Loading...
09-1112-022SILICOI` SEALAP 9/16" LP GLASS VINYL ALUM.' .. ... ,.. DOORFRAME VN min 1in D Q a 1/4" DRYWALL K HIM - 3/4" P.T. WOOD BUCK CONC. TAPCONS SEE MANUF" SHOP DWGS FOR SIZE & SPACING �-- SEALANT SILICONE SEALANT - 9116" LAM SAFETY GLASS VINYL ALUM.STOREFRONT FRAME 5/8" STUCCO FRAME DIMENSION - MASONRY OPENING EXT. CONC. / JAMB 1 STOREFRONT JAMB SCALE: 3" = V -0" TYPICAL: G.C. TO SUBMIT SHOP DRAWINGS. SEE STOREFRONT &WINDOW MANUFACTURER'S SHOP DRAWINGS 3/5/201p 1:01:27 PM ., , DOOR STILE EXT. STOREFRONT DOOR / JAMB Q SCALE: 3" = V -0" CONC. TAPCONS SEE MANUF. SHOP DWGS FOR SIZE & SPACING 5/8" STUCCO - v SEALANT O z VINYL z O z a z O 'w 2 z 9/16" LAM SAFETY O GLASS Q 0 0 ° x 3/4" P.T. WOOD BUCK SHEAR BLOCK ALUM. STOREFRONT FRAME SILICONE SEALANT STOREFRONT HEAD CONC. TAPCONS SEE MANUF. SHOP DWGS FOR SIZE & SPACING 5/8" STUCCO V a SEALAN (D z Z O z U) w z a w o :5 LU SCALE: 3" = V -0" a ;4\— 3/4" P.T. WOOD BUCK SHEAR BLOCK ALUM. STOREFRONT DOORFRAME ALUM. STOREFRONT DOOR STILE 7/16" LAM SAFETY GLASS EXT. VINYL ALUM. STOREFRONT FRAME SHEAR BLOCK SEALANT V STOREFRONT DOOR HEAD SCALE: 3" = 1' -0" 9/16" LAM SAFETY GLASS SILICONE SEALANT FIN. FLOOR CONC. SLAB SEE STRUCT. � � V c- CONC. TAPCONS SEE MANUF. SHOP DWGS FOR SIZE & SPACING STOREFRONT SILL SCALE: 3" = 1' -0" CONC. TAPCONS SEE MANUF. SHOP DWGS FOR SIZE & SPACING THRESHOLD SCALE: 3" = 1' -0" 7116" LAM SAFETY 518" DRYWALL OVER GLASS a ALUM. STOREFRONT EXT, DOOR STILE @1F "O.C. - GASKET ,,PPROVEa €3Y- _ FIN. FLOOR ;_ CONC, SLAB SEE CCNC. LINTEL STRUCT. ALUM. SEE STRUCT. DWGS THRESHOLD -\ = X CONC. TAPCONS SEE MANUF. SHOP DWGS FOR SIZE & SPACING THRESHOLD SCALE: 3" = 1' -0" OMETAL STUD PARTITION CONCRETE WALL HOLLOW METAL DOOR FRAME HEAD DETAIL JAMB SIMILAR STOREFRONT & GLAZING NOTES SCALE 3" =1' -0" LARGE MISSILE IMPACT RESISTANT PRODUCTS: GENERAL CONTRACTOR TO PROVIDE SHOP DRAWINGS 1. All Storefront ARCH ALUMINUM SERIES IMPACT WALL 3000 (N.O.A. 09- 0122.06) IMPACT RESISTANT, GLAZED W/ 9/16" OVERALL LAM. COMPOSED OF: 1/4" GLASS HS + 0.09 INNER LAYER'SENTRY GLASS PLUS' + 1/4" GLASS HS 2, All Storefront Doors ARCH ALUMINUM SERIES IMPACT 3000 STOREFRONT DOOR (N.O.A, 09- 0105.01) IMPACT RESISTANT, DOOR LEAF GLAZED W/ 3116" HS + 0.09 INNER LAYER + 3/16" GLASS HS 3_ ANCHORS SHALL BE OF TYPE, & SPACED AS SHOWN ON MANUF. SHOP DRAWINGS EMBEDMENT INTO BLDG SUBSTRATE BEYOND WALL FINISHES OR STUCCO. 4. ALL STEEL IN CONTACT WITH ALUMINUM IS TO BE PAINTED WITH A COATING OF A HEAVY BODIED BITUMINOUS PAINT OR APPLY A NON - ABSORPTIVE TAPE OR GASKET. 5. EXISTING STRUCTURE MUST SUPPORT THE LOADS IMPOSED BY GLAZING SYSTEM. BLITSTEIN DESIGN ASSOCIATES Architecture Interior Design 285 Sevilla Avenue Coral Gables, FI 33134 (305) 444 -4433 Y" r ' �1 project name Existing Building Renovation for Continental Fidelity Corporation 5734 Sunset Drive South Miami, Florida project number date 04/05/10 revision a 4. 518" DRYWALL OVER a 7/8" MTL FURRING STRIPS TRUr,TURAL SECT10M @1F "O.C. 5/8" STUCCO ,,PPROVEa €3Y- _ ;_ Q i CCNC. LINTEL SEE STRUCT. DWGS a a (---' ANCHORS Sll (2 @ HEAD, 3 @ EACH JAMB) AS PER DADE COUNTY REQUIREMENTS MTL S II I LAYER OF 'WALL EACH SIDE. l " -7- -mow - - r�-1--- .—.7- ^--'�--,- II, ! LLOW METAL EXTERIOR `_--_HOLLOW METAL 4ME FRAME (FILL W/ GROUT) INTERIOR HORS ig HEAD, 3 @ EACH JAMB) HOLLOW METAL DOOR OR OMETAL STUD PARTITION CONCRETE WALL HOLLOW METAL DOOR FRAME HEAD DETAIL JAMB SIMILAR STOREFRONT & GLAZING NOTES SCALE 3" =1' -0" LARGE MISSILE IMPACT RESISTANT PRODUCTS: GENERAL CONTRACTOR TO PROVIDE SHOP DRAWINGS 1. All Storefront ARCH ALUMINUM SERIES IMPACT WALL 3000 (N.O.A. 09- 0122.06) IMPACT RESISTANT, GLAZED W/ 9/16" OVERALL LAM. COMPOSED OF: 1/4" GLASS HS + 0.09 INNER LAYER'SENTRY GLASS PLUS' + 1/4" GLASS HS 2, All Storefront Doors ARCH ALUMINUM SERIES IMPACT 3000 STOREFRONT DOOR (N.O.A, 09- 0105.01) IMPACT RESISTANT, DOOR LEAF GLAZED W/ 3116" HS + 0.09 INNER LAYER + 3/16" GLASS HS 3_ ANCHORS SHALL BE OF TYPE, & SPACED AS SHOWN ON MANUF. SHOP DRAWINGS EMBEDMENT INTO BLDG SUBSTRATE BEYOND WALL FINISHES OR STUCCO. 4. ALL STEEL IN CONTACT WITH ALUMINUM IS TO BE PAINTED WITH A COATING OF A HEAVY BODIED BITUMINOUS PAINT OR APPLY A NON - ABSORPTIVE TAPE OR GASKET. 5. EXISTING STRUCTURE MUST SUPPORT THE LOADS IMPOSED BY GLAZING SYSTEM. BLITSTEIN DESIGN ASSOCIATES Architecture Interior Design 285 Sevilla Avenue Coral Gables, FI 33134 (305) 444 -4433 Y" r ' �1 project name Existing Building Renovation for Continental Fidelity Corporation 5734 Sunset Drive South Miami, Florida project number date 04/05/10 revision SCALE: AS SHOWN sheet number A -10 drawn by c -yy OF SOUTH MIAMI BUILDING DEPT. D. M. TRUr,TURAL SECT10M sheet title ,,PPROVEa €3Y- _ ;_ DETAILS SCALE: AS SHOWN sheet number A -10