12-591-023
I I 1 G I J I 14 1 :J I p 1 / 1 O I I 1 l.J I 11 I l G N M L J N i I F D C A HVAC NOTES 1. GENERAL A. ALL WORK SHALL BE DONE in accordance with the Florida Building Code and with all applicable regulations. B. DRAWINGS: Refer to all drawings for coordination of the HVAC work. C. ARRANGE AND PAY for all permits licenses, inspections and tests. Obtain the required certificates and present to owner. D. GUARANTEE: The completed installation shall be fully guaranteed against defective materials and /or improper workmanship for a minimum of one year for material and labor. Compressors shall be guranteed for a period of five years, E. As built drawings shall be submitted to owner at the completion of project. 2. SHOP DRAWINGS: Contractors shall submit for approval, within 30 days after signing contract, a minimum of five copies of fully descriptive literature, including but not limited to: fans, air conditioning units, air outlets. No work shall proceed without approval of these submittals. 3. DESIGN PARAMETERS: A. Outdoor design temperature (Summer): 917 DB and 797 WB B. Outdoor design temperature (Winter): 457 C. Indoor design temperature (Summer): 787 DB D. Indoor design temperature (Winter): 727E DB 4. ALL THERMOSTATS SHALL have heating mode maximum setting of 75 F, and cooling mode minimum setting of 70 F. The thermostat shall be arranged to prevent the simultaneous operation of heating and cooling, 5. ELECTRICAL CONTROLS AND POWER WIRING: Under electrical contract. 6. EQUIPMENT SPECIFIED BY manufacturer's number shall include all accessories, controls, etc., listed in the catalog as standard with the equipment. Optional or additional accessories shall be furnished as specified. 7, MATERIALS: A. REFRIGERANT PIPING: Shall be type L soft drawn, copper tubing, dehydrated for refrigerant use. Sized as shown on drawings or as per air conditioning equipment manufacturer's recommendations. B. INSULATION: Refrigerant suction piping shall be insulated with 1/2" thick foamed plastic insulation, fire retardant type. Insulation shall be installed in piping before assembly. No split insulation will be acceptable. Seal joints with manufacturer's approved adhesive and grey tape. C. DUCTWORK: a. All supply air ductwork shall be fiberglass ductboard, fabricated and installed as per latest edition of SMACNA "Fibrous Glass Duct Manual ". 1 -1/2" thick R -6.0 in uncond. space. b. All exhaust ductwork shall be galvanized sheet metal duct not lighter than 26 gage. c. All duct dimensions are clear inside dimensions. d. Flexible insulated ductwork with 1 1/2" thick fiberglass insulation with FRK vapor barrier, class I air duct, U.L. R -6.0 MIN. 8. Provide metal round fittings with scoop at all flexible duct connection to supply duct. 9. TEST AND BALANCE: Contractor shall test and balance all ventilation and air conditioning systems. Submit four copies of Test and Balance Report to owner for approval. 10. CONTROLS: Air Conditioning units shall be started and stopped thru individual thermostat. Individual thermostats shall start /stop supply fans and activate cooling /heating systems as selected. 11. Mechanical plans in general, are diagrammatic in nature, and are to be read in conjuction with arch. Plumbing, electrical and structural plans and shall be considered as one set of documents. Duct and piping offsets, bends and transitions will be required to provide and install a complete functional system and shall be provided by the contractor at no additional cost to the owner. 12. Contractor shall verify job conditions prior to ordering, fabrication or installation of materials or equipment. Notify architect /engineer of any conflicts before fabrication. 13. Ducts shall be tested by a Class 1 certified rater for max leakage indicated on energy calculations as per FBC Mechanical 2007. I N MECHANICAL DETAILS, SCHEDULES AND NOTES LL;� SCALE• NM MINI SPLIT AC UNIT SCHEDULE UNIT DESIGNATION UNIT DESIGNATION FCU -1 TOILET AREA SERVED LIVING ROOM LOCATION LOCATION CEILING MOUNTED CLG. BLOWER OPERATING WEIGHT, LBS 50 .� DESIGN MANUFACTURER MITSUBISHI Z MODEL NUMBER PLA -A18BA CENTRIFUGAL TOTAL AIR, CFM 500 o EXTERNAL STATIC PRESSURE, IN OF WATER 0.5 0 0 FAN MOTOR AMPS. (NON- OVERLOAD) 0.76 Z DIMENSIONS W X H X D 33 X 10 X 33 Z FACE VELOCITY - FPM -- WALL SWITCH DESIGN AIR ACROSS COIL, CFM. 500 v UJ GRAND TOTAL COOLING CAPACITY, BTU /HR 18,000 '" TOTAL SENSIBLE COOLING CAPACITY, BTU /HR 14,580 Z a TOTAL INPUT IN COOLING MODE, WATTS 690 ``' ENTERING AIR TEMP., F DB /WB 80/67 MODEL NUMBER FILTER THICKNESS TYPE 1" / WASHABLE SERVICE SWITCH GRAND TOTAL HEATING CAPACITY, BTU HR 19 000 SMOKE DETECTOR ( U.L. APPROVED) TOTAL INPUT IN HEAT MODE WATTS REVERSE CYCLE 1M0 FIRE DAMPER UNIT DESIGNATION CU -1 CONSTRUCTION DESIGN MANUFACTURER MODEL NUMBER MITSUBISHI PUZ- A18NHA o SEER / HSPF 14.2 / 9.8 BIRDSCREEN DIMENSIONS (W X H X D) 32 X 21 X 11 o WEIGHT, LBS 100 THERMOSTAT CONTROL ELECTRICAL SERVICE 240 -1 -60 Z MCA MOCP 13.0 15.0 z TYPE OF FAN PROPELLER C5 Z N0, OF FANS AND AMPS 1 0.96 o AMBIENT AIR TEMP. "F DB 95 o CONDENSING TEMP. F DB -- ® NO. OF COMPRESSORS TYPE 1 ROTARY o COMPRESSORS F.L.A./L.R.A. EACH 12.0 14.0 OC CAPACITY REDUCTION. 0 -50 -100% a: MAX NUMBER OF CONNECTABLE INDOOR UNITS 1 a REFRIGERANT TYPE R -410A REFRIGERANT PIPE SIZE, SUCTION IN, OD 1/4- REFRIGERANT PIPE SIZE LIQUID IN OD 1/2" NOTES: 1. INDOOR UNITS RECEIVE POWER FROM OUTDOOR UNIT THROUGH FIELD- SUPPUED INTERCONNECTED WIRING. 2, HEATING MODE IS ESTABLISHED BY HEAT PUMP FUNCTION, 3. THERMOSTAT TO BE OF THE STATIONARY TYPE. 4. FCU IS EQUIPT WITH CD PUMP. VENTILATION FAN SCHEDULE UNIT DESIGNATION EF -2 AREA SERVED TOILET OPERATING WEIGHT, LBS 17 LOCATION CEILING FAN TYPE CLG. BLOWER X TOTAL AIR, CFM 80 X DRIVE TYPE DIRECT X FAN WHEEL TYPE CENTRIFUGAL X FAN TIP SPEED, FPM MAX. - -- X FAN SPEED, RPM 716 Z a TOTAL STATIC PRESSURE, IN OF WATER 0.1 wL FAN MOTOR HP. (NON - OVERLOAD) 22.8 WATTS FAN MOTOR STARTER TYPE WALL SWITCH STARTER FURNISHED BY MC ELECTRICAL SERVICE AVAILABLE 120 -1 -60 MASONARY OPENING REQUIRED - -- ZONES 0.6 DESIGN MANUFACTURER PANASONIC MODEL NUMBER FV -08VQ3 o SERVICE SWITCH YES SMOKE DETECTOR ( U.L. APPROVED) NO FIRE DAMPER - -- w CONSTRUCTION ALUM /PLASTIC X MULTIBLADE BACKDRAFT DAMPER YES Ln w BIRDSCREEN NO 0 0 SOLID STATE SPEED CONTROL NO THERMOSTAT CONTROL NO FACTORY FABRICATED CURB NO FILTER AND FILTER FRAME NO HVAC DESIGN REQUIRES: YES NO DUCT SMOKE DETECTOR - X FIRE DAMPER(S) - X SMOKE DAMPER(S) - X FIRE RATED ENCLOSURE - X FIRE RATED ROOF/FLOOR CEILING ASSEMBLY _ X FIRE STOPPING - X SMOKE CONTROL - X CONDENSING UNIT 6 MIN. ----t FASTEN C.U. TO CONCRETE PAD USING (4) 1/4" CONCRETE POWER TI CONTROL SCREWS WITH 1.5" EMBEDMENT CONNECTIONS MINIMUM AS PER MFG. CERTIFIED 6" MIN. DATA. PROVIDE (4) 1/2' ISOMODE PADS AT EACH SCREW O 4" MIN. ° '• . - ° LIQUID LINE CONCRETE BASE W/ ,/ W/0 INSULATION 6x6- 10 /10WWF 6 "MIN. SEAL ENTRANCE OF REFRIGERANT LINES INTO P.V.C. PIPE W/ IMPERMEABLE, RESILENT MATERIAL NOTE: CONCRETE SREWS SHALL BE RATED FOR 500 LBS. MIN. PULL -OUT CAPACITY, SUCTION LINE W/ 1/2" ARMAFLEX INSULATION & VAPOR BARRIER CONDENSING UNIT MOUNTING DETAIL N.T.S. ►E °o °o °0 11 Q °C, o ° CD Q ° O o 24" DIAMETER CONCRETE ° OR CLAY PIPE WITHOUT o v COVER FILLED WITH 3/4" CRUSHED ROCK o ° ° CONDENSATE DRAIN to LINE FROM BUILDING PLAN FOR SIZE. o °o c 4, o 0 0 0 0 CONDENSATE DRAIN DRYWELL DETAIL N.T.S. 1 10 1 I/+ I 5TRAP HANGER5 -- HANGER STRAPS &V MAX. UNLESS FOOT OF STRAP 15 PLACED UNDER A BOTTOM REINFORCEMENT, Z MINIMUM SCREWS SCHEWS MAY BE OMITTED IF HANGER LOOPS DUCT HANGER DETAIL N.T.S. JOB N0. 12 -033 �- RPJ, Inc. STATE OF FL CO. N0. (00006553) P.E. N0. (16395) I" 4977 S.W. 74th COURT MIAMI, FL. 33155 PHONE: (305) 666 -2131 FAX: (305) 666 -0131 . E -Moil; rpoepfbellsouth.net A 1� I I A � rt M L K ,i N D B A U) m U) 0 D) LU zs ®1111M©0M®0W co UJ Z xl U o a Al /k r a , titer AZZE ARCHT� CTUR„E 7194 SW 47th Street M11-4 Florida SM55 AA2000 6" Tel (805) 28866 688 -2888 W_ 0 W c Z Z Q DRAWN BY: y.� n WJ AM 05 -08 -12 PROJECT NO. SCALE: 12467 AS a o cv 4, 10 43 co � 0 h .o W 41 0 0 10 0 _o w Cq C 4 Q� o • a 0 Z 4 Z FTT I I I I 1 O U) m U) 0 D) LU zs ®1111M©0M®0W LLJ Z Z J LL co UJ Z U o a z if,VJ L a W_ W c Z VJ Z Q DRAWN BY: ISSUE DATE: AM 05 -08 -12 PROJECT NO. SCALE: 12467 AS ARCHITECT OR ENGINEEMS LLJ Z Z J LL