09-1112-030LL W �-
��Cg
NEW DRYWALL
CLG CH- & -0"
(>- � 0
1 O�8
CFM B
0
�I
o
4247 SW 71st AVENUE
s h e e t number
Miami, Florida 33155
Tel: (305) 661 -0800
Fax. (305) 661-0811
' Email: uci @ucieng.com
M=2
R.J. Miranda P.E. No. 35579
I
David A. Belsky P.E. No. 37 "234
EB0004041
Professional Electrical and
Mechanical Engineers
i :
41
=
li
DRYWALL
L CH- 9' -0" -E )-
i
1t
f 0 CL FAN CL FAN BY TENANT BY TENANT
BY TENANT
_0
I 0
_ NEW DRYWALL
0 SOFFIT CH- 8' -0' ,
_1 . -.� 0x8 _. VD
18x8 -
-- �>
' 57"
57
57"
57"
1
...... .. . .., ,. .,.... R d_ ., .....,, ....r „,.: -.a7. ..,,,..5._._.. ...«..,..,.s.. _ m. ..,... �; .,.. .. ............ ....
KEY NOT
®- EXISTING 0/A DUCT FROM ABOVE TO REMAINS ENCLOSE IN
TWO HOUR RATED ENCLOSURE INSIDE THIS SPACE.
0- EXISTING AHU'S TO BE RELOCATE WHERE SHOWN, VERIFY OPERATING CONDITIONS,
REFRIGERANT LOAD, REPLACE FILTERS AND CLEAN COIL. RE- CONNECT O/A DUCT TO
EXISTING AND RE- BALANCE O/A TO MATCH SCHEDULED. EXTEND REFRIGERANT PIPES
TO THE NEW LOCATION. RECONNECT EXISTING A/C CONDENSATE ALSO.
Q- REMOVE EXISTING A/C UNIT AND ASSOCIATED DUCTWORKS AND
HAUL FROM SITE.
®- NEW AHU SUSPENDED FROM STRUCTURE, PROVIDE AUXILIARY DRAIN
PAN.
5( )- REFRIGERANT PIPES FROM BELOW AND UP TO CONDENSING UNIT ON ROOF
STAND ENLARGE EXISTING ROOF OPENING AND PROVIDE NEW PIPING CURB,
RE -SEAL AIR TIGHT. COORDINATE WITH THE LANDLORD CONDENSING UNIT AND
ROOF STAND LOCATION.
(g)- REMOVE EXISTING 7.5 TONS CONDENSING UNIT AT LOCATE
NEW CONDENSING UNIT ON EXISTING ROOF STAND.
VERIFY ON SITE EXACT LOCATION. SECURE TO RESIST HURRICANE
WINDS FORCES AS PER F.B.C.
®- 6 "0 COMBINED TOILET EXHAUST DUCT UP TO 6 "0 ROOF JACK WITH W.M.S.
®- 1" UNDERCUT DOOR.
9Q- 12x12 0/A DUCT UP TO ROOF GOOSENECK WITH W.M.S.
®- 10 "0 O/A DUCT UP TO ROOF GOOSENECK WITH W.M.S.
PROVIDE MOTORIZED DAMPER, MODULATE TO OPERATE OPEN OR CLOSED MODE
ACCORDINGLY WITH A/C UNIT STAGE, (ON OR OFF)
OFFSET MIN 10FT FROM ANY PLUMBING VENT OR MECHANICAL
OUTLET. (TYPICAL FOR ALL MAKE UP AIR)
0
0
16x1
0
0
0
NEW 2x2 DROP
CLG CH- 9' -0"
— w e
4 6 — _.:. 6 5
4 j O 12x1 O 0�...- "o
10x8
-
4260- REF 6 "0
r'y< 100
„
- - 16x16 FI I \ -n
�< _
(J (� O Cil I I �� 0 O C_) �" 3
s
--
�r,, 14x 14 14x 12 1 x 10
(� III
- -- VD(
I J
III
NEW DRYWALL
SOFFIT CH- 8' -0"
6 3004 2 C N OA II
30x8 2 _ ( 4 20x6 ®
C .) \ J 400 CFM EA -
FM
� 4 ^ _ILNY T - (: - t
CL�3CH -9. 0„ t�, f 4
( I_G FAN CL AN
CL FAN CL FAN BY TENANT
BY TENANT BY TENANT BY T NANT
8x8
120 CF
M
0 _
� _
4 20x6
370 CFM EA D RY
_LEW
So
�P
16x15 14x14 14x12 10x10
O 0 O 0 0 O 0 O 0 0
mn
.. .. ...,e.e .:..:.. ..... .. ..... .a,,....,_.!..��.g x. `fir�.,,,.... a.. .� ., ..,., ,,... ..,., �.ye.� n. .1°� .a.. ..... ,.. .:. ,.... .. � .o,.
........ ...... ,... _._.. �s........:.r .- ...., . _ ..._...._ r - .._s:i-.� �,»..,,,.t.......e: ..._,.,e..w v. .....:.:.. ..e..,... ..:>___... ,...d� u� «�,.e �s:...F�?.. _..:.«�..,.. �.......... __. mx_.......:.a.,..,»�
MECHANICAL - SECOND FLOOR - CEILING PLAN
SCALE: 1/411 = 1• -0•'
CFM
BLITSTEIN
DESIGN
ASSOCIATES
Architecture
Interior Design
285 Sevilla Avenue
Coral Gables, Fl 33134
(305) 444-4433
project
name
Existing Building
Renovation for
Continental
Fidelity
Corporation
5734 Sunset Drive
South Miami, Florida
project number
date
12/07/09
revision
1Q 05/26/10 B.D.C.
drawn by
AR, F.G, J1, G.R
sheet title
MECHANICAL
SECOND FLOOR -
CEILING PLAN
SCALE: 1/4" = 1' -0”
4247 SW 71st AVENUE
s h e e t number
Miami, Florida 33155
Tel: (305) 661 -0800
Fax. (305) 661-0811
' Email: uci @ucieng.com
M=2
R.J. Miranda P.E. No. 35579
I
David A. Belsky P.E. No. 37 "234
EB0004041
Professional Electrical and
Mechanical Engineers