10-1088-043V) w _ m J z z w Y_ MASTER LEGEND MB ABBREVIATIONS, NOTE: THIS IS A NECESSARILY USED ON THE DRAWINGS. 1 I PLUMBING PLAN NO E CALLOUI — DOMESTIC COLD WATER (CW) r SCW SOFTENED COLD WATER (SCW) PLUMBING EQUIPMENT DESIGNATION. (CONTRACTOR FURNISHED AND s. 1 INSTALLED). REFER TO PLUMBING FIXTURE OR EQUIPMENT SCHEDULES -- DOMESTIC HOT WATER (HW) 2 - -- DOMESTIC HOT WATER RECIRC. (HWR) EQUIPMENT DESIGNATION (OWNER FURNISHED, CONTRACTOR 1 INSTALLED) th 140° 140° DOMESTIC HOT WATER (140 °) GL1 MECHANICAL EQUIPMENT DESIGNATION (CONTRACTOR FURNISHED AND T TRAP PRIMER LINE (T) 1 INSTALLED UNLESS NOTED OTHERWISE) 5 SOIL PIPING -ABOVE FLOOR (S) CONNECTION POINT OF NEV! WORK TO EXISTING ---S --- SOIL PIPING - BELOW FLOOR (S) 1 DETAIL. REFERENCE UPPER NUMBER INDICATES DETAIL NUMBER LOWER W WASTE PIPING - ABOVE FLOOR (W) M1 NUMBER INDICATES SHEET NUMBER —W WASTE PIPING -BELOW FLOOR (W) SECTION CUT DESIGNATION M1 GW — — —GW— — — GREASE WASTE -ABOVE FLOOR (GW) GREASE WASTE - BELOW FLOOR (GW) ST STORM DRAIN -ABOVE FLOOR (ST) STANDARD MOUNTING HEIGHTS — -- -- —ST— -- -- — STORM DRAIN - BELOW FLOOR (ST) OST OVERFLOW STORM DRAIN - ABOVE FLOOR (OST) PLUMBING (AFF, AEG, UNLESS NOTED OTHER4VNSE) -- -- - -VBG -- -- -- VENT BELOW GRADE (VBG) REFER TOTI -Im. ARCHITECTURAL DRAWINGS FAR PLUMBING FIXTURE MOUNTING HEIGHTS. C9NCY, INSTALL — -- -VBF -- — VENT BELOW FLOOR (VBF) PLUMBING FIXTURES V'JITH'iHE MOUNTING HEIGHTS AS C.ISTED BELO"v'J WITH FINAL APPROVAL BY THE ARCHITECT. ID INDIRECT DRAIN (ID) CDH CONDENSATE DRAIN - HIGH EFFICIENCY RTU (CDH) ADA ACCESSIBLE DRINKING FOUNTAIN 17' FLOOR TO RIM CD CONDENSATE DRAIN (CD) ADA ACCESSIBLE LAVATORIES 34` FLOOR TO RIM ACD— AUXILIARY CONDENSATE DRAIN (ACD) ADA ACCESSIBLE SHOWER VALVES 38w MINIMUM TO 48" MAXIMUM —SPD— SUMP OR SEWAGE PUMP DISCHARGE (SPD) FLOOR TO CENTERLINE G NATURAL GAS (G) ADA ACCESSIBLE TUB VALVES CENTER BETWEEN GRAB BAR — — — —G— — — — NATURAL GAS ON ROOF (G) AND TUB RIM MPG MEDIUM PRESSURE NATURAL GAS (MPG) ADA ACCESSIBLE. URINALS 17" FLOOR TO RIM — — —MPG — — — MEDIUM PRESSURE NATURAL GAS ON ROOF (MPG) ADA ACCESSIBLE WATER CLOSET 17" TO 19° FLOOR TO NPW NON POTABLE WATER (NPW) TOP OF SEAT LPG LIQUIFIED PETROLEUM GAS (LPG) ADA ACCESSIBLE WATER COOLER 35" FLOOR TO RIM WS WATER SERVICE (WS) ADULT STANDARD DRINKING FOUNTAIN 40" FLOOR TO RIM FP FIRE PROTECTION (FP) ADULT STANDARD WATER COOLER 30' FLOOR TO RIM PD CONDENSATE PUMP DISCHARGE (PD) CHILD STANDARD DRINKING FOUNTAIN 30° FLOOR TO RIM CHILD STANDARD WATER COOLER 14w FLOOR TO RIM — ®— — — EXISTING PIPING TO BE REMOVED CHILD URINAL 14' FLOOR TO RIM EXISTING PIPING TO REMAIN CLINIC SERVICE SINKS 30" FLOOR TO RIM V VENT PIPING (V) JANITOR'S SINK FAUCET FITTINGS 42' FLOOR TO CENTERLINE AW ACID WASTE - ABOVE FLOOR (AW) HOSE BIBBS 36° AFF TO CENTERLINE — — — —AW— — — — ACID WASTE - BELOW FLOOR (AW) ICE MAKER OUTLET BOXES 24" FLOOR TO CENTER OF BOX AV ACID VENT (AV) LAVATORY OR SINK 31" FLOOR TO RIM CA COMPRESSED AIR (CA) NON FREEZE HYDRANT 18 °AFG TO CENTERLINE —Al— MEDICAL AIR INTAKE (AI) SHOWER HEADS 6'-0° MEN & 5'-6" WOMEN MA MEDICAL AIR (MA) FLOOR TO CENTERLINE MV MEDICAL VACUUM (MV) SHOWER VALVES 48° MEN & 42® WOMEN FLOOR VE MEDICAL VACUUM EXHAUST (VE) TO CENTERLINE EV EVACUATION (EV) STANDARD URINALS 22" FLOOR TO RIM CO CARBON DIOXIDE (CO) SURGEON'S SCRUB -UP SINKS 35 FLOOR TO FRONT RIM N NITROGEN (N) TUB VALVES 32" FLOOR TO CENTELINE 0 OXYGEN (0) WASHING FJIACHINE OUTLET BOXES 42" FLOOR TO RIM WATER CLOSET 15' FLOOR TO RIM NO NITROUS OXIDE (NO) OXYGEN OUTLET ABBREVIATIONS On NITROUS OXIDE OUTLET AFF ABOVE FINISHED FLOOR MH MANHOLE MEDICAL AIR OUTLET AFG ABOVE FINISHED GRACIE MIN MINIMUM AHU AIR HANDLING UNIT N/C NORMALLY CLOSED 0 NITROGEN OUTLET BFF BELOW FINISHED FLOOR N/0 NORMALLY OPEN - -4 MEDICAL VACUUM INLET BFG BELOW FINISHED GRADE. ORD OVERFLOW ROOF DRAIN ® SQUARE FLOOR DRAIN SIZE &TYPE BOP BOTTOM OF PIPE PDI PLUMBING DRAINAGE INSTITUTE (FS). BOS BOTTOM OF STRUCTURE: PVC POLYVINYL CHLORIDE ROUND FLOOR DRAIN (ED), SIZE& TYPE BTU BRITISH'THERMAL UNIT PRV PRESSURE REDUCING VALVE (0) ROOF DRAIN (RD), SIZE & TYPE CPVC CHLORINATED POLYVCNYL CHLORIDE RD ROOF DRAIN ON DOWN RPM REVOLUTIONS PER MINUTE BALL VALVE DEN DRAINAGE FIXTURE UNIT RTU ROOFTOP UNIT "��+ CONTROL VALVE DS DOWNSPOUT SF SQUARE. FEET, SUPPLY FAN SHUTOFF VALVE ETR EXISTING TO REMAIN SP SUMP PUMP EWC ELECTRIC WATER COOLER SS STAINLESS STEEL, SANITARY SEWER, CHECK VALVE FD FLOOR DRAIN SOIL STACK, BALANCING VALVE WITH PRESSURE PORTS F'FA FROM FLOOR ABOVE TDH TOTAL DYNAMIC HEAD WATER METER FFB FROM FLOOR BELOW TEA TO FLOOR ABOVE FF FINISHED FLOOR TER TO FLOOR BELOW STRAINER i v! FL FLOW LINE TYR TYPICAL STRAINER WITH BLOWOFF FLA FULL LOADAMPS UL UNDERWRITERS LABORATORIES. ]�. RELIEF/SAFETYVALVE FLR FLOOR INC. 5' GPI.1 GALLONS PER MINUTE UNO UNLESS NOTED OTHERWISE ��— SOLENOID VALVE HD HEAD, HUB DRAIN UPS UNINTERRUPTIBLE POWER SUPPLY p PRESSURE REDUCING VALVE IE INVERT ELEVATION V VOLT(S) IN WC INCH -S OF WATER COLUMN VCR VITRIFIED CLAY PIPE pPq- GAS PRESSURE REGULATOR JB JUNCTION BOX VS VENT STACK THERMOSTATIC MIXING VALVE J -BOX JUNCTION BOX VTR VENT THROUGH ROOF FA PIPE ANCHOR kW KILO`1JATT W/ WITH E1 MAU MAKE -UP AIR UNIT W/O WITHOUT EXPANSION JOINT MAX MAXIMUM VJC WATER COLUMN BACKFLOW PREVENTER MBH 1000 BTU PER HOUR V'JS WASTE STACK 9 PRESSURE GAUGE WSFU WATER SUPPLY FIXTURE UNIT THERMOMETER UNION -- -- FLANGE CONNECTION HOSE BIBB (HB) -- ----}t NONFREEZE WALL HYDRANT (NW) 'i MANUALS' AUTOMATIC AIR VENT OR VACUUM RELIEF VALVE CLEANOUT CAP 04 WALL CLEANOUT (WCO) ® FLOOR CLEANOUT (FCO) EXTERIOR CLEANOUT (ECO) ELBOW UP -+7 ELBOW DOWN TEE UP TEE DOWN -----° iQ ELBOW UP WITH SHUT -OFF VALVE (SOV) ----+� ELBOW DOWN WITH SHUT -OFF VALVE (SOV) TEE UP WITH SHUT -OFF VALVE (SOV) TEE DOWN WITH SHUT -OFF VALVE (SOV) * aAff WATER HAMMER ARRESTER (WHA) WITH PDI SIZES, (A, B. C, D, & E) RECIRCULATION PUMP ;m P -TRAP GAS COCK +-- TRAP PRIMER TRAP PRIMER WITH DISTRIBUTION UNIT wAsimm I ME N' Rr S E001'flt WOMEN _ RESTROOM SCALE: 1,`4 " =1' -0" 0 m" WC -1 i; w •s FAME C� UPI I NOTE € ✓ // /T REFER TO SHEET P510 l,.? _ / FOR ADDITIONAL PIPE it SIZES NOT SHOWN, 1/2"T cV P 1 /2 "HW F s 6 c. " 1,l2 "HWR j r7 ) MV -1 uj I I SAL. ES AREA ( 1 _1 -1 {2"QW 4 _ TttiC.l4�VIS -1/2 HW - i _ I 1 2 "HWR 1 Ci 1( E r m„ /'-(. 44"TEA 0i it-49 1 "m iq out ! PIS e R GENERAL NOTES: fr r s. E5I a 00 a r 2 th CA 1 DRAWINGS INFORMATION ON THIS SHEET PERTAINING TO THE EXISTING PLUMBING SYSTEM IS BASED ON RECORD I DESIGN. FIELD VERIFY ALL EXISTING CONDITIONS AND NOTI ENGINEER ARCHITECT AND i