12-742-015t w m J ' z z w Y MECHANICAL SYMBOLS NOTE.. THIS IS A MASTER LEGEND AND NOT ALL SYMBOLS, ETC. ARE NECESSARILY USED ON THE DRAWINGS. PIPING CD CONDENSATE DRAIN (CD) ACD AUXILIARY CONDENSATE DRAIN (ACD) RL REFRIGERANT LIQUID (RL) RD REFRIGERANT DISCHARGE (HOT GAS) (RD) RS REFRIGERANT SUCTION (RS) HW5 HEATING HOT WATER SUPPLY (HWS) —HWR— — HEATING HOT WATER RETURN (HWR) CWS CHILLED WATER SUPPLY (CWS) -- — CWR- -- — CHILLED WATER RETURN (CWR) HS HEAT PUMP SUPPLY (HS) ---HR--- HEAT PUMP RETURN (HR) LRS LOW PRESSURE STEAM SUPPLY (LPS) — - --LPC LOW PRESSURESTEAM CONDENSATE(LPC) �-» --�- EXISTING PIPING TO BE REMOVED EXISTING PIPING TO REMAIN DIRECTION OF FLOW BALL VALVE --i:� CONTROLVALVE --- THREE -WAY CONTROL VALVE SHUTOFF VALVE CHECK VALVE --154 BALANCING VALVE WITH PRESSURE PORTS 10 i TRIPLE DUTY VALVE WITH PRESSURE PORTS ­- r WATER METER STRAINER SOLENOID VALVE — — PRESSURE GAUGE THERMOMETER To PRESSURE AND TEMPERATURE TEST PLUG -- II-- -- UNION — ,1—��- FLANGE CONNECTION ---10 ELBOW UP w ELBOW DOWN 0 TEE UP. TEE DOWN REDUCER HVAC EQUIPMENT & DUCTWORK NOTE: ALL DUCT DIMENSIONS SHOWN ON DRAWINGS ARE INSIDE DIMENSIONS. SEE SECTION 15250 OF THE SPECIFICATION FOR DUCTWORK TO RECEIVE INSULATION OR LINER. EXISTING DUCTWORK OR EQUIPMENT TO REMAIN EXISTING DUCTWORK OR EQUIPMENT TO BE REMOVED BRANCH DUCT WITH 45' RECTANGLE -ROUND BRANCH FITTING AND MANUAL VOLUME DAMPER ELBOW WITH TURNING VANES RETURN, EXHAUST, OR OUTSIDE AIR DUCT UP RETURN, EXHAUST, OR OUTSIDE AIR DUCT DOWN SUPPLY AIR DUCT UP SUPPLY AIR DUCT DOWN EQUIPMENT WITH FLEXIBLE DUCT CONNECTION ^ 10" S 300 CFM NECK K SIZE, E, TYPE, CFM OF SUPPLY DIFFUSER OR REGISTER MANUAL VOLUME DAMPER SQUARE TO ROUND TRANSITION �— DUCT MOUNTED SMOKE DETECTOR RD (SD= SUPPLY /RD- RETURN) Fp FIRE DAMPER FSD FIRE SMOKE DAMPER VD VOLUME DAMPER MD MOTORIZED DAMPER TS TEMPERATURE SENSOR O THERMOSTAT ABBREVIATIONS AFF ABOVE FINISHED FLOOR MC MECHANICAL CONTRACTOR BAS BUILDING AUTOMATION SYSTEM MIN MINIMUM BD BACKDRAFT DAMPER NC NOISE CRITERIA CFM CUBIC FEET PER MINUTE OA OUTSIDE AIR DDC DIRECT DIGITAL CONTROL RA RETURN AIR DX DIRECT EXPANSION SA SUPPLY AIR EA EXHAUST AIR SD SMOKE DUCT DETECTOR ETA FROM FLOOR ABOVE TEA TO FLOOR ABOVE FFB FROM FLOOR BELOW TFB TO FLOOR BELOW GPM GALLONS PER MINUTE TYP TYPICAL IN WC INCHES OF WATER COLUMN UNO UNLESS NOTED OTHERWISE MAX MAXIMUM W/ WITH MBH 1000 BTU PER HOUR W/0 WITHOUT STANDARD MOUNTING HEIGHTS MECHANICAL (AFF, AFG, UNLESS NOTED OTHERWISE) THERMOSTATS (USER ADJUSTABLE)(TOP OF DEVICE) 48" CONTROLS (TOP OF DEVICE) 4E" ANNOTATION OMECHANICAL PLAN CALLOUT CU MECHANICAL EQUIPMENT DESIGNATION (CONTRACTOR FURNISHED AND 1 INSTALLED UNLESS NOTED OTHERWISE) CONNECTION POINT OF NEW WORK TO EXISTING DETAIL REFERENCE UPPER NUMBER INDICATES DETAIL NUMBER LOWER M1 NUMBER INDICATES SHEET NUMBER 1 SECTION CUT DESIGNATION M1 GENERAL NOTES: 1. PRIOR TO SUBMITTING BID, VISIT THE JOB SITE AND BECOME FULLY ACQUAINTED WITH THE EXISTING CONDITIONS OF THE PROJECT. REVIEW THE GENERAL NOTES, SPECIFICATIONS AND OTHER DRAWINGS FOR ADDITIONAL REQUIREMENTS WHICH MAY NOT BE SPECIFICALLY CALLED OUT IN THIS PORTION OF THE CONSTRUCTION DOCUMENTS. NOTIFY ARCHITECT, ENGINEER AND /OR OWNER OF CONFLICTS OR DISCREPANCIES PRIOR TO SUBMISSION OF BID, 2. EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS AND SITE VISITS AND MAY NOT REFLECT EXACT "AS— BUILT" CONDITIONS. FIELD VERIFY EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. COORDINATE NEW WORK AND DEMOLITION WITH OTHER DISCIPLINES AND EXISTING CONDITIONS PRIOR TO CONSTRUCTION. 3. COORDINATE THE INSTALLATION OF THE MECHANICAL SYSTEMS WITH OTHER TRADES TO ENSURE A NEAT AND ORDERLY INSTALLATION. COORDINATE INSTALLATION OF DUCTWORK AND PIPING TO AVOID CONFLICTS WITH ELECTRICAL PANELS, LIGHTING FIXTURES. ETC. 4. AVOID DAMAGING EXISTING SURFACES AND EQUIPMENT TO REMAIN FOR NEW INSTALLATION DURING WORK. REPAIR DAMAGE CAUSED DURING CONSTRUCTION AT NO EXTRA COST TO THE OWNER. 5. ALL MECHANICAL EQUIPMENT SHOWN ON THE MECHANICAL PLANS SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR UNLESS OTHERWISE NOTED. 6. NEW MECHANICAL EQUIPMENT AND DUCTWORK ARE SHOWN AT APPROXIMATE LOCATIONS. FIELD MEASURE FINAL DUCTWORK LOCATIONS PRIOR TO FABRICATION AND MAKE ADJUSTMENTS AS REQUIRED TO FIT THE DUCTWORK WITHIN THE AVAILABLE SPACE, VERIFY THAT FINAL EQUIPMENT LOCATIONS MEET MANUFACTURER'S RECOMMENDATIONS REGARDING SERVICE CLEARANCE AND PROPER AIRFLOW CLEARANCE AROUND EQUIPMENT. 7. INSTALL DUCTWORK PARALLEL TO BUILDING COLUMN LINES UNLESS OTHERWISE SHOWN OR NOTED. E. OVERHEAD HANGERS AND SUPPORTS FOR EQUIPMENT AND DUCTWORK SHALL BE FASTENED TO BUILDING JOISTS OR BEAMS. DO NOT ATTACH HANGERS AND SUPPORTS TO THE ABOVE FLOOR SLAB OR ROOF. 9. COORDINATE LOCATION OF EQUIPMENT SUPPORTS WITH LOCATION OF EQUIPMENT ACCESS PANELS /DOORS TO ENABLE SERVICE OF EQUIPMENT AND /OR FILTER REPLACEMENT. 10. SEAL PENETRATIONS THROUGH THE BUILDING COMPONENTS IN ACCORDANCE WITH THE CONTRACT SPECIFICATIONS, FIREPROOF PENETRATIONS THROUGH FIRE RATED COMPONENTS IN ACCORDANCE WITH U.L. REQUIREMENTS. 11. COORDINATE THE EXACT MOUNTING SIZE AND FRAME TYPE OF DIFFUSERS, REGISTERS AND GRILLES WITH THE SUPPLIER TO MEET THE CEILING, WALL AND DUCT INSTALLATION REQUIREMENTS. 12. ADJUST LOCATION OF CEILING DIFFUSERS, REGISTERS AND GRILLES AS REQUIRED TO ACCOMMODATE FINAL CEILING GRID AND LIGHTING LOCATIONS. BRANCH DUCTWORK TO AIR OUTLETS SHALL BE SAME SIZE AS OUTLET NECK SIZE UNLESS OTHERWISE NOTED. 13. PROVIDE A NEW SET OF AIR FILTERS IN UNITS PRIOR TO TESTING, ADJUSTING AND BALANCING AND BEFORE TURNING SYSTEM(S) OVER TO OWNER. 14. ALL ROOF PENETRATIONS SHALL BE PERFORMED BY A LANDLORD APPROVED CONTRACTOR TO MAINTAIN WARRANTIES. 15. TENANT SHALL LOCATE ANY ROOF TOP VENTS A MINIMUM OF 10' AWAY FROM ANY ADJACENT ROOFTOP UNIT. 16. FIELD VERIFY EXISTING CONDITIONS AND THAT SPACE CONFORMS TO APPROVED LEASE OUTLINE DRAWING, AS APPROVED WITH LEASE AGREEMENT. 17. TENANT SHALL BE RESPONSIBLE FOR MEETING ALL APPLICABLE CODES AND OBTAINING ALL JURISDICTIONAL APPROVALS. PLAN NOTES: lO REMOVE EXISTING EXHAUST FAN AND ASSOCIATED DUCTWORK. CAP AND SEAL EXHAUST DUCT AS CLOSE TO WALL AS POSSIBLE. O GRILLE ABOVE DOOR AND COORDINATE BOTTOM OF GRILLE TO MATCH OTHERS IN SURROUNDING AREAS. O EXISTING 1200 OA DUCT WITH MOTORIZED DAMPER SHALL REMAIN. FIELD VERIFY DAMPER CONDITION, EXACT SIZE AND LOCATION PRIOR TO SUBMITTING BID, ADJUST OUTSIDE AIR DAMPER TO 580 CFM, O4 EXISTING 7 -1/2 TON CARRIER AIR HANDLING UNIT TO REMAIN. FIELD VERIFY EQUIPMENT CONDITION, EXACT SIZE AND LOCATION. EXISTING UNIT CONTROLS SHALL REMAIN. REBALANCE AIR HANDLING UNIT TO MEET NEW AIRFLOWS AS NOTED ON PLAN. OCOORDINATE INSTALLATION OF EQUIPMENT, DUCTWORK AND PIPING WITH ALL TRADES. DO NOT ROUTE DUCTWORK OR PIPING OVER ELECTRICAL PANELS. O EXISTING ROOF MOUNTED CONDENSING UNIT AND ALL ASSOCIATED REFRIGERANT PIPING AND CONTROLS TO REMAIN. O7 PAINT NEW EXPOSED DUCTWORK TO MATCH FINISHED CEILING. O SCOPE OF WORK BOUNDARY. MECHANICAL F SCALE: 3/ 16" =1' -0" AIR DISTRIBUTION DEVICE SCHEDULE (BASED ON TITUS) NOTES: 1. SYMBOL KEY - FIRST LETTER: S- SUPPLY R- RETURN E- EXHAUST T- TRANSFER. SECOND LETTER: D- DIFFUSER R- REGISTER G- GRILLE 2. BORDER STYLE - REFER TO REFLECTED CEILING PLAN 3. DAMPERS - OPERABLE FROM FACE - OB: OPPOSED BLADE ROB: RADIAL OPPOSED BLADE B: BUTTERFLY SIZE MOUNTING MATERIAL ACCESSORIES TAG MODEL REMARKS FACE NECK SIDE- CEILING DUCT FLOOR STEEL ALUM. DPR. EQUAL GRID FIRE DPR. WALL TITUS 22 -1/2" HORIZONTAL SD -1 272RS -14 -10 14 "x8" 12 "x6" 0 0 OB DEFLECTION 126AG -35 SD -2 TITUS TMR 14 "o 8 "0 0 0 ROB 8 "m NECK SD -3 TITUS TMR 22 "o 12 "0 0 0 ROB 12 "o NECK TITUS INSTALL BLADES FACING THE TG -1 355RL 14x14 12x12 0 0 - CEILING 12x12 TITUS INSTALL BLADES FACING THE TG -2 355RL 16x16 1414 0 0 CEILING 14x14 TITUS INSTALL BLADES FACING THE TG-3 355RL 14x14 12x12 0 0 WALL 12x12 TITUS RG -1 PAR 2424 22x22 0 0 24x24 TITUS INSTALL BLADES FACING THE RG -2 355RL 16x16 14x14 0 0 CEILING 14x14 w4VV VVV Y V •Yi•f ••V • } • } • •iii Y • • •re ! • r • • w Y • V• e V Y i bier: Yr• •YU w e r 46%ww Y : L • r1• u • • w • • u • Y • • u • u r • C1 • •w • Y!Y 0: fee b w Y Y • • : w Y • Y V b e i :• ••b •••• ••••• •e• iG•• V • • • • Y • wr Yr • Y V r • • • • V 1 r • ! • • • • w••} Y •i :•• Y •mow • uu•y • r�� - .._____ ................._ _j D 1 1' VERIFY ALL CONDITIONS IN FIELD IT IS THE RESPONSIBILITY OF THE MECHANICAL CONTRACTOR TO VISIT THE JOB SITE TO FAMILIARIZE HIMSELF WITH MAJOR ITEMS SUCH AS STRUCTURAL ELEMENTS, PLUMBING LOCATIONS, ELECTRICAL RUNS AND POINTS OF CONNECTION TO EXISTING DUCT SYSTEMS. ADDITIONALLY, MECHANICAL CONTRACTOR SHALLVERIFY EXACT LOCATIONS AND DIMENSIONS OF SUCH ITEMS AS HVAC EQUIPMENT, DUCTWORK, ETC. PRIOR TO COMMENCING ANY WORK. ALL HVAC WORK TO BE PERFORMED IN COMPLIANCE WITH LOCAL CODES AND LANDLORD CRITERIA. NOTE: INFORMATION ON THIS SHEET PERTAINING TO THE EXISTING MECHANICAL SYSTEMS IS BASED ON RECORD DRAWINGS AVAILABLE AT THE TIME OF DESIGN. FIELD VERIFY ALL EXISTING CONDITIONS AND NOTIFY ARCHITECT AND ENGINEER IMMEDIATELY IF ANY DISCREPANCIES ARE FOUND. NOTE: THE OWNER RESERVES THE RIGHT TO CHECK CONSTRUCTION COMPLIANCE WITH PLANS AND SPECIFICATIONS. SHOULD THE OWNER FIND CORRECTIVE WORK NECESSARY, HE WILL NOTIFY CONTRACTOR OF SUCH WORK IN WRITING AND EXPECT COMPLIANCE PERFORMED WITH DUE DILIGENCE. IF ANY CORRECTIVE WORK IS DEEMED TO BE NECESSARY, THE COST OF REINSPECTIONS WILL BE BORNE BY THE CONTRACTOR. IF WORK IS REQUIRED BY OWNER IN ORDER TO IMPROVE, CHANGE OR CORRECT AIR CONDITIONING OPERATIONAL CONDITIONS DUE TO: PART MALFUNCTION, WARRANTY OR OTHER INABILITY TO PROVIDE THE COMFORT CONDITIONS REQUIRED BY THE STORE, CONTRACTOR SHALL BE DIRECTED BY OWNER TO ADDRESS THIS WORK IN A TIMELY MANNER. IF IT BECOMES EVIDENT THAT THE CONTRACTOR CAN NOT ACCOMPLISH THE TASK, THEN AFTER 72 HOURS OF WRITTEN NOTICE, THE OWNER MAY AT HIS DISCRETION TAKE OVER SUCH WORK AND BACK CHARGE THE CONTRACTOR FOR ANY CORRECTIVE WORKTHAT WAS REQUIRED DUE TO LACK OF PERFORMANCE, WORKMANSHIP AND /OR ADHERENCE TO PLANS AND SPECIFICATIONS. ROOF NOTE: DO NOT ATTACH ANYTHING DIRECTLY TO THE UNDERSIDE OF THE DECK. VERIFY ALL CONDITIONS IN THE FIELD PRIOR TO BIDDING. VERIFY EXACT REQUIREMENTS PRIOR TO COMMENCING ANY WORK. x Ysi HENDERSON ENGINEERS= 8325 LENEXA DRIVE LENEXA, KS 66214 TEL 913 742 5000 rAx 913 742 5001 www hol- ons.Enm 1250000999 FL. (EF f �l WI I A18 7606