10-920-012GENERAL NOTES 1. ALL DIMENSIONS ARE FROM FACE OF DRYWALL, UNLESS OTHERWISE NOTED. 2. ALL GYPSUM BOARD USED SHALL BE 5/8" TYPE 'X' FIRE TAPED. 3. ALL PLYWOOD, PARTICLE BOARD, WOOD BLOCKING, AND FRAMING USED SHALL BE FIRE RETARDANT & STAMPED NON - COMBUSTIBLE. 4. PLACE AND FINISH ALL NEW MATERIALS SO AS TO PROVIDE A SMOOTH & INTEGRAL TRANSITION TO EXISTING FINISHES & MATERIALS. 5. PROVIDE CUTOUTS IN TOPS AS REQUIRED TO ACCOMMODATE EQUIPMENT AS SUPPLIED BY OWNER. VERIFY SIZES AND SPECIFICATIONS WITH ACTUAL EQUIPMENT SUPPLIED ON SITE PRIOR TO CUTTING. 6. PROVIDE ADDITIONAL FRAMING /BRACING FOR ALL WALL MOUNTED EQUIPMENT. CHECK SHOP DRAWINGS OF ALL EQUIPMENT PRIOR TO INSTALLATION. 7. GENERAL CONTRACTOR TO PROVIDE REQUIRED FIRE EXTINGUISHERS) PER CODE. 8. NOT USED 9. FIRE SPRINKLERS: ADDITIONS & MODIFICATIONS AS REQUIRED BY CODE AND NFPA PAMPHLET #13. SPRINKLER HEADS CENTERED WITHIN CEILING BOARD. ANY MODIFICATIONS TO BE DONE BY LANDLORD'S SPECIFIED SPRINKLER CONTRACTOR. ALL COSTS FOR SPRINKLER RE- LOCATION TO CONFORM WITH FIT OUT DESIGN ARE ON THE TENANT. 10. SEE MECHANICAL AND ELECTRICAL SHEETS FOR ALL FIXTURE SPECIFICATIONS, WIRING, AND POWER REQUIREMENTS. 11. NEWLY INSTALLED OR RELOCATED DOORS MUST HAVE LEVER TYPE HARDWARE OR OTHER SHAPE WHICH WILL PERMIT OPERATION BY WRIST OR ARM PRESSURE AND WHICH, DOES NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING TO OPERATE, PER WAC 51.20.3103 (A) AND (C). 12. ALL DOORS TO PROVIDE 32" MIN. CLEAR OPENING WHEN OPENED TO 90 DEGREE POSITION. 13. FLOORS IN FOOD PREPARATION AREA, DISH WASHING AREA, SERVICE AREA, JANITORIAL AREA, STORAGE AREA, AND ANY AREA WHERE FOR EQUIPMENT IS PLACED SHALL BE SMOOTH, EASILY CLEANABLE, WASHABLE, DURABLE, AND OF COMMERCIAL! GRADE MATERIAL AND SHALL HAVE A MINIMUM 3/8" RADIUS INTEGRAL COVE BASE EXTENDING AT LEAST 4" UP THE WALL. GROUT SPACING FOR TILE SHALL NOT EXCEED 1/4" AND SHALL BE SEALED. 14. GC TO CONTACT NEPTUNE DESIGN FOR ADDITIONAL INFORMATION PRIOR TO BIDING CABINETS. CONTRACTOR SHOULD SUBMIT SHOP DRAWINGS FOR APPROVAL. 15. TENANT'S GC TO COMPLETE SITE VISIT AND VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS - GC TO; REVIEW TENANT'S LEASE DURING BID PROCESS TO DETERMINE RESPONSIBILITIES. 16. FLOOR SINKS SHALL BE INSTALLED FLUSH WITH THE FLOOR SURFACE AND BE LOCATED SO AS TO BE READILY ACCESSIBLE FOR CLEANING AND REPAIR. 17. WATERPROOF MEMBRANE MUST BE WATER TESTED & APPROVED BY ON -SITE OPERATING MANAGER. 18. SPRINKLER HEADS AT GYPSUM j BOARD CEILINGS MUST BE FULLY RECESSED AND COVERED WITH METAL PLATES FINISHED TO MATCH ADJACENT SURFACE. CENTER SPRINKLER HEADS IN CEILING WHERE APPLICABLE. 19. DEMISING PARTITIONS SHALL BE OF FIRECODE "X" SHEETROCK, TAPED AND SEALED TO DECK ABOVE. 20. SUPPORT WIRING FOR LAY -IN CEILING SHALL NOT BE ATTACHED TO ANY OF THE LANDLORD'S MECH, ELEC, PLUMB, OR FIRE PROTECTION PIPING EOR EQUIPMENT. 0 KEYED NOTES 1. EXISTING WALLS TO REMAIN - PATCH AND REPAIR FOR NEW FINISHES 2. METAL SHELVING RACK - 5 TIER IN HEIGHT NOT TO EXCEED 6 FEET 3. NEW FLOORSINK FOR INDIRECT DRAIN AS NEEDED 4. RESTROOM HAND SINK 5. 5' H/C TURNING CIRCLE, MIN. CLEAR DIMENSION REQUIRED 6. 3- COMPARTMENT SINK WITH (2) 18" INTEGRAL DRAIN BOARDS 7. SERVICE COUNTER - CABINET SUPPLIER TO FURNISH SHOP DRAWINGS 8. TOPPINGS COUNTER - CABINET SUPPLIER TO FURNISH SHOP DRAWINGS 9. TRASH 10. 24" JANITORIAL MOP SINK W/ WATER HEATER ABOVE 11. ELECTRIC PANELS - NEW - SEE ELECTRICAL 12. WALL - MOUNTED HAND SINK 13. EMPLOYEE LOCKERS 14. QUARRY TILE FLOORING THROUGHOUT KITCHEN 15. FIRE EXTINGUISHER 16. PROVIDE PLYWOOD BACKING FOR SHELVES ABOVE 17. COLD TOPPINGS WITH SNEEZEGUARD 18. DRY TOPPINGS 19. YOGURT MACHINES (6), WATER COOLED 20. FLOOR TRANSITION STRIP 21. HANDICAP GRAB BARS WITH BLOCKING - SEE DETAIL 2/A6 22. PREP SINK 23. F -2 FLOOR TILE - ROCA OVERALL FLOOR TILE TO BE BRICK LAID 24. HANDSINK IN COUNTER WITH SPLASHGUARD SURROUND BY CONTRACTOR 25. STACKED REFRIGERATOR /FREEZER MERCHANDISERS - FRAMED IN NICHE 26. EXISTING DOOR TO REMAIN 27. EXISTING REAR DOOR 28. NEW DRINKING FOUNTAIN WALL LEGEND: EXISTING WALL TO REMAIN. VERIFY CONDITION PATCH AND REPAIR TO LIKE NEW CONDITION 1 -HR RATED DEMISING WALL 1 LAYER 5/8" GYPSUM BOARD EACH SIDE OVER 3 5/8" NEW WALL 20 GA METAL STUDS AT 16" O.C. TO CEILING. BRACE STUDS ® 4' -0" O.C. 1 LAYER 5/8" GYPSUM BOARD EACH SIDE OVER 5 5/8" NEW WALL 20 GA METAL STUDS AT 16" O.C. TO CEILING. BRACE STUDS ® 4' -0" O.C. ROOM FINISH SCHEDULE MARK NAME FLOOR BASE WALLS CLG. CEILING REMARKS HEIGHT .14 U) z I M 0 > M U<- W w M rj SCHEDULE KEY: �_ m z I� N W w ~> M a z U FINISH ON �- ~ M g° V) V M I w J N ALL WALLS ,,, w p o z ¢ � g 0 Q • FINISH ON WALLS � � U � U ii w ¢ w c^ w SHOWN ONLY >- ° >- 00 I �? z ¢ w F- N � w d N U � N Q U Q U af O M W Z J d 00 N w Cr w I I Cr 3 U w w w M N L i N w I 101 COUNTER 101 • • -- CLG TO BE WASHABLE 102 KITCHEN • • • • -- CLG TO BE WASHABLE 103 WALK -IN COOLER • • • • -- 104 DINING ROOM 10 • • • • -- 105 RESTROOM • • • • • -- 106 STORAGE • • • • -- 107 PARTY ROOM • • • • • -- SPECS: DESCRIPTION F -1 6 "X6" QUARRY TILE - "DIABLO" TILE - SLIP RESISTANT F -2 18 "x18" ROCA TILE GROUP - PORCELAIN - AVILA COLLECTION "ALGA" (THROUGHOUT DINING /CARRIED INTO BATHROOM -BRICK LAID) B -1 6 "X6" QUARRY TILE 3/8" COVED BASE - "DIABLO" TILE B -2 6 "X18 "(CUT FROM 18 "X18 ") ROCA TILE GROUP - PORCELAIN - AVILA "ALGA" INSTALL USING SCHLUTER COVE DILEX -HK U11/011G B -3 3 "x6" CERAMIC 3/8" COVED BASE - RITTENHOUSE "ARCTICE WHITE" #A -3361 W -1 SMOOTH 5/8" GYPSUM WALLBOARD - PAINTED PER ELEVATION - SEE SHEET A4 W -2 GLASSBOARD FIBERGLASS REINFORCED PANELS (FRP) - COLOR: WHITE, INSTALL PER LOCAL HEALTH DEPT. REQUIREMENTS. W -3 3 "X6" RESTROOM WALL TILE - "FESTIVA" 3 "x6" #QF30, & RITTENHOUSE SQUARE "ARCTIC WHITE" #0790 (SEE A4) W -4 12X12 MESH - IMPERIAL /VOGUEBAY TILE - SUNFLOWER /BUBBLES TILE ORDERS CONTACTS: IMPERIAL TILE CONTACT INFO: DAL -TILE CONTACT INFO: (PLACE ORDER IMMEDIATELY CATHY SHRIGER DENISE BOWSER TO ALLOW FOR 6 WEEK P: 818.299.7789 P: 480.241.3195 / F: 602.305.8004 LEAD TIME MAX) CATHY®IMPTILE.COM DEN ISE.BOWSER®DALTILE.COM C -1 SMOOTH WASHABLE CEILING PANELS, 24" X 48" X 1/2 ", FINISH: VINYL FACE "WHITE" COMPLETED CEILING ASSEMBLY SHALL BE ONE -HOUR FIRE RATED. C -2 SMOOTH 5/8" GYPSUM WALL BOARD - PAINTED WITH SEMI -GLOSS PAINT (P -5) C -3 ARMSTRONG CEILING SYSTEM "INTERLUDE" - 9/16" PROFILED GRID W "OPTIMA" #3250 2'X2' TILES LM -1 LAMINATE - FORMICA WOODGRAIN "NATURAL CANE" #6930 -NT (NATURELLE FINISH) CT -1 COUNTER TOP - CAESAR STONE QUARTZ SURFACES "APPLE MARTINI" #2710 (1 -1/2" EDGE. BULLNOSE DETAIL) P -1 SHERWIN WILLIAMS "MENCHIE'S GREEN" (BRIGHT GREEN COLOR) CUSTOM P -2 SHERWIN WILLIAMS "MENCHIE'S LIGHT GREEN" (LIGHT GREEN COLOR) CUSTOM P -3 SHERWIN WILLIAMS "MENCHIE'S PLUM" (DEEP PLUM COLOR) P -4 SHERWIN WILLIAMS "MENCHIE'S PINK" (PEPTO PINK COLOR) CUSTOM P -5 SHERWIN WILLIAMS "EXTRA WHITE" #SW7006 (MATTE FINISH) P -6 I SHERWIN WILLIAMS "MENCHIE'S LIGHT PLUM" LIGHT PALE PLUM COLOR CUSTOM *SEE ELEVATIONS SHEET A4 FOR ADDITIONAL INFORMATION DOOR SCHEDULE NUMBER WIDTH HEIGHT TYPE THICK MAT FINISH HEAD JAMB SILL GLASS RATING REMARKS A 3' -0" 7' -0" 2 1 -3/8' SC LM -1 MTL MTL - - Provide self - closing mechanism w/ lock B 3' -0" 7' -0" 1 1 -3/8' SC LM -1 MTL MTL - - Provide self- closing mechanism E - - - - - - - - - - - Existing to Remain EXIT DOORWAYS SHALL NOT BE LESS THAN 36" IN WIDTH AND NOT LESS THAN 6' -8" IN HEIGHT PROJECTIONS, INCLUDING HARDWARE, SHALL NOT REDUCE THE OPENING TO LESS THAN 32" OF CLEAR WIDTH 1. SOLID CORE DOOR IN 2. SOLID CORE DOOR IN HOLLOW METAL FRAME Provide H/C HOLLOW METAL FRAME USE �i USE THREE HINGES, SCHLAGE AL- SERIES �� threshold THREE HINGES - FINISH PRIVACY LOCKSET, STYLE NEPTUNE OR HALLWAY SIDE WITH (LM -1) " SATURN" WITH BRUSHED CHROME FINISH - r FINISH PUBLIC SIDE WITH (LM -1) NOTE: DURING BID PROCESS - GC TO VISIT SITE & REVIEW TENANT'S LEASE TO CONFIRM RESPONSIBILITY AGREEMENT. GC RESPONSIBLE FOR ALL TI CONSTRUCTION IE. CONCRETE POUR, ELECTRIC, PLUMBING, ROOF PENETRATIONS AND MECHANICAL ETC. NQTE: CONTRACTOR TO VERIFY LOCATION AND SIZE OF EXISTING CW LINE, WATER METER AND EXISTENCE OF BACK FLOW PREVENTER. PROVIDE BID IF NEW BACKFLOW PREVENTER IS REQUIRED. NOTE: IT IS THE RESPONSIBILITY OF THE TENANT TO REVIEW THESE PROPOSED PLANS AND CONSULT WITH RESTAURANT EQUIPMENT SUPPLIER AND CONTRACTOR. CONTACT DESIGNER IMMEDIATELY IF ANY CHANGES ARE MADE. NOTE: GC TO VERIFY ALL EXISTING DIMENSIONS AND COLUMNS DURING BID AND ALERT ARCHITECT IF DIFFERENT FROM PLAN. NOTE: ONLY SINGLE SERVICE UTENSILS WILL BE USED IN THIS SPACE PROVIDE ADA RESTROOM SIGN ADJACENT TO DOOR PER CODE 1" MTL STAINLESS STEEL- CHANNEL i CUP CABINET SEE ELEVATIONS REFRIGERATED DISPLAY CASE CASED IN MILLWORK OPEN AT BACK OF MACHINE FOR VENTING - SEE 4,5,6 ON A7 MENCHIE'S CUSTOM COMMUNITY BOARD, SEE DETAIL 3/A7 PATTERN OF 18x18 FLOOR TILE TO BE BRICK LAID FINISH INTERIOR WALLS PER MENCHIE'S SPECS -SEE ELEVATIONS EM$'1ING PORTIONS .0 BUILDINGS SHALL CONIOI.LV 1 "' ITH TiIE P'RiC?MM "NS (�§' SX3S_NNQ OCCUPANCIES, AS SET FOf"°fI'I IN FIS iF�'i''AfjJ1 Ay1M,:, PR- 0T5H'r10N CODs. FLOOR PLAN SCALE: 1/4" = V -0" PROVIDE PLYWOOD BACKING BEHIND FRP FOR WALL MOUNTED SHELVES PROVIDE FULL HEIGHT FRP AT ALL WALLS IN KITCHEN (TYP) GRILL INSTALLED IN COUNTER FOR CLEANUP SEE DETAIL 9/A6 MAX HEIGHT 034" FINISH INTERIOR WALLS PER MENCHIE'S SPECS - SEE ELEVATIONS - MODULAR ARTS WAVE WALL MENCHIE'S CUSTOM CHALK BOARD, SEE 1/A7 & 2/A7 TO BE INSTALLED WITH PEGS TO RAISE CHALK BOARD OFF MODULAR ART WALL TABLES AND CHAIRS ARE NON- FIXED, TYPICAL E na ^e I p q I . 1 M � M w �4 C/1 d' REVISION 0 0 MENCHIE'S MENB549 V.:; s 9 3, yAyiz ME uJNUM R E 5.: 'NJ 4 Y.11 4 Cd O U can C to oo C" 00 zqt C .0 00 00 M .. M 00 oo O 00 A c/1 M � M w �4 C/1 d' REVISION 0 0 MENCHIE'S MENB549 V.:; s 9 3, yAyiz ME uJNUM R E 5.: 'NJ 4 Y.11 4