12-742-011ELECTRICAL RESPONSIBILITY SCHEDULE
I F6 T I
Z
F=
w
FURNISHED BY
INSTALLED BY
REMARKS
0
p
z
W
0
O
v
( F—
z
�°
cn
o
p
0
O
J
p
W
Z
0
O
F
0
W
Z W
< �—
UJ 0
cn
�
W
d
MAIN SERVICE DISCONNECT ON EXTERIOR
OF BUILDING
.
(EXISTING)
(EXISTING)
240D/120V
240D/120V
240D/120V
30,4W
304W
I
I
30,4W
FIELD VERIFY PRIOR TO BID
PANEL BOARD CONDUIT TO SPACE
•
•
i i ervice oin
•
5
a e secon ary o e u alit trap V center a e Delta —
phase an phase
•
Motor Contribution
FIELD VERIFY PRIOR TO BID
PANELBOARD FEEDERS TO SPACE
•
a
•
•
FIELD VERIFY PRIOR TO BID
METER REQUIREMENTS
•
FIELD VERIFY PRIOR TO BID
LIGHT FIXTURES AND LAMPS
c.�
•
OUTLETS AND SWITCHES
•
•
GENERAL CONDUIT do WIRING
•
•
TELEPHONE CONDUIT W/ PULL WIRE
•
Uj
0
•
TELEPHONE CABLING
•
•
TELEPHONE EQUIPMENT
0
•
DATA CONDUIT
•
•
DATA CABLING
•
•
VIDEO /TV CONDUIT
•
•
VIDEO /TV • CABLING
•
•
TEMPORARY UTILITY CHARGES
•
•
TENANT ELECTRICAL PANELS
•
TENANT ELECTRICAL TRANSFORMER
N/A
TENANT FIRE ALARM SYSTEM
•
DEFERRED SUBMITTAL BY G.C.
SENSORMATIC
•
•
FURNISHED AND INSTALLED
BY EAS
SENSORMATIC CORE DRILL /TRENCH AND CONDUIT
e
LIGHTING CONTROL SYSTEM COMPONENTS
a
•
w
s
6
0
D
EXISTING CONDUCTORS AND CONDUIT MAY BE REUSED IF THEY ARE
IN GOOD CONDITION AND MEET OR EXCEED THE SIZES AS LISTED ON
THE RISER DIAGRAM.
(4)350KCMIL, (1) #2G, 3YC
(EXISTING)
EXISTING WEATHERHEAD
EXISITNG OVERHEAD CONNECTION TO
UTILITY POLE — MOUNTED TRANSFORMERS
EXTERIOR LANDLORD
F1 � �~
(4)350KCMIL, 3"C rEXISTING WIREWAY
(EXISTING) I I
EXISTING TENANT METER --� V I I I % I F3
LANDLORD I TENANT
F2
I F6 T I
f F4
400AS
200A
150AS
3P
I 3P
3P
300AF
ENCLOSED
ENCLOSED
DISC SWITCH
C.B.
C. B.
(EXISTING)
(EXISTING)
(EXISTING)
240D/120V
240D/120V
240D/120V
30,4W
304W
I
I
30,4W
EXISTING SERVICE GROUNDS I
FIELD VERIFY EXISTING AVAILABLE
FAULT CURRENT AT UTILITY
TRANSFORMER SECONDARIES AND ELECTRICA
NOTIFY ARCHITECT AND ENGINEER
IMMEDIATELY IF VALUE EXCEEDS NOT TO SCALE
65,000 AMPS.
DI
RELABEL EXISTING PANELS AS INDICATED AND PROVIDE WITH NEW
CIRCUIT DIRECTORIES.
�(4) #3/0, (1) #4G, 2 "C
(EXISTING)
I
(4) #1/0, (1) #6G, 2 "C
(EXISTING)
PANEL "AC"
(EXISTING)
(ETR) PANEL "L1„
(EXISTING)
LIGHTING
CONTROL
PANEL
(4)#1/0, (1) #6G, 2 "C
(EXISTING)
(4) #3/0, (1) #4G, 2 "C
(EXISTING)
urcutt and vain • un uicwan•ns
:w are far s• cu • fan 1rurP•sao only an s e n u or s•ntn r •offs nor n — • r s al n y Engineer a any • «n on at r•au
The following onloulellone are bassi an the 'Point -by- Feint" mother where:
ISC (2) = ISC(1) x M(1) M= 1/(1 +f) Fesreh(39) a 1,732 x L x Iee XFMR: f (30) = IS(am)-
ISC (1) = short circuit current at fault print 1 C x E 100.000 x KVA Vs
ISC (2) = short circuit current at fault point 2 Feared (I IN)- x —xJae XFMR: f (1/)a IIK�Ix Ve, Y fLI
C x E 100.000 x KVA
a
Ip Primary short circuit current
Vp = Primary voltage
IS= Secondary short circuit current
Vs— Secon•lary voltage
;ircuit I Conductor conauctor
Load Resistance Reactance Impealence,
A R X Z/ 0
or
PANEL "L2"
(EXISTING)
F8
FLOOR
4) #3, (1) #8G, 1 -1/4 "C
EXISTING)
prop
•••
L = Length of circuit E = Line to line volts
•
oboe•
sr•
C = "C" Factor from Dussman talole where "C" = 1
/ impedance per linear foot
Fader 7Vp" w
rr
r
w r
NM — Non Magnetic Conduit,
M — Magnetic Conduit, FB — Feeder Busway, PE — Plug --in Rusway, TX — Transformer
• •
Fault
Source
Source Feeder
L —L Circuit Load
Point Bus/Feeder Phase
(Fault
Isc Conduit Material Conductor
Busway Volts Length Power
F Descri tion
Point)
am s T e CU or AL Wire Bus Size_ .C' value
C value E L Factor('
•
i i ervice oin
w •
5
a e secon ary o e u alit trap V center a e Delta —
phase an phase
i
Motor Contribution
w r r
a connected fufi oad mo ar am IDS me udes tom )ressorsL on a system
a
Ip Primary short circuit current
Vp = Primary voltage
IS= Secondary short circuit current
Vs— Secon•lary voltage
;ircuit I Conductor conauctor
Load Resistance Reactance Impealence,
A R X Z/ 0
or
PANEL "L2"
(EXISTING)
F8
FLOOR
4) #3, (1) #8G, 1 -1/4 "C
EXISTING)
prop
•••
e
•
oboe•
sr•
♦
• •
••
rr
r
w r
•wr
r •
• •
•
•
r V
y
w r
V
r
•
w r V t+ r
• r
w •
i
•
•
w •
•V•
GeV V
W
i
a.**
w r r
RISER DIAGRAM GENERAL NGTE�- r •'; • •o •wW
V w w ♦ i ♦ r V
1. HVAC CIRCUIT BREAKERS TO BE "HACR" TYPE 1NY-IEFE REQt.REIJAY •:• Ypw
EQUIPMENT NAMEPLATE PER NEC.
2. FIELD VERIFY EXACT KAIC RATING OF LANDLCRO"S DISYKM1T1ON'4E0JPMF.-NT.••
FURNISH AND INSTALL TENANTS ELECTRICAL SYSTEM TO ,MATCH, ;
4 r ♦ r r r •
***,1 • ••r ♦V • ♦rN r sr4♦
3. BALANCE ALL PANELBOARDS AND ELECTRICAL EQUIPMENT UNDER LOAD
CONDITIONS TO +/— 10% BETWEEN PHASES; A /B, B /C, A/C REGARDLESS OF
CIRCUITING INDICATED.
4. PROPER CLEARANCE MUST BE MAINTAINED ABOUT ELECTRICAL EQUIPMENT PER
NEC. FIELD VERIFY EXACT MOUNTING SPACE AVAILABLE IN ELECTRICAL
ROOM /AREA PRIOR TO INSTALLATION OF ELECTRICAL EQUIPMENT.
5, MAKE ALL FINAL ELECTRICAL CONNECTIONS FOR A COMPLETE ELECTRICAL
DISTRIBUTION SYSTEM,
6. TENANT'S NAME AND SPACE SHALL BE ENGRAVED ON A BAKELITE PLATE WITH
1" HIGH LETTERS. SCREW FASTEN TO THE METER SOCKET AND DISCONNECT
SWITCH AT THE SERVICE DISTRIBUTION POINT.
7. ALL CONNECTIONS TO LANDLORD'S SERVICE EQUIPMENT SHALL BE AS
DIRECTED BY LANDLORD'S SITE REPRESENTATIVE. PROVIDE ALL TERMINATION
EXPENSES.
8. SYSTEM SHALL BE GROUNDED TO THE MAIN BUILDING'S GROUNDING SYSTEM.
9. INSTALL ALL EQUIPMENT TO MEET SEISMIC CRITERIA AT THE SITE. REFER TO
ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION.
10. ALL EQUIPMENT TO BE U.L. LISTED OR EQUIVALENT.
v2.08.0
VOLTAGE DROP (311}
XVD- ((R x eee(emoee(Ff)) + X x sin (arseee(Ff))) x L/% x I x 1.73) / E
VOLTAGE DROP (10
XVD= ((R x eee(anee•('f)) + X x sln(arsa•e(Ff))) x 2 x L,/f x 1) / E
%VD CUM= Cumulative Voltage Drop from Fault Point 1 to Fault Point #
R= resistance in ohms per LF
X= reactances in ohms per LF
of FAULT VOLTAGE TOTAL I Fault
Degree CURRENT DROP V.D. Point
kVA Rise Z V sec f M Isc %VD 7.VD CUM I (F#
HENDERSON
ENGINEERS=
1325 LENEXA DRIVE
LENEXA, KS 66214
TEL 913 742 5000 FAx 413 742 5001
www.h•i- eng.com
12500009!9
FL. CEFffEUA1'i1111XA1WIE1 AH 7606
lNR150'1//A// 3
F
v� a`
erg
rrrr�y�y�
C5 �
e�
Z
0
a
c.�
W
Uj
0
0
Z
# "96
STXM OF
EE
V)
0
Cn
O n
U
(� LL
`—/
c--
z <n
�- U z
z F-- Q
CD w [--
z
C) �-
z <0 °
< a
0U
09 °
W w
V)
z
V)
< � It
O
U n
_j U L
U
W
W
ISSUE FOR DD —LLL XX —XX —XX
ISSUE FOR DD —LLD XX —XX —XX
ISSUE FOR CD —L I L XX —XX —XX
ISSUE FOR CD —LLD XX —XX —XX
ISSUE FOR PERMIT 041 -12 -12
ISSUE FOR BID XX —XX —XX
Late: o s 1 2/12
Drawn y: ANS
Chocked By: D M E
Job Number 17991
IDrawing:
E012