Loading...
11-50-015HATCH DENOTES EXISTING 1(l AREA TO REMAIN PLUMBING FIXTURE CONNECTION SCHEDULE MARK DESCRIPTION WASTE VENT C.W H.W REMARKS /SPECS WC WATER CLOSET 3" 2" 3/4" - FLOOR MOUNTED, TANK TYPE, 1.28 GPF LAV LAVATORY 1-1/2- 2" 1/2' 1/2' COUNTER TOP, 1.5 GPM DW DISHWASHER 3/4" 1 - 1/2" 1/2" 3/4" INDIRECT WASTE LINE SK SINK 2" 2" 1/2" 1/20 COUNTER TOP, 1.5 GPM R REFRIGERATOR - - 1/2" - VALVED CONNECTION 1. MAXIMUM FLOW RATES AND CONSUMPTION OF PLUMBING FIXTURES AS PER MIAMI -DADE ORDINANCE 8 -14 (CODE 8 -31). PER MIAMI DADE COUNTY AMMENDMENT TO FBC P604.4 2. FAUCETS AND FIXTURE FITTINGS WITH HOSE - CONNECTED OUTLETS SHALL CONFORM TO ASME A112.18.3M. AS PER FPC 424.4, LEGEND DESCRIPTION — _ COLD WATER LINE — — — — HOT WATER LINE —— — GATE VALVE r SANITARY LINE --- - - - - -- VENT LINE FCO FLOOR CLEAN -OUT CO I F— CLEAN -OUT CW COLD WATER HW HOT WATER V VENT POINT OF CONNECTION NOTES: 1. SCOPE OF WORK IS INTERIOR REMODELING AS SHOWN. EXISTING 3" SANITARY AND 1 "CW SERVICE TO REMAIN. VERIFY LOCATION AND SIZES. 2. PROVIDE CLEAN OUT AT ALL SANITARY BOTTOM OF STACKS. 3. WATER LINES RUN WITHIN CEILING SPACES 4. BEFORE COMMENCING WORK CONTRACTOR SHALL COORDINATE WITH ARCH. /OWNER EXACT PENETRATION OF VENTS ON ROOF. 5. PROVIDE HAMMER WATER ARRESTERS IN QUICK — CLOSING VALVE FIXTURE CONNECTIONS AS PER FPC 604.9 6. PROVIDE BRANCH VALVES AS PER FPC. 7. WORK SHALL COMPLY WITH FBC 2007 AND ADDENDUMS. SANITARY LINES SLOPE: LESS THAN 3 ": 1 /4 " /LF 3" AND GREATER: 1 /8 "/LF TPLUMBING PLAN chkplot: 01/17/2011 0 f INDEX pm�ff I • CL't" ° M�. AMP MSS, nLFOkr 5IpENCF X55 5743 5W 761` IM iw MWA MA oftoll "�� �r. c I o J, VITul F�# 59a�9 r t..3 ii T Z °' _j CO w U_ co `o LO M Z •� o .. X R cz w w �i Lu Z_ p c '2 Z c � C) L9 @J o 0° �, rn Z .-. o > a co CO o m h U oftoll "�� �r. c I o J, VITul F�# 59a�9