12-1075-001POOL GENERAL NOTES A) -Ali reinforce steel to conform to A.S.T.M. A615 grade 60 and all floor 8 walls of pod to be pneumatically applied concrete with a min. 28 day compressive strength of 4000 p.s.l. B) -All piping, materials and equipments used In the plumbing system of swimming pods shall conform to the Florida Building Code 2010 edition 'Plumbing" and Florida Building Code 2010 edition "Residential", Chapter 41 installed in accordance with the manufacturer's Installation standards. C) - "Caution" prior to excavation the contractor is responsible for contacting the necessary personnel for locating any and all utilities that may exist. Call Sunshine State One Call prior to digging for verification of locations. D) -The pool contractor responsibility to protect existing structures from failure by sheathing and/or shoring, or other methods as required. The design engineer takes no responsibility for the safety of existing structures. E) -The design engineer takes no responsibility for pool construction in easements, reservations areas or required setback areas. Pod contractor and/or owner shall verify all shown dimensions in the field and establish lot lines prior to construction. F) -The contractor shall verify all quantities and details shown on the drawings from the engineer and shall notify of all omissions, errors, conflicts and discrepancies found therein, failure to discover or to correct errors, conflicts or discrepancies shall no relieve the Contractor full responsibility for unsatisfactory work, faulty construction or improper operation resulting there from, nor from rectifying such condition at his own expense. G) - At the site contractor must verify existing utility locations, off- sets and elevations (soft -dig) prior to star construction, minimum clearance dimensions shall be held and shall be as required by the local regulatory agency. "Caution" Hold a distance of 10 feet minimum from overhead electric lines to poors water edge. H) -The contractor bears full responsibility for all maintenance of private property and safety of the public as relates to his work. 1) -Ali pool screened enclosures and fences shall Conform to the barrier requirements of Florida Building Code 2010 edition "Residential ". Chapter 41, Section R4101.17 and Florida Building Code 2010 edition "Building", Chapter 4, Section 424.2.17 for residential (private) swimming pools or with the barrier requirements of Section 8C-4 of Chapter 8C of the Miami Dade County code. Safety Pool covers shall conform to the requirements of NSPVASTM F 1346. J) -Where pods abut or are placed nearby sea wall or bulkheads, special care shall be employed. The walls shalt be In good condition, not permitting any shifting or removal, or loosening of the supporting soil away from the pod. If the walls do not fully contain the soils behind them, they shall be replaced or repaired. Continual maintenance of the walls is required by the property owner. When excavating for the pod, the sea -wall tiebacks shall not be exit K) -The contractor shall backfill pod shell with caution. The plumbing shall not be disturbed. Backfill shall be performed with clean sand, free of organic materials and shall be placed in 12 Inch thick layers. Each layer shall be compacted to 90% of the soils maximum density by tampering solidly. Soils below the deck shall be placed In similar manner. Where decks are indicated by others, the deck design notes shown on the typical section do not apply. Deck design shall be by others. Do not drain pod under high ground water or storm conditions. L) -Do not empty pool after construction for repairs or any other reason before consulting with a pod design company or pool repair contractor. Hydrostatic uplift pressures must be eliminated to prevent pod from floating above ground, and causing damage to the structural integrity of the pod. M) - Filter backwash shall comply with the Florida Building Code 2010 edition, "Residential ", Chapter 41, and Section R4101.20 "Filters" and Florida Building Code 2010 edition, "Building% Chapter 4, Section 424.1.6.5.5. "Filters" N) -Pod Waste Water Disposal shall comply with Florida Building Code 2010 edition, "Building", Chapter 4, Section 424.2. 10 "Waste Water Disposal ". 0) -The gas piping system will be design by the gas company serving In the area of this project and shalt be comply with the Florida Building Code 2010 edition "Fuel Gas" in accordance with the manufactures recommendations. P) - Electrical Wiring and equipment shalt comply with the Florida Building Code 2010 edition, Chapter 27 "Electrical" Q) - Install wiring and devices as Indicated in pool data shall furnished electrical service at existing entry. Install disconnect switch at motor if not within 50' of fused switch at service point. Electrical right connection to Comply with nec 660 -1575 art 680. Most up-to -date edition or revision... All metallic conduits, piping system, reinforcing steel, righting fixtures and fixture housing, metal parts of ladders, and their supports, shall be bounded together and grounded to a Common ground. Bounding conductors shall not be smaller than #8 copper. No overhead open wire over pod water. Receptacles to be located minimum 10' of edge of water. R) -Poor right to be grounded to common bonding grid Consisting of (1) #8 continuous copper wire looped around pod perimeter. Loop shall be grounded to panel via pod wall steel, deck reinforcing, and pump motor casing. S) - Temperature of spa water shall be set so that maximum water temperature does not exceed 102 degrees Fahrenheit T) -For design purposes has been utilized a bearing value of 2000 psf typical of a soil with combination of undisturbed sand and limerock. A letter will be submitted after the pool has been excavated attesting that the soil conditions are similar or better to the used In the design. U) -All treads shall have slip- resisting surfaces per ANSI. 6.1.5 V) - - Swimouts shall comply with the Florida Building Code 2010 edition, "Reside ntial% Chapter4l, Section R4101.18 and with Florida Building Code 2010 edition, "Building% Chapter4, Section 424.125.4. "Swimouts" W) -This pool has been designed to all applicable requirements of the Florida Building Code 2010 edition, 'Residential, Chapter 41 and Florida Building Code 2010 edition, "Building", Chapter 4, Section 424 STATEMENT OF THE ENGINEER -This plan remains the property of the design engineers. It is not transferable from one Contractor to another without the written permission of the design engineers. his plan was prepared under my direction and to the best of my knowledge and belief Complies with the intent of "The Florida Building Code, latest version and revisions In Conjunction with the cities minimum standards-requirements -Not valid without embossed seal. -We have used the latest information available to show all existing utilities, however the engineer takes no responsibility for any inaccuracies In the locations shown. POOL: SPA : Pool Size (FT): EXIST. Spa Size (FT):NE RRf 8' X8' Deep End (FT): EXIST. Spa Area(SF): 58 SF Shallow End (FT):EXIST. Spa Perimeter(LF): 28 LF Pool Area(SF): EXIST. Spa Volume (GAL): 870 GAL Pool Perimeter(LF): EXIST. Turnover Rate(HR): 0.15 HR Pool Volume (GAL): EXIST. Spa Pump Size (HP)2 HP Turnover Rate(HR): EXIST. Filter System & Size :200 SF CARTRIDGE Interior Finish: NEW DIAMOND BRiTE Spa Raised: 18" Waterline Tile: EXIST. Jets: 10 Coping: EXIST. Overflow: NONE Pump Size (HP )EXIST. Maindrains: 2 Filter System & Size: EXIST, Automatic Surface Skimmer:ONE Inlets: EXIST. Underwater Safety Light: 100 W, 12 V Maindrains: EXiST. Spa Miscellaneous Items: 2" Vacuum Line w/ Safety LockEXIST. 1 SALT SYSTEM Automatic Surface Skimmer:EX{ST. • Underwater Safety Light: EXiST. 2. 400,000 BTU GAS HEATER BY OWNER Deck Finish & Size: EXIST. 0 ® Deck Drains (LF): EXIST. 0 Pool Miscellaneous Items: 1. (n w 2. SAFETY BARRIER REQUIREMENTS : ALL DOORS AND WINDOWS WITH DIRECT ACCESS TO THE POOL THROUGH THAT WALL SHALL BE EQUIPPED WITH AN ALARM WHICH PRODUCES AN AUDIBLE WARNING WHEN THE DOOR AND ITS SCREEN ARE OPENED. THE ALARM SHALL SOUND CONTINUOUSLY FOR A MINIMUM OF 30 SECONDS IMMEDIATELY AFTER THE DOOR IS OPENED AND BE CAPABLE OF BEING HEARD THROUGHOUT THE HOUSE DURING NORMAL HOUSEHOLD ACTIVITIES. THE ALARM SHALL AUTOMATICALLY RESET UNDER ALL CONDITIONS. THE ALARM SHALL BE EQUIPPED WITH A MANUAL MEANS TO TEMPORALITY DEACTIVATE THE ALARM FOR A SINGLE OPENING. SUCH DEACTIVATION SHALL LAST NO MORE THE 15 SECONDS. THE DEACTIVATION SWITCH SHALL BE LOCATED AT LEAST 54 INCHES ABOVE THE THRESHOLD OF THE DOOR. THE SAFETY BARRIER SHALL CONFORM TO THE BARRIER REQUIREMENTS OF FLORIDA BUILDING CODE 2010 EDITION "RESIDENTIAL ", CHAPTER 41, SECTION R4101.17 AND FLORIDA BUILDING CODE 2010 EDITION "BUILDING ", CHAPTER 4, SECTION SOiL STATEMENT IN ORDER TO CONSTRUCT THE SWIMMING POOL IN QUESTION, AND AFTER INSPECTING THE GROUND SURFACE, i OBSERVED A SILTY AND CLAYEY GRAVEL TYPE OF SOIL WITH A DESIGN - BEARING CAPACITY OF 2000 PSF. AFTER GROUND HAS BEEN BROKEN I WILL CONFIRM THAT THIS IS THE CASE THROUGH THE SUBMITTAL OF ANOTHER LETTER SHOULD THE INSPECTOR REQUEST IT. SUCH LETTER WILL ATTEST THAT SOIL CONDITIONS ARE SIMILAR TO THE ONES DESCRIBED IN TABLE 1804.2 OF THE FLORIDA BUILDING CODE: BUILDING CHAPTER, BASICALLY THIS IS A SOIL PRESENTING MATERIALS SUCH AS SAND, SILTY SAND, CLAYEY SAND, SILTY GRAVEL AND CLAYEY GRAVEL EXIST. POOL EQUIP. NEW SPA EQUIP. PAD ELECTRIC METER EXIST. 4' C.LFENCE W2 }" MESH SIZE SELF CLOSING & LATCHING GATE W /LOCKING DEVICE 54" ABOVE FINISH e'o1 Ati bwPh/ 30' -10" I 34' -10" 11 w1 w kn I w I i GRADE ELEVATION—,--I I� I UNDERGROUND POWER SERVICE L_ I r, 7 CO t - N Co EXIST. 6' C.LFENCE $$ p7. 10" 1' -6" ff UnCt 38' -11 "^" aterl[na— " p_.. 6 "X12" CHISELED ON 4" I _ CONC. SLAB WITH 6x6 10/10 W.W. M 0: E 15 0 SWIMMING �? '.._.CDNTRASTING_TdtE._.___ I. POOL I I O xE IST, i I a $ x $ CONC. POOL DECK IDRAINFIELD) MAIN DRAIN x,rr W/1 # 50 CONT. L�__J #3 @ 10" SANITARY /SEPTIC EACH WAY N EXIST. TANK EACH FACE ONE C.B.S STORY o RESIDENCE PL. a F.F.ELEV =10.5 200 A ® HOUSE PANEL PUMP SPA SECTION SCALE: 1/2"=11'—O', EXIST. 6' WOOD FENCE PL EXIST. W /SELF CLOSING &SELF DRIVEWAY LATCHING GATE EXIST. W /LOCKING DEVICE CONC. ` 54" ABOVE FINISH CONC. PL GRADE ELEVATION. THE HORIZONTAL MEMBERS LOCATED ON EXIST. r THE POOL SIDE AND THE � DRIVEWAY � I SPACING BETWEEN + _ \\7 VERTICAL MEMBERS SHALL 10' UTILITY fL NOT EXCEED 1 3/4" IN ® EASEMENT WIDTH. COMPLY WITH F.B.C. CHARTER 84101.17 110.00' WATER 15' PARKWAY ® SW 64th AVENUE SITE PLAN 1 " = 20' -0 LEGAL DESCRIPTION : LOT 9, BLOCK 1 OF "W.A. DANIELS SUBDIVISION ACCORDING TO THE PLAT THEREOF, AS RECORDED IN PLAT BOOK 102, PAGE 76 OF THE PUBLIC RECORDS OF MIAMI —DADE COUNTY, FLORIDA. 100% LOT COVERAGE = 13,750 S.F LANDSCAPE COVERAGE (MIN) = 60 % LOT COVERAGE = 8,250 S.F ACTUAL LANDSCAPE COVERAGE _ 8,250 S.F = 60 % BUILDING AND POOL COVERAGE (MAX.) _ 40% LOT COVERAGE = 5,500 S.F ACTUAL BUILDING, POOL COVERAGE= HOUSE --- - - - - -- -2718 S.F =19.7 % POOL /SPA/DRiVEWAY -2782 S.F =20.2 5,500 S.F =40.0 METER k ...__.___ ....._ __ . _..__........ _. _..___..._...__.., _.. _.____.._.._. ...._.__ _.__..... __.___._ _.____._ <__._._..__.__.__ . ._� _._. 4' -0" 8' -0" 4'-0" I: 1' -0" 6' -0 1 0" / O �^ _ ELEV =11.5' _I " NEW SPA NEW DECK 14 -6 / 240 AREA / Q O ......SQ IN ELEV =10.0' Q I to t N 1 n SPA CONTROL FREESTANDING G.F.C.I. OUTLET SHALL BE LOCATED NOT CLOSER THAN 10 ORE THANE 20N0 EET l f EXISTING EXIST. FROM _ WATER'S EDGE. RESIDENCE POOL EQUIP. NEW SPA EQUIP. 1! -9. MIE Amtr�� 1 ECK tt 7tc r w - P___4 at.� - 1 NEW DECK �- AREA ALL DOORS AND WINDOWS PROVIDING DIRECT ACCESS FROM THE HOME TO THE POOL SHALL BE EQUIPPED WITH AN EXIT ALARM COMPLYING WITH UL -2017 THAT HAS A MINIMUM SOUND PRESSURE RATING OF 85 DB A AT 10 FEET — FBC R4101.17.1.9.1. - -- - - -- POOL LAYOUT PLAN 1,Z4 =1 —0 0 N O � a � o>a w 0 E 0 w E all W PROL POOL,iNCQ COPYRIGHT 7HS DRAINING IS THE PROPERTY OF PROL POOL,INC uNLESS O PROVIDED FOR BY CONTRACT. THE CONTENTS OF IRS DRAWING ARE COWIDENTIAL AND S?iALL NOT BE TRANSMITTED TO ANY PARTY EXCEPT AS AUTHORIZED To BY THE ENGINEERS OF RECORD. o Y � m W Z 0 X Ld W 0 t� a ,n, L0 r `n J Q Cr) U. V) 0 "` < < < z O CJ 0 ® < 0 cn (n w 0 < °a < 10 0 H Ind � w Rn oC4 � W w vn Q cr4N L W) Q `0 L251 E5 cr wL a a 0 project number: sheer title SWIMMING POOL SITE PLAN AND DETAILS r e v i s i o n s issued for: Issue date: 10 -1 -12 drawn bp: approve Scale: AS INDICATE4" a A) , ' t . a EMILIANO OR - ;•••°'PEE. Florida Registration `W4i' 817 SW 122 AVE. MIAMi FL, 33184 (786) 715 7125 s e e t number S P - I sheet: 1 of 2