10-531-007(a) (a) (a) (a) 120/240V PANEL "A" 200 M.L.O. 1 PH,3W SURFACE MTD BRANCH CIRCUITS LOCATION WIRE AND CONDUIT TOTAL BREAKER TRIP CKT NO. CKT NO, BREAKER TRIP TOTAL WIRE AND CONDUIT LOCATION V.A V.A PATIO LTG *14-1/2"C * 1P-15 1 2 1 P -20 1500 *12-1/2"C DINING REC. MAIDS BEDROOM WALL SWITCH 15A, 1.25V $3 600 FOUR WAY TOGGLE SWITCH 3 3 4 5500 (�� ✓ 1500 G. OPENER FAN APPLIANCES PATIO REC. F1L 5 6 2P (2000) 5 6 GARAGE C� 1500 600 APPLIANCES LIVING ROOM : 50 (2000) FOUNTAIN 7 3 1000 1500 9 10 FREEZER LIVING ROOM 3 #10- 1 /2 "C W.N. No,2 BEDROOM * 1P-15 10 12 30 1000 DISHWASHER BATH /ENTRY * 13 11 12 2500 3 #10- 1/2 "C 600 G. DISPOSAL ENTRY * 15 16 30 13 14 1 1500 MICROWAVE DINING /ENTRY 17 1i 2P 1000 #8`12- 1/2 "C 15 16 2B 6000 2*6, 1*8 RANGE KITCHEN /LTG 1M 20 20 1000 PUMP 17 13 60 6000 1 *8 GRD -1 "C FAMILY ROOM 21 22 2P 2750 3#10 -1/2 "C MIN W.H. No.1 1M 20 2P (3000) 2 *3- 3/4 "C C.U. *1 FAMILY ROOM 23 24 30 2750 21 22 40 (3000) LIVING ROOM 26 1 P -20 * *12-1/2"C BATH RECEPT. 23 24 2P 5500 2*4 -1 "C AHU 1 BATH REC. *12 -1 12 "C 11 * 1 P -20 25 26 60 5500 (10 KW) LAUNDRY 2S 1500 1 P -20 27 28 2P (2100) 2 *3 -3/4 "C C.U. 2 REFRIGERATOR 11 1500 1 P -20 29 30 40 (2100) POOL LIGHT BEDROOM *14-1/2"C * 1P-15 31 32 2B 5500 2*4 -1 "C AHU 2 BEDROOM * 900 1 P -20 33 34 60 5500 (10 KW) CORRIDOR * E00 35 36 3i SPACE PATIO * S00 37 33 39 40 SPACE SPARE 900 1 P -20 3M 40 !100 11 41 SPACE M00 1 P -20 41 42 * 2200 S.F. 6600 * 3700 S.F. 11100 SUBTOTAL 15,400 TOTAL = 46,600 31,200 SUBTOTAL 15,900 TOTAL = 5M,200 43,300 SUBTOTAL (a) AFCI C/B _DEMAND LOAD = 37.2 KW A/C @ 100 % = 4200 FIRST 10 KW @ 100 % = 10.0 KW HEAT @ 65% =7150 27,2 KW @ 40 % = 10.88 KW A/C (7.5 + 7.5) = 14,3 KW 35.18 KW (145A) 120/240V PANEL "B" 200 M.L.O. 1 PH,3W SURFACE MTD BRANCH CIRCUITS LOCATION WIRE AND CONDUIT TOTAL BREAKER TRIP CKT NO. CKT NO, BREAKER TRIP TOTAL WIRE AND CONDUIT LOCATION V.A V.A WASHER #812- 1 /2 "C 600 1P -20 1 2 2F 5500 2#4 -1 "C AHU No.3 G. OPENER WALL SWITCH 15A, 1.25V $3 600 FOUR WAY TOGGLE SWITCH 3 4 60 5500 (�� ✓ (10 KW) G. OPENER FAN 0J) * F1L 5 6 2P (2000) 2 *8- 3/4 "C CU No.3 GARAGE C� 600 7 : 50 (2000) FOUNTAIN 1000 9 10 2P 2750 3 #10- 1 /2 "C W.N. No,2 BEDROOM * 1P-15 11 12 30 2750 * 13 14 2P 2500 3 #10- 1/2 "C DRYER * 15 16 30 2500 W /GRD. * 17 1i 2P 1000 #8`12- 1/2 "C POOL MASTER BED * 1M 20 20 1000 PUMP * 21 22 2P 2750 3#10 -1/2 "C MIN W.H. No.1 * 23 24 30 2750 M. BATH LTG. * 25 26 1 P -20 * *12-1/2"C BATH RECEPT. TERRACES * 27 23 1 P -20 * BATH RECEPT. CORRIDOR * 2S 30 1 P -20 1600 WHIRPOOL BB Q. 900 31 32 1 P -20 600 POOL LIGHT SPARE Soo 1 33 34 SPACE 900 1 P -20 35 36 E00 37 3i S00 39 40 !100 11 41 42 * 2200 S.F. 6600 SUBTOTAL 15,400 TOTAL = 46,600 31,200 SUBTOTAL (a) AFCI C/B DEMAND LOAD = 35.6 KW (b) ON TIMER A/C @ 100 % = 4200 (c) GFI HEAT @ 65% =7150 FIRST 10 KW @ 100 % = 10.0 KW 25.6 KW @ 40 % = 10.24 KW A/C (7.15) = 7.15 KW 27.39 KW (114A) LEGEND w SPECIAL. RECEPTACLE OUTLET r- v I DUPLEX RECEPTACLE OUTLET 15A, 125V e- SIMPLEX RECEPTACLE OUTLET 15A, 125V O DUPLEX FLOOR RECEPTACLE, 15A, 125V © EXHAUSTFAN D COMBINATION FAN/ LIGHT 14 CEILING LIGHTING FIXTURE TV FLUORESCENT LIGHTING FIXTURE - SURFACE MTD. �/ WALL MOUNTED LIGHTING FIXTURE r- v I UNDER CABINET FLUORESCENT LIGHTING FIXTURE FLOOD LIGHT O CEILING MOUNTED LIGHTING FIXTURE © LIGHTING PANEL D FUSE OR DISCONNECT SWITCH 14 TELEPHONE OUTLET TV TELEVISION OUTLET SD SMOKE DETECTOR 0 HI -HAT opal PUSHIUTTON CHIME WALL SWITCH 15A, 1.25V $3 THREE WAY TOGGLE SWITCH FOUR WAY TOGGLE SWITCH ($4 LJ SAFETY DISCONNECT SWITCH / JUNCTION BOX (�� ✓ F FAN 0J) FAN AND LIGHT(3 -WIRE CKT) F1L GFI GROUND -FAULT INTERRUPTER WP WEATHERPROOF �ELECT{RICAL, MOTES 1, ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND ALL APPLICABLE LOCAL CODES. 2. COORDINATE ELECTRICAL SERVICE W/FLORIDA POWER AND LIGHT COMPANY. 3. ALL TELEPHONE RELATED EQUIPMENT PER TELEPHONE CO. AND AN6I/EIA/TIA -5'10 4, ELECTRICAL INSTALLATION DESIGN OF THIS PLAN IN IN COM- PLIANCE AS SET FORTH BY STATE OF FLORIDA STATUTES MODEL ENEf.SY EFFICIENCY CODES. 5. THE CONTRACTOR WILL EXAMINE THE JOB SITE AND DETERMINE FOR HIMSELF PRIOR t0 6U5MI5510N OF BID EXISTING CONDITIONS., 6. ALL ELECTRICAL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR IT WILL BE HIS RESPONSIBILITY TO SECURE AND PAY FOR ANY PERMITS, CERTICATE5 OF INSPECTION, A5 REQUIRED. 7. SUBSTITUTE MATERIALS EQUIPMENT OR METHODS SHALL NOT BE MADE WITHOUT APPROVAL OF THE ENGINEER IF THE U5E OF A SUBSTITUTE REQUIRES ANY CHANGE IN WORK. THE NECESSARY FOR SUCH CHANGE WILL BE 15ROUGHT TO THE ATTENTION OF THE ENGI- NEER AND IF APPROVED, SHALL BE MADE AT NO COST TO THE OWNER b. CLEAN UP $UCH TRASH AND DE15RI5 GENERATED BY THE WORK AND LEAVE COMPLETED WORK IN A CLEAN, UNDAMAGED, AND FINISHED CONDITION READY TO RECEIVE WITHOUT FURTHER PREPARATION, UNLESS SO SPECIFIED IN OTHER SECTIONS, ANY ADJACENT OR A15UTTING WORK TO BE PERFORMED BY OTHERS, 303/0 THILN (CU) -2 "C LOAD TABULATION DOUBLE LUGS PNL "A" = 145A (22000 A.LG.1 PNL PNL PNL "B" = 114A TYPICAL 4 � 25tA b) 240-0p 2 200 30350 MCM THWN (CU) 2 -1/2 "C I -5 /t" COPPE' GROUND ROD 10 FT. LONG WP (CU) - 3/4 "C !SER TS WP 303/0 THU,N ,106 (CU) - 2 "C 303/0, I0(o GIRD T" (CU) 2"C CWP (METAL) BLDG. STEEL FOUNDATION e, MATERIAL5, APPLIANCES, DEVICES AND EQUIPMENT SHALL MEET WITH THE REQUIREMENTS OF UNDERWRITERS' LABORATORIES AND SHALL BE NEW AND THE LATEST STANDARD PRODUCTS OF MANUFAC- TURERS REGULARLY ENGAGED IN THE PRODUCTION OF THE ITEM, UNLESS OTHERWISE INDICATED, LIKE ITEMS SHALL BE THE PRO- DUCT OF A SINGLE MANUFACTURER, 108 ALL CONDUCTORS SHALL BE COPPER AND RUN IN CONDUIT. WIRE SIZE SHALL BE THWN UNLE55 OTHERWISE NOTED ON PLANS. PROVIDE GROUND CONDUCTOR PER NEC ARTICLE 250 -122, 11. LOCATION OR OULETS IN ELECTRICAL DRAWINGS IS DIAGRAMMATIC: CHECK MANUFACTURER'S DRAWING FOR EXACT LOCATION OF OUTLETS. 12, PROVIDE TYPEWRITTEN SCHEDULES FOR ALL PANELBOARDS. 13. A/C EQUIPMENT WIRING, BREAKER AMC) FUSE SIZES ARE BASED ON A/C EQUIPMENT SPECIFIED ON ORIGINAL CONTRACT DRAWINGS. CON- TRACTOR IS RE5PON515LE FOR PROVIDING ALL WIRING, BREAKER AND FUSEE SIZES IN ACCORDANCE WITH A/C EQUIPMENT NAMEPLATE REQUIREMENTS IF DIFFERENT FROM THAT SPECIFIED ON DRAWINGS, AS WELL AS ANY FEEDER CHANGES BEING AFFECTED BY THIS CHANGE. CONTRACTOR SHALL MAKE ABOVE MENTIONED CHANGES AT NO EXTRA COST. HACR CIRCUIT BREAKERS MAY BE USED IN PLACE OF FUSES_ USE NON - AUTOMATIC SWITCH FOR A/C COND. DISCONNECT. (COMPLY W/NEC 110 -24) I4, ALL SMOKE DETECTORS TO BE INTERCONNECTED ON SAME CKT (AFCI PROTECTED) 15. RANGE AND DRYER SHALL HAVE BOTH NEUTRAL 4 GROUNDING WIRE PER NEC ARTICLE 250 -140, 16, ALL BEDROOM OUTLETS SHALL BE PROTECTED BY AN "ARC -FAULt CIRCUIT INTERRUPTOR"ZAFCD COMPLY WITH NEC 210,12(B) SMOKE DETECTOR—, I 'SWITCH SWITCH LEG, I- LINE 51DE 120V OF SWITCH PHASE CONDUCTOR 5MCKE DETECTOR CONNECTION DETAIL NT5, NQTEs: 1 -6MOKE DETECTOR SHALL BE HARDWIRED (110 VOLT TYPE) WITH BATTERY BACK -UP AND SMALL BE CONNECTED TO A BEDROOM CIRCUIT PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER, ALL SMOKE DETECTORS WITHIN EACH UNIT SHALL BE INTERCONNECTED(AFCI PROTECTED) 2 -6MOKE DETECTOR SHALL NOT BE PLACED WITHIN 3FT, OF ANY A/C GRILL, 3 -6MOKE DETECTORS LOCATED OUTSIDE OF SLEEPING AREAS SHALL NOT BE PLACED CL06ER THAN 3FT. TO BATHROOM DOOR, 4 -THE MOUNTING AND LOCATION OF UNIT SMOKE DETECTORS SHALL COMPLY WITH NFPA 12 5EC.2- 5216. CEILING;: MOUNTS NOT LESS THAN 4" FROM A WALL AND WALL MOUNTS AT LEAST 4" FROM CEILING AND NOT MORE THA 12" TO TOP OF DETECTOR ALL UJIF:INr_:� TO 5E FIEFLACEI) AND FLACEI:) IN CONDUIT AFF JOB #: XXXXX GUERRERO /GONZALEZ ENGINEERS, INC. Michael Guerrero, P. E, Mechanical Eny. Lic. #15235 Rafael L. Gonzalez, P.E. Electrical Eng. Lic. #11057 4300 S,W. 73rd Avenue, Suite #107A Miami, Florida 33155 TeL (305) 262 -3944, Fax (305) 262 -9211 E -mail: PROJECTSOGUERREROGONZALEZENGINEERS .COM i n 1% 1, 11 1 1 r, li 1 6865 S11 73 ,6T $4 MUMT, FLOIUDA 33143 305 - 687 -0811 TEL 305 -648 --6162 FAX REVISIONS U_ C� 0 curr /WATERH SEAL 8 -24 -04