12-742-013
LIGHTING G N L OTES: LIGHTING KEYED NOTES: 1. LIGHTING SHALL BE CIRCUITED EXACTLY AS SHOWN ON PLANS. HT. AFF a NORMAL AND EMERGENCY LIGHTING OUTSIDE THE TENANT WATTS VA HARD LID F4 /F4EM SPACE IS THE RESPONSIBILITY OF THE LANDLORD. 2, SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION STOCK ROOM CEILING 120 34 AND QUANTITY OF LIGHTING FIXTURES. 172] ALL LIGHTING NOT CIRCUITED IS EXISTING TO REMAIN. 3, EMERGENCY AND EXIT LIGHTS SHALL BE INSTALLED AND CIRCUITED MOUNTED. PER THE LATEST NATIONAL ELECTRICAL CODE AND ALL LOCAL CODES. ❑3 RECONNECT LIGHTING TO EXISTING CIRCUIT AND CONTROLS. CSWG4 ALL EMERGENCY AND EXIT FIXTURES SHALL BE DUAL VOLTAGE BATTERY PACK TO (120/277 VOLT INPUT) WITH BATTERY BACKUP. FLUORESCENT STRIP U ® EMERGENCY LIGHTS do EXIT SIGNS SHALL BE PROVIDED WITH 90 4. CONTRACTOR IS RESPONSIBLE FOR ALL REFLECTED CEILING PLAN MINUTE MINIMUM BATTERY PACK AND SHALL BE CONNECTED TO THE NOTES ON ARCHITECTURAL DRAWINGS NEAREST NORMAL LIGHTING CIRCUIT SERVING THE AREA do MUST BE TOTAL OUTPUT. CIRCUITED AHEAD OF ANY LOCAL SWITCHING. 5. ALL EQUIPMENT TO BE U.L. LISTED OR EQUIVALENT. HAVE 90 MIN, BATTERY PACK) NIGHT LIGHTS SHALL BE PROVIDED WITH A CONTINUOUS OR 6. ALL LOW VOLTAGE WIRING MUST BE RUN IN CONDUIT CONCEALED IN COLUMBIA 2x 32W T8 CONSTANT HOT LINE do SHALL BE WIRED AHEAD OF ANY LOCAL STOCK ROOM CEILING WALLS. PLENUM RATED WIRING MAY BE RUN CONCEALED ABOVE 63 SWITCH. OR HUNG CEILING WHEN ALLOWED BY THE LOCAL AHJ. CS8- 132 - EUADVCEN/ F32T8/TL830ALTO MOUNTED 0 z © RELOCATE EXISTING LIGHTING CONTROL TIMECLOCKS AND 7. ALL EXPOSED CONDUIT MUST BE RUN STRAIGHT AND CSWG4 PHILLIPS CONTACTORS. CONTRACTOR TO EXTEND AND RECONNECT ALL PARALLEL /PERPENDICULAR TO STRUCTURE. RUN CONDUIT ADJACENT WIRING AND CONDUIT. MAINTAIN EXISTING CONTACTOR TO EXISTING STRUCTURE OR ROOF DECK WHERE POSSIBLE. FLUORESCENT STRIP CONFIGURATION AND PROGRAMMING. 8. REVIEW ANY QUESTIONS REGARDING INSTALLATION WITH LULULEMON �7 RELOCATE EXISTING MASTER LIGHTING SWITCHBANK. EXTEND PROJECT MANAGER. WITH WIRE GUARDS AND RECONNECT ALL EXISTING WIRING AND CONDUIT. n MAINTAIN EXISTING CONTROL CONFIGURATION. 9. ALL LIGHTS WITH A (R) ARE TO BE RELOCATED TO THE LOCATION SHOWN. CONTRACTOR TO VERIFY ALL RELOCATED LIGHTS ARE IN 120 ® SCOPE OF WORK BOUNDARY. HARD LID GOOD WORKING CONDITION, REPLACE ANY LIGHT FIXTURES NOT IN BEST 3.2W RED - < J LL. GOOD WORKING CONDITION AND TO REPLACE ALL LAMPS. '� W FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC, THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT, CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. NOTE: INFORMATION ON THIS SHEET PERTAINING TO THE EXISTING ELECTRICAL SYSTEM IS BASED ON RECORD DRAWINGS AND SITE INFORMATION AVAILABLE AT THE TIME OF DESIGN. FIELD VERIFY ALL EXISTING CONDITIONS AND NOTIFY ARCHITECT AND ENGINEER IMMEDIATELY IF ANY DISCREPANCIES ARE FOUND. SCHEDULES ARE FOR REFERENCE ONLY. REFER TO ARCHITECTURAL SHEET Al 20 FOR OFFICIAL SCHEDULES. LIGHTING FIXTURE SCHEDULE INSTALL NAME is SYMBOL FIXTURE LAMP HT. AFF INSTALL DIRECTIONS/ NOTES VOLTAGE WATTS VA HARD LID F4 /F4EM COLUMBIA 1x 32W T8 9' -6" STOCK ROOM CEILING 120 34 36 OR HUNG CS4- 132 - EUADVCEN/ F32Ti /TLB30ALTO MOUNTED. CSWG4 PHILLIPS BATTERY PACK TO FLUORESCENT STRIP U PROVIDE 1350 LUMENS WITH WIRE GUARDS (F4EM TO W TOTAL OUTPUT. HAVE 90 MIN, BATTERY PACK) HARD LID FE COLUMBIA 2x 32W T8 12' -0" STOCK ROOM CEILING 120 63 64 OR HUNG CS8- 132 - EUADVCEN/ F32T8/TL830ALTO MOUNTED 0 z CSWG4 PHILLIPS D FLUORESCENT STRIP LIC NSE # 61181 WITH WIRE GUARDS n or_,, 120 3.2/3.8 3.2/3.8 HARD LID EX2 BEST 3.2W RED - < J LL. '� W OR HUNG EZXTEU2RWEM 3.8W Q Z {C � i- .,_j a- BEST EXIT SIGN GREEN 0 z 0 z W/ BATTERY BACK -UP Ld aU IY (5 HARD LID EX3 LIGHTALARMS 10W HALOGEN 13' -0" MAX. CEILING OR WALL 120 20 20 OR WALL ® (CEILING) CA- 3 -3-LH7 O n _U oy- MOUNTED. _1 U MOUNTED CAVALIER II (CA -2) EACH LAMP TO PROVIDE Ld 41L_I:�,(WALL) 117 LUMEN OUTPUT. (R) nF8 i F4EM �R) IUI i 4 EX2 � ( 33 VAM u Wee .r.. J _ — . ,.j, r . r u ._ V - F .......... . I _ I = 'Eli L-------------------- 2 1 LLGL.I RIL.HL L SCALE: 3/16 " =1' -0" RM 0a N v, E ; , c I I I ' r I 3 .._._. ... .............................................. I _ -I UFO ...... _._ K I L LL 11 t I _.. _ . ..___. V V Vr V V V V W •IYVf i,V9 t 9 • V• • W W • • off v v u 0 W Y • 9 • W • • 9 Y r0 afW 9 • • • • W �YY • r•a ••• a � v v W t t •9• W 0 r W a r• r• u u r • • • • r Y r • t t t • W Y V • W Wei• • eve •at •aa• 009.9 rt9 9.99 •tot a • . • • • • • • • • 000• • 0!009 r •09 • *aa• t ..... „ �_... twpp to if E DAC}t CaN DEPARTMENT PIr')C. PrRMIT FIRE SUQ RESStOi�� _ FIREALARM� WATER MAIN EX7: DATE'S HENDERSON ENGINEERS= 8325 LENEXA DRIVE LENEXA, KS 16214 TEL 913 742 5000 FAX 913 742 5001 www.hei- eng.Eem 1250000!!9 FL. CEF11YEDIRM11110111111110 All 406 ClJ , YMAA�' < o T m El r z 0 E U W Ld F- 0 z Sam D HIM KE�"� LIC NSE # 61181 V) n or_,, U I� < J LL. '� W Q Z {C � i- .,_j a- z 0 z 0 z Ld aU IY (5 LLJ J Ld J z In O n _U oy- _1 U 0 Ld J W ISSUE FOR DD -LLL XX- -XX -XX ISSUE FOR DD -LLD XX -XX -XX ISSUE FOR CD -LLL XX -XX -XX ISSUE FOR CD -LLD XX -XX -XX ISSUE FOR PERMIT 09 -12 -12 ISSUE FOR SID XX -XX -XX Scale: Date: 06/12/12 Drawn ANS Ch•ck•A By: D M E Job um er: 17991 Drawing: 120