Loading...
10-531-018CAP FOR FUTURE - -° TO FIXTURES CONNECTION SOLAR GATE VALVE OR HEAT RECOVERY GATE VALVE HEAT TRAP F j 3/4 11 0W 4_4 �, ----• UNION UI ------ .--- -- PRESSURE $c TEMPERATURE UNION DRAIN VALVE -- FINISH FLOOR — (2) EWH, 80 GAL. 2 -6.0 KW EF .87 'I _- L RELIEF VALVE (ASME APPRVD.) �1" AIR GAP [" P&T EMERGENCY DRAIN PAN (ONLY FOR 2ND FL. & ABOVE) I°l I S FLUM51NG FIXTURE SCHEDULE 1) FIXTURES TO COMPLY W/FBC 2001 Plumbine Sectfone, 109.1,ro03.i 4 ro04,3 2) ANTI -SCALD VALVE: ALL SHOWERS 4 BATH /SHOWER COMBINATION$ SHALL BE PROTECTED WITH A CONTROL VALVE OF THE PRESSURE BALANCE, THERM05TSTIC MIXINGS OR COM- BINATION TYPE SET. HANDLE POSITION STOPS PER MANUFACTURERS INSTRUCTIONS AT TIME OF INSTALLATION TO A MAXIMUM MIXED WATER OUTLET TEMPERATURE OF 120° F. FLUM51NG GENERAL NOTES AND 5FECIFIC,4TION3. L A. SCOPE OF WORK: THE WORK SHALL INCLUDE ALL PLUMBING NECESSARY SHOWN ON THE DRAWINGS, SPECIFIED HEREIN AND /OR AS NEEDED FOR A COMPLETE. SYSTEM, INCLUDING BUT NOT NECESSARILY LIMITED TO. 1. DOMESTIC COLD AND HOT WATER PIPING SYSTEMS 2, SANITARY DRAIN AND VENT SYSTEMS 3, PLUMBING FIXTURES AND TRIM 4, AIR CONDITIONING CONDENSATE DRAINS 5. PRESSURE AND TEMPERATURE RELIEF FROM WATER HEATER 1/a, PIPING INSULATION i. 5UPPORT5 AND HANGERS B. ALL PLUMBING WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST EDITION OF THE " FLORIDA BUILDING CODE" LOCAL ORDINANCES AND IN COMPLIANCE WITH THE "FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION ", AND 11HR5" REGULATIONS. IN THE EVENT OF CONFLICT BETWEEN ANY CODE OR REGULATIONS, THE MORE STRINGENT REQUIREMENTS WILL GOVERN. 2. CONTRACTOR TO VERIFY AT 51TE THE LOCATION, ELEVATION AND SIZE OF ALL EXISTING LINES FOR CONNECTION BEFORE INSTALLATION OF ANY PIPING. 3, UNDERGROUND METAL PIPING SHALL BE PROTECTED WITH A COAT OF BITUMINOUS COMPOUND BEFORE COVERING 4. ALL FIXTURES SHALL BE PROTECTED AGAINST WATER HAMMER WITH AIR CHAMBERS OR SHOCK ABSORBERS AS INDICATED ON PLANS. 5. ALL FLOOR DRAINS TO HAVE TRAP PRIMERS 1/2" LINE FROM THE NEAREST PLUMBING FIXTURE, (0 . PLUMBING FIXTURES SHALL BE CONSTRUCTED WITH THE APPROVED MATERIALS, SHALL HAVE SMOOTH IMPERVIOUS SURFACES AND SHALL BE FREE FROM DEFECTS AND CONCEALED FOULING SURFACES. ALL FIXTURE TRIM TO BE CHROME PLATED. FIXTURES SHALL BE PROVIDED WITH SUPPORTS, HANGERS, ETC. -1. UNDERGROUND WASTE LINES ABOVE 2 "TO BE PVC 5CH, 40 AND SLOPE a 118111 FT, WASTE LINES 2" AND UNDER, AND A50VE GROUND PIPES - SLOPE s 1 /4 "/FT, 5. PROVIDE FULLY ACCE65115LE CLEAN OUTS N SANITARY AND ANY WASTE PIPING AT EVERY CHANGE OF DIRECTION, AND AT BOTTOM OF STACKS. CLEAN OUT LOCATIONS AND SIZES N HORIZONTAL LINE$ SHALL BE ACCORDING TO CODE, 9, VENT LINES TO EXTEND 911 MIN. ABOVE ROOF AND FLASH WITH LEAD, 10, WATER PIPE BELOW GROUND SHALL BE COPPER TYPE "K" ABOVE GROUND TO BE COPPER TYPE "L", OR APPROVED CPVC , NO JOINTS ALLOWED UNDER SLAB, 11, PIPING A, SUPPORT ALL PIPE FROM SOUND PORTIN5 OF STRUCTURE AND AT PROPER INTERVALS ACCORDING WITH CODE, B. PROVIDE SLEEVES FOR ALL PIPING PASSING THROUGH FOUNDATION 5LA55 OR MASONRY WALLS, CAULK OPENINGS BETWEEN PIPE AND SLEEVES. C, WHERE EXPOSED PIPES PASS THROUGH FLOORS, WALLS, OR CEILINGS, PROVIDE ESCUTCHEONS FIRMLY SECURED TO THE PIPES AND OF SUFFICIENT OUT5IDE DIAMETER TO COVER THE ;~SLEEVED OPENINGS FOR THE PIPES. PROVIDE CHROMIUM PLATED ESCUTCHEON$ IN BATHROOMS, 12. INSPECTIONS AND TESTS A. CONTRACTOR SHALL BE RESPONSIBLE TO ASK FOR INSPECTIONS TO THE AUTHORITIES HAVING JURISDICTION, AS THE WORK PROGRESSES. ALL 5Y5TEM5 SHALL BE TESTED BY CODE AND /OR LOCAL REGULATIONS. B, DRAINAGE PIPING, BEFORE INSTALLATION OF ANY DRAIN$, THE ENDS OF SYSTEMS SHALL BE CAPPED AND ALL LINES FILLED WITH THE WATER TO THE HIGHEST POINT AND ALLOWED TO STAND UNTIL. INSPECTION IS MADE BY AN OWNER REPRESENTATIVE, 13. STERILIZE ALL WATER LINES WITH A MIXTURE OF TWO (2) POUNDS OF CHLORINATED LIME TO EACH 1.000 GALLONS OF WATER (50 PPM OF AVAILABLE CHLORINE). RETAIN MIXTURE IN PIPES 24 HOURS AND FLUSH THOROUGHLY WITH POTABLE WATER BEFORE PLACING IN SERVICE, 14. COMPLETE SYSTEM, FIXTURES AND EQUIPMENT SHALL BE GIVEN AN IN- SERVICE TEST AFTER COMPLETION OF THE INSTALLATION. ro"O 2ro CAA, ROOF CAP.... --.,- -\ c2AGi� KITCHEN COOK H XHAU T RISER N,T.S. AIR CONDITIONIN CHEDUL TRAP FIXTURE HOT GOLF MARK SIZE UNITS WATER WATER We - - - - - - - 24 x 21 x 52 _ LAV 11/2" 1 1,211 1/211 5H 211 2 1/211 1/211 - - -- 11/211 2 1/2 11 1/211 �5K WI I 211 22 1/211 1/211 DW 111 SW N/A Iro00 ,40 10 3.5 1/ _ -__ Ire" W /VALVE 4 HB - - - VAC. 5REAKER 9�, TUB 211 11/211 2 1/2 11 1/211 U.G. A.Gs BD 2" 11/2' _ 2 1/211 _ 1/211 - U.G, 14 C31 _ 1) FIXTURES TO COMPLY W/FBC 2001 Plumbine Sectfone, 109.1,ro03.i 4 ro04,3 2) ANTI -SCALD VALVE: ALL SHOWERS 4 BATH /SHOWER COMBINATION$ SHALL BE PROTECTED WITH A CONTROL VALVE OF THE PRESSURE BALANCE, THERM05TSTIC MIXINGS OR COM- BINATION TYPE SET. HANDLE POSITION STOPS PER MANUFACTURERS INSTRUCTIONS AT TIME OF INSTALLATION TO A MAXIMUM MIXED WATER OUTLET TEMPERATURE OF 120° F. FLUM51NG GENERAL NOTES AND 5FECIFIC,4TION3. L A. SCOPE OF WORK: THE WORK SHALL INCLUDE ALL PLUMBING NECESSARY SHOWN ON THE DRAWINGS, SPECIFIED HEREIN AND /OR AS NEEDED FOR A COMPLETE. SYSTEM, INCLUDING BUT NOT NECESSARILY LIMITED TO. 1. DOMESTIC COLD AND HOT WATER PIPING SYSTEMS 2, SANITARY DRAIN AND VENT SYSTEMS 3, PLUMBING FIXTURES AND TRIM 4, AIR CONDITIONING CONDENSATE DRAINS 5. PRESSURE AND TEMPERATURE RELIEF FROM WATER HEATER 1/a, PIPING INSULATION i. 5UPPORT5 AND HANGERS B. ALL PLUMBING WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST EDITION OF THE " FLORIDA BUILDING CODE" LOCAL ORDINANCES AND IN COMPLIANCE WITH THE "FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION ", AND 11HR5" REGULATIONS. IN THE EVENT OF CONFLICT BETWEEN ANY CODE OR REGULATIONS, THE MORE STRINGENT REQUIREMENTS WILL GOVERN. 2. CONTRACTOR TO VERIFY AT 51TE THE LOCATION, ELEVATION AND SIZE OF ALL EXISTING LINES FOR CONNECTION BEFORE INSTALLATION OF ANY PIPING. 3, UNDERGROUND METAL PIPING SHALL BE PROTECTED WITH A COAT OF BITUMINOUS COMPOUND BEFORE COVERING 4. ALL FIXTURES SHALL BE PROTECTED AGAINST WATER HAMMER WITH AIR CHAMBERS OR SHOCK ABSORBERS AS INDICATED ON PLANS. 5. ALL FLOOR DRAINS TO HAVE TRAP PRIMERS 1/2" LINE FROM THE NEAREST PLUMBING FIXTURE, (0 . PLUMBING FIXTURES SHALL BE CONSTRUCTED WITH THE APPROVED MATERIALS, SHALL HAVE SMOOTH IMPERVIOUS SURFACES AND SHALL BE FREE FROM DEFECTS AND CONCEALED FOULING SURFACES. ALL FIXTURE TRIM TO BE CHROME PLATED. FIXTURES SHALL BE PROVIDED WITH SUPPORTS, HANGERS, ETC. -1. UNDERGROUND WASTE LINES ABOVE 2 "TO BE PVC 5CH, 40 AND SLOPE a 118111 FT, WASTE LINES 2" AND UNDER, AND A50VE GROUND PIPES - SLOPE s 1 /4 "/FT, 5. PROVIDE FULLY ACCE65115LE CLEAN OUTS N SANITARY AND ANY WASTE PIPING AT EVERY CHANGE OF DIRECTION, AND AT BOTTOM OF STACKS. CLEAN OUT LOCATIONS AND SIZES N HORIZONTAL LINE$ SHALL BE ACCORDING TO CODE, 9, VENT LINES TO EXTEND 911 MIN. ABOVE ROOF AND FLASH WITH LEAD, 10, WATER PIPE BELOW GROUND SHALL BE COPPER TYPE "K" ABOVE GROUND TO BE COPPER TYPE "L", OR APPROVED CPVC , NO JOINTS ALLOWED UNDER SLAB, 11, PIPING A, SUPPORT ALL PIPE FROM SOUND PORTIN5 OF STRUCTURE AND AT PROPER INTERVALS ACCORDING WITH CODE, B. PROVIDE SLEEVES FOR ALL PIPING PASSING THROUGH FOUNDATION 5LA55 OR MASONRY WALLS, CAULK OPENINGS BETWEEN PIPE AND SLEEVES. C, WHERE EXPOSED PIPES PASS THROUGH FLOORS, WALLS, OR CEILINGS, PROVIDE ESCUTCHEONS FIRMLY SECURED TO THE PIPES AND OF SUFFICIENT OUT5IDE DIAMETER TO COVER THE ;~SLEEVED OPENINGS FOR THE PIPES. PROVIDE CHROMIUM PLATED ESCUTCHEON$ IN BATHROOMS, 12. INSPECTIONS AND TESTS A. CONTRACTOR SHALL BE RESPONSIBLE TO ASK FOR INSPECTIONS TO THE AUTHORITIES HAVING JURISDICTION, AS THE WORK PROGRESSES. ALL 5Y5TEM5 SHALL BE TESTED BY CODE AND /OR LOCAL REGULATIONS. B, DRAINAGE PIPING, BEFORE INSTALLATION OF ANY DRAIN$, THE ENDS OF SYSTEMS SHALL BE CAPPED AND ALL LINES FILLED WITH THE WATER TO THE HIGHEST POINT AND ALLOWED TO STAND UNTIL. INSPECTION IS MADE BY AN OWNER REPRESENTATIVE, 13. STERILIZE ALL WATER LINES WITH A MIXTURE OF TWO (2) POUNDS OF CHLORINATED LIME TO EACH 1.000 GALLONS OF WATER (50 PPM OF AVAILABLE CHLORINE). RETAIN MIXTURE IN PIPES 24 HOURS AND FLUSH THOROUGHLY WITH POTABLE WATER BEFORE PLACING IN SERVICE, 14. COMPLETE SYSTEM, FIXTURES AND EQUIPMENT SHALL BE GIVEN AN IN- SERVICE TEST AFTER COMPLETION OF THE INSTALLATION. ro"O 2ro CAA, ROOF CAP.... --.,- -\ c2AGi� KITCHEN COOK H XHAU T RISER N,T.S. AIR CONDITIONIN CHEDUL MANUFACTURER NOM. NOM. ESP IN, ELECT, TOTAL TOTAL COOLING CAP, 6/T O/A DIMENSIONS WEIGHT ELECT. SERVICE SUCTION LIQUID UNIT R AND MODEL NO, TONS CFM uJG, HEAT KW FLA /HP MCA/MO- BTUH 0 95° 4 9, 1` W CFM WxLxH (IN.) LBS. VOLTS /P H /Hz LINE LINE AHU TRANE - TWra030A14OB --- 1000 .40 5 2.0 1/4 - _ - _ - - - - - - - 24 x 21 x 52 110 205 -230/1 /(oO 12,00 --- - - - C1U TRANE- 2TTB2030AI000A 2,5 - -- - - -- - - -- - - -- i 30 20,600/2,3,000 - -- 21�X2(OX21B 160 208 - 230 /1 /(oO EF"2 1 -1 /S 3/0 AHU TRANE- TU,1Cx048A1405 --T Iro00 ,40 10 3.5 1/ _ -__ __ 22 x 21 x 43 131 208 -230/1 / sa 12.00 - -- DAMPER 4 ROOF CAF' _ CU 02 #3 TRANE- 2TTB2045AIOOOA 4 --- - - _ _ - - _ - _ _ 2ro 45 34,400/4i,500 --- 33X30X37 21 205- 23011100 3/4 5/10 HVAC DESIGN REQUIRES: Y E 5 NO DUCT SMOKE DETECTOR MANUFACTURER x FIRE DAMPER (5) WEIGHT x SMOKE DAMPER($) 0,LxH (IN.) x FIRE RATED ENCLOSURE NUTONE /1-5-50 x pII E RATED ROC 5/FLOOPw CEILING AS6EMf31_Y �50 * 1/5" x FIRE STOPPING - -- x SMOKE CONTROIL x Q) PIPE IN.SUL,, /mmCO11DEN61NG '0� UNIT "4CRETE PAD THICK MIN HVAC LEC_iI= D TO AIR HANDLIER 30� "Xl. "L . Tr4P -CON6, OR LAG BOLTS W1 SHIELDS INSIDE ALL AHUe TO WITH eAME MODEL THRU CEILING SPACE C. UNIT THRU 5,43E P1_,4TE TO WITH&T,4NF-) WIND& COVER, 14ro MPH WITH SUPPLY AIR DIFFUSER 4N ,4NCHOR 5OLT OF 500 POUNDS MINIMUM PULL OUT CAF,4CIT1T'. RETURN AIR GRILLE ON N I UNIT OT THERMOSTAT A 14 INi ION _TAIL SUPPLY AIR DUCT RECTANGULAR CROSS SECTION NO 6CALE -�' RETURN AIR DUCT RECTANGULAR CRO55 SECTION _I'/211 MIN. TURNING VANE � STRAP, 26 C,z. SUPPLY DUCT-7 ,. -� VOLUME DAMPER, IN LINE 1UO03 SCREW — MECHANICALLY ATTACH_ `ip VOLUME DAMPER, AT TAKE OFF R /,LS, -► j-)UJGT ` " WOOD JOIST WHEN APPLY � � / � CONNECT I NLEXI�LE � (�, REFRIGERANT LINES � ��i FLEXIBLE ROUND DUCT TO OUTSIDE CONDENSING UNIT THRU ATTIC SPACE 1 � 5PL ITTER PAMPER ROUND OPEN DUCT HANGER STRAW FLEX FLEX DUCT. 11/ /211 22G IN CLOSET n \—CEILING 0 FAN 3/4" CONDENSATE DRAIN w/ 3" TRAP I – PARTITION DUCT PRESSURE A -- —A FIRE DAMPER UNION AND C,O TO , GREEN AREA I I PERFORATED CAP FOR -VENT, 12 HIGH OS SMOKE DETECTOR I I _0 1t k s� OPPOSED BLADE DAMPER GALV. STEEL I I —SECONDARY FOR DUCTS OVER A.H.U. SUPPORT DR AIN WIDE, FASTEN UNDER J_j (SELF- $TANDING) --o,,, I I 15OTTOM OF DUCT �J ELECTRIC STRIP HEATER NO COMBUSTIBLE-----, I I PROV13 411 CLEARANCE M A.H.U. RIAL5"( WITHIN � � � I � ALL AROUND AHU MOTORIZED DAMPER R/A THRU I i '' DRAIN PAN DUCT HAND INC; DETAIL. LOU R POOR `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roO% HEATING - 10 DB 41° - DB 4, ALL FAN UNITS, MOTORS, COMPRESSORS, ETC. SHALL BE ISOLATED, AS REQUIRED TO OPERATE QUIETLY 50 THAT NOOBJECTIONABLE SOUND WILL BE HEARD IN THE HABITABLE SPACES DUE TO AIR VELOCITY, MOTOR HUM, VIBRATION, OR MECHANICAL MOVEMENT. 5. A/C SYSTEM SHALL HAVE CLEANABLE AIR FILTERS LOCATED AS REQUIRED FOR EASY ACCESSIBILITY. (o. A/C SYSTEM SHALL BE CONTROLLED BY A THERMOSTAT. MOUNT THERMOSTAT 5' -011 ABOVE FINISHED FLOOR, U.O.N. 1 ALL GRILLS AND DIFFUSERS TO BE ALUMINUM OR STEEL CONSTRUCTION. DIF- FU5ER5 TO HAVE OP05EP BLADE DAMPERS. PROVIDE GASKETS ON ALL GRILLES AND DIFFUSERS. TITUS OR AIREnUIDE OR APPROVED EQUAL WHiTH ENAMEL FINISH S. UNDERCUT DOORS 111 A.F.F., FOR R/A FOR ROOMS WITH LE55 THAN 110 CFM FOR ROOMS WITH OVER 110 CFM PROVIDE RAG. AND TRANSFER DUCT, 9, ALL REFRIGERANT PIPING SHALL. BE COPPER - TYPE L - ACR TYPE, DEHYDRATED AND SEALED. ALL FITTINGS SHALL BE WROUGHT COPPER. ALL JOINTS SHALL BE MADE WITH HIGH TEMPERATURE BRAZING ALLOY OF NOT LE55 THAN 5% SILVER. PIPING INSTALLATION NOT LESS THAN 3/4" THICK "ARMAFLEX ", LIQUID AND SUCTION LINES SHALL BE SIZED ACCORDING TO EQUIPMENT MANUFACTURER'S RECOMMENDATIONS FOR EQUIVALENT LENGTH OF PIPING RUN FOR CONNECTED TONNAGE, ALL PIPING ACCES50RIE3 SHALL BE CONSTRUCTED A$ SUGGESTED BY EQUIPMENT MANUFACTURER. ALL PIPING SHALL BE (EVACUATED PER GOOD PIPING PRACTICE BEFORE START -UP. SEAL JOINT U EPDXY 4 DU( 2 "A /C C.D. UNDERSLAB 4IR HANDLER UNIT IN5TALLATI N DETAIL NO SCAIL AIR FLOW 2nd. FLC CEILING SP CLG, DUCT 51ZE . FAN SCHEDULE MAX. SPACING UP THRU 2 S,F. MANUFACTURER UJATT ELECT, SERVICE D1MEN51ON5 WEIGHT FAN " AND MODEL NO. I"` HP CFM SP. VOLTS/PH/Hz /Hz 0,LxH (IN.) L5$, REMAi S 9CiN v EPI NUTONE /1-5-50 - -- `4" �50 * 1/5" 12x1Ox8 - -- 1U /GRILLE, 4 "d DUCT S/M f1y3 Q) DAMPER 4 ROOF CAF' EF"2 NUTONE / QT -130 - -- 13O w I /g" I2A /I /4aO � lrrvxl2xlo _ -- W /GRILLE, 6"4 DUCT 5/M � 20 DAMPER 4 ROOF CAF' PIPE IN.SUL,, /mmCO11DEN61NG '0� UNIT "4CRETE PAD THICK MIN HVAC LEC_iI= D TO AIR HANDLIER 30� "Xl. "L . Tr4P -CON6, OR LAG BOLTS W1 SHIELDS INSIDE ALL AHUe TO WITH eAME MODEL THRU CEILING SPACE C. UNIT THRU 5,43E P1_,4TE TO WITH&T,4NF-) WIND& COVER, 14ro MPH WITH SUPPLY AIR DIFFUSER 4N ,4NCHOR 5OLT OF 500 POUNDS MINIMUM PULL OUT CAF,4CIT1T'. RETURN AIR GRILLE ON N I UNIT OT THERMOSTAT A 14 INi ION _TAIL SUPPLY AIR DUCT RECTANGULAR CROSS SECTION NO 6CALE -�' RETURN AIR DUCT RECTANGULAR CRO55 SECTION _I'/211 MIN. TURNING VANE � STRAP, 26 C,z. SUPPLY DUCT-7 ,. -� VOLUME DAMPER, IN LINE 1UO03 SCREW — MECHANICALLY ATTACH_ `ip VOLUME DAMPER, AT TAKE OFF R /,LS, -► j-)UJGT ` " WOOD JOIST WHEN APPLY � � / � CONNECT I NLEXI�LE � (�, REFRIGERANT LINES � ��i FLEXIBLE ROUND DUCT TO OUTSIDE CONDENSING UNIT THRU ATTIC SPACE 1 � 5PL ITTER PAMPER ROUND OPEN DUCT HANGER STRAW FLEX FLEX DUCT. 11/ /211 22G IN CLOSET n \—CEILING 0 FAN 3/4" CONDENSATE DRAIN w/ 3" TRAP I – PARTITION DUCT PRESSURE A -- —A FIRE DAMPER UNION AND C,O TO , GREEN AREA I I PERFORATED CAP FOR -VENT, 12 HIGH OS SMOKE DETECTOR I I _0 1t k s� OPPOSED BLADE DAMPER GALV. STEEL I I —SECONDARY FOR DUCTS OVER A.H.U. SUPPORT DR AIN WIDE, FASTEN UNDER J_j (SELF- $TANDING) --o,,, I I 15OTTOM OF DUCT �J ELECTRIC STRIP HEATER NO COMBUSTIBLE-----, I I PROV13 411 CLEARANCE M A.H.U. RIAL5"( WITHIN � � � I � ALL AROUND AHU MOTORIZED DAMPER R/A THRU I i '' DRAIN PAN DUCT HAND INC; DETAIL. LOU R POOR `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roO% HEATING - 10 DB 41° - DB 4, ALL FAN UNITS, MOTORS, COMPRESSORS, ETC. SHALL BE ISOLATED, AS REQUIRED TO OPERATE QUIETLY 50 THAT NOOBJECTIONABLE SOUND WILL BE HEARD IN THE HABITABLE SPACES DUE TO AIR VELOCITY, MOTOR HUM, VIBRATION, OR MECHANICAL MOVEMENT. 5. A/C SYSTEM SHALL HAVE CLEANABLE AIR FILTERS LOCATED AS REQUIRED FOR EASY ACCESSIBILITY. (o. A/C SYSTEM SHALL BE CONTROLLED BY A THERMOSTAT. MOUNT THERMOSTAT 5' -011 ABOVE FINISHED FLOOR, U.O.N. 1 ALL GRILLS AND DIFFUSERS TO BE ALUMINUM OR STEEL CONSTRUCTION. DIF- FU5ER5 TO HAVE OP05EP BLADE DAMPERS. PROVIDE GASKETS ON ALL GRILLES AND DIFFUSERS. TITUS OR AIREnUIDE OR APPROVED EQUAL WHiTH ENAMEL FINISH S. UNDERCUT DOORS 111 A.F.F., FOR R/A FOR ROOMS WITH LE55 THAN 110 CFM FOR ROOMS WITH OVER 110 CFM PROVIDE RAG. AND TRANSFER DUCT, 9, ALL REFRIGERANT PIPING SHALL. BE COPPER - TYPE L - ACR TYPE, DEHYDRATED AND SEALED. ALL FITTINGS SHALL BE WROUGHT COPPER. ALL JOINTS SHALL BE MADE WITH HIGH TEMPERATURE BRAZING ALLOY OF NOT LE55 THAN 5% SILVER. PIPING INSTALLATION NOT LESS THAN 3/4" THICK "ARMAFLEX ", LIQUID AND SUCTION LINES SHALL BE SIZED ACCORDING TO EQUIPMENT MANUFACTURER'S RECOMMENDATIONS FOR EQUIVALENT LENGTH OF PIPING RUN FOR CONNECTED TONNAGE, ALL PIPING ACCES50RIE3 SHALL BE CONSTRUCTED A$ SUGGESTED BY EQUIPMENT MANUFACTURER. ALL PIPING SHALL BE (EVACUATED PER GOOD PIPING PRACTICE BEFORE START -UP. SEAL JOINT U EPDXY 4 DU( 2 "A /C C.D. UNDERSLAB 4IR HANDLER UNIT IN5TALLATI N DETAIL NO SCAIL AIR FLOW 2nd. FLC CEILING SP CLG, DUCT 51ZE . HANGER SIZE MAX. SPACING UP THRU 2 S,F. 111/2" x 2(o G 1_011 2 THRU 4 5.F, 11 /211 x 1 /16" 4 THRU 10 S.F. 1'112 °` x 1/1&" OVER 10 S.F. 11 /a" x NOOK MANUFACTURER. ALL PIPINGS SHALL ESE EVACUATED PER GOOD PIPING PRACTICE E5EFORE 5TART -UP. LOW VELOCITY - -- --�* '' I -ems -- : _._ L...._I WALL CAP SUPPLY AIR DUCT - EXHAUST DUCT (NEE PLAN VIEW) INSUL R -6 METAL. ROUND FITTING: QUADRANT OPERATOR TO ESE OUTSIDE INSULATION PROVIDE INSULATION GUARD WHERE NECESSARY INSULATED FLEX. DUCT.' 11/2" F /Gz,WiTH POLYETHELENE JACK,ETAND STEEL. WIRE REINFORCING(R -o) AIR FLOW ADJUSTABLE VOLUME DAMPER SEAL JOINT WITH EPDXY 4 DUCT TAPE PERFORATED DIFFUSER TYFIC 4L D IFFU &ER CONNECTION DETAIL NO SCALE CLG. E XHAU &T FAN 4 UCT - E TA I L. N.T.S. ROOF CAP. BASE M - --.-.- -.–AIR FLOW S/M 26 G. SIZE DEPEND OF 'TYPE OF FAN SEE FAN SCHEDULE, EXHAUST DUCT ._/ EXHAUST FAN 4 DUCT-DETAIL N.T.S. -� JOB #: XXXXX GUERRERO /GONZALEZ ENGINEERS, INC. "lill 17 Michael C. Guerrero, P.E. wmwa Mechanical Eng. Lic. #15235 Rafael L. Gonzalez, P.E. Electrical Eng. Lic. #11057 4300 S.W. 73rd Avenue, Suite #107A Miami, Florida 33155 T0. (305) 262 -3944, Fax (305) 262 -8211 E —mail: PROJECTSOGUERREROGONZALEZENGINEERS .COM r— --- - - —. -. DAVID. STOTT " AI.JTMAN A .2 C H I T E C T 5880 SC, 7w 8T #f MIAMI, FLORIDA. 33143 305- 687 -0019 TEL 305 -669 -3102 FAX REVISIONS Q) Q) 4 <1 SEAL ~vim - ", z, a •a � ; � js I t 2� s r y'1J, r M1, r 4� curr /WATERH 8-- 24--04