Loading...
10-1088-042PLUMBING M �oTE. THIS IS A MASTER LEGEND AND NOT ALL SYMBOLS, ABBREVIATIONS, ETC. ARE NECESSARILY USED ON THE DRAWINGS. ANNOTATION PIPING 1 PLUMBING PLAN NOTE CALLOUT — DOMESTIC COLD WATER (CM SCW SOFTENED COLD WATER (SCW) PLUMBING EQUIPMENT DESIGNATION, (CONTRACTOR FURNISHED AND INSTALLED). REFER TO PLUMBING FIXTURE OR EQUIPMENT SCHEDULES _— DOMESTIC HOT WATER (HW) - -- DOMESTIC HOT WATER RECIRC. (HWR) EQUIPMENT DESIGNATION (OWNER FURNISHED, CONTRACTOR INSTALLED) 140° 140° DOMESTIC HOT WATER (140 °) T TRAP PRIMER LINE (T) CU MECHANICAL EQUIPMENT DESIGNATION (CONTRACTOR FURNISHED AND INSTALLED UNLESS NOTED OTHERWISE) S SOIL PIPING -ABOVE FLOOR (S) CONNECTION POINT OF NEW WORK TO EXISTING —S SOIL PIPING - BELOW FLOOR (S) DETAIL REFERENCE UPPER NUMBER INDICATES DETAIL NUMBER LOWER W WASTE PIPING -ABOVE FLOOR (W) M1 NUMBER INDICATES SHEET NUMBER --W-- WASTE PIPING - BELOW FLOOR (W) GW GREASE WASTE -ABOVE FLOOR (GW) SECTION CUT DESIGNATION — — —GW— — — GREASE WASTE - BELOW FLOOR (GW) ST STORM DRAIN -ABOVE FLOOR (ST) STANDARD MOUNTING HEIGHTS — — — —ST— — — — STORM DRAIN - BELOW FLOOR (ST) OST OVERFLOW STORM DRAIN _ ABOVE FLOOR (OST) PLUMBING (AFF„ AFG, UNLESS NOTED OTHERWISE) — — —VBG -- — -- VENT BELOW GRADE (VBG) REFER TO THE ARCHITECTURAL DRAWINGS FOR PLUMBING FIXTURE MOUNTING HEIGHTS. UNO, INSTALL ®— — VBF ® — -- VENT BELOW FLOOR (VBF) PLUMBING FIXTURES WITH THE MOUNTING HEIGHTS AS LISTED BELOVdJdiTH FINAL APPROVAL BY THE CD INDIRECT DRAIN (ID) ARCHITECT. CDH CONDENSATE DRAIN - HIGH EFFICIENCY RTU (CDH) ADA ACCESSIBLE DRINKING FOUNTAIN 17" FLOOR TO RIM CD CONDENSATE DRAIN (CD) ADA ACCESSIBLE LAVATORIES 34" FLOOR TO RIM ACD— AUXILIARY CONDENSATE DRAIN (ACD) ADA ACCESSIBLE SHOWER VALVES 38" MINIMUM TO 48" MAXIMUM —SPD— SUMP OR SEWAGE PUMP DISCHARGE (SPD) FLOOR TO CENTERLINE G NATURAL GAS (G) ADA ACCESSIBLE TUB VALVES CENTER BETWEEN GRAB BAR — — — —G— — — — NATURAL GAS ON ROOF (G) AND TUB RIM MPG MEDIUM PRESSURE NATURAL GAS (MPG) ADA ACCESSIBLE URINALS 17" FLOOR TO RIM — — —MPG— — — MEDIUM PRESSURE NATURAL GAS ON ROOF (MPG) ADA ACCESSIBLE WATER CLOSET 17" TO 13" FLOOR TO NPW NON POTABLE WATER (NPW) TOP OF SEAT LPG LIQUIFIED PETROLEUM GAS (LPG) ADA ACCESSIBLE WATER COOLER 35" FLOOR TO RIM WS WATER SERVICE (WS) ADULT STANDARD DRINKING FOUNTAIN 40" FLOOR TO RIM FP FIRE PROTECTION (FP) ADULT STANDARD WATER COOLER 30" FLOOR TO RIM PD CONDENSATE PUMP DISCHARGE (PD) CHILD STANDARD DRINKING FOUNTAIN 30" FLOOR TO RIM — — — EXISTING PIPING TO BE REMOVED CHILD STANDARD WATER COOLER 14" FLOOR TO RIM CHILD URINAL 14" FLOOR TO RIM EXISTING PIPING TO REMAIN CLINIC SERVICE SINKS 30" FLOOR TO RIM V VENT PIPING (V) JANITOR'S SINK FAUCET FITTINGS 42" FLOOR TO CENTERLINE AW ACID WASTE -ABOVE FLOOR (AW) HOSE BIBBS 36 "AFF TO CENTERLINE — -- — —AW— -- -- — ACID WASTE - BELOW FLOOR (AW) ICE MAKER OUTLET BOXES 24" FLOOR TO CENTER OF BOX AV ACID VENT (AV) LAVATORY OR SINK 31" FLOOR TO RIM CA COMPRESSED AIR (CA) NON FREEZE HYDRANT 18" AFG TO CENTERLINE —Al— MEDICAL AIR INTAKE (Al) SHOWER HEADS 6'-0' MEN & 5'-6" WOMEN MA MEDICAL AIR (MA) FLOOR TO CENTERLINE MV MEDICAL VACUUM (MV) SHOWER VALVES 48' MEN & 42" WOMEN FLOOR VE MEDICAL VACUUM EXHAUST (VE) TO CENTERLINE EV EVACUATION (EV) STANDARD URINALS 22" FLOOR TO RIM CO CARBON DIOXIDE (CO) SURGEON'S SCRUB -UP SINKS 35" FLOOR TO FRONT RIM N NITROGEN (N) TUB VALVES 32" FLOOR TO CENTELINE O OXYGEN (0) WASHING MACHINE OUTLET BOXES 42" FLOOR TO RIM NO NITROUS OXIDE (NO) WATER CLOSET 15" FLOOR TO RIM ---- ---- -e OXYGEN OUTLET ABBREVIATIONS — _ NITROUS OXIDE OUTLET AFF ABOVE FINISHED FLOOR !"CH MANHOLE p MEDICAL AIR OUTLET AFG ABOVE FINISHED GRADE MIN MINIMUM AHLU AIR HANDLING UNIT N/C NORMALLY CLOSED NITROGEN OUTLET BFF BELOW FINISHED FLOOR N/O NORMALLY OPEN ---- ---- -4 MEDICAL VACUUM INLET BEG BELOW FINISHED GRADE ORD OVERFLOW ROOF DRAIN ® SQUARE FLOOR DRAIN (FS), SIZE &TYPE BOP BOTTOM OF PIPE PDI PLUMBING DRAINAGE INSTITUTE ROD BOTFO'A OF STRUCTURE PVC POLYVINYL CHLORIDE ROUND FLOOR DRAIN (FD), SIZE & TYPE BTU BRITISH THERMAL UNIT PRV PRESSURE REDUCING VALVE (0) ROOF DRAIN (RD), SIZE & TYPE CPVC CHLORINATED POLYVINYL CHLORIDE RD ROOF DRAIN BALL VALVE DN DO "NN RPM REVOLUTIONS PER MINUTE DFU DRAINAGE. FIXTURE UNIT RTU ROOFTOP UNIT �*'�'+ CONTROL VALVE DS DOWNSPOUT SF SQUARE FEET, SUPPLY FAN SHUTOFF VALVE ETR EXISTING TO REMAIN SP SUMP PUMP EWC ELECTRIC WATER COOLER SS STAINLESS STEEL, SANITARY SEWER, CHECK VALVE FD FLOOR DRAIN SOIL STACK BALANCING VALVE WITH PRESSURE PORTS FFA FROM FLOOR ABOVE TDH TOTAL DYNAMIC HEAD � WATER METER FFB FROM FLOOR BELOW TFA TO FLOOR ABOVE FF' FINISHED FLOOR TFB TO FLOOR BELOW 1 vi STRAINER FL FLOW LINE TYP TYPICAL STRAINER WITH BLOWOFF FLA FUL.LLOADAAPS UL UNDERWRITERS LABORATORIES, RELIEF /SAFETY VALVE FLR FLOOR INC. GPM GALLONS PER LIINUTE UNO UNLESS NOTED OTHERWISE _f SOLENOID VALVE HD HEAD, HUB DRAIN UPS UNINTERRUPTIBLE POWER SUPPLY p PRESSURE REDUCING VALVE IE INVERT ELEVATION V VOLT(S) pPq GAS PRESSURE REGULATOR IN VIC INCHES OF WATER COLUMN VCR VITRIFIED CLAY PIPE 11 JB JUNCTION BOX Vs VENT STACK THERMOSTATIC MIXING VALVE J -BOX JUNCTION BOX VTR VENT THROUGH ROOF N PA PIPE ANCHOR kW KILOWATT W/ WITH EJ MALT MAKE -UP AIR UNIT W/C WITHOUT EXPANSION JOINT MAX MAXIMUM WC WATER COLUMN BACKFLOW PREVENTER MBH 1000 BTU PER HOUR WS WASTE STACK 4 PRESSURE GAUGE VJSFU WATER SUPPLY FIXTURE UNIT THERMOMETER ---� UNION FLANGE CONNECTION HOSE BIBB (HB) --{+ NONFREEZE WALL HYDRANT (NW) 1 MANUAL/ AUTOMATIC AIR VENT OR VACUUM RELIEF VALVE CLEANOUT CAP WALL CLEANOUT (WCO) @? FLOOR CLEANOUT (FCO) ® EXTERIOR CLEANOUT (ECO) - -00 ELBOW LIP °+a ELBOW DOWN TEE UP TEE DOWN - ----+Q ELBOW UP WITH SHUT -OFF VALVE (SOV) --+-2 ELBOW DOWN WITH SHUT -OFF VALVE (SOV) Ibt TEE UP WITH SHUT -OFF VALVE (SOV) TEE DOWN WITH SHUT -OFF VALVE (SOV) * „A" WATER HAMMER ARRESTER (WHA) WITH PDI SIZES, (A, B, C, D. & E) RECIRCULATION PUMP P -TRAP +T+- GAS COCK TRAP PRIMER TRAP PRIMER WITH DISTRIBUTION UNIT I 317-SCALE: - i • r . . r; r i MEN'S li'll o tv r N , "BEST O0 4 9 F r i w INFORMATION ON THIS SHEET PERTAINING TO THE EXISTING PLUMBING SYSTEM IS BASED ON R DRAWINGS AVAILABLE AND NOTIFY ARCHITECT AND ENGINEER IMMEDIATELY IF ANY DISCREPANCIES ARE FOUND. milli "49 U) C? ra �ujb va