOL MACHINE IN A STRUCTURALLY SOUND APPROVED AREA - COORDINATE WITH LANDLORD SMOKE DUCT DETECTOR MOUNTED ON SUPPLY DUCT. INSTALL AND CONTROL KRUEGER 1400 WIRING (FROM DETECTOR TO UNIT) BY MECHANICAL CONTRACTOR. WHITE FURNISHED, POWER WIRING, AND FIRE ALARM INTERFACE WIRING (FROM RETURN DETECTOR TO FIRE ALARM PANEL) BY ELECTRICAL CONTRACTOR, AIR HANDLING UNIT SHALL SHUT DOWN UPON SENSING SMOKE. MECHANICAL EQUIPMENT SCHEDULE 1� A AIR 6E&Q COOLING TOTAL NOMINAL IT ES ELECTRI 29�& - MIN. ARI HEATIN2 — 0PE`,RA`nNG HEIGHT SYMBOL MANUFACTURER MODEL # TONS ItirAL. O'S'A' IES.P. MAX FAN HP UNIT MCA VOLT / # EFFICIENCY ENT. AIR AMB' CA PA ITY H ELECTRI�__ HEAT .., WEIGHT W1 CURB MB P = EL CFM, DB I WB RDIBEN–T , TOM SM KW USOTAGLS i CARRIER (5 TON) 5 2000 400 0.8 1.0 1 kBH 600 45' RTU-1 NEW 40 208 / 1 10.0 SEER 80-0 1651 0 110 51j.743.5 an NM CARRIER OR EQUAL - GC TO VERIFY ELECTRICAL SPECS F!JRNISH- WITH THE FOLLOWING: 1. PROGRAMMABLE THERMOSTAT, ECONOMIZER 2. PROGRAMMABLE THERMOSTAT, W/GRAVITY EXHAUST & DUAL ENTHAPY W/GRAVITY EXHAUST & DW CONTROL, OUTDOOR AIR DAMPER SECTION, CONTROL, OUTDOOR AIR DAN ROOF CURB POWER ENTRY KIT, ROOF BAROMETRIC RELIEF DAMPER MOUNTING FRAME, PREFAB ROOF CURB. PRE-FAB ROOF CURB, DUAL SMOKE DETECTORS ASSOCIATED WITH SMOKE DAMPERS AND HVAC SHUTOFFS SHALL BE TESTED BY AN APPROVED TESTING AGENCY OR A QUALIFIED THIRD PARTY SPECIAL INSPECTOR. THE SPECIAL INSPECTOR/TESTING AGENCY SHALL BE AN INDEPENDENT THIRD PARTY INDIVIDUAL OR FIRM AND SHALL NOT BE THE INSTALLING CONTRACTOR. A PROFESSIONAL ENGINEER SHALL SUBMIT A FINAL SIGNED AND SEALED REPORT TO THE MECHANICAL INSPECTOR PRIOR TO CITY ISSUANCE OF FINAL INSPECTION APPROVAL OR OCCUPANCY APPROVAL, INCLUDING CONDITIONAL OCCUPANCY APPROVAL." I I MATERIALS SPECS: 1 ALL MAINLINE DUCTWORK SHALL BE NO. 1 GRADE GALVANIZED STEEL, ASTM A-120, IN ACCORDANCE WITH SMACNA STANDARDS LATEST EDITION, CURRENT UNIFORM MECHANICAL CODE, AND WITH ASHRAE GUIDE RECOMMENDATIONS. 2. FLEXIBLE DUCTS TO DIFFUSERS SHALL BE THERMAFLEX TYPE M—KE OR EQUIVALENT GLENFLEX, CLASS 0 OR CLASS 1 WITH FLAME SPREAD RATING OF 25 AND A SMOKE DEVELOPED RATING OF 50. 3. ALL AIR CONDITIONING SUPPLY AIR DUCTS SHALL BE WRAPPED WITH A MINIMUM OF 1-1/2" DUCT INSULATION MEETING NFPA —90A. INSULATION SHALL BE 3/4 PCF DENSITY WITH FOIL SCRIM KRAFT FACING. ALL AIR CONDITIONING RECTANGULAR RETURN AIR DUCTS & PLENUMS SHALL BE LINED WITH 1" THICK, 1-1/2 PCIF JOHNS—MANVILLE "LINACOUSTIC R" OR EQUAL. 4. COIL CONDENSATE DRAINS SHALL BE TYPE "M" HARD DRAWN COPPER TUBING. INSULATE CONDENSATE DRAINS INSIDE BUILDING WITH 1/2" FLEXIBLE CLOSED CELL FOAMED PLASTIC PIPE INSULATION, ARMSTRONG ARMAFLEX AP, OR EQUAL, SECURED WITH ADHESIVE. FLAME SPREAD RATING NO GREATER THAN 25 AND SMOKE DEVELOPED RATING OF 50. MECHANICAL CONTRACTOR NOTE: GENERAL C&ITRACTOR IS REQUIRED TO PERFORM A TEST AND BALANCE AND DUCT DETECTOR TEST AND PROVIDE A CONFIRMATION REPORT PRIOR TO A FINAL INSPECTION. FYI'.c;TlNr, MFCHANICAI WAIT Wr UAWSWAN_bl DIFFUSER, GRILLE & A CC TO LOCATE GLYCOL MACHINE IN A STRUCTURALLY SOUND APPROVED AREA - COORDINATE WITH LANDLORD FRAME A TE KRUEGER 1400 GNOC TO VERIFY ALL MFG SPECS FOR ROOFTOP UNIT DURING BID PROCESS WHITE No NOTE RETURN GC TO CONSULT TENANT'S LEASE IN REGARDS TO RTUS SUPPLIED & INSTALLED MECHANICAL EQUIPMENT SCHEDULE 1� A AIR 6E&Q COOLING TOTAL NOMINAL IT ES ELECTRI 29�& - MIN. ARI HEATIN2 — 0PE`,RA`nNG HEIGHT SYMBOL MANUFACTURER MODEL # TONS ItirAL. O'S'A' IES.P. MAX FAN HP UNIT MCA VOLT / # EFFICIENCY ENT. AIR AMB' CA PA ITY H ELECTRI�__ HEAT .., WEIGHT W1 CURB MB P = EL CFM, DB I WB RDIBEN–T , TOM SM KW USOTAGLS i CARRIER (5 TON) 5 2000 400 0.8 1.0 1 kBH 600 45' RTU-1 NEW 40 208 / 1 10.0 SEER 80-0 1651 0 110 51j.743.5 an NM CARRIER OR EQUAL - GC TO VERIFY ELECTRICAL SPECS F!JRNISH- WITH THE FOLLOWING: 1. PROGRAMMABLE THERMOSTAT, ECONOMIZER 2. PROGRAMMABLE THERMOSTAT, W/GRAVITY EXHAUST & DUAL ENTHAPY W/GRAVITY EXHAUST & DW CONTROL, OUTDOOR AIR DAMPER SECTION, CONTROL, OUTDOOR AIR DAN ROOF CURB POWER ENTRY KIT, ROOF BAROMETRIC RELIEF DAMPER MOUNTING FRAME, PREFAB ROOF CURB. PRE-FAB ROOF CURB, DUAL SMOKE DETECTORS ASSOCIATED WITH SMOKE DAMPERS AND HVAC SHUTOFFS SHALL BE TESTED BY AN APPROVED TESTING AGENCY OR A QUALIFIED THIRD PARTY SPECIAL INSPECTOR. THE SPECIAL INSPECTOR/TESTING AGENCY SHALL BE AN INDEPENDENT THIRD PARTY INDIVIDUAL OR FIRM AND SHALL NOT BE THE INSTALLING CONTRACTOR. A PROFESSIONAL ENGINEER SHALL SUBMIT A FINAL SIGNED AND SEALED REPORT TO THE MECHANICAL INSPECTOR PRIOR TO CITY ISSUANCE OF FINAL INSPECTION APPROVAL OR OCCUPANCY APPROVAL, INCLUDING CONDITIONAL OCCUPANCY APPROVAL." I I MATERIALS SPECS: 1 ALL MAINLINE DUCTWORK SHALL BE NO. 1 GRADE GALVANIZED STEEL, ASTM A-120, IN ACCORDANCE WITH SMACNA STANDARDS LATEST EDITION, CURRENT UNIFORM MECHANICAL CODE, AND WITH ASHRAE GUIDE RECOMMENDATIONS. 2. FLEXIBLE DUCTS TO DIFFUSERS SHALL BE THERMAFLEX TYPE M—KE OR EQUIVALENT GLENFLEX, CLASS 0 OR CLASS 1 WITH FLAME SPREAD RATING OF 25 AND A SMOKE DEVELOPED RATING OF 50. 3. ALL AIR CONDITIONING SUPPLY AIR DUCTS SHALL BE WRAPPED WITH A MINIMUM OF 1-1/2" DUCT INSULATION MEETING NFPA —90A. INSULATION SHALL BE 3/4 PCF DENSITY WITH FOIL SCRIM KRAFT FACING. ALL AIR CONDITIONING RECTANGULAR RETURN AIR DUCTS & PLENUMS SHALL BE LINED WITH 1" THICK, 1-1/2 PCIF JOHNS—MANVILLE "LINACOUSTIC R" OR EQUAL. 4. COIL CONDENSATE DRAINS SHALL BE TYPE "M" HARD DRAWN COPPER TUBING. INSULATE CONDENSATE DRAINS INSIDE BUILDING WITH 1/2" FLEXIBLE CLOSED CELL FOAMED PLASTIC PIPE INSULATION, ARMSTRONG ARMAFLEX AP, OR EQUAL, SECURED WITH ADHESIVE. FLAME SPREAD RATING NO GREATER THAN 25 AND SMOKE DEVELOPED RATING OF 50. MECHANICAL CONTRACTOR NOTE: GENERAL C&ITRACTOR IS REQUIRED TO PERFORM A TEST AND BALANCE AND DUCT DETECTOR TEST AND PROVIDE A CONFIRMATION REPORT PRIOR TO A FINAL INSPECTION. FYI'.c;TlNr, MFCHANICAI WAIT Wr UAWSWAN_bl DIFFUSER, GRILLE & A SOU ALL SHOP DRAWINGS AND SUBMITTALS FOR APPROVAL EXPOSED OPEN DUCTWORK NECKS SHALL BE COVERED DURING CONSTRUCTION. XQIE. TEST AND BALANCE OF SYSTEMS, AND SUBMITTAL OF AIR BALANCE REPORT TO CONTRACTOR ,UOTE: STRUCTURAL ENGINEER SHALL BE CONTRACTED BY TENANT TO FURNISH LOAD CALCULATIONS AND DRAWINGS FOR GLYCOL SUPPORT AND LANDLORD APPROVAL. MECHANICAL PLAN "W WATER HEATER SEE P SHEET 0) (00 tw w z LLI o 0 < x -J 0 n n 0 w z o < (o L0 z z co r4,) V) < uj < QD 0) > ELI � — L-0 0) < J_ (r,) V_ < L/) Lb Lo Lo -r CD < zo) -4- V) z Q eC 0 < < V) 00 C) (/�w O cy) < m: < I Lt --,nion i, iji C/) REVISION FIRE COMMENTS 10-22-10 AFIRE COMMENTS 2 11-10-10 CITY COMMENTS 4-1-11 MENCHIE'S MENB549 Ij Kilt No 46-942 o S TA, T of? 11 NA L m ikki%v I m 1.1 STYLE MATERIAL FINISH O.B.D. REMARKS SYMBOL DESCRIPTION MANUF. do MODEL FRAME A SUPPLY KRUEGER 1400 LAY–IN CEILING DS�WEPN STEEL WHITE No B L RETURN KRUEGER I S80 LAY–IN CEILING FIXED BAR, WHITE NO SOU ALL SHOP DRAWINGS AND SUBMITTALS FOR APPROVAL EXPOSED OPEN DUCTWORK NECKS SHALL BE COVERED DURING CONSTRUCTION. XQIE. TEST AND BALANCE OF SYSTEMS, AND SUBMITTAL OF AIR BALANCE REPORT TO CONTRACTOR ,UOTE: STRUCTURAL ENGINEER SHALL BE CONTRACTED BY TENANT TO FURNISH LOAD CALCULATIONS AND DRAWINGS FOR GLYCOL SUPPORT AND LANDLORD APPROVAL. MECHANICAL PLAN "W WATER HEATER SEE P SHEET 0) (00 tw w z LLI o 0 < x -J 0 n n 0 w z o < (o L0 z z co r4,) V) < uj < QD 0) > ELI � — L-0 0) < J_ (r,) V_ < L/) Lb Lo Lo -r CD < zo) -4- V) z Q eC 0 < < V) 00 C) (/�w O cy) < m: < I Lt --,nion i, iji C/) REVISION FIRE COMMENTS 10-22-10 AFIRE COMMENTS 2 11-10-10 CITY COMMENTS 4-1-11 MENCHIE'S MENB549 Ij Kilt No 46-942 o S TA, T of? 11 NA L m ikki%v I m 1.1