Loading...
09-1112-006PROPE�LINE F- I I I I I I I I W Z J I Ir a�I W D_ O 0 I D_ �_J 4' -0" J U I- U LU _J LL! U) W T -4" EXIST, V I Q u o P CL 1 co u .� O w X W W I z V) I I- A U) 1/2" m. J _U W �yJ� a L — — — 1, — — — ( EXIST. D.S — — — — — PROPERTY LINE PROVIDE SIGN READING "NO STORAGE" EXIST. PANELS SEE ELECT. 14' -1" EPA �J SEE MECH. DWGS !NEW HI-LOW 10, DRINKING FOUNTAIN CLOSE OPENING REPAIR DAMAGE TO FLOOR <V RESTORE DRYWALL PARTITION EXISTING _ PARTITIONS TYP. PATCH DRYWALL PATCH DRYWALL <14z PATCH DRYWALL PATCH DRYWALL EXISTING EXTERIOR PRE -CAST CONC. WALL 79' -6„ 32' -10" 26,_6, Z-1 —.—.—.—._..-_.—._._.— ._.— .— ._.— .— .— .— ._.— .— .— . —.—._ \ A9 FURR OUT FROM EXIST. Cl _ .........,. WALL, PROVIDE INSULATION . ............... . . . .. .. - - -" .. ._ ... .... - - - - - -T -NEW --;--------i-------`r.....----.;- E ST IR NOTE: EXCEPT FOR EXISTING BACK ROOM, THERE SHALL BE NO EXPOSED WALL SURFACES. ALL EXPOSED EXTERIOR WALLS TO BE FURRED OUT W/ METAL FURRING STRIPS & %" DRYWALL. RETAIL TENANT 1 FLOOR - BY FUTURE TENANT BASE - MATCH EXIST. WALLS - IP1 CEILING - CP1 FURR OUT FROM EXIST- WALL . PROVIDE INSULATION 84' -6" EXIST. COLUMNS PROVIDE 1 hr FIRE PROTECTION — 5 11,_5„ 5„ ------ ------ . ------ ------ 16-0" 22,_5" ao 2 �D 0 STIR COL.' DOOR NO. LOCATION DOOR T..... WIDTH 7 THICK i FRAME I SEE SHT A -4 HARDWARE 0: ... -...1. '. ..-----� BBY - P 1 sz . re�1 RATING I TENANT 1 ENTRANCE 2 3' -0" EXISTING 7314" AL P -.... ELEVATOR PU, CL, DB, DS PA, PU, CL, DS B NOT RATED NOT RATED TO REMAIN SEE SHT A-4 EXIST. EXTERIOR DOOR q„ 8' -0" 1 -3/4" AL AL 3 A -7 23 1:3 ELEVATOR LOBBY T -0" _ 7' -0" 1 -3/4" -• —/ U) 1 LH, CL (CLOSER), DS B 60 MIN _ , _ , _ • _ _ , PATCH SEE SH f A -4 T -0" 6, -5" DRYWALL WD W EXISTING ELEVATOR CAB, HOIST -WAY, ALL ASSOCIATED SYSTEMS TO BE SERVICED, CLEANED, & REFURBISHED TO LIKE NEW CONDITION. ELEVATOR COMMUNICATION SYSTEM TO BE REPLACED W/ NEW SYSTEM MEETING CURRENT CODE STANDARDS �B I G.C. TO COORDINATE W/ ^ ELEVATOR CONSULTANT. TYPICAL: SURFACE MOUNTED, 51b ABC FIRE EXTINGUISHER MOUNT 48" AFF, PROVIDE REQ. BACKING. PATCH i -- PROPERTY LINE DRYWALL @ SILL, PROVIDE .r""'^ INSULATION ❑3 LU SEE SHT A -4 ® U) 1/2" m X SEE SHT A -4 - 8 m SEE SHT AA RETAI TENANT ENT�ANCE _ N I� PATCH SEE SHT A -4 1 DRYWALL @ SILL, PROVIDE I I� INSULATION ltl 1 7 SEE SHT A -4 FIRST FLOOR PLAN. - .r FIRST LEVEL DOOR SCHEDULE DOOR NO. LOCATION DOOR REMARKS WIDTH HEIGHT THICK I MAT'L FRAME TYPE HARDWARE LABEL RATING 1:1 TENANT 1 ENTRANCE 2 3' -0" 8' -0" 7314" AL AL 1 PU, CL, DB, DS PA, PU, CL, DS B NOT RATED NOT RATED EXISTING TO REMAIN. VERIFY TO DE REFINISHED W/ E.S.P. PROCESS INT. & EXT. 1:2 EXIST. EXTERIOR DOOR T -0" 8' -0" 1 -3/4" AL AL 3 23 1:3 ELEVATOR LOBBY T -0" _ 7' -0" 1 -3/4" HM HM 1 LH, CL (CLOSER), DS B 60 MIN 2:4 BATHROOM 3' -0" T -0" 1 -3/4" SC WD 2 1:4 CLOSET T -0" T-0" 1 -314" HM HM 1 BATHROOM T -0" " T -0" 1-3/4" SC WD 2 LH3, DS LH, CL, DS, Z LH, CL, DS, Z LF CL, DS, Z C C C 45 MIN 45 MIN 45 MIN SOUNDPROOF SOUNDPROOF SOUNDPROOF 2:6 1:5 EXIST. WATER HEATER CL 2'4" T -0" 1 -3/4" WD 2 2:7 STUDIO 'B' T -0" T -0" EXISTING TO REMAIN. VERIFY. REFURBISH DOOR & SC WD 2 2:8 STUDIO 'A' -'B' T -0" T -0" 1 -3/4" 16 H.C. BATHROOM 1 3' -0" T -0" 1 -3/4" 3' -0" T -0" 1 -3/4" SC WD HARDWARE 1:7 H.C. BATHROOM 2 3' -0" T -0" 1 -3/4" 2:10 STUDIO 'A' 1:8 BACK ROOM 3' -0" T -0" WD 2 LH, CL, Ds, z LH1, CL, DS C 1:9 1 AHU CLOSET 6' -0" T -0" 3' -0" 7' -0" 1 1 -3/4" SC WD 2 1:10 REAR STAIR T -0" 6' -8" 1 -3/4" cL PA, CL C 4; 1 ri 7�;i /I 1:11 REAR EXIT 3' -0" 6-8" 1 -314" _ 1:12 REAR EXIT (2) T -0" CL 113 EXIST. ELECT. CLOSET 3' -0" 6' -8" 1 -3/4" SECOND LEVEL DOOR SCHEDULE DOOR NO. LOCATION DOOR REMARKS WIDTH HEIGHT THICK I MAT'L FRAME TYPE HARDWARE LABEL RATING 2:1 FRONT STAIR T -0" 7-0" 1 -3/4" HM HM 1 LH, CL (CLOSER), DS B 60 MIN EXISTING REUSED. VERIFY. REFUR3ISH DOOR & 2:2 ELEV EQUIPMENT RM 3' -O" 6' -8" 1 -3/4" 23 REAR STAIR 3' -0" T -0" 1 -314" HM HM 1 LH, CL (CLOSER), DS B 60 MIN HARDWARE 2:4 BATHROOM 3' -0" T -0" 1 -3/4" SC WD 2 2:5 BATHROOM T -0" " T -0" 1-3/4" SC WD 2 LH3, DS LH, CL, DS, Z LH, CL, DS, Z LF CL, DS, Z C C C 45 MIN 45 MIN 45 MIN SOUNDPROOF SOUNDPROOF SOUNDPROOF 2:6 CLOSET 3' -0" 7' -0" 1 -3/4" SC WD 2 2:7 STUDIO 'B' T -0" T -0" 1 -3/4" SC WD 2 2:8 STUDIO 'A' -'B' T -0" T -0" 1 -3/4" SC WD 2 2:9 STUDIO W 3' -0" T -0" 1 -3/4" SC WD 2:10 STUDIO 'A' 7' -0" 1 -3/4" SC WD 2 LH, CL, Ds, z LH1, CL, DS C 45 MIN SOUNDPROOF 2:11 MANAGER'S OFFICE 3' -0" 7' -0" 1 1 -3/4" SC WD 2 SCALE: 1/411 HARDWARE LEGEND DOOR TYPES } a� TYPE DESCRIPTION (VERIFY FINISHES WITH OWNER) 0 IF° X LE AI LC , vuw I o-.n 1 wC MS QMG r,CL DOOR CLOSER 8.5 Ibf EXT. - 5 Ibf INT. O°C LE u SAV T ° HsN nwE j 1 -f1T' n 3 Wl Q ,` `I i Y( nwncen wuy CLH HIDDEN DOOR CLOSER - -? HOLLOW � 'S! 1 OQ HEAVY DUTY DEAD BOLT LOCK, KEY EXT., T -TURN INT. METAL �L DS DOORSTOP / Roo Roolvi l+ -1 r- q��./'. ✓, H DOOR NOTES - 1. NEW EXT. DOORS TO BE DADE CO. APPROVED FOR IMPACT. G.C. TO PROVIDE SHOP DRAWINGS & N.O.A. No. 2. TYPICAL FOR ALL - VERIFY FINISHES WITH OWNER _ 3. SEE ELEVATIONS FOR + AND - PRESSURE VALUES. 4. TYPICAL, VERIFY ALL ROUGH OPENING SIZES W/ DOOR MANUFACTURER. EXISTING BUILDING IS UN- SPRINKLERED & HAS NO FIRE ALARM SYSTEM. O MED. ALUMINUM STILES CHROME OFFSET U -PULLS (24•x1.5 "0) ARCH ALUMINUM IMPACT STOREFRONT UOOR NOA N00- 0105.51 0 c� 0 fn so 6� _ MAX 1:2 SLOPE — g 1" X (2x) MAX 1:12 SLOPE — y ® E TYPICAL ALL DOORWAYS: (NFPA 7.2.1.3) ELEVATIONS IN FLOOR LEVEL ON BOTH SIDES OF A DOOR SHALL NOT VARY BY MORE THAN 1/2" DOOR THRESHOLDS SHALL NOT EXCEED 1/2" IN HEIGHT. TYPICAL ILLFLOORS: (F.B,C. 11 -4.5.2) ALL TRANSITIONS BETWEEN FLOOR FINISHES TO BE FLUSH WHEREVER POSSIBLE. IF THIS IS NOT POSSIBLE THEN 1. A DIFFERENCE IN LEVEL <Y4' MAY BE VERTICAL W/O EDGE TREATMENT 2.A DIFFERENCE IN LEVEL %y" AND <& SHALL BE BEVELED W/A MAX 1:2 SLOPE 3. A DIFFERENCE IN LEVEL - & SHALL HAVE A RAMP W/ A MAX 1:12 SLOPE . A FLOOR TRANSITIONS A-2 SCALE: 3" = 1' -0" p k�y:eF' LEGEND SYMBOL DESCRIPTION EXISTING EXTERIOR WALLS 1 EXISTING INTERIOR PARTITIONS TO ' REMAI N NEW INTERIOR PARTITIONS �—^ y`F NEW 1hrRATED INTERIOR PARTITIONS "UL" #U419 II \ NEW SWING DOOR EXISTING SWING DOOR TO BE REUSED TOTAL SEGMENT > LIFE SAFETY - DIRECTION & DISTANCE OF EGRESS TYPICAL: SURFACE MOUNTED, 51b FE ABC FIRE EXTINGUISHER MOUNT 48" AFF, PROVIDE REQ. BACKING. BLITSTEIN DESIGN ASSOCIATES Architecture Interior Design 285 Sevilla Avenue Coral Gables, Fl 33134 (305) 444 -4433 project name Existing Building Renovation for Continental Fidelity Corporation 5734 Sunset Drive South Miami, Florida project number date 04/05/10 revision Al 04/06/10 COMMENTS drawn drawn by D. M. sheet title FIRST FLOOR PLAN SCALE: 1/4" = V-011 sheet number I A � CITY t)E t: OUTH MIAMI BUILDING C: E T. STRUCTURAL SiccT,wl A=2; APPROVED BY � : ',�