10-1088-033SYMBOLS SYMBOLS, THIS IS A MASTER LEGEND AND NOT ALL ON THE DRAWINGS, PIPING NOTE: ALL DUCT DIMENSIONS SHOWN ON DRAWINGS ARE INSIDE DIMENSIONS. CD CONDENSATE DRAIN (CD) ACD AUXILIARY CONDENSATE DRAIN (ACD) RL REFRIGERANT LIQUID (RL) RD REFRIGERANT DISCHARGE (HOT GAS) (RD) RS REFRIGERANT SUCTION (RS) HWS HEATING HOT WATER SUPPLY (HWS) — —HWR -- HEATING HOT WATER RETURN (HWR) CWS CHILLED WATER SUPPLY (CWS) — —CWR— CHILLED WATER RETURN (CWR) HS HEAT PUMP SUPPLY (HS) ---HR--- HEAT PUMP RETURN (HR) UPS LOW PRESSURE STEAM SUPPLY (UPS) —LPC — — LOW PRESSURE STEAM CONDENSATE (LPC) — — — — — EXISTING PIPING TO BE REMOVED TYR EXISTING PIPING TO REMAIN MANUAL VOLUME DAMPER DIRECTION OF FLOW ow .c BALL VALVE RD (SD= SUPPLYpRD= RETURN) CONTROLVALVE FSD FIRE SMOKE DAMPER HS HUMIDITY SENSOR SD SMOKE DAMPER PS PULL STATION THREE -WAY CONTROL VALVE MD MOTORIZED DAMPER TS TEMPERATURE SENSOR SHUTOFF VALVE DAMPER FI HUMIDISTAT CHECK VALVE t3fJ BALANCING VALVE: WITH PRESSURE PORTS ANNOTATION TRIPLE DUTY VALVE WITH PRESSURE PORTS f WATER METER CU MECHANICAL EQUIPMENT DESIGNATION (CONTRACTOR STRAINER —F�F -- D�f SOLENOID VALVE P PRESSURE GAUGE 1 SECTION CUT DESIGNATION M1 THERMOMETER I PRESSURE AND TEMPERATURE TEST PLUG UNION FLANGE CONNECTION - -+C? ELBOW UP a ELBOW DOWN 24 "x24" TEE UP TEE DOWN REDUCER HVAC EQUIPMENT & DUCTWORK NOTE: ALL DUCT DIMENSIONS SHOWN ON DRAWINGS ARE INSIDE DIMENSIONS. SEE SECTION 15250 OF THE SPECIFICATION FOR DUCTWORK TO RECEIVE INSULATION OR LINER. BAS BUILDING AUTOMATION SYSTEM EXISTING DUCTWORK OR EQUIPMENT TO REMAIN MINIMUM EXISTING DUCTWORKOR EQUIPMENT TO BE REMOVED NO BRANCH DUCT WITH 45® RECTANGLE -ROUND BRANCH CFM CUBIC FEET PER MINUTE FITTING AND MANUAL VOLUME DAMPER ee`e ELBOW WITH TURNING VANES RA RETURN, EXHAUST, OR OUTSIDE AIR DUCT UP tea I i `e RETURN, EXHAUST, OR OUTSIDE AIR DUCT DOWN SUPPLYAIR SUPPLY AIR DUCT UP SO SUPPLY AIR DUCT DOWN FFA FROM FLOOR ABOVE EQUIPMENT WITH FLEXIBLE DUCT CONNECTION TO FLOOR ABOVE 10m CSD -1 300 CFM TFB TO FLOOR BELOW NECK SIZE, TYPE, CFM OF SUPPLY DIFFUSER OR REGISTER TYR TYPICAL MANUAL VOLUME DAMPER LIND SQUARE TO ROUND TRANSITION MAX MAXIMUM DUCT MOUNTED SMOKE DETECTOR RD (SD= SUPPLYpRD= RETURN) PD FIRE DAMPER CARBON DIOXIDE SENSOR FSD FIRE SMOKE DAMPER HS HUMIDITY SENSOR SD SMOKE DAMPER PS PULL STATION \tp VOLUME DAMPER SP STATIC PRESSURE SENSOR MD MOTORIZED DAMPER TS TEMPERATURE SENSOR g3 BACKDRAFT DAMPER FI HUMIDISTAT 48" Lal THERMOSTAT ABBREVIATIONS TITUS AFF ABOVE FINISHED FLOOR PAC MECHANICAL CONTRACTOR BAS BUILDING AUTOMATION SYSTEM MIN MINIMUM BD BACKDRAFT DAMPER NO NOISE CRITERIA CFM CUBIC FEET PER MINUTE OA OUTSIDE AIR ODC DIRECT DIGITAL CONTROL RA RETURN AIR DX DIRECT EXPANSION SA SUPPLYAIR EA EXHAUST AIR SO SMOKE DUCT DETECTOR FFA FROM FLOOR ABOVE TEA TO FLOOR ABOVE FFB FROM FLOOR BELOW TFB TO FLOOR BELOW GPM GALLONS PER MINUTE TYR TYPICAL IN WC INCHES OF WATER COLUMN LIND UNLESS NOTED OTHERWISE MAX MAXIMUM W/ WITH MBH 1 OW BTU PER HOUR W/O WITHOUT STANDARD MOUNTING HEIGHTS MECHANICAL (AFF, AFG, UNLESS NOTED OTHERWISE) THERMOSTATS (USER ADJUSTABLE)(TOP OF DEVICE) 48" CONTROLS (TOP OF DEVICE) 48" ANNOTATION 0 MECHANICAL PLAN CALLOUT CU MECHANICAL EQUIPMENT DESIGNATION (CONTRACTOR FURNISHED AND 1 INSTALLED UNLESS NOTED OTHERWISE) ROB CONNECTION POINT OF NEW WORK TO EXISTING 1 DETAIL REFERENCE UPPER NUMBER INDICATES DETAIL NUMBER LOWER M1 NUMBER INDICATES SHEET NUMBER 1 SECTION CUT DESIGNATION M1 i ROOF NOTE: DO NOT ATTACH ANYTHING DIRECTLY TO THE UNDERSIDE OF DECK. VERIFY ALL CONDITIONS FIELD ,IN THE PRIOR BIDDING. REQUIREMENTS .. #. TO COMMENCING ANY f INFORMATION ON # THE EXISTING MECHANICAL SYSTEMS IS BASED ON #•# DRAWINGS AVAILABLE AT THE TIME OF DESIGN. FIELD VERIFY ALL EXISTING CONDITIONS A# NOTIFY ARCHITECT AND ENGINEER IMMEDIATELY IF ANY DISCREPANCIES . • FOUND. HVAC DESIGN TITUS REQUIRES YES NO DUCT SMOKE DETECTOR* YES FIRE DAMPERS - 22 -1 12W HORIZONTAL SDA 272RS -1 14 ®x10" 10"x6° Q NO 0 - 0 SMOKE CONTROL DEFLECTION 126AG -35 SD-2 TITUS TMR 14 "o 8 "0 0 0 ROB 8 "o NECK SD-3 TITUS PAS 24 "x24" 8 "0 0 0 B 8 "o NECK TITUS INSTALL BLADES FACING THE TGA 355RL 12 "x12" 8 "x8" 0 0 CEILING 8x8 TITUS INSTALL BLADES FACING THE RGA 355RL 28 "x14" 24 "x10" 0 0 CEILING 2410 TITUS RG -2 PAR 12 "x12" 8 "x8" 0 0 8x8 ROOF NOTE: DO NOT ATTACH ANYTHING DIRECTLY TO THE UNDERSIDE OF DECK. VERIFY ALL CONDITIONS FIELD ,IN THE PRIOR BIDDING. REQUIREMENTS .. #. TO COMMENCING ANY f INFORMATION ON # THE EXISTING MECHANICAL SYSTEMS IS BASED ON #•# DRAWINGS AVAILABLE AT THE TIME OF DESIGN. FIELD VERIFY ALL EXISTING CONDITIONS A# NOTIFY ARCHITECT AND ENGINEER IMMEDIATELY IF ANY DISCREPANCIES . • FOUND. HVAC DESIGN REQUIRES YES NO DUCT SMOKE DETECTOR* YES FIRE DAMPERS - NO SMOKE DAMPERS NO FIRE RATED ENCLOSURE CEILING ASSEMBLY NO FIRE STOPPING - NO SMOKE CONTROL - NO N