12-591-025
i P G I J P _4 I :.1 l Q I / I Q ( y I I �,.i I 11 i 1 G I I J i 114 1 N KI m L J HI G F E I D I A 1 TYPE: SIMMENS r 1 • • r MTG: RECESSED NEW PANEL i BUS: 125 AMPS MAIN: MLO LOAD: i r r i ► r �� (1) 1500 VA X 2 SMALL APPLIANCES CIRCUITS: NEW METER ► i �I® NEW DESCRIPTION ��� I PANEL ABBREVATIONS r r r r r r r "A. 1 GFCI GROUND -FAULT CIRCUIT - INTERRUPTER 720 VA 1 I I DOOR BELL PUSH BUTTON AFCI ARC -FAULT CIRCUIT INTERRUPTER CENTER I I 1 DOUBLE OVEN 9,000 VA 50 A MCB Q I I 1120/24QV,10,3W I 120 V 120V SMOKE ALARM (EQUAL TO KIDDE MODEL 720 VA WP WEATHER PROOF 4,500 VA �' SD 120/24OV,10,3W 150 A MCB - -I - -� CIRCUIT. ALL SMOKE ALARMS SHALL BE INTERCONNECTED. I/C INSTALLED IN ATTIC SPACE — — — — — — — — — — — — J (b) GENERAL LOADS: VA SCR MINIMUM AIC OF BREAKER IN PANEL AND 10,000 VA TIE INTO EXISTING EXISTING 3 #1 THWN CU NEW 3 #8 THWN CU & 120V COMBINATION CARBON MONOXIDE / SMOKE ALARM (EQUAL TO KIDDE MODEL KN- COSM -IB) AS NEEDED. & 1 #6 THAN CU GND. IN 1 #8 THWN CU COND. 39,451 VA EXIST. 1 1/2' CONDUIT. IN NEW 1" CONDUIT. CONNECTED TO LINE SIDE OF LOCAL CIRCUIT, NEW 1 #4 THNW GND. IN N NEW NEW 3 #3/0 THWN 1/2' CONDUIT TO (2) 6' -0" OR EQUAL, CU IN 2' CONDUIT IRON RODS 10' -0' APART RE EXISTING TO BE REMOVED. TO FPL POLE. & 3/4" CW LINE. EXIST. ELECTRICAL RISER E EXISTING. O N.T.S. O ELECTRICAL PANEL INSTALLATION NOTES G.F.I. DUPLEX OUTLET 11111111 FLEXIBLE CONDUIT A) MOUNT WIRING DEVICES CENTER LINE 0 HEIGHT ABOVE FINISHED FLOOR INDICATED BELLOW, IN ABOVE - COUNTER DUPLEX RECEPTACLE — CONDUIT RUN EXPOSED ALL UNITS: ABOVE - COUNTER G.F.I. DUPLEX RECEPTACLE — CONDUIT CONCEALED IN WALLS OR OVERHEAD (SHOWN WITH TWO HOT & NEUTRAL) A) RECEPTACLES: @ 18" B) LIGHT SWITCHES: 0 46" [�] ® TV OUTLET — 4 — CONDUIT IN OR UNDER THE SLAB ", (SHOWN WITH HOT, NEUTRAL & GROUND) C) TELEPHONE JACKS: KITCHEN 0 42 ALL OTHRES 0 18" TELEPHONE OUTLET D) THERMOSTATS: 0 46' 1x4 FLUORESCENT LIGHT FIXTURE ® © DATA OUTLET B) BATHROOM WALL MOUNTED FIXTURES: 6" OVER THE CENTER LINE OF THE Q COMMUNICATION & DATA STRUCTURAL OUTLET MIRROR OR AS SHOWN IN THE ARCHITECTURAL DRAWINGS. COMBINATION. 20 FLUORESCENT LIGHT FIXTURE C) LIGHT SCONCES TO BE MOUNTED 0 6' -6" A.F.F. OR AS SHOWN IN IN THE ARCHITECTURAL DRAWINGS. SCONCES MOUNTED BELOW 6' -6" SHALL S SINGLE POLE SWITCH NOT PROTUDE NOT MORE THAT 4" INTO WALKWAYS, HALLS, CORRIDORS, S3 THREE WAY'.SWITCH 2x2 FLUORESCENT LIGHT FIXTURE OR AISLES. COORDINATE WITH ARCHITECTURAL ELEVATIONS. S4 FOUR WAY SWITCH LEGEND GENERAL NOTES (BASED ON NEC 2008) or Se SERVICE BREAKER (FACTORY INSTALLED) E) 4' FLUORESCENT LIGHT STRIP 1. ALL 125 -VOLT, SINGLE - PHASE, 15 AND 20 AMPERE RECEPTACLES CEILING FAN CONTROL SWITCH COMBINATION 0 SURFACE MTD. FLUORESCENT LIGHT FIXTURE INSTALLED AT DWELLING UNITS LOCATION'S, AS SPECIFIED IN THE NEC 210.8(A), SHALL BE GFCI PROTECTED. SD DIMMER SWITCH -C SURFACE FLUORESCENT, UNLESS NOTED 2, ALL 125 -VOLT, SINGLE - PHASE, 15 AND 20 AMPERE RECEPTACLES PENDANT LIGHT FIXTURE INSTALLED AT DWELLING UNITS LOCATION'S, AS SPECIFIED IN THE P NEC 210.52, SHALL BE LISTED TAMPER - RESISTANT RECEPTACLES E(ij EXHAUST FAN 0 RECESS HI -HAT LIGHT FUXTURE AS PER NEC 406 -11. MOTOR WALL WASH LIGHT FIXTURE 3. ALL 125 AND 250 VOLT, 15 AND 20 AMPERE NON LOCKING �T-� � l RECEPTACLES INSTALLED AT DWELLING UNITS IN DAMP OR WET ® STARTER OR CONTROL PANEL win WALL MOUNTED LIGHT FIXTURE LOCATION'S, AS SPECIFIED IN THE NEC 406.8(A)(B), 9 COMBINATION STARTER ® r SHALL BE A LISTED WEATHER- RESISTAN TYPE. EY DISCONNECT SWITCH - WP INDICATES WEATHERPROOF (TYP.) 3. ALL 120 VOLT, SINGLE PHASE, 15 AND 20 AMPERE BRANCH min � 0� CEILING FAN mmmm 340 DISCONNECT SIZE (3 DENOTESMO. POLES, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, 60 DENOTES DISCONNECT RATED AMPERAGE, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, 40 DENOTES.FUSE SIZE [NF DENOTES NON- FUSED] CLOSETS, HALLWAYS, OR SIMILIR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED ARC -FAULT CIRCUIT INTERRUPTER, COMBINATION TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT AS PER NEC 210.12(A)(B). mi®����ri��� �����1'\ � ®IQ's■ ■J����� Ulm �mmmm min ►I o : r 2 VERIFY EQUIPMENT NAME PLATE PRIOR TO INSTALL COOLING LOAD LARGER THAN HEATING LOAD. OUTSIDE HOUSE INSIDEE GARAGE INSIDE HOUSE A I CONSTRUCTION NOTES: 1. ALTERATIONS TO EXISTING WORK BEING OF SUCH NATURE THAT ALL FACETS OF THE WORK ARE IMPOSSIBLE TO DETAIL AND SPECIFY. IT IS THEREFORE THE RESPONSIBILITY OF THE CONTRACTOR TO CARE- FULLY EXAMINE THE BUILDING AND THE GROUNDS AND FAMILIARIZE HIMSELF WITH THE CONDITIONS AND RELATE THESE CONDITIONS TO THE SCOPE OF THE PROPOSED WORK PRIOR TO BIDDING. 2. ANY EXISTING INSTALLATION PROBLEMS OR EXISTING CODE VIOLATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT /ENGINEER PRIOR TO BIDDING. 3. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE OWNER ALL THE CONSTRUCTION WORK AND NOTIFY HIM 72 HOURS IN ADVANCE OF COMMENCING ANY WORK. 4. ANY ELECTRICAL WORK WHICH WILL INTERFERE WITH THE RESIDENTS NORMAL OPERATION SHALL BE NOTIFIED IN ADVANCE TO THE OWNER AND THE HOURS AND DAYS OF THE WEEK TO DO THE WORK SHALL BE APPROVED BY HIM. 5. COORDINATE LOCATIONS OF ALL LIGHTING, RECEPTACLES & EQUIPMENT W/ OWNER PRIOR TO INSTALL. NOTIFY ENG. OF ANY DISCREPANCIES. LEGEND GENERAL NOTES (BASED ON NEC 2008) 1. ALL 125 -VOLT, SINGLE - PHASE, 15 AND 20 AMPERE RECEPTACLES INSTALLED AT DWELLING UNITS LOCATION'S, AS SPECIFIED IN THE NEC 210.8(A), SHALL BE GFCI PROTECTED. 2. ALL 125 -VOLT, SINGLE - PHASE, 15 AND 20 AMPERE RECEPTACLES INSTALLED AT DWELLING UNITS LOCATION'S, AS SPECIFIED IN THE NEC 210.52, SHALL BE LISTED TAMPER- RESISTANT RECEPTACLES AS PER NEC 406 -11. 3. ALL 125 AND 250 VOLT, 15 AND 20 AMPERE NON LOCKING RECEPTACLES INSTALLED AT DWELLING UNITS IN DAMP OR WET LOCATION'S, AS SPECIFIED IN THE NEC 406.8(A)(B), SHALL BE A LISTED WEATHER-RESI STAN TYPE. 3. ALL 120 VOLT, SINGLE PHASE, 15 AND 20 AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED IN DWELLING UNITS FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILIR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED ARC -FAULT CIRCUIT INTERRUPTER, COMBINATION TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT AS PER NEC 210.12(A)(B). ELECTRICAL SYMBOL LEGEND CDWELLING UNITS) (b) GENERAL LOADS: LOAD (VA) (1) 1500 VA X 2 SMALL APPLIANCES CIRCUITS: NEW METER EXIST'G 6,417 VA NEW 2,481 VA O I PANEL ABBREVATIONS PANEL QUADRUPLE (DOUBLE DUPLEX) © "A. 1,000 VA GFCI GROUND -FAULT CIRCUIT - INTERRUPTER 720 VA DUPLEX OUTLET I I DOOR BELL PUSH BUTTON AFCI ARC -FAULT CIRCUIT INTERRUPTER CENTER I I 6,500 VA DOUBLE OVEN 9,000 VA 50 A MCB 1,000 VA I I 1120/24QV,10,3W I 120 V 120V SMOKE ALARM (EQUAL TO KIDDE MODEL 720 VA WP WEATHER PROOF 4,500 VA �' SD 120/24OV,10,3W 150 A MCB - -I - -� CIRCUIT. ALL SMOKE ALARMS SHALL BE INTERCONNECTED. I/C INSTALLED IN ATTIC SPACE — — — — — — — — — — — — J (b) GENERAL LOADS: VA SCR MINIMUM AIC OF BREAKER IN PANEL AND 10,000 VA TIE INTO EXISTING EXISTING 3 #1 THWN CU NEW 3 #8 THWN CU & 120V COMBINATION CARBON MONOXIDE / SMOKE ALARM (EQUAL TO KIDDE MODEL KN- COSM -IB) AS NEEDED. & 1 #6 THAN CU GND. IN 1 #8 THWN CU COND. 39,451 VA EXIST. 1 1/2' CONDUIT. IN NEW 1" CONDUIT. CONNECTED TO LINE SIDE OF LOCAL CIRCUIT, NEW 1 #4 THNW GND. IN N NEW NEW 3 #3/0 THWN 1/2' CONDUIT TO (2) 6' -0" OR EQUAL, CU IN 2' CONDUIT IRON RODS 10' -0' APART RE EXISTING TO BE REMOVED. TO FPL POLE. & 3/4" CW LINE. EXIST. ELECTRICAL RISER E EXISTING. O N.T.S. O A I CONSTRUCTION NOTES: 1. ALTERATIONS TO EXISTING WORK BEING OF SUCH NATURE THAT ALL FACETS OF THE WORK ARE IMPOSSIBLE TO DETAIL AND SPECIFY. IT IS THEREFORE THE RESPONSIBILITY OF THE CONTRACTOR TO CARE- FULLY EXAMINE THE BUILDING AND THE GROUNDS AND FAMILIARIZE HIMSELF WITH THE CONDITIONS AND RELATE THESE CONDITIONS TO THE SCOPE OF THE PROPOSED WORK PRIOR TO BIDDING. 2. ANY EXISTING INSTALLATION PROBLEMS OR EXISTING CODE VIOLATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT /ENGINEER PRIOR TO BIDDING. 3. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE OWNER ALL THE CONSTRUCTION WORK AND NOTIFY HIM 72 HOURS IN ADVANCE OF COMMENCING ANY WORK. 4. ANY ELECTRICAL WORK WHICH WILL INTERFERE WITH THE RESIDENTS NORMAL OPERATION SHALL BE NOTIFIED IN ADVANCE TO THE OWNER AND THE HOURS AND DAYS OF THE WEEK TO DO THE WORK SHALL BE APPROVED BY HIM. 5. COORDINATE LOCATIONS OF ALL LIGHTING, RECEPTACLES & EQUIPMENT W/ OWNER PRIOR TO INSTALL. NOTIFY ENG. OF ANY DISCREPANCIES. LEGEND GENERAL NOTES (BASED ON NEC 2008) 1. ALL 125 -VOLT, SINGLE - PHASE, 15 AND 20 AMPERE RECEPTACLES INSTALLED AT DWELLING UNITS LOCATION'S, AS SPECIFIED IN THE NEC 210.8(A), SHALL BE GFCI PROTECTED. 2. ALL 125 -VOLT, SINGLE - PHASE, 15 AND 20 AMPERE RECEPTACLES INSTALLED AT DWELLING UNITS LOCATION'S, AS SPECIFIED IN THE NEC 210.52, SHALL BE LISTED TAMPER- RESISTANT RECEPTACLES AS PER NEC 406 -11. 3. ALL 125 AND 250 VOLT, 15 AND 20 AMPERE NON LOCKING RECEPTACLES INSTALLED AT DWELLING UNITS IN DAMP OR WET LOCATION'S, AS SPECIFIED IN THE NEC 406.8(A)(B), SHALL BE A LISTED WEATHER-RESI STAN TYPE. 3. ALL 120 VOLT, SINGLE PHASE, 15 AND 20 AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED IN DWELLING UNITS FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILIR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED ARC -FAULT CIRCUIT INTERRUPTER, COMBINATION TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT AS PER NEC 210.12(A)(B). ELECTRICAL SYMBOL LEGEND CDWELLING UNITS) (b) GENERAL LOADS: LOAD (VA) (1) 1500 VA X 2 SMALL APPLIANCES CIRCUITS: 3,000 VA (2A) 3VA -SF X 2,139 SF FOR GENERAL LIGHTING: 6,417 VA (213) 3VA -SF X 827 SF FOR GENERAL LIGHTING: 2,481 VA * (3) DRYER 5,000 VA ABBREVATIONS I I QUADRUPLE (DOUBLE DUPLEX) © DOOR BELL 1,000 VA GFCI GROUND -FAULT CIRCUIT - INTERRUPTER 720 VA DUPLEX OUTLET FO-1 DOOR BELL PUSH BUTTON 720 VA AFCI ARC -FAULT CIRCUIT INTERRUPTER 720 VA ISOLATED GROUND OUTLET 6,500 VA DOUBLE OVEN 9,000 VA AFF ABOVE FINISH FLOOR 1,000 VA DUPLEX 120 V 120V SMOKE ALARM (EQUAL TO KIDDE MODEL 720 VA WP WEATHER PROOF 4,500 VA ISOLATED GROUND QUADRUPLE OUTLET SD P12000) CONNECTED TO LINE SIDE OF LOCAL U/C INSTALLED UNDER COUNTER CU-1/ FCU -1: 3,570 VA -- VA CIRCUIT. ALL SMOKE ALARMS SHALL BE INTERCONNECTED. I/C INSTALLED IN ATTIC SPACE HALF SVITCHABLE DUPLEX OULET 14,540 VA (b) GENERAL LOADS: VA SCR MINIMUM AIC OF BREAKER IN PANEL AND 10,000 VA SINGLE OUTLET (GROUNDING) 12 V CS 120V COMBINATION CARBON MONOXIDE / SMOKE ALARM (EQUAL TO KIDDE MODEL KN- COSM -IB) 14,540 VA PANEL BRAZING ER EXISTING TO BE REPLACED. 39,451 VA SPECIAL PURPOSE (120/240: L,L,N, & GND) 164.4 AMPS. CONNECTED TO LINE SIDE OF LOCAL CIRCUIT, N NEW �} FLOOR BOX AS MANUFACTURED BY RG MODEL BIG 2' OR EQUAL, AND SHALL BE INTERCONNECTED WITH SMOKE ALARMS. RE EXISTING TO BE REMOVED. UNLESS NOTED. E EXISTING. O JUNCTION BOX O ELECTRICAL PANEL INSTALLATION NOTES G.F.I. DUPLEX OUTLET 11111111 FLEXIBLE CONDUIT A) MOUNT WIRING DEVICES CENTER LINE 0 HEIGHT ABOVE FINISHED FLOOR INDICATED BELLOW, IN ABOVE - COUNTER DUPLEX RECEPTACLE — CONDUIT RUN EXPOSED ALL UNITS: ABOVE - COUNTER G.F.I. DUPLEX RECEPTACLE — CONDUIT CONCEALED IN WALLS OR OVERHEAD (SHOWN WITH TWO HOT & NEUTRAL) A) RECEPTACLES: @ 18" B) LIGHT SWITCHES: 0 46" [�] ® TV OUTLET — 4 — CONDUIT IN OR UNDER THE SLAB ", (SHOWN WITH HOT, NEUTRAL & GROUND) C) TELEPHONE JACKS: KITCHEN 0 42 ALL OTHRES 0 18" TELEPHONE OUTLET D) THERMOSTATS: 0 46' 1x4 FLUORESCENT LIGHT FIXTURE ® © DATA OUTLET B) BATHROOM WALL MOUNTED FIXTURES: 6" OVER THE CENTER LINE OF THE Q COMMUNICATION & DATA STRUCTURAL OUTLET MIRROR OR AS SHOWN IN THE ARCHITECTURAL DRAWINGS. COMBINATION. 20 FLUORESCENT LIGHT FIXTURE C) LIGHT SCONCES TO BE MOUNTED 0 6' -6" A.F.F. OR AS SHOWN IN IN THE ARCHITECTURAL DRAWINGS. SCONCES MOUNTED BELOW 6' -6" SHALL S SINGLE POLE SWITCH NOT PROTUDE NOT MORE THAT 4" INTO WALKWAYS, HALLS, CORRIDORS, S3 THREE WAY'.SWITCH 2x2 FLUORESCENT LIGHT FIXTURE OR AISLES. COORDINATE WITH ARCHITECTURAL ELEVATIONS. S4 FOUR WAY SWITCH LEGEND GENERAL NOTES (BASED ON NEC 2008) or Se SERVICE BREAKER (FACTORY INSTALLED) E) 4' FLUORESCENT LIGHT STRIP 1. ALL 125 -VOLT, SINGLE - PHASE, 15 AND 20 AMPERE RECEPTACLES CEILING FAN CONTROL SWITCH COMBINATION 0 SURFACE MTD. FLUORESCENT LIGHT FIXTURE INSTALLED AT DWELLING UNITS LOCATION'S, AS SPECIFIED IN THE NEC 210.8(A), SHALL BE GFCI PROTECTED. SD DIMMER SWITCH -C SURFACE FLUORESCENT, UNLESS NOTED 2, ALL 125 -VOLT, SINGLE - PHASE, 15 AND 20 AMPERE RECEPTACLES LOW VOLTAGE TRANSFORMER PENDANT LIGHT FIXTURE INSTALLED AT DWELLING UNITS LOCATION'S, AS SPECIFIED IN THE P NEC 210.52, SHALL BE LISTED TAMPER - RESISTANT RECEPTACLES E(ij EXHAUST FAN 0 RECESS HI -HAT LIGHT FUXTURE AS PER NEC 406 -11. MOTOR WALL WASH LIGHT FIXTURE 3. ALL 125 AND 250 VOLT, 15 AND 20 AMPERE NON LOCKING �T-� � l RECEPTACLES INSTALLED AT DWELLING UNITS IN DAMP OR WET ® STARTER OR CONTROL PANEL WALL MOUNTED LIGHT FIXTURE LOCATION'S, AS SPECIFIED IN THE NEC 406.8(A)(B), 9 COMBINATION STARTER ® STEP LIGHT FIXTURE SHALL BE A LISTED WEATHER- RESISTAN TYPE. EY DISCONNECT SWITCH - WP INDICATES WEATHERPROOF (TYP.) 3. ALL 120 VOLT, SINGLE PHASE, 15 AND 20 AMPERE BRANCH � 0� CEILING FAN CIRCUITS SUPPLYING OUTLETS INSTALLED IN DWELLING UNITS 340 DISCONNECT SIZE (3 DENOTESMO. POLES, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, 60 DENOTES DISCONNECT RATED AMPERAGE, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, 40 DENOTES.FUSE SIZE [NF DENOTES NON- FUSED] CLOSETS, HALLWAYS, OR SIMILIR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED ARC -FAULT CIRCUIT INTERRUPTER, COMBINATION TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT AS PER NEC 210.12(A)(B). A I CONSTRUCTION NOTES: 1. ALTERATIONS TO EXISTING WORK BEING OF SUCH NATURE THAT ALL FACETS OF THE WORK ARE IMPOSSIBLE TO DETAIL AND SPECIFY. IT IS THEREFORE THE RESPONSIBILITY OF THE CONTRACTOR TO CARE- FULLY EXAMINE THE BUILDING AND THE GROUNDS AND FAMILIARIZE HIMSELF WITH THE CONDITIONS AND RELATE THESE CONDITIONS TO THE SCOPE OF THE PROPOSED WORK PRIOR TO BIDDING. 2. ANY EXISTING INSTALLATION PROBLEMS OR EXISTING CODE VIOLATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT /ENGINEER PRIOR TO BIDDING. 3. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE OWNER ALL THE CONSTRUCTION WORK AND NOTIFY HIM 72 HOURS IN ADVANCE OF COMMENCING ANY WORK. 4. ANY ELECTRICAL WORK WHICH WILL INTERFERE WITH THE RESIDENTS NORMAL OPERATION SHALL BE NOTIFIED IN ADVANCE TO THE OWNER AND THE HOURS AND DAYS OF THE WEEK TO DO THE WORK SHALL BE APPROVED BY HIM. 5. COORDINATE LOCATIONS OF ALL LIGHTING, RECEPTACLES & EQUIPMENT W/ OWNER PRIOR TO INSTALL. NOTIFY ENG. OF ANY DISCREPANCIES. LEGEND GENERAL NOTES (BASED ON NEC 2008) 1. ALL 125 -VOLT, SINGLE - PHASE, 15 AND 20 AMPERE RECEPTACLES INSTALLED AT DWELLING UNITS LOCATION'S, AS SPECIFIED IN THE NEC 210.8(A), SHALL BE GFCI PROTECTED. 2. ALL 125 -VOLT, SINGLE - PHASE, 15 AND 20 AMPERE RECEPTACLES INSTALLED AT DWELLING UNITS LOCATION'S, AS SPECIFIED IN THE NEC 210.52, SHALL BE LISTED TAMPER- RESISTANT RECEPTACLES AS PER NEC 406 -11. 3. ALL 125 AND 250 VOLT, 15 AND 20 AMPERE NON LOCKING RECEPTACLES INSTALLED AT DWELLING UNITS IN DAMP OR WET LOCATION'S, AS SPECIFIED IN THE NEC 406.8(A)(B), SHALL BE A LISTED WEATHER-RESI STAN TYPE. 3. ALL 120 VOLT, SINGLE PHASE, 15 AND 20 AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED IN DWELLING UNITS FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILIR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED ARC -FAULT CIRCUIT INTERRUPTER, COMBINATION TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT AS PER NEC 210.12(A)(B). SERVICE FEEDER LOAD STUDY: ';FRMC.'F LOAD STUDY (N.E.C. 220 -30. OPTIONAL CALCULATION- DWELLING UNIT.) (b) GENERAL LOADS: LOAD (VA) (1) 1500 VA X 2 SMALL APPLIANCES CIRCUITS: 3,000 VA (2A) 3VA -SF X 2,139 SF FOR GENERAL LIGHTING: 6,417 VA (213) 3VA -SF X 827 SF FOR GENERAL LIGHTING: 2,481 VA * (3) DRYER 5,000 VA REFRIGERATOR I I '7 1,500 VA FREEZER 1,000 VA SERVICE FEEDER LOAD STUDY: ';FRMC.'F LOAD STUDY (N.E.C. 220 -30. OPTIONAL CALCULATION- DWELLING UNIT.) (b) GENERAL LOADS: LOAD (VA) (1) 1500 VA X 2 SMALL APPLIANCES CIRCUITS: 3,000 VA (2A) 3VA -SF X 2,139 SF FOR GENERAL LIGHTING: 6,417 VA (213) 3VA -SF X 827 SF FOR GENERAL LIGHTING: 2,481 VA * (3) DRYER 5,000 VA REFRIGERATOR 1,000 VA DISHWASHER 1,500 VA FREEZER 1,000 VA SECURITY SYSTEM 720 VA WASHER 1,500 VA DISPOSAL 720 VA RANGE HOOD 720 VA COOKTOP 6,500 VA DOUBLE OVEN 9,000 VA MISC. LOADS 1,000 VA (4) IRRIGATION PUMP. 1,500 VA GARAGE DOOR 720 VA EWH # 1 4,500 VA TOTAL 47,278 VA (c) HEATING AND AIR CONDITIONING LOADS: 100 % COOLING 100% HEATING CU-1/ FCU -1: 3,570 VA -- VA EXIST. CU/ FCU: -- VA 10,970 VA SUBTOTAL: 3,570 VA 10,970 VA 100 % OF LARGER LOAD: 14,540 VA (b) GENERAL LOADS: VA FIRST 10,000 VA @ 100 % : 10,000 VA BALANCE 37,278 VA @ 40 %: 14,911 VA (C) AC LOAD: 14,540 VA @ 100% 14,540 VA TOTAL 39,451 VA 39,451 VA @ 120/240 V, 14, 3W, = 164.4 AMPS. GENERAL NOTES 1- GENERAL CONDITIONS: THE GENERAL CONDITIONS FORM A PART OF THE SPECIFICATIONS FOR THIS TRADE. EACH SUB - CONTRACTOR MUST READ GENERAL CONDITIONS, AS WELL AS THE SPECIFICATIONS FOR WORK OF OTHER TRADES AND TO ASCERTAIN WHAT WORK AND MATERIALS HE MUST SUPPLY TO THE OTHER CONTRACTORS. 2- SITE INVESTIGATION: IT SHALL BE THE RESPONSABILITY OF BIDDERS TO VISIT THE SITE AND TO ACQUAINT THEMSELVES WITH AL INFORMATION REGARDING THE NEW BUILDING. 3- DESIGN: THE INSTALLATION OF THE WIRING SYSTEM SHOWN ON THESE DWGS. SHALL CONFORM TO THE REGULATIONS OF LOCAL CODES AND ORDINANCES, N.E.C. AND LOCAL UTILITY COMPANIES. 4- MINIMUM STANDARDS: THE MATERIAL, INSTALLATIONS AND WORKMANSHIP FURNISHED UNDER THIS SECTION SHALL CONFORM TO THE REQUIREMENTS OF LOCAL CODES AND N.E.G., ALL MATERIALS USED SHALL BE LISTED OR BEAR U.L. APPROVAL. 5- GUARANTEE: THIS SUB - CONTRACTOR SHALL FURNISH A WRITTEN GUARANTEE THAT ALL WORK EXECUTED UNDER THIS CONTRACT, SHALL BE FREE FROM DEFECTS OR WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR, AT CONTRACTOR'S EXPENSE, REPAIR AND REPLACE ALL WORK WHICH BECOMES DEFECTIVE DURING THE TIME OF THE GUARANTEE. 6- RACEWAYS AND FITTINGS: a) RIGID GALVANIZED : 1 -1/2" OR LARGER , AND IN SLAB ABOVE GRADE. b PVC : IN OR UNDER GND FLOOR SLAB , OR UNDERGROUND ONLY . c EMT : ALL OTHER LOCATION, (WITH COMPRESSION COUPLING FOR DAMP LOCATION). FITTING: TO MATCH THE APPROVED USED RACEWAY. 7- CONDUCTORS: THE MINIMUM CONDUCTOR NO. 14 SOLID CU. TYPE "THWW INSULATION, NO MORE THAN THREE CURRENT- CARRYING CONDUCTORS SHALL BE INSTALLED IN A RACEWAY, ALUMINUM CONDUCTOR ALLOWED ONLY WHERE INDICATED ON DRAWINGS. 8 ALL EQUIPMENT LISTED ON DWGS. BY CATALOG NO. SHALL BE LIMITED TO THE KIND AND MANUFACTURE LISTED. NO SUBSTITUTION SHALL BE ALLOWED UNLESS APPROVED BY THE ENGINEER. A WRITTEN GUARANTEE OF THREE YEARS AND CREDIT FROM BASIC BID SHALL BE SUBMITTED WITH SHOP DRAWINGS. 9- CONTRACTOR TO INSTALL AND /OR CONNECT ALL EQUIPMENTS AND CONTROLS SUPPLIED BY OWNER, OR ANY OTHER TRADE. SEE OTHER TRADES DRAWINGS AND SPECIFICATIONS. 10- ALL FEEDERS AND BREAKERS SHALL BE COORDINATED WITH EQUIPMENT'S PLATE AT SITE. 1'? 1 1:J n� 17, 0 WRI 'A L J N F 01 D JOB NO. 12 -033 RPJ, Inc. STATE OF FL CO. N0. (00006813) P.E. N0. (16398) A 4977 S.W. 74th COURT ,ANNIVERSARY MIAMI, FL. 33155 V PHONE: (305) 666 -2131 FAX: (305) 666 -0131 E —Moil: rpjmep0bellsouth.net I I 1A I 1 I a a =r =a O 3, s� 4 z - i�