14-522R-002� , I I � � I I Z I wl 4 "0 GMD (26 GA) ` EF -1 zl THRU WALL W /CAP i \� :J _J J (LOW ON WALL) ; �� MAS ER BATH I m 1 0 6X6, 1 W`,— - 30 CFM W' I. C. I I MASTER BEDR00 8"0 12x8, 1 W 180 CFM LAUNDRY 4" 0 12X12 RAG 10" 0 10" EP I ,,,, _00 O O REF. LINES _ — �� 0 10X8, 1W EN I cu #1 °" r— KS 14C CFM oO 6 % I °. KITCHEN REF I I 6% I I Dw 10X8, 1W 125 CFM DINING ROOM 14X14 RAG 8 "0 1 � 1 i n FAMILY ROOM 10X8, 1W 100 CFM I „0 0 10X8, 1W 100 CFM I BEDROOM II 10X8, 1 W I 8 "0, 125 CFM I 8 „4 I _ 17� 12 10 "i r RAG EXG. METER HVAC SYMBOL LEGEND SYMBOL DESCRIPTION ® SUPPLY DUCT X RETURN /EXHAUST DUCT — FLEXIBLE DUCT SMOKE DAMPER(S) ELBOW W/ TURNING VALVES REF, S &R REFRIGERANT SUCTION & LIQUID LINES — CEILING EXHAUST FAN FIRE RATED ROOF /FLOOR CEILING ASSEMBLY EXHAUST REGISTER OTHERMOSTAT FIRE STOPPING — X: AIR DEVICE TYPE AXB O #CFM # AXB: NECK SIZE UC DOOR UNDER -CUT 1" min. CU CONDENSING UNIT SA SUPPLYAIR CFM CUBIC FEET PER MINUTE FCU FAN COIL UNIT EF EXHAUST FAN NOTE: CONCRETE CREWS SHALL BE RATED FOR 500 LBS. MIN. PULL —OUT CAPACITY. CONDENSING UNIT POWER & CONTROL CONNECTIONS 6" MIN. 6" MIN. O 1— 4" MIN. LIQUID LINE FASTEN C.U. TO CONCRETE W/O INSULATION PAD USING (4) 1/4" CONCRETE SCREWS WITH 1.5" EMBEDMENT MINIMUM AS PER MFG. CERTIFIED DATA. PROVIDE (4) 1/2" 6" MIN. SUCTION LINE W/ 1/2" ISOMODE PADS AT EACH SCREW ARMAFLEX INSULATION CONCRETE BASE W/ & VAPOR BARRIER 6 X 6 — 10/10 WWF CONDENSING UNIT MOUNTING DETAIL N.T.S. SUPPORT FROM 1 1/2 X 26 GA. GALV. UNDERSIDE OF STEEL HANGER STRAP STRUCTURE. (5' O.C.) i AIR DUCT (SEE PLAN VIEW) �� BATH LOW FRICTION LOSS 4% GMD (26 GA) _ EF -1 I I THRU WALL W /CAP BRANCH TAKE —OFF FITTING 10 "o (LOW ON WALL) METAL ROUND FITTING QUADRANT OUTSIIDE ULATION TO BE PROVIDE INSULATION GUARD WHERE NECESSARY AIR FLOW A #1 12X12 SEAL JOINT W/ 6' MAX. RAG DUCT SEALER AND TAPE NEW AHU 1 TYPICAL EXH U ST FANS (4 TONS) AIR FLOW I Z EF -1 = BROAN MODEL #688 @ 120V / 1 PH / 60 HZ INSULATE TOP INSULATED FLEX. DUCT 1/4" SP 50 CFM W/ BACKDRAFT DAMPER OF DIFFUSER. BAND OF SAME SIZE AS HANGER STRAP 8.10 BEDROOM I SEAL JOINT WITH DUCT I li TAPE SEALER AND 10X8, 1 W 140 CFM K i 8 0 I 1 12X8, 1 W 200 CFM LIVING ROOM 0 Mechanical Plan 1/4 ” MECHANICAL NOTE: EXG. AIR HANDLER AND CONDENSER UNIT TO BE REPLACED WITH NEW UNITS OF EQUAL OR BETTER EFFICIENCY ALL EXG. DUCTS TO BE REMOVED AND REPLACED WITH NEW DUCTS OF EQUAL SIZE. ALL SUPPLY GRILLES TO BE REPLACED W/ NEW OF EQUAL SIZE. DIFFUSER W/ OPPOSED / �V BLADE DAMPER ADAPTOR ROUND TO SQUARE IF REQUIRED FLEXIBLE DUCT CONNECTION DETAIL N.T.S. HVAC DESIGN REQUIRES: YES NO DUCT SMOKE DETECTOR — X FIRE DAMPER(S) — X SMOKE DAMPER(S) — X FIRE RATED ENCLOSURE — X FIRE RATED ROOF /FLOOR CEILING ASSEMBLY — X FIRE STOPPING — X SMOKE CONTROL — X DUCT TURNING VANES FOR SMACNA STANDARDS. TYPICAL 90- DEGREE VANED ELBOW DETAIL. WOOD JOIST & DECK. \SCREWS FASTENERS HANGER WIRE 12 GAUGE (MIN.) — DUCT SHEET METAL CHANNEL SUSPENDED CEILING (SEE ARCH. DRAWINGS) DUCT HANGER DETAIL N.T.S. PROVIDE SWITCH IN UNIT OVERFLOW OUTLET WIRED TO SHUT DOWN UNIT WHEN WATER IS MECHANICA SEE CONNE DETAIL. PROVIDE 3'– IN FRONT OF AND HEATER 2 "X 2 "X 1 / NEOPRENE[ CORNERS PROVIDE 4" CLEAR ALL AROUND UNIT 2" x 2" x 1/4 STEEL ANGLE FRAME SHALL BE RUST PRIME PAINTED. – 3X3X3/16" STEEL ANGLE PLATE. VERTICAL AHU MOUNTING DETAIL N.T.S. HVAC NOTES 1. GENERAL A. DRAWINGS: Refer to all drawings for coordination of the -HVAC work. B. ARRANGE AND PAY for all permits licenses, inspections onlx test:,. _ Obtain the required certificates and present to owner. C. GUARANTEE: The completed installation shall be fully guaranteed against defective materials and /or improper workmanship for a minimum of one year for material and labor. Compressors shall be guranteed for a period of five years. D. As built drawings shall be submitted to owner at the completion of project. 2. SHOP DRAWINGS: Contractors shall submit for approval, within 30 days after signing contract, a minimum of five copies of fully descriptive literature, including but not limited to: fans, air conditioning units, air outlets. No work shall proceed without approval of these submittals. 3. DESIGN PARAMETERS: A. Outdoor design temperature (Summer): 91'F DB and 797 • WB B. Outdoor design temperature (Winter): 457 C. Indoor design temperature (Summer): 787 DB D. Indoor design temperature (Winter): 727 DB 4. ALL THERMOSTATS SHALL have heating mode maximum setting of 75 F, and cooling mode minimum setting of 70 F. The thermostat shall be arranged to prevent the simultaneous operation of heating and cooling. 5. ELECTRICAL CONTROLS AND POWER WIRING: Under electrical contract. 6. EQUIPMENT SPECIFIED BY manufacturer's number shall include all accessories, controls, etc., listed in the catalog as standard with the equipment. Optional or additional accessories shall be furnished as specified. 7. MATERIALS: A. REFRIGERANT PIPING: Shall be type L soft drawn, copper tubing, dehydrated for refrigerant use. Sized as shown on drawings or as per air conditioning equipment manufacturer's recommendations. B. INSULATION: Refrigerant suction piping shall be insulated with 1/2" thick foamed plastic insulation, fire retardant type. Insulation shall be installed in piping before assembly. No split insulation will be acceptable. Seal joints with manufacturer's approved adhesive and grey tape. C. DUCTWORK: a. All supply air ductwork shall be fiberglass ductboard, fabricated and installed as per latest edition of SMACNA Fibrous Glass Duct Manual". 1 -1/2 thick R -6.0 in uncond. space. 1" thick R-4.2 in cond. space. b. All exhaust ductwork shall be galvanized sheet metal duct not lighter than 26 gage. C. All duct dimensions are clear inside dimensions. d. Flexible insulated ductwork with 1 1/2" thick fiberglass insulation with FRK vapor barrier, class I air duct, U.L. R -6.0 MIN. e. Dryer ductwork: 26 ga. min. galvanized steel, having a smooth interior surface with joints running in the direction of airflow and without sheet metal screws or other fasteners in the air stream. Maximun length shall not exceed 25 feet. wall caps shall be provided with backdraft damper. 8. Provide metal round fittings at all flexible duct connection to supply duct. 9. TEST AND BALANCE: Contractor shall test and balance all ventilation and air conditioning systems. Submit four copies of Test and Balance Report to owner for approval. 10. CONTROLS: Air conditioning units shall be started and stopped thru individual thermostat. Individual thermostats shall start /stop supply fons and activate cooling /heating systems as selected. 11. Mechanical plans in general, are diagrammatic in nature, and are to be read in conjuction with arch. Plumbing, electrical and structural plans and shall be considered as one set of documents. Duct and piping offsets, bends and transitions will be required to provide and install a complete functional system and shall be provided by the contractor at no additional cost to the owner. 12. Contractor shall verify job conditions prior to ordering, fabrication or installation of materials or equipment. Notify architect /engineer of any conflicts before fabrication. SPLIT SYSTEM SCHEDULE UNIT NO. UNIT 1 TOTAL CAPACITY BTU /HR 48,000 SENS CAPACITY BTU /HR 35,700 CFM SUPPLY 1,600 HEATER KW 10 RLA: 26.9/26.9 C.U. FLA 2.8 MCA 37/37 VOLTAGE 1 -60 -240 MANUFACTURER CARRIER AHU MODEL FB4CNF 048 C.U. MODEL CA13NA 048 SEER 13.0 WEIGHT 157 LBS MIN. DUCT INSULATION SHALL BE R -6 FOR A/C DUCT IN NON AIR CONDITIONING SPACES NOTES: 1. PROVIDE PROGRAMMABLE THERMOSTAT. 2. FAN COIL UNIT SHALL BE PROVIDED WITH FACTORY INSTALLED CIRCUIT BREAKER. 3. PROVIDE SEA –COAST PROTECTION ON ALL CONDENSING UNITS COIL AND CASE. 2 c Z y i x' h i .M