11-50-0091r -10" 1 4` (3.000 P.S.I.) CONC. SLAB W/ 6X6 -10/10 W.W.M. OR FIBER MESH ON 6 MIL. VAPOR BARRIER LAPPED V AND TAPED OVER CLEAN 95% COMPACTED TERMITE TREATED SCALE 3/16 " -1' -0' I I SEE POTTING ATE. DL AIL - kINVEE FOTTIN ATT. DETAIL 1- J5 VERT. & DOWEL FROM FTC. TO -ND BEAM 1 f I ( I 1 IN POURED CEL W% 25` OVERLAP -0 fff IL_ (TYP.) MAX. SPACING O B' -0" t " FOUNDATION PLAN 17-10r SCALE 3/16" ®1' -O` SLAB ON GRADE TO BE 4" THICK WITH 6 x 6 - W1.4 x WI.4 W.W.F. ON VAPOR BARRIER OVER COMPACTED TERMITE TREATED SOIL. TOP OF SLAB ELEVATION = 0' -0" EXSITING. PROVIDE 12' MIN. SOIL COVER OVER ALL EXTERIOR FOUNDATIONS. CONTRACTOR TO FIELD VERIFY FOUNDATION ELEVATIONS AND NOTIFY ARCHITECT/ ENGINEER OF ANY DISCREPANCIES. REFER TO ARCHITECTURAL/ CIVIL FOR EXTERIOR SLAB AND SIDEWALK INFORMATION. INSTALL MASONRY CONTROL JOINTS AT 32' -0" O.C. MAXIMUM. REFER TO MASONRY CONTROL JOINT DETAIL 1 /Stb. COORDINATE LOCATIONS WITH ARCHITECTURAL REQUIREMENTS. CONTRACTOR TO COORDINATE TOP / BOTTOM OF FOUNDATION ELEVATIONS WITH EXISTING SITE CONDITIONS AND STEP FOOTINGS AS REQUIRED TO MAINTAIN PROPER COVERAGES - SEE DETAIL SEE SHEET DETAIL FOR WIND TABLES. THE SAFE ALLOWABLE SOIL BEARING CAPACITY FOR PURPOSE OF DESIGN IS ASSUMED TO BE 2000 P.S.F. All Soil or Waste pipe or building drains under a footing or through a foundation wall Shall have a pipe TWO (2) sizes greater than the pipe passing though as per plumbing code. 10. CONTRACTOR TO VERIFY ALL DIMENSIONS AND MATERIAL SELECTIONS PRIOR TO CONST. �0 y CONCRETE SLAB - — varies— —4 SUBCATEGORY MANUFACTURE APPROVAL. No. STAIRS DETAIL FILL WITH DIRT Swinging Exterior Door Assemblies PGT INDUSTRIES FL 11296 U SHUTTERS c) TRANSPARENT PROTECTION SYSTEM, INC. W JANUARY 24 2012 CONCRETE SLABI ® Gaf Materials Corp. i JANUARY 27 2010 STRUCTURAL COMPONENTS Product In as o New Technology FECP CORP. CAST CRETE DIV. FL 158 -R3 DECEMBER 31 2099 TRUSS PLATE tj FL 1999 -R3 > WOOD CONNECTORS ANCHORS SIMPSON STRONG -TIE CO. FL 10852/11470 DECEMBER 31 2099 GARAGE DOOR zl Wayne Dalton Corp. z WINDOWS U 1 CONCRETE SLAB I U FL243RB - — varies— —4 SUBCATEGORY MANUFACTURE APPROVAL. No. STAIRS DETAIL 31" LONG MIN #5 BAR EPDXIED INTO CONC. v #5 BAR W/ 25" MIN. LAP SPLICE. • HOLE HARDENED it iY k -SET- EPDXY r ii k ii ei i • . . RETROFIT DETAIL C3id FOOTING ATTACHMENT DETAIL EXTERIOR BLOCK WALL ATACHMENT TO BLOCK WALL N.T.S. FLOOR JOIST AREA 1" T.G. PLYWOOD GLUED I & NAILED 2X6' P.T. GLUED & NAILED I 2X12' P.T. GLUED & NAILED 1/4`X4` TAPCON O 12" 1/4'X4' TAPCON O 12" O.0 E 7A2X6* P. T. GLUED & NAILED EXIST. 4" CONC. SLAB FLOOR JOIST DETAIL I ILYOUT I I I TERMITE SPECIFICATIONS 1. A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER AND NEED FOR RE- INSPECTION AND TREATMENT OF CONTRACT RENEWAL SHALL BE PROVIDED. THE SIGN SHALL BE POSTED NEW THE WATER HEATER OR ELECTRIC PANEL. (F9C 1042.6) 2. CONDENSATE AND ROOF DOWN SPOUTS SHALL DISCHARGE AT LEAST V -O" AWAY FROM BUILDING SIDEWALKS. (FBC 1503.4.4) 3. IRRIGATION / SPRINKLER SYSTEMS INCLUDING ALL RISERS AND SPRAY HEADS SHALL NOT BE INSTALLED WITHIN 1' -O" OF THE BUILDING SIDE WALLS. (FBC 1503.4.4) 4. TO PROVIDE FOR INSPECTION FOR TERMITE INFESTATION. BETWEEN WALL COVERING AND FINAL EARTH GRADE SHALL NOT BE LESS THAN 6 INCHES. EXCEPTION: PAINT OR DECORATIVE CEMENTATIOUS FINISH LESS THAN 5/8' THICK ADHERED DIRECTLY TO THE FOUNDATION WALL.. (FBC 14011.6) 5. INITIAL TREATMENT SHALL BE DONE AFTER ALL EXCAVATION AND BACK FILL IS COMPLETE. (FBC 1816.1.1) 6. Sal DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RETREATED INCLUDING SPACES BOXED AND FORMED. (FBC 1816.1.2) 7. BOXED AREAS IN CONCRETE FLOORS FOR SUBSEQUENT INSTALLATION OF TRAPS, ETC., SHALL BE MADE WITH PERMANENT METAL OR PLASTIC FORMS. PERMANENT FORMS MUST BE OF A SIZE AND DEPTH THAT WILL ELIMINATE THE DISTURBANCE OF SOIL AFTER THE INITIAL. TREATMENT. (FBC 1816.1.3) 8. MINIMUM 6 MIL VAPOR RETARDER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL DILUTION. IF RAINFALL OCCURS BEFORE VAPOR RETARDER PLACEMENT, RETREATMENT IS REQUIRED. (FBC 1816.1.4) 9. CONCRETE OVERPOUR AND MORTAR ALONG THE FOUNDATION PERIMETER MUST BE REMOVED BEFORE EXTERIOR SOIL TREATMENT. (FBC 1816.1.5) NEW WALL SECTION N.T.S. DPE FIAT I N.I.O. FOR REFERENCE ONLY - TRUSSES MUST BE PREENGINERING BY MANUFACTURE Note: Condense and roof down spouts shall discharge at least 1' -0" Away from building side walls PRODUCT APPROVAL. PRODUCT CATEGORY SUBCATEGORY MANUFACTURE APPROVAL. No. EXP. DATE EXTERIOR DOORS Swinging Exterior Door Assemblies PGT INDUSTRIES FL 11296 APRIL 24 2012 SHUTTERS STORM PANELS TRANSPARENT PROTECTION SYSTEM, INC. FL 6416 -R1 JANUARY 24 2012 ROOFING Gaf Materials Corp. FL183 JANUARY 27 2010 STRUCTURAL COMPONENTS Product In as o New Technology FECP CORP. CAST CRETE DIV. FL 158 -R3 DECEMBER 31 2099 TRUSS PLATE ALPINE ENGINEERING PROD. INC FL 1999 -R3 DECEMBER 31 2099 WOOD CONNECTORS ANCHORS SIMPSON STRONG -TIE CO. FL 10852/11470 DECEMBER 31 2099 GARAGE DOOR Exterior Overhead Wayne Dalton Corp. FL5587 WINDOWS Fixed PGT Industries FL243RB Double Hung PGT Industries FL7058 -R3 ^� Sliders PGT Industries FL242-RlO PANEL WALLS Soffits Alsco Metals Corp. FL1778 NOTES: 1. ALL PRODUCTS APPROVAL INFORMATION WAS OBTAINED FROM FLORIDA BUILDING CODE WEBSIDE. 2. ALL PRODUCT APPROVALS LISTED ABOVE HAVE STATEWIDE APPROVAL. CONTRACTOR MUST PROVIDE PRODUCT APPROVAL PRIOR TO INSTALATION. NEW EXTERIOR REINFORCED CONCRETE BLOCK WALL O EXIST. WALL N.T.S. 1" X 4" PT NAILER (EXITS` TING) BLOCK �` X 8" 16` CONC. BLOCK ,EXISTING 1" PT FURRING STRIP Q 24" O.C. R -5 INSULATION I/2" DRYWALL FOOTER TO 4"x " INSI AT E ACH F 0' -0` F.F. ELEV. NEW EXTERIOR REINFORCED CONCRETE BLOCK WALL O EXIST. WALL THROUGH WINDOW N.T.S. r ♦ , i MUM COW. IMM aull C ae atel ier Corp.) Z 0 m �.# t- 0 r+w 7 wi�w a` Z q Z arw P U p O L 0 =NCI r mnn f ^� rc vino Z ®Ire n r- vrw Zw_o1 Z; o W i D It *+� ZP W 0n Z r: } ! 0 > I Z a W I .s w� J } U ,� 9251 CA Vr&-rd Cf rH: 5619292154 r 4 /. AZrs � JfV �b�GON71�l,�Z s ai FL.keq. LVence # 66116 ffil R81