10-1088R-004V
w
_
z
6
Y
PLUMBING SYMBOLS
NOTE: THIS IS A MASTER LEGEND AND NOT ALL SYMBOLS, ABBREVIATIONS, ETC. ARE
NECESSARILY USED ON THE DRAWINGS.
ANNOTATION
I'll
r
PIPING
u• o
PLUMBING PLAN NOTE CALLOUT
c3
-
DOMESTIC COLD WATER (CW)
v CO (yj o LL
"C
V/ ■ r"j w
SCW
SOFTENED COLD WATER (SM
PLUMBING EQUIPMENT DESIGNATION. (CONTRACTOR FURNISHED AND
"_0� �.
ofi
INSTALLED). REFER TO PLUMBING FIXTURE OR EQUIPMENT SCHEDULES
__
DOMESTIC HOT WATER (HW)
- --
DOMESTIC HOT WATER RECIRC. (HWR)
EQUIPMENT DESIGNATION (OWNER FURNISHED, CONTRACTOR
O
INSTALLED)
140*
140* DOMESTIC HOT WATER (140')
T
TRAP PRIMER LINE(T)
CU MECHANICAL EQUIPMENT DESIGNATION
(CONTRACTOR FURNISHED AND
d
1 INSTALLED UNLESS NOTED OTHERWISE)
i
S
SOIL PIPING - ABOVE FLOOR (S)
--S--
SOIL PIPING - BELOW FLOOR (S)
CONNECTION POINT OF NEW WORKTO EXISTING
DETAIL REFERENCE UPPER NUMBER INDICATES
DETAIL NUMBER LOWER
W
WASTE PIPING -ABOVE FLOOR (W)
M1 NUMBER INDICATES SHEET NUMBER
--W--
WASTE PIPING - BELOW FLOOR (W)
1 SECTION CUT DESIGNATION
f�
GW
--- -- -GW- - -
GREASE WASTE- ABOVE FLOOR (GW)
GREASE WASTE - BELOW FLOOR (GW)
M1
ST
STORM DRAIN - ABOVE FLOOR (ST}
STANDARD MOUNTING HEIGHTS
- — — -ST- — — -
STORM DRAIN - BELOW FLOOR (ST)
OST
OVERFLOW STORM DRAIN - ABOVE FLOOR (OST)
PLUMBING
(AFF, AFG, UNLESS NOTED OTHERWISE)
- - -VBG- - -
VENT BELOW GRADE (VBG)
REFER TO THE ARCHITECTURAL DRAWINGS FOR PLUMBING FIXTURE MOUNTING HEIGHTS. UNO, INSTALL
-VBF- — --
VENT BELOW FLOOR (VBF)
PLUMBING FIXTURES WITH THE MOUNTING HEIGHTS AS LISTED BELOW WITH FINAL APPROVAL BY THE
ID
INDIRECT DRAIN (ID)
ARCHITECT.
CDH
CONDENSATE DRAIN - HIGH EFFICIENCY RTU (CDH)
ADA ACCESSIBLE DRINKING FOUNTAIN
17' FLOOR TO RIM
CD
CONDENSATE DRAIN (CD)
ADA ACCESSIBLE LAVATORIES
34' FLOOR TO RIM
-ACD-
AUXILIARY CONDENSATE DRAIN (ACID)
ADA ACCESSIBLE SHOWER VALVES
38' MINIMUM TO 48' MAXIMUM
SPD
SUMP OR SEWAGE PUMP DISCHARGE(SPD)
2 2
FLOOR TO CENTERLINE
G
NATURAL GAS (G)
ADA ACCESSIBLE TUB VALVES
CENTER BETWEEN GRAB BAR
- - - -G- - - -
NATURAL GAS ON ROOF (G)
AND TUB RIM
MPG
MEDIUM PRESSURE NATURAL GAS (MPG)
ADA ACCESSIBLE URINALS
17' FLOOR TO RIM
.- - -MPG - - .--
MEDIUM PRESSURE NATURAL GAS ON ROOF (MPG)
ADA ACCESSIBLE WATER CLOSET
17' TO 19' FLOOR TO
NPW
NON POTABLE WATER (NPW)
TOP OF SEAT
LPG
LIQUIFIED PETROLEUM GAS (LPG)
ADA ACCESSIBLE WATER COOLER
35• FLOOR TO RIM
WS
WATER SERVICE (WS)
ADULT STANDARD DRINKING FOUNTAIN
40• FLOOR TO RIM
as
FP
FIRE PROTECTION (FP)
ADULT STANDARD WATER COOLER
30' FLOOR TO RIM
PD
CONDENSATE PUMP DISCHARGE (PD)
CHILD STANDARD DRINKING FOUNTAIN
30' FLOOR TO RIM
zzzZ
— — — — —
EXISTING PIPING TO BE REMOVED
CHILD STANDARD WATER COOLER
14' FLOOR TO RIM
�
¢4�
EXISTING PIPING TO REMAIN
CHILD URINAL
14' FLOOR TO RIM
b
CLINIC SERVICESINKS
30' FLOOR TO RIM
V
VENT PIPING (V)
JANITOR'S SINK FAUCET FITTINGS
42' FLOOR TO CENTERLINE
AW
ACID WASTE - ABOVE FLOOR (AW)
HOSE BIBBS
36" AFF TO CENTERLINE
- - - -AW- - - -
ACID WASTE- BELOW FLOOR (AW)
ICE MAKER OUTLET BOXES
24" FLOOR TO CENTER OF BOX
AV
ACID VENT (AV)
LAVATORY OR SINK
31 • FLOOR TO RIM
CA
COMPRESSED AIR (CA)
NON FREEZE HYDRANT
18' AFG TO CENTERLINE
—Al—
MEDICAL AIR INTAKE (AI)
SHOWER HEADS
6e-O' MEN & 5'-e WOMEN
MA
MEDICAL AIR (MA)
,-�
FLOOR TO CENTERLINE
MV
MEDICAL VACUUM (MV)
SHOWER VALVES
48' MEN & 42' WOMEN FLOOR
—VE—
MEDICAL VACUUM EXHAUST(VE)
0
TO CENTERLINE
EV
EVACUATION (EV)
STANDARD URINALS
22' FLOOR TO RIM
CO
CARBON DIOXIDE (CO)
SURGEON'S SCRUB -UP SINKS
35' FLOOR TO FRONT RIM
N
NITROGEN (N)
TUB VALVES
32' FLOOR TO CENTELINE
N
N
N
N
0
OXYGEN (O}
WASHING MACHINE OUTLET BOXES
42' FLOOR TO RIM
NO
NITROUS OXIDE (NO}
WATER CLOSET
15' FLOOR TO RIM
o
•-- 0
OXYGEN OUTLET
ABBREVIATIONS
0
NITROUS OXIDE OUTLET
AFF ABOVE FINISHED FLOOR
MH
MANHOLE
�.♦
MEDICAL AIR OUTLET
AFG ABOVE FINISHED GRADE
MIN
MINIMUM
AHU AIR HANDLING UNIT
N/C
NORMALLYCLOSED
—�
NITROGEN OUTLET
BFF BELOW FINISHED FLOOR
N/0
NORMALLY OPEN
- -4
MEDICAL VACUUM INLET
BFG BELOW FINISHED GRADE
ORD
OVERFLOW ROOF DRAIN
®
SQUARE FLOOR DRAIN (FS), SIZE &TYPE
BOP BOTTOM OF PIPE
PDI
PLUMBING DRAINAGE INSTITUTE
BOS BOTTOM OF STRUCTURE
PVC
POLYVINYL CHLORIDE
ROUND FLOOR DRAIN(FID),SIZE &TYPE
BTU BRITISH THERMAL UNIT
PRY
PRESSURE REDUCING VALVE
1
ROOF DRAIN (RD), SIZE & TYPE
CPVC CHLORINATED POLYVINYL CHLORIDE
RD
ROOF DRAIN
.91
BALL VALVE
DN DOWN
RPM
REVOLUTIONS PER MINUTE
DFU DRAINAGE FIXTURE UNIT
RTU
ROOFTOP UNIT
CONTROL VALVE
DS DOWNSPOUT
SF
SQUARE FEET, SUPPLY FAN
SHUTOFF VALVE
CPO
ETR EXISTING TO REMAIN
SP
SUMP PUMP
EWC ELECTRICWATER COOLER
SS
STAINLESS STEEL. SANITARY SEWER,
CHECK VALVE
FD FLOOR DRAIN
SOIL
STACK
v
BALANCING VALVE WITH PRESSURE PORTS
FFA FROM FLOOR ABOVE
TRH
TOTAL DYNAMIC HEAD
19`
WATER METER
FFB FROM FLOOR BELOW
TFA
TO FLOOR ABOVE
FF FINISHED FLOOR
TFB
TO FLOOR BELOW
STRAINER
FL FLOW LINE
TYP
TYPICAL
STRAINER WITH BLOWOFF
FLA FULL LOAD AMPS
UL
UNDERWRITERS LABORATORIES,
RELIEF /SAFETY VALVE
FLR FLOOR
INC
GPM GALLONS PER MINUTE
LINO
UNLESS NOTED OTHERWISE
SOLENOID VALVE
HD HEAD, HUB DRAIN
UPS
UNINTERRUPTIBLE POWER SUPPLY
PRESSURE REDUCING VALVE
at
IE INVERT ELEVATION
V
VOLT(S)
GAS PRESSURE REGULATOR
IN WC INCHES OF WATER COLUMN
VCP
VITRIFIED CLAY PIPE
JB JUNCTION BOX
VS
VENT STACK
THERMOSTATIC MIXING VALVE
J-BOX JUNCTION BOX
VTR
VENT THROUGH ROOF
PA
PIPE ANCHOR
WW KILOWATT
W/
WITH
EJ
IXPANSION JOINT
MAU MAKEUP AIR UNIT
W/0
WITHOUT
MAX MAXIMUM
WC
WATER COLUMN
BACKFLOW PREVENTER
MBH 1000 BTU PER HOUR
WS
WASTE STACK
•
PRESSURE GAUGE
WSFU WATER SUPPLY FIXTURE UNIT
THERMOMETER
UNION
FLANGE CONNECTION
HOSE BIBB (HB)
---}�
NONFREEZE WALL HYDRANT (NW)
MANUAL/ AUTOMATIC AIR VENTOR VACUUM
RELIEF VALVE
CLEANOUT
CAP
ID
WALL CLEANOUT (WCO)
A
FLOOR CLEANOUT (FCO)
�O
EXTERIOR CLEANOUT(ECO)
10
ELBOW UP
- -�Ei
ELBOW DOWN
TEE UP
TEE DOWN
lei
- -19
ELBOW UP WITH SHUT -OFF VALVE (SOV)
—Q
ELBOW DOWN WITH SHUT -OFFVALVE(SOV)
TEE UP WITH SHUT -OFF VALVE(SOV)
TEE DOWN WITH SHUT -OFF VALVE (SQV)
-
* .A"
WATER HAMMER ARRESTER (WHA)
WITH PDI SIZES, (A, B, C, D. & E)
RECIRCULATION PUMP
flf,
P -TRAP
GAS COCK
TRAP PRIMER
TRAP PRIMER WITH DISTRIBUTION UNIT
1/2-CW &
1 /2 "HW DN
►� I
(E)4
M.EN'S
RESTROOM
2 tNLAKk7tU
SCALE: 1/4 " =1
I
e
P
,l
ti
GENERAL NOTES:
1. DRAWINGS ARE DIAGRAMMATIC ONLY AND REPRES7,o4T TH` �EKERAL SCOPE - VF
THE WORK. REVIEW THE GENERAL NOTES, SPECIFICATIONS AND PLANS FOR
ADDITIONAL REQUIREMENTS THAT MAY NOT BE SPECIFICALLY_ CALLED OUT IN
THIS PORTION OF THE CONSTRUCTION DOCUMENTS. NOTIFY THE-OWNER'S T -
CONSTRUCTION MANAGER OF ANY CONFLICTS OR DISCREPANCIES �'RI012 TO Q
SUBMISSION OF BID. - - ---
2. FURNISH A CONSTRUCTION RECORD SET OF "AS— BUILT" DOCUMENTS TO THE
OWNER'S CONSTRUCTION MANAGER REFLECTING ANT ✓ARIANCES- OF IN,a AI LED a -
PIPING LOCATIONS OR EQUIPMENT CONTRARY TO THE CONSTRUCTION -
DOCUMENTS PREPARED BY THE ENGINEER —OF— RECORD- AFTE:(2_ FINAL
INSPECTION OF INSTALLED PLUMBING SYSTEMS.
3. FURNISH TO THE OWNER'S CONSTRUCTION MANAGER A COPY OF INSPECTION
REPORTS AND APPROVAL CERTIFICATES FROM LOCAL AND STATE INSPECTIONS.
4. INSTALLATION SHALL COMPLY WITH LEGALLY CONSTITUTED CODES AND THE
REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION AND ALSO MEET ALL
REQUIREMENTS OF THE LANDLORD.
5. PLANS AND SPECIFICATIONS GOVERN WHERE THEY EXCEED CODE
REQUIREMENTS.
6. VERIFY LOCATION AND DEPTH OF UTILITIES AT POINTS OF CONNECTION BEFORE
START OF PROJECT.
7. REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATION AND MOUNTING
HEIGHTS OF PLUMBING FIXTURES.
8. DO NOT SCALE FLOOR PLANS FOR EXACT HORIZONTAL LOCATION OF PIPE
ROUTING.
9. VALVES SHALL BE LINE SIZE UNLESS OTHERWISE NOTED.
10. PIPING IN FINISHED AREAS SHALL BE ROUTED CONCEALED; EXPOSED PIPING,
WHERE NECESSARY, SHALL BE ROUTED AS HIGH AS POSSIBLE AND TIGHT TO
WALLS.
11. COORDINATE ALL WORK WITH OTHER TRADES AND CONTRACTORS.
12. COORDINATE PIPING INSTALLATION WITH STRUCTURAL GRADE BEAMS, FOOTINGS,
COLUMN PIERS, ETC. SLEEVE PIPING THROUGH GRADE BEAMS, FOOTING, ETC.
WHERE REQUIRED AND AS NOTED ON PLANS. COORDINATE SLEEVE
INSTALLATIONS WITH THE ARCHITECT, STRUCTURAL ENGINEER, STRUCTURAL
CONTRACTOR AND GENERAL CONTRACTOR BEFORE CONCRETE IS INSTALLED.
13. CLEAN FAUCET AERATORS AND PIPE STRAINERS PRIOR TO TURNING BUILDING
OVER TO THE OWNER.
14. PROVIDE TRAP PRIMERS WHERE REQUIRED BY LOCAL AUTHORITIES.
15. COORDINATE PIPE ROUTING AWAY FROM ELECTRICAL PANELS. DO NOT ROUTE
PIPING OVER ELECTRICAL PANELS.
16. PAINT ALL EXPOSED GAS AND WATER PIPING USING RUST INHIBITOR PAINT.
PAINT AND COLOR SHALL BE COORDINATED WITH THE ARCHITECT AND / OR
OWNER.
17. COORDINATE ALL ROOF PENETRATIONS WITH OTHER TRADES. MAINTAIN 10'
MINIMUM CLEARANCE FROM ALL AIR INTAKES. MAINTAIN 2' CLEARANCE FROM
ALL OTHER EQUIPMENT.
18. INSULATE PIPING ROUTED IN EXTERIOR BUILDING WALLS WITH MINIMUM 2" BAIT
INSULATION TO PREVENT FREEZING.
19. WATER HAMMER ARRESTORS SHALL BE SIZE "A" UNLESS NOTED OTHERWISE.
20. GENERAL CONTRACTOR SHALL ROD AND SCOPE WASTE LINE TO LANDLORD'S
MAIN PRIOR TO TURNOVER.
21. HARD 90 DEGREE TURNS WILL NOT BE ALLOWED ON WASTE LINES. TURNS MUST
BE SWEEPING.
,PLAN NOTES:
`./ CONNECT TO LANDLORD PROVIDED EXISTING 4" SANITARY PIPE. FIELD VERIFY
INVERT, SIZE, EXACT LOCATION AND DIRECTION OF FLOW PRIOR TO SUBMITTING
BID.
CONNECT TO LANDLORD PROVIDED EXISTING 2 -1/2" VENT LINE. FIELD VERIFY
EXACT LOCATION AND SIZE PRIOR TO SUBMITTING BID.
CONNECT NEW CW LINE TO EXISTING 1 "CW SUPPLY. SEE DRAWINGS FOR PIPE
CONNECTION SIZE(S).
DO NOT INSTALL PLUMBING PIPING OVER ELECTRICAL PANELS OR EQUIPMENT.
PROVIDE CARTRIDGE FILTER UNDER WATER FEATURE. PROVIDE BACK FLOW
PROTECTION PER LOCAL AUTHORITIES REQUIREMENTS ON WATER SUPPLY LINE.
6 INSTALL WATER HAMMER ARRESTORS IN THE DOMESTIC COLD AND HOT WATER
PIPING AS SHOWN ON THE WATER RISER DIAGRAM. WATER HAMMER ARRESTORS
TO BE LOCATED IN AN ACCESSIBLE LOCATION. UNITS MANUFACTURED BY SIOUX
AND PRECISION PLUMBING PRODUCTS ARE ACCEPTABLE.
(D FOR EXACT FLOOR DRAIN LOCATIONS REFER TO ARCHITECTS FINISH PLAN.
PATCH AND REPAIR SLAB TO MATCH SURROUNDING FINISH.
,9 ROUTE INDIRECT DRAIN LINE TIGHT TO WALL, TURN DOWN TO FUNNEL
FLOOR DRAIN.
FIELD VERIFY ALL CONDITIONS
DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO
BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT
SHALL INCLUDE :i' AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO
EXISTING • D i
THE • i• SHALL CONTACT A. ENGINEER OR OWNER PRIOR TO BIDDING
FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL
BIDDING COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR
OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST.
i •` S SHALL HAVE A WORKING KNOWLEDGE OF i ACODES AND
WITHSTANDING. ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN
STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT
i ' A •. ARCHITECT, OR OWNER OF
APPARENT DISCREPANCIES • •! S 1 !
NOTE:
INFORMATION ON THIS SHEET PERTAINING TO THE EXISTING PLUMBING SYSTEM IS BASED ON RECORD
DRAWINGS AVAILABLE AT THE TIME OF DESIGN. FIELD VERIFY ALL EXISTING CONDITIONS AND NOTIFY
ARCHITECT AND ENGINEER IMMEDIATELY IF ANY DISCREPANCIES ARE FOUND.
HENDERSON
f"ENGINEERSK
8325 LENEXA DRIVE
LEND(k KS 66214
Ta 913 742 5000 FAx 913 742 5001
WWWj eil -engA6 e
1050001129
FL CORPORATE NUMBER EB 7606
EXPIRES 2/28/11
HDOO N
�®
I'll
r
°te=
u• o
°t E
c3
a,
c❑.
v CO (yj o LL
"C
V/ ■ r"j w
t/a E�j
ui
v iz C5
"_0� �.
ofi
z
O
d
i
•
f�
N
W
00
yJ
N
2 2
¢
Ce
J
v
to
%D
as
co
zzzZ
Z.
�
¢4�
°aECC
b
=
uiLu
=*
ri����
ft
J
J
J
J
U
E
E
a
a
W
an
m
m
Co
0
0
.-,
r,
.-�
,-�
.-,
.-,
'1
r,
0
0
0
0
0
0
0
0
0
0
N
N
N
N
N
N
N
N
N
N
o
.-�
N
N
e-1
e-i
O
O
*�
O
�
O
O
o
N
0
N
0
tf1
tt?
1!
co
N
N
N
Zd
ea%-1
N
r
•
•
Limlum
a
indicated
°te=
10/14/10
z"
c3
Checked By:
HEI
Job Number.
16401
.ice.:
r
•
•
Limlum
a
" "' As
indicated
°te=
10/14/10
D-ra-w-W-W.
HEI
Checked By:
HEI
Job Number.
16401
i
•
" "' As
indicated
°te=
10/14/10
D-ra-w-W-W.
HEI
Checked By:
HEI
Job Number.
16401
CELEBRATING Drawing:
® ► /