Loading...
11-1075-013GENERAL PLUMBING NOTES: 1. ALL WORK SHALL CONFORM WITH ALL LOCAL, STATE, FEDERAL ORDINANCES AND BUILDING CODES GOVERNING THE INSTALLATION OF THE PLUMBING SYSTEM. IF WORK AS LAID OUT, INDICATED OR SPECIFIED IS CONTRARY TO OR CONFLICTS WITH LOCAL ORDINANCES, BUILDING CODES AND REGULATIONS, THE CONTRACTOR SHALL REPORT IN WRITING TO THE ARCHITECT /ENGINEER BEFORE SUBMITTING A BID. THE ARCHITECT /ENGINEER WILL THEN ISSUE INSTRUCTIONS AS HOW TO PROCEED, 2. THE DRAWINGS ARE TO BE CONSIDERED DIAGRAMMATIC, NOT NECESSARILY SHOWING IN DETAIL OR TO SCALE ALL OF THE MINOR ITEMS. UNLESS SPECIFIC DIMENSIONS ARE SHOWN, THE STRUCTURAL, ARCHITECTURAL AND SITE CONDITIONS SHALL GOVERN THE EXACT LOCATIONS. CONTRACTOR SHALL FOLLOW DRAWINGS IN LAYING OUT WORK, CHECK DRAWINGS OF ALL TRADES TO VERIFY SPACES IN WHICH WORK WILL BE INSTALLED AND MAINTAIN MAXIMUM HEAD ROOM, AND SPACE CONDITIONS AT ALL POINTS. WHERE HEAD ROOM, OR SPACE CONDITIONS APPEAR INADEQUATE, ARCHITECT/ ENGINEER SHALL BE NOTIFIED BEFORE PROCEEDING WITH INSTALLATION. THIS CONTRACTOR SHALL, WITHOUT EXTRA CHARGE, MAKE FIELD MODIFICATION IN LAYOUT AS NEEDED TO PREVENT CONFLICT WITH WORK OF VARIOUS TRADES OR FOR PROPER EXECUTION OF THE WORK . 3. EXAMINE ALL DRAWINGS CAREFULLY PRIOR TO SUBMITTING A BID. CONTRACTOR WILL BE REQUIRED TO FURNISH, INSTALL AND /OR CONNECT WITH APPROPRIATE SERVICES ALL PLUMBING ITEMS SHOWN ON ANY OF THE ARCHITECTURAL, AIR CONDITIONING, ELECTRICAL AND SPRINKLER DRAWINGS WITHOUT ADDITIONAL EXPENSE TO THE OWNER. IF DISCREPANCIES , CONFLICTS , INTERFERENCE OR OMISSIONS OCCUR BETWEEN DRAWINGS, NOTIFY IN WRITING THE ARCHITECT/ ENGINEER IN AMPLE TIME TO PERMIT REVISIONS BEFORE THE BIDS ARE SUBMITTED, 4. INSTALL MATERIALS AND EQUIPMENT IN A NEAT AND FIRST CLASS WORKMANLIKE MANNER. THE OWNER RESERVES THE RIGHT TO DIRECT REMOVAL AND REPLACEMENT OF ITEMS WHICH, IN HIS OPINION, DO NOT PRESENT A NEAT AND WORKMANLIKE APPEARANCE. REMOVAL AND REPLACEMENT IS TO BE DONE IMMEDIATELY WHEN DIRECTED BY THE OWNER IN WRITING, AT THE SOLE EXPENSE OF CONTRACTOR. 5. START OF WORK BY CONTRACTOR SHALL BE CONSIDERED AS ACCEPTANCE BY HIM OF ALL CLAIMS OR QUESTIONS AS TO SUITABILITY OF THE WORK OF OTHER. TRADES OR OTHER CONTRACTORS TO RECEIVE HIS WORK. THIS CONTRACTOR SHALL REMOVE AND REPLACE, AT HIS EXPENSE, ALL PLUMBING WORK WHICH MAY HAVE TO BE REMOVED BECAUSE OF INTERFERENCE WITH OTHER TRADES. 6. THIS CONTRACTOR SHALL OBTAIN AND PAY ALL INSURANCE, FEES, PERMITS , ASSOCIATION DUES, ROYALTIES AND TAXES OF WHATEVER NATURE SHALL APPLY TO THIS WORK. HE SHALL ALSO PAID ALL THE INSPECTION FEES AS MAY REQUIRED BY LAW OR ORDINANCE AND SHALL KEEP THE OWNER HARMLESS FROM ANY DAMAGE AND EXPENSE ARISING FROM ANY VIOLATION OF LAWS, RULES OR ORDINANCES. 7. PROVIDE MEANS "FURNISH AND INSTALL ". 8. DO A COMPLETE JOB, EVERYTHING CONNECTED, READY FOR USE. 9. SHOP DRAWINGS: CONTRACTOR SHALL FURNISH THE ENGINEER WITH SHOP DRAWINGS OF EQUIPMENT PRIOR TO PURCHASE FOR APPROVAL. 10. AT COMPLETION OF JOB THE PLUMBING CONTRACTOR SHALL GIVE THE OWNER AN AS -BUILT SET OF REPRODUCIBLE SEPIAS SHOWING THE EXACT LOCATION OF ALL INSTALLATIONS. 11. PLUMBING CONTRACTOR SHALL PRESSURE TEST ALL PIPING AS REQUIRED BY CODE. TEST SHALL BE WITNESSED AND APPROVED BY PROPER AUTHORITIES. 12. THE PLUMBING CONTRACTOR SHALL WARRANT ALL WORKMANSHIP AND MATERIALS FOR ONE YEAR FROM THE DATE OF FINAL WORK ACCEPTANCE BY OWNER. ANY BREAKDOWN OCCURRING IN FIRST YEAR SHALL BE REPAIRED AT NO EXPENSE TO THE OWNER. 13. PROVIDE BATHROOM FIXTURES AS SPECIFIED. 14. PROVIDE SHUT -OFF VALVE FOR EACH FIXTURE. 15. WHEREVER NOT SIMILAR METALS ARE TO BE JOINED, A DI- ELECTRIC FITTING SHALL BE PROVIDED TO CONNECT BOTH TYPES OF PIPES. 16. PLUMBING CONTRACTOR SHALL PROVIDE AIR CONDITIONING CONDENSATE DRAIN AND TRAP. SEE AIR CONDITIONING PLANS FOR LOCATION OF UNITS AND DRAINS, 17. MATERIALS A. COLD WATER PIPING DOWNSTREAM OF WATER METER SHALL BE TYPE "L" COPPER BELOW GROUND AND TYPE "M" COPPER ABOVE GROUND B. COLD WATER PIPES INSIDE OF SLAB SHALL BE TYPE "K" SOFT COPPER INSTALL INSIDE POLYETHYLENE CONDUIT. NO JOINTS PERMITTED INSIDE SLAB. C. SANITARY WASTE AND VENT 4 "- AND SMALLER SHALL BE P.V.C., SCHEDULE 40 S. STORM LINES INSIDE BUILDING SHALL BE P.V.C. SCHEDULE 40 E. IN COASTAL AREAS ALL SANITARY AND STORM PIPING OUTSIDE OF BUILDING SHALL BE SCHEDULE 40, PVC. F. CONDENSATE DRAIN PIPE SHALL BE SCHEDULE 40, PVC PIPE AND FITTINGS. G. WATER HEATER RELIEF AND DRAIN LINE SHALL BE TYPE "L" COPPER, MIN 3/4" DIA. FIRE RATED PENETARATION NOTE WHEN FIRE PENETRATION OF PIPING OCCUR, SHALL BE PROTECTED BY ASSEMBLY No. W -L -2088, UL APPRIVED PLUMBING FIXTURE CONNECTION SCHEDULE * SHOWN FOR REFERENCE ONLY, REFER TO ARCHITECT /OWNER FOR LIST OF EXACT FIXTURE TYPE AND MANUFACTURER. ** AS PER FLORIDA PLUMBING CODE TABLE 604.4 No. DESCRIPTION DRAIN WATER SLOPE FU FIXTURE TYPE * MAXIMUM WATER FLOW RATE ** REMARKS COLD HOT WC WATER CLOSET 3" 1/2" N/A 3" &4 " @1 /8 " /FT 3 FLOOR MOUNTED 1.28 GPF P -TRAP L LAVATORY 1 -1/2" 1/2" 1/2" 1- 1/2 " @1 /4 " /FT 1 WALL MOUNTED 1.0 GPM HOT WATER SH SHOWER 2" 1/2" 1/2" 2 " 01 /4 " /FT 2 N/A 1.5 GPM W /ANTI -SCALD VALVES SK SINK 1 -1/2" 1/2" 1/2" 1- 1/2 " @1 /4 " /FT 2 COUNTERTOP 1.0 GPM DW DISHWASHER 1" N/A 1/2" N/A N/A N/A 6.5 GALL /CYCLE INDIRECT WASTE CONNECT TO SINK REF REFRIGERATOR N/A 1/2" N/A N/A N/A N/A N/A ICE MAKER CONNECTION FIELD COORDINATION NOTE: EVERY CONTRACTOR SHALL COORDINATE IN FIELD W/ OTHER TRADES PRIOR TO START OF CONSTRUCTION FOR THE STRUCTURAL BEAM, SLAB,TRUSSES, ARCHITECTURAL DETAILING AS PRE -FAB FORMS, REVELING, CEILINGS, ARCH WITH THE LOCATION OF CEILING OR WALL GRILLES, DUCT WORKS, RETURN GRILLES, LIGHTING FIXTURE, SWITCHES, RECEPTACLES OR ANY OTHER DEVICES, AND TO NOTIFY ARCHITECT /ENGINEER IF ANY CONFLICT OCCUR PRIOR ITS INSTALLATION, NO ADDITIONAL COST TO OWNER CAN BE APPLIED. ON SITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CALCULATION DATA: 3 BEDROOMS, 3,062 SF LIVING AREA LOT AREA--------------------- - - - - -- 12,508 SF MAX DAILY FLOW -------------- - - - - -- 400 GPD ESTIMATED SEWAGE FLOW CALCULATION AS PER 64E -6.008 TABLE / (RESIDENTIAL) FIRST 3300 SF - - - - - - - -------------------- - - - - -- 400 GPD FOR EACH ADDITIONAL 750 SF OR FRACTION ---------- - - - - -- 0 GPD AVERAGE TOTAL DAILY FLOW ------------------------ - - - - -- 400 GPD TOTAL FIXTURE UNITS= 29 29 FU< = >400 GPD SEPTIC SYSTEM AVERAGE DAILY FLOW: (29/29) * 400 GPD= 400 GPD SEPTIC TANK SIZING AS PER AS PER 64E -6.008 TABLE ll TANK : 400 GPD AVERAGE DAILY FLOW -------------- - - - - -- 1,050 GAL. TANK DRAINFIELD SIZING AS PER AS PER 64E -6.008 TABLE III FOR 0.7 GALLONS PER SQUARE FOOT PER DAY DRAINFIELD 400 GPD /0.6= 667 SF THERE ARE NO PERTINENT FEATURES ON THE ADJACENT PROPERTIES AND ACROSS THE STREET THAT MAY AFFECT THE ON SITE SEWAGE TREATMENT AND DISPOSAL SYSTEM INSTALLATION. L_. 500 GAL '� LP GAS 10' MIN —�-� l� LOW PRESSURE 10' MIN REGULATOR 1 I G R U. L, GAS COCK VALVE (TYP.) 0 (3 C_o I, G"inm WN 1 & k SEE SHEET P- FnR MNT11\IIIA NEW 1 "4 CWP S EXISTING CITY WATER �FRVIr.F PIPF -PROPERTY EIRE 118.00 0 �'f f 1 r+ Al L,�aT G r -�' 1,II +i0� l� %�£:!! C.a S.W. 82nd e° f1r:ir4fk8 ^1 1 ~i STREET PLUMBING SITE PLAN SCALE 1/8"= V-0" n Y PLUMBING SYMBOL LEGEND SYMBOL DESCRIPTION - - - - -- EXISTING SANITARY LINE -- EXISTING WATER LINE EXISTING HOT WATER LINE SANITARY LINE - - - - - -- WATER LINE HOT WATER LINE -- -II CO CLEANOUT -- 0 WATER CLOSET DRAIN Z P -TRAP - ICI o DISHWASHER DRAIN VTR VENT THRU ROOF FU FIXTURE UNIT CW COLD WATER HW HOT WATER -- -D� - -- GATE VALVE U ap � m p N IA O NL zrry 02e= i C �a of oza3 V m n0 OJ= Vj ono W Z X3 � W 3 IL W W — w M W W ir�itl 3 ao a m c ''I AJ ,3 istr` v i; !L WILLIAMS GARCIA, PE_ LICENSE PE60082 EC13002719 OFRT. AUTHORIZATION - 26528 Date: 09/21/11 Revisions: 1� HEALTH DEPARTMENT 12/28/11 PLUMBING SITE PLAN P -1 Sheet 1 of 3 a 0 0 u.. � Z UJ 0 = Z 0 co W Q Z a w CO 0 W C QO cri 0 L 0 0 .. Q_ CIL L_ 0 U (n a 0 Date: 09/21/11 Revisions: 1� HEALTH DEPARTMENT 12/28/11 PLUMBING SITE PLAN P -1 Sheet 1 of 3