10-531-018CAP FOR FUTURE - -° TO FIXTURES
CONNECTION SOLAR GATE VALVE
OR HEAT RECOVERY
GATE VALVE
HEAT TRAP F j 3/4 11 0W 4_4
�, ----• UNION
UI ------ .--- -- PRESSURE $c TEMPERATURE
UNION
DRAIN VALVE --
FINISH FLOOR —
(2) EWH, 80 GAL.
2 -6.0 KW
EF .87
'I _- L
RELIEF VALVE (ASME APPRVD.)
�1" AIR GAP
[" P&T
EMERGENCY DRAIN PAN
(ONLY FOR 2ND FL. & ABOVE)
I°l I S
FLUM51NG FIXTURE SCHEDULE
1) FIXTURES TO COMPLY W/FBC 2001 Plumbine Sectfone,
109.1,ro03.i 4 ro04,3
2) ANTI -SCALD VALVE:
ALL SHOWERS 4 BATH /SHOWER COMBINATION$ SHALL
BE PROTECTED WITH A CONTROL VALVE OF THE
PRESSURE BALANCE, THERM05TSTIC MIXINGS OR COM-
BINATION TYPE SET. HANDLE POSITION STOPS PER
MANUFACTURERS INSTRUCTIONS AT TIME OF INSTALLATION
TO A MAXIMUM MIXED WATER OUTLET TEMPERATURE OF 120° F.
FLUM51NG GENERAL NOTES AND 5FECIFIC,4TION3.
L A. SCOPE OF WORK:
THE WORK SHALL INCLUDE ALL PLUMBING NECESSARY SHOWN ON THE
DRAWINGS, SPECIFIED HEREIN AND /OR AS NEEDED FOR A COMPLETE.
SYSTEM, INCLUDING BUT NOT NECESSARILY LIMITED TO.
1. DOMESTIC COLD AND HOT WATER PIPING SYSTEMS
2, SANITARY DRAIN AND VENT SYSTEMS
3, PLUMBING FIXTURES AND TRIM
4, AIR CONDITIONING CONDENSATE DRAINS
5. PRESSURE AND TEMPERATURE RELIEF FROM WATER HEATER
1/a, PIPING INSULATION
i. 5UPPORT5 AND HANGERS
B. ALL PLUMBING WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST
EDITION OF THE " FLORIDA BUILDING CODE" LOCAL ORDINANCES
AND IN COMPLIANCE WITH THE "FLORIDA ENERGY EFFICIENCY CODE FOR
BUILDING CONSTRUCTION ", AND 11HR5" REGULATIONS. IN THE EVENT OF
CONFLICT BETWEEN ANY CODE OR REGULATIONS, THE MORE STRINGENT
REQUIREMENTS WILL GOVERN.
2. CONTRACTOR TO VERIFY AT 51TE THE LOCATION, ELEVATION AND SIZE OF ALL
EXISTING LINES FOR CONNECTION BEFORE INSTALLATION OF ANY PIPING.
3, UNDERGROUND METAL PIPING SHALL BE PROTECTED WITH A COAT OF BITUMINOUS
COMPOUND BEFORE COVERING
4. ALL FIXTURES SHALL BE PROTECTED AGAINST WATER HAMMER WITH AIR CHAMBERS
OR SHOCK ABSORBERS AS INDICATED ON PLANS.
5. ALL FLOOR DRAINS TO HAVE TRAP PRIMERS 1/2" LINE FROM THE NEAREST
PLUMBING FIXTURE,
(0 . PLUMBING FIXTURES SHALL BE CONSTRUCTED WITH THE APPROVED MATERIALS,
SHALL HAVE SMOOTH IMPERVIOUS SURFACES AND SHALL BE FREE FROM DEFECTS
AND CONCEALED FOULING SURFACES. ALL FIXTURE TRIM TO BE CHROME PLATED.
FIXTURES SHALL BE PROVIDED WITH SUPPORTS, HANGERS, ETC.
-1. UNDERGROUND WASTE LINES ABOVE 2 "TO BE PVC 5CH, 40 AND SLOPE a 118111 FT,
WASTE LINES 2" AND UNDER, AND A50VE GROUND PIPES - SLOPE s 1 /4 "/FT,
5. PROVIDE FULLY ACCE65115LE CLEAN OUTS N SANITARY AND ANY WASTE PIPING AT
EVERY CHANGE OF DIRECTION, AND AT BOTTOM OF STACKS. CLEAN OUT LOCATIONS
AND SIZES N HORIZONTAL LINE$ SHALL BE ACCORDING TO CODE,
9, VENT LINES TO EXTEND 911 MIN. ABOVE ROOF AND FLASH WITH LEAD,
10, WATER PIPE BELOW GROUND SHALL BE COPPER TYPE "K" ABOVE GROUND TO BE
COPPER TYPE "L", OR APPROVED CPVC , NO JOINTS ALLOWED UNDER SLAB,
11, PIPING
A, SUPPORT ALL PIPE FROM SOUND PORTIN5 OF STRUCTURE AND AT PROPER
INTERVALS ACCORDING WITH CODE,
B. PROVIDE SLEEVES FOR ALL PIPING PASSING THROUGH FOUNDATION 5LA55 OR
MASONRY WALLS, CAULK OPENINGS BETWEEN PIPE AND SLEEVES.
C, WHERE EXPOSED PIPES PASS THROUGH FLOORS, WALLS, OR CEILINGS, PROVIDE
ESCUTCHEONS FIRMLY SECURED TO THE PIPES AND OF SUFFICIENT OUT5IDE
DIAMETER TO COVER THE ;~SLEEVED OPENINGS FOR THE PIPES. PROVIDE
CHROMIUM PLATED ESCUTCHEON$ IN BATHROOMS,
12. INSPECTIONS AND TESTS
A. CONTRACTOR SHALL BE RESPONSIBLE TO ASK FOR INSPECTIONS TO THE
AUTHORITIES HAVING JURISDICTION, AS THE WORK PROGRESSES. ALL
5Y5TEM5 SHALL BE TESTED BY CODE AND /OR LOCAL REGULATIONS.
B, DRAINAGE PIPING, BEFORE INSTALLATION OF ANY DRAIN$, THE ENDS OF
SYSTEMS SHALL BE CAPPED AND ALL LINES FILLED WITH THE WATER TO THE
HIGHEST POINT AND ALLOWED TO STAND UNTIL. INSPECTION IS MADE BY AN
OWNER REPRESENTATIVE,
13. STERILIZE ALL WATER LINES WITH A MIXTURE OF TWO (2) POUNDS OF CHLORINATED
LIME TO EACH 1.000 GALLONS OF WATER (50 PPM OF AVAILABLE CHLORINE).
RETAIN MIXTURE IN PIPES 24 HOURS AND FLUSH THOROUGHLY WITH POTABLE WATER
BEFORE PLACING IN SERVICE,
14. COMPLETE SYSTEM, FIXTURES AND EQUIPMENT SHALL BE GIVEN AN IN- SERVICE TEST
AFTER COMPLETION OF THE INSTALLATION.
ro"O 2ro CAA,
ROOF CAP.... --.,- -\
c2AGi�
KITCHEN
COOK H XHAU T RISER
N,T.S.
AIR CONDITIONIN CHEDUL
TRAP
FIXTURE
HOT
GOLF
MARK
SIZE
UNITS
WATER
WATER
We
- - - -
- - -
24 x 21 x 52
_
LAV
11/2"
1
1,211
1/211
5H
211
2
1/211
1/211
- - --
11/211
2
1/2 11
1/211
�5K
WI I
211
22
1/211
1/211
DW
111 SW
N/A
Iro00
,40
10
3.5 1/
_ -__
Ire" W /VALVE 4
HB
-
-
-
VAC. 5REAKER
9�,
TUB
211
11/211
2
1/2 11
1/211
U.G.
A.Gs
BD
2"
11/2'
_
2
1/211
_
1/211 -
U.G,
14 C31
_
1) FIXTURES TO COMPLY W/FBC 2001 Plumbine Sectfone,
109.1,ro03.i 4 ro04,3
2) ANTI -SCALD VALVE:
ALL SHOWERS 4 BATH /SHOWER COMBINATION$ SHALL
BE PROTECTED WITH A CONTROL VALVE OF THE
PRESSURE BALANCE, THERM05TSTIC MIXINGS OR COM-
BINATION TYPE SET. HANDLE POSITION STOPS PER
MANUFACTURERS INSTRUCTIONS AT TIME OF INSTALLATION
TO A MAXIMUM MIXED WATER OUTLET TEMPERATURE OF 120° F.
FLUM51NG GENERAL NOTES AND 5FECIFIC,4TION3.
L A. SCOPE OF WORK:
THE WORK SHALL INCLUDE ALL PLUMBING NECESSARY SHOWN ON THE
DRAWINGS, SPECIFIED HEREIN AND /OR AS NEEDED FOR A COMPLETE.
SYSTEM, INCLUDING BUT NOT NECESSARILY LIMITED TO.
1. DOMESTIC COLD AND HOT WATER PIPING SYSTEMS
2, SANITARY DRAIN AND VENT SYSTEMS
3, PLUMBING FIXTURES AND TRIM
4, AIR CONDITIONING CONDENSATE DRAINS
5. PRESSURE AND TEMPERATURE RELIEF FROM WATER HEATER
1/a, PIPING INSULATION
i. 5UPPORT5 AND HANGERS
B. ALL PLUMBING WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST
EDITION OF THE " FLORIDA BUILDING CODE" LOCAL ORDINANCES
AND IN COMPLIANCE WITH THE "FLORIDA ENERGY EFFICIENCY CODE FOR
BUILDING CONSTRUCTION ", AND 11HR5" REGULATIONS. IN THE EVENT OF
CONFLICT BETWEEN ANY CODE OR REGULATIONS, THE MORE STRINGENT
REQUIREMENTS WILL GOVERN.
2. CONTRACTOR TO VERIFY AT 51TE THE LOCATION, ELEVATION AND SIZE OF ALL
EXISTING LINES FOR CONNECTION BEFORE INSTALLATION OF ANY PIPING.
3, UNDERGROUND METAL PIPING SHALL BE PROTECTED WITH A COAT OF BITUMINOUS
COMPOUND BEFORE COVERING
4. ALL FIXTURES SHALL BE PROTECTED AGAINST WATER HAMMER WITH AIR CHAMBERS
OR SHOCK ABSORBERS AS INDICATED ON PLANS.
5. ALL FLOOR DRAINS TO HAVE TRAP PRIMERS 1/2" LINE FROM THE NEAREST
PLUMBING FIXTURE,
(0 . PLUMBING FIXTURES SHALL BE CONSTRUCTED WITH THE APPROVED MATERIALS,
SHALL HAVE SMOOTH IMPERVIOUS SURFACES AND SHALL BE FREE FROM DEFECTS
AND CONCEALED FOULING SURFACES. ALL FIXTURE TRIM TO BE CHROME PLATED.
FIXTURES SHALL BE PROVIDED WITH SUPPORTS, HANGERS, ETC.
-1. UNDERGROUND WASTE LINES ABOVE 2 "TO BE PVC 5CH, 40 AND SLOPE a 118111 FT,
WASTE LINES 2" AND UNDER, AND A50VE GROUND PIPES - SLOPE s 1 /4 "/FT,
5. PROVIDE FULLY ACCE65115LE CLEAN OUTS N SANITARY AND ANY WASTE PIPING AT
EVERY CHANGE OF DIRECTION, AND AT BOTTOM OF STACKS. CLEAN OUT LOCATIONS
AND SIZES N HORIZONTAL LINE$ SHALL BE ACCORDING TO CODE,
9, VENT LINES TO EXTEND 911 MIN. ABOVE ROOF AND FLASH WITH LEAD,
10, WATER PIPE BELOW GROUND SHALL BE COPPER TYPE "K" ABOVE GROUND TO BE
COPPER TYPE "L", OR APPROVED CPVC , NO JOINTS ALLOWED UNDER SLAB,
11, PIPING
A, SUPPORT ALL PIPE FROM SOUND PORTIN5 OF STRUCTURE AND AT PROPER
INTERVALS ACCORDING WITH CODE,
B. PROVIDE SLEEVES FOR ALL PIPING PASSING THROUGH FOUNDATION 5LA55 OR
MASONRY WALLS, CAULK OPENINGS BETWEEN PIPE AND SLEEVES.
C, WHERE EXPOSED PIPES PASS THROUGH FLOORS, WALLS, OR CEILINGS, PROVIDE
ESCUTCHEONS FIRMLY SECURED TO THE PIPES AND OF SUFFICIENT OUT5IDE
DIAMETER TO COVER THE ;~SLEEVED OPENINGS FOR THE PIPES. PROVIDE
CHROMIUM PLATED ESCUTCHEON$ IN BATHROOMS,
12. INSPECTIONS AND TESTS
A. CONTRACTOR SHALL BE RESPONSIBLE TO ASK FOR INSPECTIONS TO THE
AUTHORITIES HAVING JURISDICTION, AS THE WORK PROGRESSES. ALL
5Y5TEM5 SHALL BE TESTED BY CODE AND /OR LOCAL REGULATIONS.
B, DRAINAGE PIPING, BEFORE INSTALLATION OF ANY DRAIN$, THE ENDS OF
SYSTEMS SHALL BE CAPPED AND ALL LINES FILLED WITH THE WATER TO THE
HIGHEST POINT AND ALLOWED TO STAND UNTIL. INSPECTION IS MADE BY AN
OWNER REPRESENTATIVE,
13. STERILIZE ALL WATER LINES WITH A MIXTURE OF TWO (2) POUNDS OF CHLORINATED
LIME TO EACH 1.000 GALLONS OF WATER (50 PPM OF AVAILABLE CHLORINE).
RETAIN MIXTURE IN PIPES 24 HOURS AND FLUSH THOROUGHLY WITH POTABLE WATER
BEFORE PLACING IN SERVICE,
14. COMPLETE SYSTEM, FIXTURES AND EQUIPMENT SHALL BE GIVEN AN IN- SERVICE TEST
AFTER COMPLETION OF THE INSTALLATION.
ro"O 2ro CAA,
ROOF CAP.... --.,- -\
c2AGi�
KITCHEN
COOK H XHAU T RISER
N,T.S.
AIR CONDITIONIN CHEDUL
MANUFACTURER NOM. NOM. ESP IN, ELECT, TOTAL TOTAL COOLING CAP, 6/T O/A DIMENSIONS WEIGHT ELECT. SERVICE SUCTION LIQUID
UNIT R
AND MODEL NO, TONS CFM uJG, HEAT KW FLA /HP MCA/MO- BTUH 0 95° 4 9, 1` W CFM WxLxH (IN.) LBS. VOLTS /P H /Hz LINE LINE
AHU
TRANE - TWra030A14OB
---
1000
.40
5
2.0 1/4
- _ - _
- - - -
- - -
24 x 21 x 52
110
205 -230/1 /(oO
12,00
---
- - -
C1U
TRANE- 2TTB2030AI000A
2,5
- --
- - --
- - --
- - --
i 30
20,600/2,3,000
- --
21�X2(OX21B
160
208 - 230 /1 /(oO
EF"2
1 -1 /S
3/0
AHU
TRANE- TU,1Cx048A1405
--T
Iro00
,40
10
3.5 1/
_ -__
__
22 x 21 x 43
131
208 -230/1 / sa
12.00
- --
DAMPER 4 ROOF CAF'
_
CU
02 #3
TRANE- 2TTB2045AIOOOA
4
---
- - _ _
- - _ -
_ _
2ro
45
34,400/4i,500
---
33X30X37
21
205- 23011100
3/4
5/10
HVAC DESIGN REQUIRES:
Y E 5
NO
DUCT SMOKE DETECTOR
MANUFACTURER
x
FIRE DAMPER (5)
WEIGHT
x
SMOKE DAMPER($)
0,LxH (IN.)
x
FIRE RATED ENCLOSURE
NUTONE /1-5-50
x
pII E RATED ROC 5/FLOOPw
CEILING AS6EMf31_Y
�50 * 1/5"
x
FIRE STOPPING
- --
x
SMOKE CONTROIL
x
Q)
PIPE IN.SUL,,
/mmCO11DEN61NG
'0� UNIT
"4CRETE PAD
THICK MIN
HVAC LEC_iI= D TO AIR HANDLIER 30� "Xl. "L . Tr4P -CON6, OR LAG BOLTS W1 SHIELDS INSIDE
ALL AHUe TO WITH eAME MODEL THRU CEILING SPACE C. UNIT THRU 5,43E P1_,4TE TO WITH&T,4NF-) WIND& COVER, 14ro MPH WITH
SUPPLY AIR DIFFUSER 4N ,4NCHOR 5OLT OF 500 POUNDS MINIMUM PULL OUT CAF,4CIT1T'.
RETURN AIR GRILLE ON N I UNIT
OT THERMOSTAT A 14
INi ION _TAIL
SUPPLY AIR DUCT RECTANGULAR CROSS SECTION NO 6CALE
-�' RETURN AIR DUCT RECTANGULAR CRO55 SECTION
_I'/211 MIN.
TURNING VANE � STRAP, 26 C,z.
SUPPLY DUCT-7 ,. -�
VOLUME DAMPER, IN LINE 1UO03 SCREW —
MECHANICALLY ATTACH_
`ip VOLUME DAMPER, AT TAKE OFF R /,LS, -► j-)UJGT ` " WOOD JOIST
WHEN APPLY � � / � CONNECT I NLEXI�LE �
(�, REFRIGERANT LINES �
��i
FLEXIBLE ROUND DUCT TO OUTSIDE CONDENSING
UNIT THRU ATTIC SPACE
1 �
5PL ITTER PAMPER ROUND
OPEN DUCT HANGER STRAW FLEX FLEX DUCT.
11/ /211 22G
IN CLOSET n \—CEILING 0
FAN 3/4" CONDENSATE
DRAIN w/ 3" TRAP I – PARTITION DUCT PRESSURE
A -- —A FIRE DAMPER UNION AND C,O TO ,
GREEN AREA I I PERFORATED CAP FOR
-VENT, 12 HIGH
OS
SMOKE DETECTOR I I _0
1t k s� OPPOSED BLADE DAMPER GALV. STEEL I I —SECONDARY FOR DUCTS OVER
A.H.U. SUPPORT DR AIN WIDE, FASTEN UNDER
J_j (SELF- $TANDING) --o,,, I I 15OTTOM OF DUCT
�J ELECTRIC STRIP HEATER NO COMBUSTIBLE-----, I I PROV13 411 CLEARANCE
M A.H.U. RIAL5"( WITHIN � � � I � ALL AROUND AHU
MOTORIZED DAMPER
R/A THRU I i '' DRAIN PAN DUCT HAND INC; DETAIL.
LOU R POOR ` I NTS
1 . FLOOR.
4IR CONDITIONING; 5Y6TEM - C3EN RAL- NOTES:
DUCTWORK SHALL BE 1 1/2" THICK, 3 POUNDS PER CUBIC FOOT DENSITY
FI5ERGLA55 WITH VAPOR BARRIER, UNLESS OTHERWISE SPECIFIED,
DUCTWORK SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE
WITH MANUFACTURER'S 5PECIFICATION5 AND ACCORDING TO '1A6HRAE"
AND "5MACNA" STANDARDS.
DUCT DIMENSIONS ARE IN INCHES AND CORRESPOND TO INSIDE
DIMENSIONS WIDTH X HEIGHT, DUCT SYSTEM SHALL COMPLY WITH
"NFPA" STANDARD NO, 90A AND /OR 905. DUCTWORK AND COMPONENTS
SHALL BE CLASS I MATERIALS IN ACCORDANCE WITH U.L. 151
2. COORDINATE LOCATIONS, SIZES AND OPENINGS WITH OTHER TRADES
ON THE JOB. A/C CONTRACTOR SHALL PROVIDE THE COMPLETE DUCT
SYSTEM A/C CONTRACTOR SHALL USE THE BEST PRACTICES OF THE TRADE IN
THE FABRICATION AND INSTALLATION OF THE SYSTEM.
3, DIFFUSERS SHALL BE SELECTED, LOCATED, AND BALANCED IN ORDER
THAT THEY DELIVER THE REQUIRED CFM TO THE ENTIRE ROOM EVENLY
AND DRAFT FREE TO MAINTAIN THE FOLLOWING DESIGN CONDITIONS-.
INSIDE OUTSIDE RELATIVE HUMIDITY
COOLING - 16 DB IN DB - "IS WB 50% TO roO%
HEATING - 10 DB 41° - DB
4, ALL FAN UNITS, MOTORS, COMPRESSORS, ETC. SHALL BE ISOLATED,
AS REQUIRED TO OPERATE QUIETLY 50 THAT NOOBJECTIONABLE SOUND
WILL BE HEARD IN THE HABITABLE SPACES DUE TO AIR VELOCITY,
MOTOR HUM, VIBRATION, OR MECHANICAL MOVEMENT.
5. A/C SYSTEM SHALL HAVE CLEANABLE AIR FILTERS LOCATED AS
REQUIRED FOR EASY ACCESSIBILITY.
(o. A/C SYSTEM SHALL BE CONTROLLED BY A THERMOSTAT. MOUNT
THERMOSTAT 5' -011 ABOVE FINISHED FLOOR, U.O.N.
1 ALL GRILLS AND DIFFUSERS TO BE ALUMINUM OR STEEL CONSTRUCTION. DIF-
FU5ER5 TO HAVE OP05EP BLADE DAMPERS. PROVIDE GASKETS
ON ALL GRILLES AND DIFFUSERS. TITUS OR AIREnUIDE OR APPROVED EQUAL
WHiTH ENAMEL FINISH
S. UNDERCUT DOORS 111 A.F.F., FOR R/A FOR ROOMS WITH LE55 THAN 110 CFM
FOR ROOMS WITH OVER 110 CFM PROVIDE RAG. AND TRANSFER DUCT,
9, ALL REFRIGERANT PIPING SHALL. BE COPPER - TYPE L -
ACR TYPE, DEHYDRATED AND SEALED. ALL FITTINGS SHALL BE
WROUGHT COPPER. ALL JOINTS SHALL BE MADE WITH HIGH
TEMPERATURE BRAZING ALLOY OF NOT LE55 THAN 5% SILVER.
PIPING INSTALLATION NOT LESS THAN 3/4" THICK "ARMAFLEX ",
LIQUID AND SUCTION LINES SHALL BE SIZED ACCORDING TO
EQUIPMENT MANUFACTURER'S RECOMMENDATIONS FOR EQUIVALENT
LENGTH OF PIPING RUN FOR CONNECTED TONNAGE, ALL PIPING
ACCES50RIE3 SHALL BE CONSTRUCTED A$ SUGGESTED BY EQUIPMENT
MANUFACTURER. ALL PIPING SHALL BE (EVACUATED PER GOOD
PIPING PRACTICE BEFORE START -UP.
SEAL JOINT U
EPDXY 4 DU(
2 "A /C C.D.
UNDERSLAB
4IR HANDLER UNIT
IN5TALLATI N DETAIL
NO SCAIL
AIR FLOW
2nd. FLC
CEILING SP
CLG,
DUCT 51ZE .
FAN SCHEDULE
MAX. SPACING
UP THRU 2 S,F.
MANUFACTURER
UJATT ELECT, SERVICE
D1MEN51ON5
WEIGHT
FAN " AND MODEL NO.
I"` HP CFM SP. VOLTS/PH/Hz /Hz
0,LxH (IN.)
L5$, REMAi S 9CiN v
EPI
NUTONE /1-5-50
- --
`4"
�50 * 1/5"
12x1Ox8
- --
1U /GRILLE, 4 "d DUCT S/M
f1y3
Q)
DAMPER 4 ROOF CAF'
EF"2
NUTONE / QT -130
- --
13O w I /g"
I2A /I /4aO �
lrrvxl2xlo
_ --
W /GRILLE, 6"4 DUCT 5/M �
20
DAMPER 4 ROOF CAF'
PIPE IN.SUL,,
/mmCO11DEN61NG
'0� UNIT
"4CRETE PAD
THICK MIN
HVAC LEC_iI= D TO AIR HANDLIER 30� "Xl. "L . Tr4P -CON6, OR LAG BOLTS W1 SHIELDS INSIDE
ALL AHUe TO WITH eAME MODEL THRU CEILING SPACE C. UNIT THRU 5,43E P1_,4TE TO WITH&T,4NF-) WIND& COVER, 14ro MPH WITH
SUPPLY AIR DIFFUSER 4N ,4NCHOR 5OLT OF 500 POUNDS MINIMUM PULL OUT CAF,4CIT1T'.
RETURN AIR GRILLE ON N I UNIT
OT THERMOSTAT A 14
INi ION _TAIL
SUPPLY AIR DUCT RECTANGULAR CROSS SECTION NO 6CALE
-�' RETURN AIR DUCT RECTANGULAR CRO55 SECTION
_I'/211 MIN.
TURNING VANE � STRAP, 26 C,z.
SUPPLY DUCT-7 ,. -�
VOLUME DAMPER, IN LINE 1UO03 SCREW —
MECHANICALLY ATTACH_
`ip VOLUME DAMPER, AT TAKE OFF R /,LS, -► j-)UJGT ` " WOOD JOIST
WHEN APPLY � � / � CONNECT I NLEXI�LE �
(�, REFRIGERANT LINES �
��i
FLEXIBLE ROUND DUCT TO OUTSIDE CONDENSING
UNIT THRU ATTIC SPACE
1 �
5PL ITTER PAMPER ROUND
OPEN DUCT HANGER STRAW FLEX FLEX DUCT.
11/ /211 22G
IN CLOSET n \—CEILING 0
FAN 3/4" CONDENSATE
DRAIN w/ 3" TRAP I – PARTITION DUCT PRESSURE
A -- —A FIRE DAMPER UNION AND C,O TO ,
GREEN AREA I I PERFORATED CAP FOR
-VENT, 12 HIGH
OS
SMOKE DETECTOR I I _0
1t k s� OPPOSED BLADE DAMPER GALV. STEEL I I —SECONDARY FOR DUCTS OVER
A.H.U. SUPPORT DR AIN WIDE, FASTEN UNDER
J_j (SELF- $TANDING) --o,,, I I 15OTTOM OF DUCT
�J ELECTRIC STRIP HEATER NO COMBUSTIBLE-----, I I PROV13 411 CLEARANCE
M A.H.U. RIAL5"( WITHIN � � � I � ALL AROUND AHU
MOTORIZED DAMPER
R/A THRU I i '' DRAIN PAN DUCT HAND INC; DETAIL.
LOU R POOR ` I NTS
1 . FLOOR.
4IR CONDITIONING; 5Y6TEM - C3EN RAL- NOTES:
DUCTWORK SHALL BE 1 1/2" THICK, 3 POUNDS PER CUBIC FOOT DENSITY
FI5ERGLA55 WITH VAPOR BARRIER, UNLESS OTHERWISE SPECIFIED,
DUCTWORK SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE
WITH MANUFACTURER'S 5PECIFICATION5 AND ACCORDING TO '1A6HRAE"
AND "5MACNA" STANDARDS.
DUCT DIMENSIONS ARE IN INCHES AND CORRESPOND TO INSIDE
DIMENSIONS WIDTH X HEIGHT, DUCT SYSTEM SHALL COMPLY WITH
"NFPA" STANDARD NO, 90A AND /OR 905. DUCTWORK AND COMPONENTS
SHALL BE CLASS I MATERIALS IN ACCORDANCE WITH U.L. 151
2. COORDINATE LOCATIONS, SIZES AND OPENINGS WITH OTHER TRADES
ON THE JOB. A/C CONTRACTOR SHALL PROVIDE THE COMPLETE DUCT
SYSTEM A/C CONTRACTOR SHALL USE THE BEST PRACTICES OF THE TRADE IN
THE FABRICATION AND INSTALLATION OF THE SYSTEM.
3, DIFFUSERS SHALL BE SELECTED, LOCATED, AND BALANCED IN ORDER
THAT THEY DELIVER THE REQUIRED CFM TO THE ENTIRE ROOM EVENLY
AND DRAFT FREE TO MAINTAIN THE FOLLOWING DESIGN CONDITIONS-.
INSIDE OUTSIDE RELATIVE HUMIDITY
COOLING - 16 DB IN DB - "IS WB 50% TO roO%
HEATING - 10 DB 41° - DB
4, ALL FAN UNITS, MOTORS, COMPRESSORS, ETC. SHALL BE ISOLATED,
AS REQUIRED TO OPERATE QUIETLY 50 THAT NOOBJECTIONABLE SOUND
WILL BE HEARD IN THE HABITABLE SPACES DUE TO AIR VELOCITY,
MOTOR HUM, VIBRATION, OR MECHANICAL MOVEMENT.
5. A/C SYSTEM SHALL HAVE CLEANABLE AIR FILTERS LOCATED AS
REQUIRED FOR EASY ACCESSIBILITY.
(o. A/C SYSTEM SHALL BE CONTROLLED BY A THERMOSTAT. MOUNT
THERMOSTAT 5' -011 ABOVE FINISHED FLOOR, U.O.N.
1 ALL GRILLS AND DIFFUSERS TO BE ALUMINUM OR STEEL CONSTRUCTION. DIF-
FU5ER5 TO HAVE OP05EP BLADE DAMPERS. PROVIDE GASKETS
ON ALL GRILLES AND DIFFUSERS. TITUS OR AIREnUIDE OR APPROVED EQUAL
WHiTH ENAMEL FINISH
S. UNDERCUT DOORS 111 A.F.F., FOR R/A FOR ROOMS WITH LE55 THAN 110 CFM
FOR ROOMS WITH OVER 110 CFM PROVIDE RAG. AND TRANSFER DUCT,
9, ALL REFRIGERANT PIPING SHALL. BE COPPER - TYPE L -
ACR TYPE, DEHYDRATED AND SEALED. ALL FITTINGS SHALL BE
WROUGHT COPPER. ALL JOINTS SHALL BE MADE WITH HIGH
TEMPERATURE BRAZING ALLOY OF NOT LE55 THAN 5% SILVER.
PIPING INSTALLATION NOT LESS THAN 3/4" THICK "ARMAFLEX ",
LIQUID AND SUCTION LINES SHALL BE SIZED ACCORDING TO
EQUIPMENT MANUFACTURER'S RECOMMENDATIONS FOR EQUIVALENT
LENGTH OF PIPING RUN FOR CONNECTED TONNAGE, ALL PIPING
ACCES50RIE3 SHALL BE CONSTRUCTED A$ SUGGESTED BY EQUIPMENT
MANUFACTURER. ALL PIPING SHALL BE (EVACUATED PER GOOD
PIPING PRACTICE BEFORE START -UP.
SEAL JOINT U
EPDXY 4 DU(
2 "A /C C.D.
UNDERSLAB
4IR HANDLER UNIT
IN5TALLATI N DETAIL
NO SCAIL
AIR FLOW
2nd. FLC
CEILING SP
CLG,
DUCT 51ZE .
HANGER SIZE
MAX. SPACING
UP THRU 2 S,F.
111/2" x 2(o G
1_011
2 THRU 4 5.F,
11 /211 x 1 /16"
4 THRU 10 S.F.
1'112 °` x 1/1&"
OVER 10 S.F.
11 /a" x
NOOK
MANUFACTURER. ALL PIPINGS SHALL ESE EVACUATED
PER GOOD PIPING PRACTICE E5EFORE 5TART -UP.
LOW VELOCITY - -- --�* '' I -ems --
: _._ L...._I WALL CAP
SUPPLY AIR DUCT - EXHAUST DUCT
(NEE PLAN VIEW)
INSUL R -6
METAL. ROUND FITTING:
QUADRANT OPERATOR
TO ESE OUTSIDE INSULATION
PROVIDE INSULATION GUARD
WHERE NECESSARY
INSULATED FLEX. DUCT.'
11/2" F /Gz,WiTH POLYETHELENE
JACK,ETAND STEEL.
WIRE REINFORCING(R -o)
AIR FLOW
ADJUSTABLE VOLUME
DAMPER
SEAL JOINT WITH
EPDXY 4 DUCT TAPE
PERFORATED DIFFUSER
TYFIC 4L D IFFU &ER CONNECTION DETAIL
NO SCALE
CLG.
E XHAU &T FAN 4 UCT - E TA I L.
N.T.S.
ROOF CAP.
BASE
M
- --.-.- -.–AIR FLOW
S/M 26 G. SIZE
DEPEND OF 'TYPE OF FAN
SEE FAN SCHEDULE,
EXHAUST DUCT ._/
EXHAUST FAN 4 DUCT-DETAIL
N.T.S. -�
JOB #: XXXXX
GUERRERO /GONZALEZ
ENGINEERS, INC.
"lill 17 Michael C. Guerrero, P.E.
wmwa Mechanical Eng. Lic. #15235
Rafael L. Gonzalez, P.E.
Electrical Eng. Lic. #11057
4300 S.W. 73rd Avenue, Suite #107A
Miami, Florida 33155
T0. (305) 262 -3944, Fax (305) 262 -8211
E —mail: PROJECTSOGUERREROGONZALEZENGINEERS .COM
r— --- - - —. -.
DAVID. STOTT " AI.JTMAN
A .2 C H I T E C T
5880 SC, 7w 8T #f MIAMI, FLORIDA. 33143
305- 687 -0019 TEL 305 -669 -3102 FAX
REVISIONS
Q)
Q)
4
<1
SEAL
~vim - ", z, a •a � ; �
js I t
2� s
r y'1J,
r M1, r
4�
curr /WATERH 8-- 24--04