Loading...
10-1088R-004V w _ z 6 Y PLUMBING SYMBOLS NOTE: THIS IS A MASTER LEGEND AND NOT ALL SYMBOLS, ABBREVIATIONS, ETC. ARE NECESSARILY USED ON THE DRAWINGS. ANNOTATION I'll r PIPING u• o PLUMBING PLAN NOTE CALLOUT c3 - DOMESTIC COLD WATER (CW) v CO (yj o LL "C V/ ■ r"j w SCW SOFTENED COLD WATER (SM PLUMBING EQUIPMENT DESIGNATION. (CONTRACTOR FURNISHED AND "_0� �. ofi INSTALLED). REFER TO PLUMBING FIXTURE OR EQUIPMENT SCHEDULES __ DOMESTIC HOT WATER (HW) - -- DOMESTIC HOT WATER RECIRC. (HWR) EQUIPMENT DESIGNATION (OWNER FURNISHED, CONTRACTOR O INSTALLED) 140* 140* DOMESTIC HOT WATER (140') T TRAP PRIMER LINE(T) CU MECHANICAL EQUIPMENT DESIGNATION (CONTRACTOR FURNISHED AND d 1 INSTALLED UNLESS NOTED OTHERWISE) i S SOIL PIPING - ABOVE FLOOR (S) --S-- SOIL PIPING - BELOW FLOOR (S) CONNECTION POINT OF NEW WORKTO EXISTING DETAIL REFERENCE UPPER NUMBER INDICATES DETAIL NUMBER LOWER W WASTE PIPING -ABOVE FLOOR (W) M1 NUMBER INDICATES SHEET NUMBER --W-- WASTE PIPING - BELOW FLOOR (W) 1 SECTION CUT DESIGNATION f� GW --- -- -GW- - - GREASE WASTE- ABOVE FLOOR (GW) GREASE WASTE - BELOW FLOOR (GW) M1 ST STORM DRAIN - ABOVE FLOOR (ST} STANDARD MOUNTING HEIGHTS - — — -ST- — — - STORM DRAIN - BELOW FLOOR (ST) OST OVERFLOW STORM DRAIN - ABOVE FLOOR (OST) PLUMBING (AFF, AFG, UNLESS NOTED OTHERWISE) - - -VBG- - - VENT BELOW GRADE (VBG) REFER TO THE ARCHITECTURAL DRAWINGS FOR PLUMBING FIXTURE MOUNTING HEIGHTS. UNO, INSTALL -VBF- — -- VENT BELOW FLOOR (VBF) PLUMBING FIXTURES WITH THE MOUNTING HEIGHTS AS LISTED BELOW WITH FINAL APPROVAL BY THE ID INDIRECT DRAIN (ID) ARCHITECT. CDH CONDENSATE DRAIN - HIGH EFFICIENCY RTU (CDH) ADA ACCESSIBLE DRINKING FOUNTAIN 17' FLOOR TO RIM CD CONDENSATE DRAIN (CD) ADA ACCESSIBLE LAVATORIES 34' FLOOR TO RIM -ACD- AUXILIARY CONDENSATE DRAIN (ACID) ADA ACCESSIBLE SHOWER VALVES 38' MINIMUM TO 48' MAXIMUM SPD SUMP OR SEWAGE PUMP DISCHARGE(SPD) 2 2 FLOOR TO CENTERLINE G NATURAL GAS (G) ADA ACCESSIBLE TUB VALVES CENTER BETWEEN GRAB BAR - - - -G- - - - NATURAL GAS ON ROOF (G) AND TUB RIM MPG MEDIUM PRESSURE NATURAL GAS (MPG) ADA ACCESSIBLE URINALS 17' FLOOR TO RIM .- - -MPG - - .-- MEDIUM PRESSURE NATURAL GAS ON ROOF (MPG) ADA ACCESSIBLE WATER CLOSET 17' TO 19' FLOOR TO NPW NON POTABLE WATER (NPW) TOP OF SEAT LPG LIQUIFIED PETROLEUM GAS (LPG) ADA ACCESSIBLE WATER COOLER 35• FLOOR TO RIM WS WATER SERVICE (WS) ADULT STANDARD DRINKING FOUNTAIN 40• FLOOR TO RIM as FP FIRE PROTECTION (FP) ADULT STANDARD WATER COOLER 30' FLOOR TO RIM PD CONDENSATE PUMP DISCHARGE (PD) CHILD STANDARD DRINKING FOUNTAIN 30' FLOOR TO RIM zzzZ — — — — — EXISTING PIPING TO BE REMOVED CHILD STANDARD WATER COOLER 14' FLOOR TO RIM � ¢4� EXISTING PIPING TO REMAIN CHILD URINAL 14' FLOOR TO RIM b CLINIC SERVICESINKS 30' FLOOR TO RIM V VENT PIPING (V) JANITOR'S SINK FAUCET FITTINGS 42' FLOOR TO CENTERLINE AW ACID WASTE - ABOVE FLOOR (AW) HOSE BIBBS 36" AFF TO CENTERLINE - - - -AW- - - - ACID WASTE- BELOW FLOOR (AW) ICE MAKER OUTLET BOXES 24" FLOOR TO CENTER OF BOX AV ACID VENT (AV) LAVATORY OR SINK 31 • FLOOR TO RIM CA COMPRESSED AIR (CA) NON FREEZE HYDRANT 18' AFG TO CENTERLINE —Al— MEDICAL AIR INTAKE (AI) SHOWER HEADS 6e-O' MEN & 5'-e WOMEN MA MEDICAL AIR (MA) ,-� FLOOR TO CENTERLINE MV MEDICAL VACUUM (MV) SHOWER VALVES 48' MEN & 42' WOMEN FLOOR —VE— MEDICAL VACUUM EXHAUST(VE) 0 TO CENTERLINE EV EVACUATION (EV) STANDARD URINALS 22' FLOOR TO RIM CO CARBON DIOXIDE (CO) SURGEON'S SCRUB -UP SINKS 35' FLOOR TO FRONT RIM N NITROGEN (N) TUB VALVES 32' FLOOR TO CENTELINE N N N N 0 OXYGEN (O} WASHING MACHINE OUTLET BOXES 42' FLOOR TO RIM NO NITROUS OXIDE (NO} WATER CLOSET 15' FLOOR TO RIM o •-- 0 OXYGEN OUTLET ABBREVIATIONS 0 NITROUS OXIDE OUTLET AFF ABOVE FINISHED FLOOR MH MANHOLE �.♦ MEDICAL AIR OUTLET AFG ABOVE FINISHED GRADE MIN MINIMUM AHU AIR HANDLING UNIT N/C NORMALLYCLOSED —� NITROGEN OUTLET BFF BELOW FINISHED FLOOR N/0 NORMALLY OPEN - -4 MEDICAL VACUUM INLET BFG BELOW FINISHED GRADE ORD OVERFLOW ROOF DRAIN ® SQUARE FLOOR DRAIN (FS), SIZE &TYPE BOP BOTTOM OF PIPE PDI PLUMBING DRAINAGE INSTITUTE BOS BOTTOM OF STRUCTURE PVC POLYVINYL CHLORIDE ROUND FLOOR DRAIN(FID),SIZE &TYPE BTU BRITISH THERMAL UNIT PRY PRESSURE REDUCING VALVE 1 ROOF DRAIN (RD), SIZE & TYPE CPVC CHLORINATED POLYVINYL CHLORIDE RD ROOF DRAIN .91 BALL VALVE DN DOWN RPM REVOLUTIONS PER MINUTE DFU DRAINAGE FIXTURE UNIT RTU ROOFTOP UNIT CONTROL VALVE DS DOWNSPOUT SF SQUARE FEET, SUPPLY FAN SHUTOFF VALVE CPO ETR EXISTING TO REMAIN SP SUMP PUMP EWC ELECTRICWATER COOLER SS STAINLESS STEEL. SANITARY SEWER, CHECK VALVE FD FLOOR DRAIN SOIL STACK v BALANCING VALVE WITH PRESSURE PORTS FFA FROM FLOOR ABOVE TRH TOTAL DYNAMIC HEAD 19` WATER METER FFB FROM FLOOR BELOW TFA TO FLOOR ABOVE FF FINISHED FLOOR TFB TO FLOOR BELOW STRAINER FL FLOW LINE TYP TYPICAL STRAINER WITH BLOWOFF FLA FULL LOAD AMPS UL UNDERWRITERS LABORATORIES, RELIEF /SAFETY VALVE FLR FLOOR INC GPM GALLONS PER MINUTE LINO UNLESS NOTED OTHERWISE SOLENOID VALVE HD HEAD, HUB DRAIN UPS UNINTERRUPTIBLE POWER SUPPLY PRESSURE REDUCING VALVE at IE INVERT ELEVATION V VOLT(S) GAS PRESSURE REGULATOR IN WC INCHES OF WATER COLUMN VCP VITRIFIED CLAY PIPE JB JUNCTION BOX VS VENT STACK THERMOSTATIC MIXING VALVE J-BOX JUNCTION BOX VTR VENT THROUGH ROOF PA PIPE ANCHOR WW KILOWATT W/ WITH EJ IXPANSION JOINT MAU MAKEUP AIR UNIT W/0 WITHOUT MAX MAXIMUM WC WATER COLUMN BACKFLOW PREVENTER MBH 1000 BTU PER HOUR WS WASTE STACK • PRESSURE GAUGE WSFU WATER SUPPLY FIXTURE UNIT THERMOMETER UNION FLANGE CONNECTION HOSE BIBB (HB) ---}� NONFREEZE WALL HYDRANT (NW) MANUAL/ AUTOMATIC AIR VENTOR VACUUM RELIEF VALVE CLEANOUT CAP ID WALL CLEANOUT (WCO) A FLOOR CLEANOUT (FCO) �O EXTERIOR CLEANOUT(ECO) 10 ELBOW UP - -�Ei ELBOW DOWN TEE UP TEE DOWN lei - -19 ELBOW UP WITH SHUT -OFF VALVE (SOV) —Q ELBOW DOWN WITH SHUT -OFFVALVE(SOV) TEE UP WITH SHUT -OFF VALVE(SOV) TEE DOWN WITH SHUT -OFF VALVE (SQV) - * .A" WATER HAMMER ARRESTER (WHA) WITH PDI SIZES, (A, B, C, D. & E) RECIRCULATION PUMP flf, P -TRAP GAS COCK TRAP PRIMER TRAP PRIMER WITH DISTRIBUTION UNIT 1/2-CW & 1 /2 "HW DN ►� I (E)4 M.EN'S RESTROOM 2 tNLAKk7tU SCALE: 1/4 " =1 I e P ,l ti GENERAL NOTES: 1. DRAWINGS ARE DIAGRAMMATIC ONLY AND REPRES7,o4T TH` �EKERAL SCOPE - VF THE WORK. REVIEW THE GENERAL NOTES, SPECIFICATIONS AND PLANS FOR ADDITIONAL REQUIREMENTS THAT MAY NOT BE SPECIFICALLY_ CALLED OUT IN THIS PORTION OF THE CONSTRUCTION DOCUMENTS. NOTIFY THE-OWNER'S T - CONSTRUCTION MANAGER OF ANY CONFLICTS OR DISCREPANCIES �'RI012 TO Q SUBMISSION OF BID. - - --- 2. FURNISH A CONSTRUCTION RECORD SET OF "AS— BUILT" DOCUMENTS TO THE OWNER'S CONSTRUCTION MANAGER REFLECTING ANT ✓ARIANCES- OF IN,a AI LED a - PIPING LOCATIONS OR EQUIPMENT CONTRARY TO THE CONSTRUCTION - DOCUMENTS PREPARED BY THE ENGINEER —OF— RECORD- AFTE:(2_ FINAL INSPECTION OF INSTALLED PLUMBING SYSTEMS. 3. FURNISH TO THE OWNER'S CONSTRUCTION MANAGER A COPY OF INSPECTION REPORTS AND APPROVAL CERTIFICATES FROM LOCAL AND STATE INSPECTIONS. 4. INSTALLATION SHALL COMPLY WITH LEGALLY CONSTITUTED CODES AND THE REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION AND ALSO MEET ALL REQUIREMENTS OF THE LANDLORD. 5. PLANS AND SPECIFICATIONS GOVERN WHERE THEY EXCEED CODE REQUIREMENTS. 6. VERIFY LOCATION AND DEPTH OF UTILITIES AT POINTS OF CONNECTION BEFORE START OF PROJECT. 7. REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATION AND MOUNTING HEIGHTS OF PLUMBING FIXTURES. 8. DO NOT SCALE FLOOR PLANS FOR EXACT HORIZONTAL LOCATION OF PIPE ROUTING. 9. VALVES SHALL BE LINE SIZE UNLESS OTHERWISE NOTED. 10. PIPING IN FINISHED AREAS SHALL BE ROUTED CONCEALED; EXPOSED PIPING, WHERE NECESSARY, SHALL BE ROUTED AS HIGH AS POSSIBLE AND TIGHT TO WALLS. 11. COORDINATE ALL WORK WITH OTHER TRADES AND CONTRACTORS. 12. COORDINATE PIPING INSTALLATION WITH STRUCTURAL GRADE BEAMS, FOOTINGS, COLUMN PIERS, ETC. SLEEVE PIPING THROUGH GRADE BEAMS, FOOTING, ETC. WHERE REQUIRED AND AS NOTED ON PLANS. COORDINATE SLEEVE INSTALLATIONS WITH THE ARCHITECT, STRUCTURAL ENGINEER, STRUCTURAL CONTRACTOR AND GENERAL CONTRACTOR BEFORE CONCRETE IS INSTALLED. 13. CLEAN FAUCET AERATORS AND PIPE STRAINERS PRIOR TO TURNING BUILDING OVER TO THE OWNER. 14. PROVIDE TRAP PRIMERS WHERE REQUIRED BY LOCAL AUTHORITIES. 15. COORDINATE PIPE ROUTING AWAY FROM ELECTRICAL PANELS. DO NOT ROUTE PIPING OVER ELECTRICAL PANELS. 16. PAINT ALL EXPOSED GAS AND WATER PIPING USING RUST INHIBITOR PAINT. PAINT AND COLOR SHALL BE COORDINATED WITH THE ARCHITECT AND / OR OWNER. 17. COORDINATE ALL ROOF PENETRATIONS WITH OTHER TRADES. MAINTAIN 10' MINIMUM CLEARANCE FROM ALL AIR INTAKES. MAINTAIN 2' CLEARANCE FROM ALL OTHER EQUIPMENT. 18. INSULATE PIPING ROUTED IN EXTERIOR BUILDING WALLS WITH MINIMUM 2" BAIT INSULATION TO PREVENT FREEZING. 19. WATER HAMMER ARRESTORS SHALL BE SIZE "A" UNLESS NOTED OTHERWISE. 20. GENERAL CONTRACTOR SHALL ROD AND SCOPE WASTE LINE TO LANDLORD'S MAIN PRIOR TO TURNOVER. 21. HARD 90 DEGREE TURNS WILL NOT BE ALLOWED ON WASTE LINES. TURNS MUST BE SWEEPING. ,PLAN NOTES: `./ CONNECT TO LANDLORD PROVIDED EXISTING 4" SANITARY PIPE. FIELD VERIFY INVERT, SIZE, EXACT LOCATION AND DIRECTION OF FLOW PRIOR TO SUBMITTING BID. CONNECT TO LANDLORD PROVIDED EXISTING 2 -1/2" VENT LINE. FIELD VERIFY EXACT LOCATION AND SIZE PRIOR TO SUBMITTING BID. CONNECT NEW CW LINE TO EXISTING 1 "CW SUPPLY. SEE DRAWINGS FOR PIPE CONNECTION SIZE(S). DO NOT INSTALL PLUMBING PIPING OVER ELECTRICAL PANELS OR EQUIPMENT. PROVIDE CARTRIDGE FILTER UNDER WATER FEATURE. PROVIDE BACK FLOW PROTECTION PER LOCAL AUTHORITIES REQUIREMENTS ON WATER SUPPLY LINE. 6 INSTALL WATER HAMMER ARRESTORS IN THE DOMESTIC COLD AND HOT WATER PIPING AS SHOWN ON THE WATER RISER DIAGRAM. WATER HAMMER ARRESTORS TO BE LOCATED IN AN ACCESSIBLE LOCATION. UNITS MANUFACTURED BY SIOUX AND PRECISION PLUMBING PRODUCTS ARE ACCEPTABLE. (D FOR EXACT FLOOR DRAIN LOCATIONS REFER TO ARCHITECTS FINISH PLAN. PATCH AND REPAIR SLAB TO MATCH SURROUNDING FINISH. ,9 ROUTE INDIRECT DRAIN LINE TIGHT TO WALL, TURN DOWN TO FUNNEL FLOOR DRAIN. FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE :i' AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING • D i THE • i• SHALL CONTACT A. ENGINEER OR OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL BIDDING COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. i •` S SHALL HAVE A WORKING KNOWLEDGE OF i ACODES AND WITHSTANDING. ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT i ' A •. ARCHITECT, OR OWNER OF APPARENT DISCREPANCIES • •! S 1 ! NOTE: INFORMATION ON THIS SHEET PERTAINING TO THE EXISTING PLUMBING SYSTEM IS BASED ON RECORD DRAWINGS AVAILABLE AT THE TIME OF DESIGN. FIELD VERIFY ALL EXISTING CONDITIONS AND NOTIFY ARCHITECT AND ENGINEER IMMEDIATELY IF ANY DISCREPANCIES ARE FOUND. HENDERSON f"ENGINEERSK 8325 LENEXA DRIVE LEND(k KS 66214 Ta 913 742 5000 FAx 913 742 5001 WWWj eil -engA6 e 1050001129 FL CORPORATE NUMBER EB 7606 EXPIRES 2/28/11 HDOO N �® I'll r °te= u• o °t E c3 a, c❑. v CO (yj o LL "C V/ ■ r"j w t/a E�j ui v iz C5 "_0� �. ofi z O d i • f� N W 00 yJ N 2 2 ¢ Ce J v to %D as co zzzZ Z. � ¢4� °aECC b = uiLu =* ri���� ft J J J J U E E a a W an m m Co 0 0 .-, r, .-� ,-� .-, .-, '1 r, 0 0 0 0 0 0 0 0 0 0 N N N N N N N N N N o .-� N N e-1 e-i O O *� O � O O o N 0 N 0 tf1 tt? 1! co N N N Zd ea%-1 N r • • Limlum a indicated °te= 10/14/10 z" c3 Checked By: HEI Job Number. 16401 .ice.: r • • Limlum a " "' As indicated °te= 10/14/10 D-ra-w-W-W. HEI Checked By: HEI Job Number. 16401 i • " "' As indicated °te= 10/14/10 D-ra-w-W-W. HEI Checked By: HEI Job Number. 16401 CELEBRATING Drawing: ® ► / 1970 YEARS 2010