Loading...
12-625-018CIRCUIT C -10 WIRE 12 BRKR 20 AMP SMOKE DETECTOR_)_ / `.KITCHEN OR 120V BATHROOM LIGHT SWITCH PHASE CONDUCTOR SMOKE DETECTOR CONNECTION DETAIL N.T.S. OVERHEAD "FP &L" SERVICE SELECT LARGER NON CONCURRENT A/C LOAD: 8,100VA NEW 3 ,�.� MCM THWN (CU) & (1) #8 THWN GROUND NEW 3 ,350 THWN (CU) IN 1-114" --1 /4 " CONDUIT, IN 2-- -112" CONDUIT. NEW METER /MAW COMBO 300 Amp 1201240,10 300 -TI EXIST I NEW lI PANEL I PANEL OM 150A 100A 120 240 120 240 1013W I 10/3W WP !L- .,.__ -J j WP WP NEW 3 J1 /0 MCM THWN (CU) & (1) , 6 THWN GROUND NEW (1) J2 IN 1 -112" CONDUIT. i TO C.W.P HOUSE ADDITION , TO FOUNDATION----- -EF - - - - -- EXISTING RODS ELECTRICAL RISER DIAGRAM NIS WP - - - - - -�-�/ i Y / i B 8- 8 -6 -10 - - / -- - - - - -- B -10 i TO EXI S T LICHTS CKT / �' - -- -, / �, ,1 1 T NEW - / _ METERIMAIN _ - - - - - - -- -� r EXISTING (D _1J :{ j / / / / / / , PNL. A i - / / / ✓ / / // /'' / /' /' ��,/ / NEW NEW B -0 A. H. U. PNL. 'B' I B -101 / f i i / 1 - - - -- - - - -_..l i % 1 i7� i ,- B 57 r / • , / a; / / r ✓' / B-5,7 T ' I B-- 10 - J i B-10 -- - / / / ��" �- S / � B �' B -10 r ; I rt _8 : ' 10 7 _. ._�.___._... /_ B 8 - -/ -_ r `y ELECTRICAL FLOOR PLAN B -B 2, 4; g SCALE: 1 /4" - 1 ' 0" A/C CALCULATIONS 240V-10 CENTRAL AICJ2 COMPRESSOR: 10.2 AMP HEATER. 7,500 VA CONDENSER FAN: .75 AMP EVAP. BLOWER: 2.5 AMP EVAP, BLOWER: 2,5 A x 240 V = 600 VA 13.45 AMP TOTAL VA = 13.45 A x 240 V = 3,228 VA TOTAL HEATER = 8,100 VA PHASE: 10 NEW METER /MAIN COMBO NEW PANEL "En MAKE: SIEMENS VOLTAGE: 1201240 v VOLTAGE: 1201240 v 4W"J 6262 TYPE: MC0812BI35ORLTM PANEL AMPS: 300 Amps TYPE: G1224L1100CU PANEL AMPS: 100 Amps one 30 Fox 30 A Ckt (BRANCH BREAKERS TYPE QP, 10KAIC) MAIN BREAKER: NONE BKR Ckt USE SPEC VOLT BKR WIRE COND VA PH VA COND WIRE BKR VOLT SPEC USE Ckt' A B No. SIZE A AMP AWG SIZE AWG AMP SIZE AWG AMP No. 1 EXISTING PANEL "A" No. 1 A.H.U. #1 ** 1/0 240 40 8 1 2 8,100- I.-IA 3 2,628 3 4 10 25 240 NCL C. U. 1 ** 2 - 4 5 EXISTING JACUZZI 5 TANKLESS WATER HEATER ** EXIST 240 60 6 1 12,000 •+++ EXIST 360 * 1 2 12 20 120 7 GENERAL do OUTDOOR RECEPTACLES 6 7 1� - * 1 2 12 20 120 9 GENERAL RECEPTACLES 8 9 BATHROOM RECEPTACLE GFI 120 20 12 112 * 200 * 112 12 20 120 11 GENERAL do OUTDOOR LIGHTS 10 11 1 BATHROOM RECEPTACLE GO 120 20 12 12 13 OUTDOOR RECEPTACLES 12 13 20 EXIST EXIST 1,500 .112 • 14 15 14 151 16 * SEE Load CALCULATION _ 16 * SEE Load CALCULATION Load Calculation: VERIFY NAME PLATE ** VERIFY NAME PLATE Lighting 808 sqf x 3 va/sgf = 2,427 vo GFI = GROUND FAULT INTERRUPTER. GFI = GROUND FAULT INTERRUPTER. GENERAL LOAD CALCULATION. Small Appliconces - 0 va As per N.E.0 Art, 720.30 Section B. Laundry = 0 vo RM - ROMEX = ROMEX Appliances = 12,000 vo Outdoor Lights /receptacles 560 va LIGHTS, S.A & LAUNDRY LOAD A/c Load = 8,100 va GENERAL LIGHTING (S.F. X W /.F) =2,343 x 3 = 7,029 VA Total VA = 8,100 ve SMALL APPLIANCE CIRCUITS = 2 x 1,500 VA = 3,000 VA Panel Load - 23,0871240 96 Amps LAUNDRY CIRCUITS = 1,500 VA PHASE: 10 NEW METER /MAIN COMBO MAKE: SIEMENS VOLTAGE: 1201240 v 4W"J 6262 TYPE: MC0812BI35ORLTM PANEL AMPS: 300 Amps (BRANCH BREAKERS TYPE OP, 10KAIC) MAIN BREAKER: 300 one 30 Fox 30 A Ckt USE SPEC VOLT BKR WIRE COND VA PH VA COND WIRE BKR VOLT SPEC USE - - -- - Ckt No. AMP AWG SIZE A B SIZE AWG AMP No. 1 EXISTING PANEL "A" 240 150 1/0 I -1 2 33,120 23,087 I.-IA 3 100 240 NE W PANEL "B 2 3 J - 4 5 EXISTING JACUZZI 240 50 EXIST EXIST 9,000 r 9,000 EXIST EXIST 50 240 EXIST' R. V. OUTLET 6 7 - J J 8 9 OUTDOOR RECEPTACLES 120 20 EXIST EXIST 1,500 10 11 OUTDOOR RECEPTACLES 120 20 EXIST EXIST 11 500 12 13 OUTDOOR RECEPTACLES 120 20 EXIST EXIST 1,500 14 15 16 * SEE Load CALCULATION ** VERIFY NAME PLATE GFI = GROUND FAULT INTERRUPTER. GENERAL LOAD CALCULATION. As per N.E.0 Art, 720.30 Section B. RM = ROMEX LIGHTS, S.A & LAUNDRY LOAD GENERAL LIGHTING (S.F. X W /.F) =2,343 x 3 = 7,029 VA SMALL APPLIANCE CIRCUITS = 2 x 1,500 VA = 3,000 VA LAUNDRY CIRCUITS = 1,500 VA OTHER LOADS- LIGHT, SA & LAUNDRY SUBTOTAL = 11,529 VA OTHER LOADS = 72,200 VA SUBTOTAL = 83,729 VA FIRST 10,000 va @ 100%. = 10,000 VA REST 73,729 va @ 407 = 29,491 VA SUBTOTAL - 39,491 VA TOTAL A/C LOAD - 16,200 VA TOTAL VA = 55,691 VA /240 = 232 AMPS Addition to.; ... ••.. Sergio Tejeda Res. 5729 S.W. 60 Avenue, Miami) FL. Professional of Record: Norman Blandon F' Discipline) teure Re istrotior 'No.' ` AR -.00 D 0 #. R r_ �� 4110 W 40 St. Suite 2A iami Flor a 33155 4W"J 6262 Florida License one 30 Fox 30 A 666 -5151 666 -7581 0003242 This drawing and /or specification is /are provided as an instrument of service by N25 Architecture Co. and is /are intended for use on this project only. This drawing remains the property of N25 Architecture Co. and shall be returned upon determination of intent. All drawings, specifications, designs, models, and arrangements appearing herein constitute the original and unpublished work of N25 Architecture Co. Any reproduction, use, or disclosure of the proprietary information contained herein without the prior consent of N25 Architecture Co. is strictly prohibited. Sheet Title: ELECTRICAL FLOOR PLAN Issue Date: Project No. June 8, 2012 Drawing No.: E2000 Professional of Record: Norman Blandon F' Discipline) teure Re istrotior 'No.' ` AR -.00 D 0 #. R r_ ��