09-1112-032GENERAL MECHANICAL CITES 1 -- SCOPE OF WORK WORK SHALL INCLUDE ALL LABOR, EQUIPMENT AND PERFORMING ALL OPERATIONS IN CONNECTION WITH THE FURNISHING OF ALL AIR CONDITIONING, HEATING AND VENTILATION WORK AS SHOWN ON DRAWINGS. HEREIN SPECIFIED AND /OR EQUAL EQUIPMENT FOR APPROVAL. 2- AIR CONDITIONING SYSTEM OF SPLIT TYPE, SHALL CONSIST OF CONDENSING UNIT AND AIR HANDLING UNIT AS INDICATED ON DRAWINGS. SYSTEM SHALL BE PROVIDED COMPLETE WITH FRAMES AND ENCLOSURES, WIRING, NECESSARY CONTROLS REFRIGERANT CHARGE AND OIL CHARGE, STRIP HEATER, INTERCONNECTING PIPES AND FILTER BOX. REFRIGERANT LINES SHALL BE OF COPPER OF THE PRECHARGED, PRE - INSULATED TYPE FURNISHED AND SIZED BY SUPPLIER OF EQUIPMENT. PROVIDE SMOKE DETECTORS TO SHUT OFF UNIT. 3- CONDENSATE WATER PIPING. CONDENSATE PIPING SHALL BE OF PVC SCHED. 40, EXCEPT INSIDE A/C PLENUM SPACES WHERE COPPER PIPING SHALL BE INSTALLED. 4- OUTSIDE AIR INTAKE SHALL BE AT 10' MINIMUM DISTANCE FROM ANY EXHAUST VENT. 5- DUCTWORK PROVIDE VOLUME DAMPERS, TURNING VANES, ETC., IN DUCTWORK FOR PROPER AIR FLOW AND BALANCE. PROVIDE VOLUME DAMPER WITH LOCKING QUADRANT AT ALL FLEXIBLE DUCT CONNECTIONS WITH SUPPLY DUCTWORK. PROVIDE MULTIPLE VANE EXTRACTORS WITH CONTROL RODS ACCESSIBLE FROM THE REGISTER AT ALL OUTLETS CONNECTED CLOSER THAN TWO DUCT DIAMETERS TO MAIN SUPPLY DUCT, AND WHERE SHOWN ON DRAWINGS. FLEXIBLE DUCTS SHALL BE THE INSULATED TYPE, SUPPORTED AND INSTALLED TO AVOID SAGS AND KINKS. ALL FLEXIBLE DUCTS SHALL BE SIMILAR IN LENGTH TO AVOID DISSIMILAR PRESSURE DROPS. FLEXIBLE DUCTS SHALL BE CONSTRUCTED AND INSTALLED IN ACCORDANCE WITH SMACNA'S HVAC DUCT CONSTRUCTION STANDARDS. SEAL ALL FLEXIBLE DUCTS TO SUPPLY DUCTS AND DIFFUSERS WITH DUCT TAPE AND MASTIC. EXCEPT AS SPECIFIED OTHERWISE, NEW AIR CONDITIONING SUPPLY, AND AIR DUCTWORK SHALL BE CLASS 1 GLASS FIBER DUCT BOARD CONSTRUCTED AND INSTALLED IN ACCORDANCE WITH THE LATEST SMACNA FIBROUS DUCT CONSTRUCTION STANDARDS. PROVIDE R =4.6 INSULATION PER FLORIDA ENERGY CODE. METAL DUCTS SHALL BE IN ACCORDANCE WITH LATEST ISSUE OF THE LOW VELOCITY DUCT CONS- TRUCTION STANDARDS, PUBLISHED BY THE "SHEET METAL AND AIR CONDITIONED CONTRACTORS NATIONAL ASSOCIATION, INC." AND THE LATEST PUBLICATION OF GUIDE & DATA BOOK OF THE AMERICAN SOCIETY OF HEATING, VENTILATING AND AIR CONDITIONING ENGINEERS. 6- CONTRACTOR SHALL PROVIDE POSITIVE MEANS FOR BALANCING EACH INDIVIDUAL AIR CONDITIONING SUPPLY AIR OUTLET, AS PER SCHEDULES AND DRAWING, SYSTEMS SHALL BE BALANCED AGAINST THE ACTUAL INSTALLED STATIC PRESSURE. 7- BEFORE SUBMITTING FINAL PROPOSAL, THE CONTRACTOR SHALL EXAMINE THE SITE OF THE PROPOSED WORK TO DETERMINE THE EXISTING CONDITIONS THAT MAY AFFECT HIS WORK AS HE WILL BE RESPONSIBLE FOR ANY ASSUMPTIONS MADE BY HIM IN REGARDS THERETO, 8- ANY APPARATUS, APPLIANCE, MATERIALS, WORK OR INCIDENTAL ACCESSORIES OR MINOR DETAILS NOT SHOWN BUT NECESSARY TO MAKE THE INSTALLATION COMPLETE AND FUNCTIONAL IN ALL RESPECTS AND READY FOR OPERATION, EVEN IF NOT PARTICULARLY SPECIFIED, SHALL BE PROVIDED BY THE CONTRACTOR WITHOUT ANY ADDITIONAL EXPENSE FOR THE OWNER, AS PART OF MEANS AND METHOD OF INSTALLATION. 9- VIBRATION ISOLATION PROVIDE SUPPORTS OR MOUNTS FOR ALL EQUIPMENT LOCATED WITHIN THE BUILDING STRUCTURE POWERED BY ONE HORSEPOWER OR LARGER MOTOR. FLEXIBLE PIPING CONNECTIONS SHALL BE PROVIDED FOR ALL PIPING CONNECTED TO EQUIPMENT MOUNTED OR SUPPORTED BY VIBRATION ISOLATORS, 10- ALL WORK SHALL BE FIELD CHECKED BEFORE INSTALLATION AND COORDINATED WITH ALL OTHER TRADES. 11- ALL MECHANICAL EQUIPMENT INSTALLED ON THE EXTERIOR OF THE BUILDING SHALL BE CONSTRUCTED TO WITHSTAND A WIND PRESSURE OF 60 PSF (120 MPH WINDS) FROM ANY DIRECTION. 12- ALL SIZES SHOWN FOR LINED AND .UNLINED DUCTS ARE CLEAR INSIDE DUCT DIMENSIONS. 13- COORDINATE LOCATION OF DUCTWORK WITH OTHER TRADES, PARTICULARLY WHERE DUCTS RUN THROUGH STRUCTURAL 14- ALL CONTROL WIRING SHALL BE THE RESPONSIBILITY OF THE MECHANICAL SUBCONTRACTOR MECHANICAL SUB CONTRACTOR TO FURNISH ALL MOTORS, STARTERS, AND RELAYS, ETC. 15- A/C CONTRACTOR IS RESPONSIBLE FOR OBTAINING HIS OWN PERMIT AND PAYING ALL PERMIT FEES. 16- CONTRACTOR SHALL ASSUME RESPONSIBILITY FOR ALL COSTS INCURRED RESULTING FROM SUBSTITUTION OF EQUIPMENT AS WELL AS THE PERFORMANCE OF SUCH EQUIPMENT. ALL TESTS SHALL BE PERFORMED AS REQUIRED DURING THE DIFFERENT STAGES OF WORK AND A FINAL 24 HOURS MINIMUM RUNNING TEST SHALL BE DONE AFTER ALL OTHER TESTS AND BALANCING OPERATIONS HAVE BEEN DONE. PROVIDE A BALANCING INDEPENDENT TEST & BALANCE REPORT TO ENGINEER FOR REVIEW. 17-- TESTS 18- PROVIDE ALL NECESSARY INSTRUCTIONS TO THE OWNER IN THE OPERATION OF THE MECHANICAL SYSTEMS. 19- PROVIDE EQUIPMENT OPERATION AND MAINTENANCE MANUALS. MANUALS SHALL BE SUBMITTED TO THE ARCHITECT FOR ACCEPTANCE. 20- SUBMIT SHOP DRAWINGS FOR ACCEPTANCE BY THE ARCHITECT AND /OR ENGINEER BEFORE PROCEEDING WITH PURCHASE OR INSTALLATION OF THE EQUIPMENT AND MATERIALS. 21- GUARANTEE CONTRACTOR SHALL FURNISH A WRITTEN GUARANTEE COVERING ALL WORMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE. HVAC DESIGN REQUIRES: YES NO DUCT SMOKE DETECTOR X COMMENTS FIRE DAMPER(S) COMMENTS X SMOKE DAMPER(S) ML -38 X FIRE RATED ENCLOSURE X PROVIDE W/ PLENUM MODEL MP -38 FIRE RATED ROOF /FLOOR CEILING ASSEMBLY O X FIRE STOPPING X DAMPER. 24x24 MODULAR. SMOKE CONTROL SUPPLY X SUPPLY/ RETURN AIR DIFFUSER SCHEDULE DIFFUSER # USE TYPE MANUFACTURER COMMENTS CFM PER FOOT COMMENTS A & MODEL No. ML -38 4 SUPPLY CEILING PROVIDE W/ PLENUM MODEL MP -38 RECTANGULAR DIFUSER WITH OPPOSED BLADE O AIR DIFFUSER TITUS, 7MS DAMPER. 24x24 MODULAR. O SUPPLY CEILING TITUS, 250 AA RECTANGULAR DIFUSER WITH OPPOSED BLADE AIR TEMP. ENT. EVAP., DB /WB AIR DIFFUSER 530 DAMPER. O SUPPLY WALL TITUS, 300 FS OPPOSED BLADE DAMPER. 10/15 AIR REGISTER .140 TCGD18S21S2 TCGD60S43Sl RETURN CEILING 18HX EGG CRATE RETURN AIR REGISTER WITH a AIR GRILLE TITUS, 50F ADJUSTABLE AND OPPOSED BLADE DAMPER. SPLIT, DX RETURN CEILING SEER /EER - -/11.2 a AIR GRILLE TITUS, PAR PERFORATED, 24x24 MODULAR. LINEAR SUPPLY AIR DIFFUSER SCHEDULE DIFFUSER # MANUFACTURER MODEL # SLOTS SLOTS WIDTH CFM PER FOOT COMMENTS A TITUS ML -38 4 3/4" 25 CFM /FT PROVIDE W/ PLENUM MODEL MP -38 OUTDOOR AIR CALCULATIONS AS PER F.B.C. 2007. ASHRAE TABLE 6,1 ADDENDUM 62N -2001 AREA FLOOR PERSONS/ TOTAL CFM / CIFM / CFM CFM SYSTEM DESIGNATION AREA (FT2) 1000 FT2 PERSONS PERSON FT2 REQUIRED PROVIDED DESIGNATION GF RETAIL AREA 2215 15 33 16 AIR TEMP. ENT. EVAP., DB /WB -- 528 530 AHU -1(N) 2F CORRIDOR /BOH 2335 -- -- -- 10/15 0.06 140 .140 TCGD18S21S2 TCGD60S43Sl A.H.U. MODEL NC090C00C6AAA1 18HX AHP60D3XH21 MANUFACTURER YORK YORK /FIRST CO. YORK UNIT TYPE SPLIT, DX SPLIT, DX SPLIT, DX SEER /EER - -/11.2 13.25/ -- 13.00/ -- AHU WEIGHT (LBS.) AHU -5(E), 6(E) 2F PRIVATE. OFFICE 90 7 1 20 __ 20 20 80 CFM EA 2F STUDIO A 1080 30 2 20 -- 640 640 (N) FLEXIBLE DUCTWORK W /COLLAR 320 CFM EA 2F STUDIO B 66 30 19 20 __ 380 380 AHU -3(N) G B.O.H. 25 -_ __ - 0.12 30 30 AHU -2(E) ENTRY STAIRS 173 -- - -- 0.06 10 30 AHU -2(N) AHU /CU SCHEDULE I UNIT NUMBER AHU -1 CU -1 FC -2 CU -2 FC -3, 4A, 4B CU -3, 4A, 413 M SUPPLY CFM / 0/A CFM 3000/530 600/30 1600 /SEE SCHEDULE TOTAL CAPACITY, BTU /HR. 96,000 17,500 60,930 SENSIBLE CAPACITY, BTU /HR: 57,670 13,000 39.7 HEATER CAPACITY (K.W.) 7,5 3 7.5 AIR TEMP. CONDENSER 95 'F 95 'F 95 'F AIR TEMP. ENT. EVAP., DB /WB 80'/6T 80'/67' 80'/6- VOLTAGE, PHASE 230/30/60 230/10/60 230/10/60 MCA /MOP 35.5/45 10/15 23.9/40 CONDENSING UNIT MODEL YC090C0OA2AAA1 TCGD18S21S2 TCGD60S43Sl A.H.U. MODEL NC090C00C6AAA1 18HX AHP60D3XH21 MANUFACTURER YORK YORK /FIRST CO. YORK UNIT TYPE SPLIT, DX SPLIT, DX SPLIT, DX SEER /EER - -/11.2 13.25/ -- 13.00/ -- AHU WEIGHT (LBS.) 401 88 180 AHU DIMENSIONS (HxWxD) 65x56x30 11x37.25x21 21.5x24.567 COND.UNIT WEIGHT (LBS.) 330 110 210 NOTE: PROVIDE RAWAL VALVE AND SUCTION ACCUMULATOR FOR AHU /CU -3, 4A AND AB HVAC LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION X XXX DESIGNATION FOR SUPPLY DIFFUSER LETTER AND CFM I / I RETURN AIR GRILLE DESIGNATION FOR RETURN REGISTER NUMBER CEILING DIFFUSER XXXX AND CFM AIR HANDLING UNIT NEW FIBERBOARD DUCTWORK ITT) THERMOSTAT ill ELBOW WITH TURNING VANES FIRE DAMPER /SMOKE DAMPER FD /SD WITH ACCESS PANEL !� FD FIRE DAMPER REDUCERS AS INDICATED SUPPLY REGISTER OR GRILLE (VERTICAL MOUNT SIDEWALL) VD R/A RETURN /EXHAUST REGISTER OR STANDARD BRANCH TAKE -OFF E===- GRILLE (VERTICAL MOUNT SIDEWALL) O.A. LOUVER FLEXIBLE DUCTWORK W /COLLAR WITH VOLUME DAMPER EF- EXHAUST FAN (CEILING TYPE) 4247 SW 71st AVENUE Miami, Florida 33155 I Tel: (305) 661 -080U Fax: (305)661 -0811 Email: uci @ucieng.corn R.J. Miranda P.E. No. 35579 David A. Belsky P.E. No. 37234 EB0004041 Professional Electrical and Mechanical Engineers BLITSTEIN DESIGN ASSOCIATES Architecture Interior Design 285 Sevilla Avenue Coral Gables, Fl 33134 (305) 444 -4433 project name Existing Building Renovation for Continental Fidelity Corporation 5734 Sunset Drive South Miami, Florida project number date 12/07/09 revision drawn by AR, F.G, J.L, G.R sheet title SCHEDULES AND NOTES SCALE: 1/4" = I`-Oil sheet number M -3