Loading...
12-625-017NOTES 1.- AC SHALL HAVE BUILT -IN BREAKER. 2.- ALL SINGLE STATION SMOKE DETECTOR WITHIN THE HOUSE SHALL_ BE INTERCONNECTED AS PER NFPA 72 ART. 8- 1.4.1.6 3.- ALL SINGLE STATION SMOKE DETECTOR SHALL BE POWERED BY 120V POWER AND SHALL BE CONNECTED TO BRANCH CIRCUIT AHEAD OF ANY SWITCH. 4.- ALL SINGLE STATION SMOKE DETECTOR SHALL HAVE BATTERY BACK -UP. 5.- ALL SINGLE STATION SMOKE DETECTORS SHALL BE INSTALLED MIN 3' FROM ANY A/C REGISTER. CONTRACTOR TO VERIFY IN FIELD. 6.-- COORDINATE EXACT LOCATION OF ALL DEVICES WITH ARCH /OWNER. 7.- HANGING FIXTURES & FANS MUST BE SUPPORTED AS PER NEC 314- 27DI422 -18. 8.- JACUZZI SHALL HAVE AN ACCESS PLATE OR COVER AS PER NEC 680 -73. MIN SIZE 20 "W x 15 "H. ALL METAL PIPING SYSTEM, METAL PARTS OF ELECTRIC EQUIPMENTS, AND PUMP MOTORS ASSOCIATED WITH THE JACUZZI SHALL BE BONDED TOGETHER WITH A COPPER BONDING JUMPER, INSULATED, COVERED, OR BARE, NOT SMALLER THAN �B AWG SOLID, AS PER NEC 680 -74. 9.- FIXTURES LOCATED IN WET LOCATIONS SHALL BE LISTED FOR THAT PURPOSE. 10.- CONTRACTOR TO PROVIDE PANEL SCHEDULE AT EACH PANEL INDICATING ALL CKTS CONNECTED. 11.- CONTRACTOR SHALL LABEL PANELS AND DISCONNECT EX: PANEL "A", PANEL "A" DISCONNECT ETC. 12.- FIXTURES WITH DIRECT CONTACT W /INSULATION MUST BE RATED IC AS PER NEC 410 ---65 (C). 13. -ALL FLUORESCENT FIXTURES MUST BE ENERGY EFFICIENT. ALL CEILING FIXTURES MUST HAVE AN IN LINE FUSE (THERMAL PROTECTOR). 14. -ALL LIGHTING FIXTURES MUST BE LISTED BY A NATIONAL RECOGNIZED TESTING LABORATORY (UL) NOTE ---1: ALL 120 -VOLT, SINGLE- PHASE, 15--- AND 20- AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS INSTALLED IN DWELLING UNIT FAMILY ROOMS, DINING ROOMS, LIVING ROOMS,PARLORS, LIBRARIES, DENS, BEDROOMS, SUN ROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOM OR AREAS SHALL BE PROTECTED BY A LISTED ARC FAULT CIRCUITINTERRUPTER, COMBINATION -TYPE, INSTALLED TO PROVIDE PROTECTION OF THE BRANCH CIRCUIT. (2008 NEC. 210.128 NOTE-2: IN ALL AREAS SPECIFIED IN NOTE ---1, ALL 125 -VOLT, 15 AND 20 AMPERE RECEPTACLES SHALL BE LISTED TAMPER RESISTANT RECEPTACLES. ELECTRICAL LEGEND 20 A., 120., V., DUPLEX RECEPTACLE, GROUNDING TYPE, U.O.N. MOUNTED 18" A.F.F. OR AS DIRECTED BY ARCHITECT. 20A, 120V GFI DUPLEX RECEPTACLE. ® 250V SPECIAL PURPOSE RECEPTACLE. LIGHTING SWITCH @ 48" AFF. 3 -WAY LIGHTING SWITCH @ 48" AFF, SWITCH MOTOR RATE (60AMP). CJi PUSH BUTTON GARAGE OPENER, Ol SAFETY DISCONNECT SWITCH. r ELECTRIC PANEL. EXHAUST FAN. s0 SINGLE STATION SMOKE /CARBON MONOXIDE DETECTOR W/BATTE BACKUP AND INTERCONNECTED. TIE TO BATHROOM CIRCUIT. Tv TV OUTLET. 1 PHONE OUTLET. PROVIDE MUD RING AND 314 "C STUBBED ABOVE CEILING. -- SURFACE OR PENDANT MOUNTED FIXTURE. - WALL /PEDESTAL MOUNTED LIGHT. C = ABOVE THE COUNTER. WP = WEATHER PROOF. E = EXISTING TO REMAIN. ELECTRICAL GENERAL NOTES 1.- OVERALL INSTALLATION: THE INSTALLATION SHALL COMPLY WITH THE NATIONAL ELECTRICAL CODE (NEC), THE FLORIDA BUILDING CODE (FBC), AND ANY OTHER APPLICABLE FEDERAL, STATE AND LOCAL CODES. 2.- COMPLIANCE: WORKMANSHIP, MATERIALS AND INSTALLATION SHALL BE IN STRICT ACCORDANCE WITH THE APPLICABLE EDITION OF THE NEC, NFPA, NEMA, ASTM, OSHA, HRS HEALTH AGENCIES, AND OTHER APPLICABLE NATIONAL, STATE, AND LOCAL CODES AND PERTAINING REGULATIONS ESTABLISHED BY THE RULING AUTHORITY HAVING JURISDICTION. CONTRACTORS SHALL ALSO MEET THE REQUIREMENTS OF OTHER STANDARDS WHERE SUCH REQUIREMENTS ARE MORE STRICT THAN THOSE STANDARDS CITED ABOVE. 3.- MATERIALS: CONTRACTOR SHALL PROVIDE ALL NEW MATERIALS OF AMERICAN MANUFACTURE, BEARING THE UNDERWRITER'S LABORATORY (UL) LABEL AS APPLICABLE. 4.- PERMITS AND INSURANCE: CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, FEES, TAXES, INSPECTIONS, TESTS, FINES AND OTHER ITEMS AS REQUIRED FOR THE INSTALLATION OF THE COMPLETE ELECTRICAL SYSTEMS AS OUTLINED HEREIN AND SHOWN ON PLANS. CONTRACTOR SHALL PROVIDE ALL REQUIRED INSURANCE FOR PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF THE WORK. 5.- EXISTING CONDITIONS: BEFORE BIDDING, THE CONTRACTOR SHALL VISIT THE JOB SITE AND ASCERTAIN ALL EXISTING CONDITIONS WHICH WILL AFFECT HIS WORK. FAILURE TO DO SO WILL NOT BE ACCEPTED AS A REASON FOR REQUESTING EXTRA PAY WHERE THE EXISTING CONDITIONS RESULT IN EXTRA MATERIALS OR ANY EXISTING CONDITIONS FOUND BY THE CONTRACTOR WHICH WILL ADVERSELY AFFECT THE WORK SHALL BE IMMEDIATELY BE BROUGHT TO THE ATTENTION OF THE ARCHITECT /ENGINEER. CORRECTION OF ANY DEFECTS SHALL BE COMPLETELY WITHOUT ADDITIONAL CHARGE AND SHALL INCLUDE REPLACEMENTS OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED THEREBY. 6.- CUTTING AND PATCHING: MAJOR CUTTING, PATCHING do PAINTING REQUIRED BY THIS CONTRACT WILL BE PERFORMED IN A NEAT AND WORKMANLIKE MANNER. ALL SURFACES SHALL BE RETURNED TO ORIGINAL CONDITIONS AFTER THE INSTALLATION OF THE EQUIPMENT. 7. -THE ELECTRICAL INSTALLATION SHALL MEET ALL STANDARD REQUIREMENTS OF THE LOCAL ELECTRIC UTILITY AND THE TELEPHONE COMPANY. 8.-LOAD DATA IS BASED ON INFORMATION PROVIDED TO THE ENGINEER AT THE TIME OF DESIGN. ALL EQUIPMENT AND PANEL SIZES SHALL BE VERIFIED BEFORE ORDERING. 9.- CIRCUITS SHOWN ON PLANS ARE USED TO DETERMINE LOAD DATA AND PANEL SIZES. THE CONTRACTOR SHALL PROVIDE CIRCUIT ROUTING TO SUIT THE JOB CONDITIONS. 10.-- FURNISH AND INSTALL ALL FIXTURES AS CALLED FOR ON THE PLANS OR AS SELECTED BY OWNER /ARCHITECT. 11. --ALL CONDUCTORS SHALL BE RUN IN CONDUIT, U.O.N. 12.- INSTALL 112" EMPTY CONDUIT TO ALL TELEPHONE /DATA OUTLETS. PROVIDE PULL WIRE. 13.- -- INTERFERENCE: THE CONTRACTOR SHALL COORDINATE HIS WORK WITH OTHER TRADES SO THAT INTERFERENCE WITH EXISTING CONDITIONS, CONDUITS, PIPING, EQUIPMENT, ARCHITECTURAL AND STRUCTURAL MEMBERS BE AVOIDED. 14.- PLANS: DRAWINGS ARE BASICALLY DIAGRAMS INTENDED TO DEPICT APPROXIMATELY EQUIPMENT LOCATIONS AND ARRANGEMENTS, NOT TO SHOW EVERY MINOR DETAIL. PLANS SHALL NOT BE SCALED TO DETERMINE EXACT LOCATION AND DIMENSIONS, 15. -ALL ELECTRICAL EQUIPMENT SHALL BE INSTALLED IN ACCESIBLE AREAS ONLY AND ABOVE BASE FLOOD ELEVATION. 16,-CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL WIRING, BREAKER AND FUSES SIZES IN ACCORDANCE WITH A/C EQUIPMENT NAMEPLATES, IF DIFFERENT FROM THOSE SPECIFIED ON DRAWINGS, AS WELL AS ANY FEEDER CHANGES BEING AFFECTED BY THIS CHANGE. CONTRACTOR SHALL_ MAKE ABOVE MENTIONED CHANGES AT NO EXTRA COST. 17.- ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL CONTRACTOR TO PROVIDE ALL REQUIRED J -BOXES AND CONDUITS FOR INSTALLATION OF CONTROL_ WIRING. LOW VOLTAGE CONTROL WIRING AND THEIR TERMINATION IS THE RESPONSIBILITY OF THE MECHANICAL CONTRACTOR. 18.- ELECTRICAL METER AND PANEL LOCATIONS SHOWN MAY VARY DEPENDING ON SERVICE_ ENTRANCE LOCATION. 19. -ALL LIGHTING FIXTURES TO BE SELECTED BY THE OWNER /ARCHITECT, U.O.N. AND SHALL BE INSTALLED BY THIS CONTRACTOR. 20.- BALANCE ALL PHASES AT EACH PANEL AND MDP /SERVICE MAINS. 21. -CHECK AVAILABLE ELECTRICAL SERVICE CHARACTERISTICS WITH THE LOCAL POWER COMPANY PRIOR TO ORDERING ANY EQUIPMENT. INFORM THE ARCH /ENGINEER IF IT IS DIFFERENT FROM WHAT IS SHOWN ON PLANS. 22.- ELECTRICAL CONTRACTOR SHALL ASSURE THAT ALL FEATURES OF SERVICE COMPLY WITH THE POWER COMPANY'S REQUIREMENTS AND SHALL MAKE ALL NECESSARY ARRANGEMENTS WITH POWER COMPANY FOR SERVICE. ALL EQUIPMENT NOT FURNISHED AND /OR INSTALLED BY THE POWER CO. IS TO BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. 23.- U.O.N., COORDINATE REQUIRED A.I.C. RATINGS WITH POWER COMPANY. 24. -WHERE MORE THAN ONE DEVICE IS INDICATED AT ANY LOCATION, THESE SHALL BE GANGED UNDER ONE COMMON COVER. 25.- QUANTITY AND LOCATION OF ELECTRICAL, TELEPHONE /DATA do TV OUTLETS, LIGHTS AND LIGHT CONTROLS, SHALL BE ADJUSTED TO SUIT THE OWNER'S REQUIREMENTS AS PER OWNER /ARCHITECT INSTRUCTIONS. SAID ARRANGEMENTS SHALL NOT BE IN CONFLICT WITH APPLICABLE CODES. 26.- ELECTRICAL CONTRACTOR SHALL VERIFY REQUIREMENTS, EXACT LOCATIONS, TYPE AND ARRANGEMENT OF OUTLETS FOR ALL ELECTRICAL FIXTURES, APPLIANCES AND EQUIPMENT, PRIOR TO INSTALLATION. 27.- PROVIDE A TYPEWRITTEN DIRECTORY FOR EACH ELECTRICAL PANEL. 28.- CONTRACTOR SHALL FURNISH AS- -BUILT DRAWINGS TO THE OWNER UPON COMPLETION OF WORK AND PRIOR TO FINAL PAYMENT. 29. OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS, CAST ALLOY WITH THREADED HUBS IN WET /DAMP LOCATIONS AND SPECIAL ENCLOSURES AS REQUIRED FOR OTHER CLASSIFIED AREAS AND SHALL CONFORM TO NEMA STANDARDS. PLASTIC BOXES MAY BE USED WHERE PERMITTED UNDER APPLICABLE CODES AND ORDINANCES. 30. -ALL DISCONNECT SWITCHES SHALL BE SIZED BY NEC REQUIREMENTS TO ACCOMODATE THE EQUIPMENT SERVED, INCLUDING REJECTION CLIPS AND FUSES, WHEN APPLICABLE. SWITCHES SHALL BE HP RATED, QULCK -MAKE, QUICK- BREAK, IN NEMA 1 ENCLOSURES FOR INDOOR AND NEMA 3R FOR OUTDOOR. AddifFO_n to-. .r••. ;..., .ouy v . w • 4 . y . • u r • •r1• • •over, • •e! • •6E+• • Sergio Tejeda Res. 5729 S.W. 60 Avenue, Miami, FL. Professional of Record: Norman Blandon Discipline: Architecture Registration No. AI,?_- ,GG1.,6 x <' �'Q W 6262 SW 40 St. iami Florl Suite 2A a 33155 Florida License Phone 30 Fax 30 A 666 -5151 666 -7581 0003242 This drawing and /or specification is /are provided as an instrument of service by N25 Architecture Co. and is /are intended for use on this project only. This drawing remains the property of N25 Architecture Co. and shall be returned upon determination of intent. All drawings, specifications, designs, models, and arrangements appearing herein constitute the original and unpublished work of N25 Architecture Co. Any reproduction, use, or disclosure of the proprietary information contained herein without the prior consent. of N25 Architecture Co. is strictly prohibited. Sheet Title: ELECTRICAL NOTES & LEGEND Issue Date: Project No. June 8, 2012 Drawing No.: El ■ Professional of Record: Norman Blandon Discipline: Architecture Registration No. AI,?_- ,GG1.,6 x <' �'Q W