11-1075-012A/C UNIT SCHECDUL E DESIGNATION DESIGNATION AHU -1 AHU -2 ~ MANUFACTURER RHEEM RHEEM TI TU S MODEL NO. RHLL HM3821 JA RHLL- HM3821 JA MODEL AND TOTAL AIR (CFM) - 975 975 z E.S.P. IN OF W.G. 0.4 0.4 o H.P (F.L.A.) 1/4-2.5 1 4 -2.5 z AVAILABLE SERVICE 240/l/60 240/1/60 = TOTAL COOLING CAPACITY BTU H * 29,600 29,600 (CEILING /WALL) SENSIBLE COOLING CAPAC. - BTU H (* 20,400 20,400 FUNCTION TOTAL HEATING — BTU H ` 24,574 24,574 RETURN ELECTRIC HEATER TOTAL KW 7,200 7,200 SEE DRAWINGS DESIGNATION CU -1 CU -2 OPPOSED BLADE DAMPERS MANUFACTURER RHEMM RHEMM SEE NOTE 4 MODEL N0. 14AJM -30AOI 14AJM 30A01 zz AVAILABLE SERVICE 240 -1 -60 240 -1 -60 FOR APPROVAL. NUMBER OF COMPRESSORS 1 1 ca COMPRESSORS RLA EACH 12.8 12.8 z U5 FAN H.P. FLA EACH 1.4 1.4 S.E.E.R. W MATCHED AHU 16.0 16.0 LL' CONDENSING UNIT MCA AMPS 18 18 CONDENSING UNIT MAX. FUSE OR CKT. BREAKER AMPS 30 30 REMARKS: 1. ALTERNATE MANUFACTURERS OF EQUAL QUALITY MAY BE SUBMITTED FOR APPROVAL (RHEEM, RUUD, LENNOX OR YORK) 2.PROVIDE TIME GUARD II; START CAPACITOR AND RELAY, LIQUID LINE FILTER DRYER & SOLENOID VALVE, 24 V CONTROL TRANSFORMER & . THERMOSTAT WITH SYSTEM "OFF—HEAT—AUTO—COOL," AND FAN "ON- AUTO" S/S AIR LDISTRIB UTION S C HEL7ULE DESIGNATION YES A AREA SERVED -B T MANUFACTURER TI TU S MANUFACTURER TI TU S - TI TU S MODEL AND 250AA TOTAL AIR (CFM 4FL 4FL CATALOG N0. ALL ALUM. SONES ALL ALUM. ALL ALUM, FRAME TYPE SURFACE VOLT—PH—HZ SURFACE SURFACE DRIVE (CEILING /WALL) BACKDRAFT DAMPER (CEILING /WALL) (CEILING /WALL) FUNCTION SUPPLY REMARKS: 1. ALTERNATE MANUFACTURERS OF EQUAL OR BETTER QUALITY MAY BE SUBMITTED FOR APPROVAL. 2. UNLESS OTHERWISE NOTED ALL FANS SHALL BE EQU IP PED WITH SAFETY t E DISCONNECT T C SWITCH. RETURN TRANSFER PATTERN SEE DRAWINGS SEE DRAWINGS SEE DRAWINGS - OPPOSED BLADE DAMPERS -SEE NOTE 4 SEE NOTE 4 SEE NOTE 4 REMARKS: 1. ALTERNATE MANUFACTURERS OF EQUAL' QUALITY MAY BE SUBMITTED FOR APPROVAL. 2. ALL AIR DEVICES SHALL BE ALL ALUMINUM CONSTRUCTION AND FULLY GASKETTED. 3. ALL AIR DEVICES FINISHES SHALL BE PER ARCHITEC /OWNER REQUIREMENTS. 4. SUPPLY OUTLETS SHALL BE SUPPLIED WITH INTEGRAL O.B.D. FAN SCHEL.7ULE FAN DESIGNATION YES EE -1 AREA SERVED TOILET LOCATION CEILING MANUFACTURER BROAN MODEL N0, S50U TOTAL AIR (CFM 50 E.S.P. INCHES OF WATER 0.125 SONES 0.5 H.P. _T =AMP — W =WATTS 0.15 VOLT—PH—HZ 120-1-60 DRIVE DIRECT BACKDRAFT DAMPER YES INTERLOCK LIGHT SWITCH REMARKS: 1. ALTERNATE MANUFACTURERS OF EQUAL OR BETTER QUALITY MAY BE SUBMITTED FOR APPROVAL. 2. UNLESS OTHERWISE NOTED ALL FANS SHALL BE EQU IP PED WITH SAFETY t E DISCONNECT T C SWITCH. E)ESION REQUIREMENTS HVAC DESIGN REQUIRES, YES NO DUCT SMOKE DETECTOR X FIRE DAMPERS X SMOKE DAMPER (S) X FIRE` RATED' ENCLOSURE X FIRE RATED ROOF FLOOR CEILING ASSEMBLY X FIRE STOPPING X SMOKE CONTROL X •t U tia I GREAT ROOM 10x6 125CF M 1ox6 I 12SC u FM �, STUDY 4 0 6�.r UC �11'" c 00 60 MASTER BEDROOM 5.3 �r�.. 1 _ XS 12X8 12X8 4 0 E A 10 125CFM ILSCFM 125CFM WILLIAMS GARCIA, PE_ WALL CAP LICENSE PE60082 EC13002719 — — — - -- - \ 110X6 _ CERT. AUTHORIZATION - 2fib2R. .. 6 — -- 6� -- 1 zSCF 6� 6� _ _ _ - RECESSF_ -D DRYER - I I —.: - - - -- - - - - -- 1 VENT UNIT , 10X8 72X1 ?_ -- -I -� - W D I -- -I- -, 16X16 ;\ Q - 3 i <fl 0x8 ®I x f -- FULLY LOUVERED 10X6 I DOOR UC 8 LAUNDRY 6 125CFM: _ v / I ROOM KITCHEN ', — 40 I OX6 - - - - - -- �- i W.I.C. uc UC 1C70CF12 a 6X4 `❑ -� �- - F- . r 50CEM I I , ., � �' _ I � I �.� x N 9 6x4 �, MASTER 0 - 120 ,, �, — __� I , , I 50CFM � - r \ 6� ti BATH 1 - -- �_— 1 U M1111NIUN GMU - -__ -:, E 50CFM BATH o Cc l J 12X12 r l 4� _ = Flo J _ (26 GA) FOR E111 „� 0 KITCHEN EXHAUST IOX6 / - N��,F — - \ 6X6 —� 12X1? TO ROOF CAP 125CFM 10X6 1 40 ` 40 CFM LL - —._- 6. I m j I IOOCFM \, AH _ i I - 1 U i i I - ------ _' - EF 1 - W C y ------ - - - - -- -- - -- n` o ❑ F - \. PT 16x6 16x6 ULLY LOUVERED 6� _ - I I � W 10X6 10X6 60 DOOR 0 r 125CFIv1 125CF1 f� x 60 60 40 2 r0, , \ 6b - W CIS I I 6X4 _ten EF� 42 Sheet 2 of 2