Loading...
14-522-004. . . NEW MASONRY (LOCK WALL ••• '•• I EXIST. CONC. TIE SEAM • • • • 1 TOP OF PLATE • 0 r • Li 2 "X4° CONT. WOOD BACKING CEILING: LINE (REFER TO FL. PLAN I IN BETWEEN STUDS. •••• •r••• FOR CEILING HEIGHT) • • SEE TYPICAL WALL SECTION I l • ' 3 -5/b" TOP RUNNER r • r • • • • • • (20 GA.)ATTACH TO STRUCTURAL ELEMENT :.• I _ I I ...................................... . x 20 9 METAL STUDS AT 16" O-G. 8" C.M.U. WALL 1/2" GYPSUM DRYWALL ON EACH I SIDE OF PARTITION- APPLY 3 5/8 20 GA. OR 5 5/8 ' ....:....... . ....: _. - -- __. 1/2" DRYWALL 1/2" DRYWALL DRYWALL W/ LONG DIMENSION CHANNEL SHAPE STUDS PARALLEL TO STUDS, A WITH „ SELF DRILLING TYPE 'S' GYPSUM C� 16 O.C. DRYWALL SCREWS, V LNG. FOR �+ 1/2 4 5/15 THIC BOARD. SPACED I x 4 WD. P.T. BACKING NOT MORE THAN 12" O.C. ALONG I - . . • • EA. SIDE EXIST. OPENING r - :: 2 x 4 WD. BACKING AT 33 1/2" A50VE SUPPORTS FOR 130TH WALLS �? j� :. .; ;'. i5 OF AT 33 1r1" AB01/E FINISH FLOOR G NG EILI5 00 I o0 FINISH FLOOR TOP OF PLATE 3 -5/8" * 16" OiC. EXIST. FOOLING (2m CsA) 2 " "X4" CONT. WOOD BACKING .: :. _- - E IN BETWEEN STUDS. 3 -5/8" E3OTTOM CHANNEL (25 CAA.) SECURED TO - - SLAB W/ 3/1611 0 TAPCONS CD 7/7 AT 16" O.G. (TYPJ 33 1/2" ABOVE 33 1/2" ABOVE WOOD BASE FINISH FLOOR FINISH FLOOR TOP OF CONCRETE 'SLAB ELEV. 0' -0" SEE ARCH. DWG. FM, FLOOR FIN. FLOOR 1. DRILL & EPDXY #5 FOR MINIMUM OF 6" INTO EXISTING T.I. ✓k FTG. is FILL SOLID W/ 3,000 F.S.I. GROUT. (USE HILLL C -10 EPDXY). 2. USE HORIZONTAL REINFORCING #9 GAUGE LADDER TYPE EVERY OTHER COURSE. BATHROOM BACKING DETAIL METAL STUD PARTITION DETAIL 3 KITCHEN CABINET BLOCKING DETAIL 4 BLOCKING UP EXISTING OPENING DETAIL 1 � N.T.S. N.T.S. .. N.T.S. N.T.S. ELECTRONIC WATER HEATER SCHEDULE UNIT DESIGNATION ELECTRONIC TANCLE55 WATER HEATER MANUFACTURER TITAN MODEL No. N -120 EN =lrsY EFFICIENCY UP TO 55" VOLTAGE 220 VAC STD. (208/2 -M AVAIL - MAX. AMPS AT 220 V 54 MAX. Kill AT 220 V Ili STANDARD AN81 -Z. 1003 DIMENSIONS 10" X 7 X 3" WEIGHT 5 POUNDS MATERIALS BRASS CASING PIPE FITTING 1/2" STANDARD PIPE PRE55URE S PSI- MIN1I50 f%I -MAX. DUAL INC12LOY/NIC14RalE —ELEMENTS L0rATi,_'*4 UTILITY PDOM/ BATH IV UNDER COUNTER PROVIDE W /P. CAP LOW PROFILE B.D.D. AT ROOF STRUCTURE TOP FOR BATHROOM PROVIDE INSECT SEE ARCHITECTURAL SCREEN OOFING CONTRACTOR TO SUPPLY WATER PROOFING, AS PER VENT MOUNT. DETAIL is RECOMMENDATION. 4 -16d NAILS 2' THRU PLYWOOD P� Uv UCT FROM UNI1= -�"- WALL SEE PLAN FOR SHEET LINO. A -3 OF .:aw, 7" o O ❑ rTITANN-120 H.W. TO FIXTURES WARNING HOT WATER ELECTRONIC TANKLESS WATER HEATER FROM sERwcE COLD WATER INSTANT WATER HEATER DETAIL IZE TYPE �:v I I I 50 ELBOW CAP ASSEMBLY FAN IN--�/ CEILING G TYP, ROOF CAP DETAIL TOILET EXHAUST NOT USED 8 NOT USED N:T,S: 6 N.T.S. 7 N.T.S. N.T.S. r'• f NOT USED NOT USED 11 NOT USED 12 NOT USED O N. T.S. N,TN.T.S. N.T.S. N.T.S. SHEET LINO. A -3 OF .:aw,