Loading...
09-1112-042KIT NOTES: 'I -- A.>.= AMERICAN STANDARD 2--- ALL EXPOSED TRIM, SUCH AS P— TRAPS, ANGLE STOPS, AND SUPPLIES SHALL BE CHROME PLATED. 3---- ALL FIXTURE SHALL BE COMPLY WITH REFERENCES STANDARDS AS PER FBC 2007 PLUMBING 406 THRU 424 4— ALL FIXTURE TO COMPLY WITH FBC TABLE 604.3 AND TABLE 604.4 CONNECT 2 "VT PIPE TO EXISTING VENT LINE . > `. ' EWC 2 AD I ' I LAV— H EWC " 4,9 DD 1 ), WC — H I ,, CO et Vn DD /G 112 D> 2 I 3 "F D " Col _ /ADD LAV —H W(__1' --H I s I WC - -H 2 I a, 72,FU� I7 DD I yD . AAV. 3/4„ )/2„ I - ' n ADD 1 G la Y2 JJIy EWC LAV —H DD 3, CO Y2 y2, n , ,. 3 "I'D y4 I EWC CO /Y ¢� 2 3 "(22FU) t 1 /2" RESEAL 3/4" CW PIPE UP. CONNECT LINE FROM TRAP TO EXISTING CW LINE. ,. 2(2FU) E;fp PRIMER. (TYP) 'Co a CONNECT SAN. TO EXISTING :.SANITARY LINE. : - - - Wit- I ... ..: — WATER 1 SANITAR RI _ DIAGRAM NTS WATER RISER DIAGRAM - NTS i TYPICAL CONDENSATE DRAIN TRAP CONNECT 'TO EXISTING PIPE. VERIFY EXACT SIZE, LOCATION, INVERT & CAPACITY IN FIELD PRIOR TO COMMENCEMENT OF WORK. NOTIFY ARCHITECT & ENGINEER OF ANY DISCREPANCIES. l CONNECT TO EXISTING PIPE. VERIFY EXACT SIZE, LOCATION, INVERT & CAPACITY IN FIELD PRIOR TO COMMENCEMENT OF WORK. NOTIFY ARCHITECT & ENGINEER OF ANY DISCREPANCIES. TYPICAL CLEANOUT DETAIL FASTENERS :OyC. SLAB TOP /BOTTOM BEAM FACE ❑F WALL CLAMP W/ LOCK NUT STEEL I BEAM a a ° 4 OR BAR JOIST <: 4 4 ALL THREADED l_ ' HANGER ROD STAINLESS STEEL COVER CENTER I BEAM_____ -, DROP IN ANCHOR SCREWED TO THREADED LOAD CLAMP ALL THREADED C.O. PLUG, HANGER ROD ALL THREADED POWDER DRIVEN STUDS MAY BE HANGER ROD USED IN LIEU OF LISTED CONCRETE INSERTS WHERE APPROVED BY STRUCTURAL ENGINEER N.T.S ALL FASTENERS SHALL BE LISTED FOR THEIR INTENDED SERVICE PIPE HANGERS WALL ALL THREADED ALL THREADED HANGER ROD HANGER ROD REINFORCED CONCRETE IN TRAFFIC AREAS, COVER (REMOVABLE) SCHED: 40 PVC IN NON (TRAFFIC GRADE WHERE REQUIRED) TRAFFIC AREAS � FINISHED. FLOOR 12" MIN. CONDENSATE DRAIN PIPE 24" MIN. SEAL WITH EXPANDING GROUT AROUND PIPE ' COARSE GRAVEL r i DRYWELL DETAIL NO SCALE cD\as s f fl. 0 UL `rl's t eR` CAJ 2074 2 Hour Fire Rated Through Penetration Firestop for Plastic Pipe through 3735 Green Rd. Concrete Floors or Walls using Beachwood, OH, 44122 TREMstop WS and TREMstop MCR. F- Rating = 2 Hour Drawing not to scale T— Rating = 1 -1/2 Hour (2 -WAV 1Q Pre —Rated Concrete Floors or Block Walls = Min. 4 -1/2" thickness (2 Plastic Pipe — 2" diam. (or smaller) Sch. 40 PVC pipe for use in closed or open piping systems. A nom. annular space of 1/8" is required within the firestop system. O TREMstop WS — Intumescent wrap strips, continuously wrapped around outer circumference of the pipe four times. ® TREMstop MCR — Prefabricated steel collar wrapped over the wrap strips (Item 3) and mechanically fastened to the floor or wall assembly. (5 FYRE —SIL — Min. 1/4" bead of sealant applied at the interface of the concrete slab and steel collar, and at the interface of the steel collar and pipe. An additional 1/4" thick bead of caulk to be applied around the the pipe at the interface with the top of the concrete slab. NOTE: In floors, apply below the concrete slab. In walls, apply to each side of assembly. Project: The Tremco products used above have been The above described assembly has been tested in accordance with the following: y ASTM E814 UL1479 Standard Test Method tested and is based on both past and antici- Location: for Through Penetration Fuestopping. pated performance criteria. Tremco shall not be liable for any damages, direct or con — Installer: sequential, resulting from use of this material Date: 3/05/97 1 Drawing: TR -2074 or design. Tremco shall only be responsible Signature: JApproved by: J. Pitcole for replacing material found to be defective. NUT NUT ALL HANGER RODS, HANGERS, FASTENERS, ETC. SHALL BEi CLEVIS HANGER ADJUSTABLE SWIVEL PROVIDED WITH FACTORY APPLIED PIPE O.D. LOOP HANGER ZINC PLATING PIPE PIPE — ALL HANGLKS SHALL HL LISTED N.T.S. FOR THEIR INTENDED SERVICE SI U ®L S step` WL 2129 Vii" DRAIN IMM, UN 1/2" PIPE FROM DRAIN IPE OUTLET TO NEAREST OLD WATER LINE. PROVIDE RAP PRIMER ONLY WHERE EQUIRED BY CODE, OORDINATE WITH THE KCAL PLUMBING INSPECTOR 1 or 2 Hour Fire Rated Through Penetration Firestop for Single MOH00® Plastic Pipe through 3735 Green Rd. Gypsum Walls using Beachwood, OH, 44122 TREMstop IV F-- Rating = 1 and 2 Hr. Drawing not to scale — T Rating 2 Hr. r9 BLITSTEIN DESIGN ASSOCIATES'' Architecture Interior Design 285 Sevilla Avenue Coral Gables, FI 33134 (305) 444 -4433 PLUMBING i RE CONNECTION SCHEDULE N0. DESCRIPTION WASTE VENT WATER REMARKS COLD HOT WC- -H WATER CLOSET HANDICAP 3" 2" 1/2" -- —AS=CTED BY OWNER. FLUSH VALVE TYPE TANK, 1.28 GPF, FLOOR MOUNTED. WHEEL CHAIR HEIGHT LAV -H LAVATORY HANDICAP 1 1/2" 1 1/2" 1/2" -- AS SELECTED BY OWNER. PROVIDE 0.5 GPM FAUCET PROVIDE CONCEAL ARM CARRIER AND INSULATI( EWC ELECTRIC WATER COOLER 1 1/4" 1 1/2" 1/2" - -- AS SELECTED BY OWNER. Continental "t "�� t Fidelity The annular space shall Corporation to max. 1 -3/8" within the firestop system. NOTES DETAILS �ufis� TREMstop IA — Min. 1/2" thickness of sealant applied within opening. Additional sealant All KIT NOTES: 'I -- A.>.= AMERICAN STANDARD 2--- ALL EXPOSED TRIM, SUCH AS P— TRAPS, ANGLE STOPS, AND SUPPLIES SHALL BE CHROME PLATED. 3---- ALL FIXTURE SHALL BE COMPLY WITH REFERENCES STANDARDS AS PER FBC 2007 PLUMBING 406 THRU 424 4— ALL FIXTURE TO COMPLY WITH FBC TABLE 604.3 AND TABLE 604.4 CONNECT 2 "VT PIPE TO EXISTING VENT LINE . > `. ' EWC 2 AD I ' I LAV— H EWC " 4,9 DD 1 ), WC — H I ,, CO et Vn DD /G 112 D> 2 I 3 "F D " Col _ /ADD LAV —H W(__1' --H I s I WC - -H 2 I a, 72,FU� I7 DD I yD . AAV. 3/4„ )/2„ I - ' n ADD 1 G la Y2 JJIy EWC LAV —H DD 3, CO Y2 y2, n , ,. 3 "I'D y4 I EWC CO /Y ¢� 2 3 "(22FU) t 1 /2" RESEAL 3/4" CW PIPE UP. CONNECT LINE FROM TRAP TO EXISTING CW LINE. ,. 2(2FU) E;fp PRIMER. (TYP) 'Co a CONNECT SAN. TO EXISTING :.SANITARY LINE. : - - - Wit- I ... ..: — WATER 1 SANITAR RI _ DIAGRAM NTS WATER RISER DIAGRAM - NTS i TYPICAL CONDENSATE DRAIN TRAP CONNECT 'TO EXISTING PIPE. VERIFY EXACT SIZE, LOCATION, INVERT & CAPACITY IN FIELD PRIOR TO COMMENCEMENT OF WORK. NOTIFY ARCHITECT & ENGINEER OF ANY DISCREPANCIES. l CONNECT TO EXISTING PIPE. VERIFY EXACT SIZE, LOCATION, INVERT & CAPACITY IN FIELD PRIOR TO COMMENCEMENT OF WORK. NOTIFY ARCHITECT & ENGINEER OF ANY DISCREPANCIES. TYPICAL CLEANOUT DETAIL FASTENERS :OyC. SLAB TOP /BOTTOM BEAM FACE ❑F WALL CLAMP W/ LOCK NUT STEEL I BEAM a a ° 4 OR BAR JOIST <: 4 4 ALL THREADED l_ ' HANGER ROD STAINLESS STEEL COVER CENTER I BEAM_____ -, DROP IN ANCHOR SCREWED TO THREADED LOAD CLAMP ALL THREADED C.O. PLUG, HANGER ROD ALL THREADED POWDER DRIVEN STUDS MAY BE HANGER ROD USED IN LIEU OF LISTED CONCRETE INSERTS WHERE APPROVED BY STRUCTURAL ENGINEER N.T.S ALL FASTENERS SHALL BE LISTED FOR THEIR INTENDED SERVICE PIPE HANGERS WALL ALL THREADED ALL THREADED HANGER ROD HANGER ROD REINFORCED CONCRETE IN TRAFFIC AREAS, COVER (REMOVABLE) SCHED: 40 PVC IN NON (TRAFFIC GRADE WHERE REQUIRED) TRAFFIC AREAS � FINISHED. FLOOR 12" MIN. CONDENSATE DRAIN PIPE 24" MIN. SEAL WITH EXPANDING GROUT AROUND PIPE ' COARSE GRAVEL r i DRYWELL DETAIL NO SCALE cD\as s f fl. 0 UL `rl's t eR` CAJ 2074 2 Hour Fire Rated Through Penetration Firestop for Plastic Pipe through 3735 Green Rd. Concrete Floors or Walls using Beachwood, OH, 44122 TREMstop WS and TREMstop MCR. F- Rating = 2 Hour Drawing not to scale T— Rating = 1 -1/2 Hour (2 -WAV 1Q Pre —Rated Concrete Floors or Block Walls = Min. 4 -1/2" thickness (2 Plastic Pipe — 2" diam. (or smaller) Sch. 40 PVC pipe for use in closed or open piping systems. A nom. annular space of 1/8" is required within the firestop system. O TREMstop WS — Intumescent wrap strips, continuously wrapped around outer circumference of the pipe four times. ® TREMstop MCR — Prefabricated steel collar wrapped over the wrap strips (Item 3) and mechanically fastened to the floor or wall assembly. (5 FYRE —SIL — Min. 1/4" bead of sealant applied at the interface of the concrete slab and steel collar, and at the interface of the steel collar and pipe. An additional 1/4" thick bead of caulk to be applied around the the pipe at the interface with the top of the concrete slab. NOTE: In floors, apply below the concrete slab. In walls, apply to each side of assembly. Project: The Tremco products used above have been The above described assembly has been tested in accordance with the following: y ASTM E814 UL1479 Standard Test Method tested and is based on both past and antici- Location: for Through Penetration Fuestopping. pated performance criteria. Tremco shall not be liable for any damages, direct or con — Installer: sequential, resulting from use of this material Date: 3/05/97 1 Drawing: TR -2074 or design. Tremco shall only be responsible Signature: JApproved by: J. Pitcole for replacing material found to be defective. NUT NUT ALL HANGER RODS, HANGERS, FASTENERS, ETC. SHALL BEi CLEVIS HANGER ADJUSTABLE SWIVEL PROVIDED WITH FACTORY APPLIED PIPE O.D. LOOP HANGER ZINC PLATING PIPE PIPE — ALL HANGLKS SHALL HL LISTED N.T.S. FOR THEIR INTENDED SERVICE SI U ®L S step` WL 2129 Vii" DRAIN IMM, UN 1/2" PIPE FROM DRAIN IPE OUTLET TO NEAREST OLD WATER LINE. PROVIDE RAP PRIMER ONLY WHERE EQUIRED BY CODE, OORDINATE WITH THE KCAL PLUMBING INSPECTOR 1 or 2 Hour Fire Rated Through Penetration Firestop for Single MOH00® Plastic Pipe through 3735 Green Rd. Gypsum Walls using Beachwood, OH, 44122 TREMstop IV F-- Rating = 1 and 2 Hr. Drawing not to scale — T Rating 2 Hr. r9 BLITSTEIN DESIGN ASSOCIATES'' Architecture Interior Design 285 Sevilla Avenue Coral Gables, FI 33134 (305) 444 -4433 project number date 12/07/09 revision drawn by A.R, F.G, J.L, G.R °;. 1@ Pre —Rated Gypsum Wallboard /Stud Wall Assembly project name sheet title Existing Building Plastic. Pipe — Nom 2" diam. (or Renovation for A t V Continental "t "�� t Fidelity The annular space shall Corporation to max. 1 -3/8" within the firestop system. NOTES DETAILS �ufis� TREMstop IA — Min. 1/2" thickness of sealant applied within opening. Additional sealant All 5734 Sunset Drive that a min. South Miami, Florida K project number date 12/07/09 revision drawn by A.R, F.G, J.L, G.R °;. 1@ Pre —Rated Gypsum Wallboard /Stud Wall Assembly sheet title Plastic. Pipe — Nom 2" diam. (or smaller) CPVC pipe for use in closed piping systems. PLUMBING' The annular space shall be min. 1/4" to max. 1 -3/8" within the firestop system. NOTES DETAILS 3� TREMstop IA — Min. 1/2" thickness of sealant applied within opening. Additional sealant All to be installed such that a min. 1/4" crown is formed around the K penetrating item. <I SCALE: 1/4" _ `1' -0" PROJECT N0: 0911 -093 p f ° "� Jr 4247 SW 71st AVENUE sheet number, ,•`�, q. Mian i, Florida 33155 i Tel: (305) 661 -0800 Fax: (305) 661 -0811 a 91f, Email: uci @ucieng.com ., ..a r R.J. Miranda P.E. No. 35579 ° David A. Belsky P.E. No. 37234 EB0004041 i Z uciengineering �: Professional Electrical and ` From V i s i o n to R e a l i t y : Mechanical Engineers