14-1433-001I� I ��•
I
GLASS DESCRIPTION �
CASEMENT WINDOW, TYPE I:
GLAZING: 5/16" LAMINATED IMPACT RE515TANT GLA55
EXTERIOR LITE: 1/5" ANNEALED GLASS
.OqO" INTERLAYER OF DUPONT BUTACITE PVB
INTERIOR LITE: 1 /5" ANNEALED GLASS
AWNING WINDOW, TYPE I:
GLAZING: 5/16" LAMINATED IMPACT RESISTANT GLASS
EXTERIOR LITE: I/8" ANNEALED GLA55
.090 INTERLAYER OF DUPONT BUTACITE PVB
INTERIOR LITE: 1 /6" HEAT STRENGTHENED GLASS
HORIZONTAL ROLLER WINDOW, OPTION A:
GLAZING: 5/16" LAMINATED IMPACT RESISTANT GLA55
EXTERIOR LITE: I /8" ANNEALED GLASS
.090 DUPONT BUTACITE OR SAFLEX /KEEP5AFE MAXIMUN PVB INTERLAYER
INTERIOR LITE: I/V ANNEALED GLA55
FIXED WINDOW, OPTION A:
GLAZING: 7/16" NOMINAL LAMINATED GLA55
EXTERIOR LITE: 3116" ANNEALED GLASS
.090" PVB INTERLAYER
INTERIOR LITE; 3/16" HEAT STRENGTHENED GLA55
SLIDING GLASS DOOR, OPTION G3:
GLAZING: 7/16" LAMINATED IMPACT RE515TANT GLA55
EXTERIOR LITE: 3/16" HEAT STRENGTHENED GLASS
.090 DBPVB INTERLAYER (.Oqo DUPONT BUTACITE PVB)
INTERIOR LITE: 3/16" HEAT STRENGTHENED GLASS
WOOD FRENCH DOOR, OPTION A:
GLAZING: I" OVERALL THICKNESS IMPACT RESISTANT GLASS
3/16" TEMPERED GLASS
.10" INTERLAYER SAFETY -PLUS II BY 'GLA55LAM'
1/5" TEMPERED GLASS
3/8" AIR SPACE
1/5" TEMPERED GLA55
FRENCH DOOR, OPTION A:
GLAZING: 3/5" LAMINATED NOM. (.402 ") IMPACT RESI5TANT GLA55
EXTERIOR LITE: 1/8" ANNEALED GLA55 PLUS
.090 PVB INTERLAYER OF DUPONT BUTACITE OR SAFLEX /KEEP5AFE MAXIMUN PLUS
INTERIOR LITE: 3/16" HEAT STRENGTHENED GLASS
GENERAL NOTES:
I STORY BLDG. (13' 4' MEAN ROOF HEIGHT)
BUILDING CATEGORY: II
EXPOSURE "C"
ASSUME BUILDING FULLY ENCLOSED - ALL EXTERIOR OPENINGS ARE SHUTTERED OR IMPACT
175 M.P.H. HIND VELOCITY
ASD P =0.Gw
K. D. . 0,85
"END ZONES" IDRE55URE ARE APPLICABLE TO OPENINGS THAT ARE WITHIN: 5.2 FT. OF BUILDING CORNERS.
DESIGNED IN CONFORMANCE WITH ASCE 7 -10 WIND CODE
BASED UPON A MEAN ROOF HEIGHT t TRIBUTARY AREA AS SHOWN
THIS OFFICE: WILL NOT PROVIDE A LETTER OF COMPLIANCE OR INSPECTION REPORT UNLESS CALLED DURING INSTALLATION
CONTRACTOR TO VERIFY DIMENSIONS
PRODUCT CONTROL APPROVAL:
SERIES "CA -740" OUT5WING ALUMINUM CASEMENT WINDOW- IMPACT
BY P,G.T. INDUSTRIES
ACCEPTANCE #: 12- 1215.09
SERIES "AH -740" AWNING WINDOW- IMPACT
BY P.G.T. INDU5TRIE5
ACCEPTANCE #: 12- 1218,07
SERIES "HR -710" ALUMINUM HORIZONTAL SLIDING WINDOW- IMPACT
BY P.G.T. INDUSTRIES
ACCEPTANCE #: 11- 1114.04
5ERIE5 "PW- 701/720/820" ALUMINUM FIXED HINDOW- IMPACT
BY P.G.T. INDUSTRIES
ACCEPTANCE #: 13- 0502,03
SERIES "50-770" ALUMINUM SLIDING GLASS DOORS W /HO REINFORCEMENTS- IMPACT
BY P.G.T. INDUSTRIES
ACCEPTANCE #: 14- 0123.10
SERIES "CONDOR IMPACT" 5'0" OUT5WING GLAZED WOOD FRENCH DOORS W /WO SIDELITES- IMPACT
BY F.P.G. WHOLESALE, INC.
ACCEPTANCE #: 12- 0514.21
SERIES "FD -101" OUTSWING ALUMINUM FRENCH DOOR W /WO SIDELITES- IMPACT
BY P.G.T. INDU5TRIE5
ACCEPTANCE #: 12- 0516.02
NOTES:
I. WINDOW FRAMES / MULLION ANCHORAGE TO MAIN STRUCTURE
SHALL BE IN ACCORDANCE WITH THE UNIT'S NOTICE OF
ACCEPTANCE (REFER TO PRODUCTS CONTROLS).
2. ONLY THE OPENINGS THAT ARE IDENTIFIED WITH THEIR 51ZES AND
DESIGN PRESSURES ARE PART OF THI5 PERMIT. ALL OTHER
OPENINGS ARE NOT PART OF THI5 PERMIT,
3. THE MAIN WIND FORCE RESISTING SYSTEM OF THE STRUCTURE
(I.E.: BEAMS, COLUMNS, FRAMING, ETC.) SHALL BE DESIGNED TO
WITHSTAND THE LOADS POSED BY THE GLAZING. NO CALCULATIONS
HAVE BEEN PERFORMED TO VERIFY THEIR ADEQUACY.
4, EGRESS WINDOWS TO HAVE A MINIMUM OPENING AREA OF 5.7 50,
FT. (5.0 50. FOR GROUND FLOOR) (FBC 102q.2), AND 24" HEIGHT
MINIMUM, 20" WIDTH MINIMUM (FBC 102q.2.1)
5, EGRESS WINDOWS TO BE NOT MORE THAN 44" ABOVE THE FLOOR
(FBC 102013)
U_ C,
w '
EGRESS
EEP3 GRE55
CA3
LOAD TABLE FOR NINDONS AND DOORS
10/10/2014
DESCRIPTION
WIDTH
(Inches)
HEIGHT
(Inches)
TRIBUT.
AREA
(ScI k)
w
'
CONF.
DESIGN Pre55.
APPROVED Press
MANUF,
P.ATING
GLAZE
PRODUCT
APPROVAL
N.O.A.#
r`IK5.
+(psf)
--
41750
+ (psE)
L (Psf)
c
...J
8
r- _ cry
a
CAI
CASEMENT WINDOW
37
63
16.15
4
X
38.5
-42.19
70
-70.1
PGT INDUSTRIES
IMPACT
GLAZING TYPE I
12- 1218.Oq
CA2
CASEMENT WINDOW
III
63
16,18
4
XOX
38.5
-42.Iq
70
-70,1
PGT INDUSTRIES
IMPACT
GLAZING TYPE I
12-1218,09
CA3
AWNING WINDOW
53
38
13.g8
4
X
3q.15
- 42.57
70
-51.1
PGT INDUSTRIES
IMPACT
GLAZING TYPE 1
12- 1218.07
HRI
HORIZONTAL SLIDING WINDOW
53
35
6.99
4
XO
40.05
-43.44
75
-75
PGT INDUSTRIES
IMPACT
GLAZING OPTION A
II- 1114.04
HR2a
HORIZONTAL SLIDING WINDOW
74
50
12.84
5
XO
3q.4
-52.32
75
-75
PGT INDUSTRIES
II"IPACT
GLAZING OPTION A
II- 1114.04
HR3
HORIZONTAL SLIDING WINDOW
74
36
q.76
4
XO
40.05
-43.44
75
-75
PGT INDUSTRIES
IMPACT
GLAZING OPTION A
II- 1114,04
PHI
FIXED WINDOW
37
50
12.84
4
0
3q.4
-42.79
80
-80
PGT INDUSTRIES
IMPACT
GLAZING OPTION A
13- 0502.03
PHia
FIXED HINDOW
37
50
12.54
5
0
39.4
-52.32
50
-80
PGT INDUSTRIES
IMPACT
GLAZING OPTION A
13- 0502.03
PW2
FIXED WINDOW
53
37
13.61
4
0
3q.25
-42.64
50
-80
PGT INDUSTRIES
IMPACT
GLAZING OPTION A
13- 0502.03
PW3
FIXED WINDOW
74
38
19.52
4
0
35.31
-41,7
50
-80
PG,r INDUSTRIES
IMPACT
GLAZING OPTION A
13- 0502.03
PW4
FIXED WINDOW
37
35
q.76
4
0
40.05
-43.44
80
-80
PGT INDU5TRIE5
IMPACT
GLAZING OPTION A
13- 0502.03
SDI
SLIDING GLASS DOOR
72
80
20
4
XX
38.24
-41.64
46.67
--60
PGT INDUSTRIES
IMPACT
GLAZING OPTION G3
14- 0123.10
SDIa
SLIDING GLA55 DOOR
72
80
20
5
XX
35,24
-50.02
46.67
-60
PGT INDUSTRIES
IMPACT
GLAZING OPTION G3
14- 0123.10
FDI
WOOD FRENCH DOOR
60
80
16.66
4
XX
38.72
-42.11
60
-60
F.P.G. WHOLESALE
IMPACT
GLAZING OPTION A
12- 0514.21
FD2
FRENCH DOOR
26
80
14.44
4
X
3q.Oq
-42.49
75
-75
PGT INDUSTRIES
IMPACT
GLAZING OPTION A
12- 0516.02
V V U V U U V V V
y V V V
V V U V
V
V V U U U V V J V U
VVVJ VJVUJ VUU
V U V
U V V V U
U U
U
yUJV V yVVUV V VUV
FRONT ' yTHIS PERMIT FLOOR PLAN
SCALE: 114 " =L0"
Lam.
'ART
CIS
IT
y '-DATE:
10/10/2014
SCALE:*:
AS SHOWN
�J y -
OB 01-- 210 - 100614
CONTENT:
WIRQWS INSTALLATION
uj
SHE=ET
V V
VVV V
DRAWN BY
c
A
a.a, drafting
services, Inc.
aadsCbellsouth,net
@gyp.;
;
uj
c
A
Ca
UJ
c
...J
8
r- _ cry
a
o
C
[ ,'
E
cc
U
�
c
"� c�
E
d6
@gyp.;