11-468-008-, V 1 V 1\ 11 1 W.I VV 1.
OF VENT AND DRAIN
WASHING MACHINE SUPPLY & DRAIN PIPING DIAGRAM
AITQ
TYP. PLUMBING FIXTURES PIPING CONNECTIONS
QUANT
FIXTURE
C.W.
H.W.
WASTE
F.UNITS
F.UNITS
TOTAL
2
SHOWER
1/2
1/2
2"
2
4
3
TOILET
1/2
UNION
3"
4
4
4
LAVATORY
1/2
1/2
1 1/2"
1
4
1
WASHER
1/2
1/2
3"
4
4
1
JACUZZI
1/2
1/2
2"
2
2
1
SINK
1/2
1/2
2"
2
2
TOTAL
20
GENERAL PLUMBING NOTES AND SPECIFICATIONS
1. A. SCOPE OF WORK:
THE WORK SHALL INCLUDE ALL PLUMBING NECESSARY ON THE DRAWING
SPECIFIED HERE IN AND /OR AS NEEDED FOR A COMPLETE SYSTEM.
INCLUDING BUT NOT NECESSARILY LIMITED TO:
1. DOMESTIC COLD AND HOT WATER PIPING SYSTEMS
2. SANITARY DRAIN AND VENT SYSTEM (N /A)
3. PLUMBING FIXTURES AND TRIM
4. AIR CONDITIONING CONDENSE DRAINS
5. PRESSURE AND TEMPERATURE RELIEF FROM WATER HEATER
6. PIPING INSULATION
7. SUPPORTS AND HANGERS
B. ALL PLUMBING WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE
LATEST EDITION OF THE FLORIDA BUILDING CODE, PLUMBLING. LOCAL
ORDINANCES AND IN COMPLIANCE WITH THE FLORIDA ENERGY EFFICIENCY
CODE FOR BUILDING CONSTRUCTION AND HRS. REGULATIONS IN THE EVENT
OF CONFLICT BETWEEN ANY CODE OR REGULATIONS. THE MORE STRINGENT
REQUIREMENTS WILL GOVERN.
2. CONTRACTOR TO VERIFY AT SITE THE LOCATION ELEVATION AND SIZE OF
ALL EXISTING LINES FOR CONNECTION BEFORE INSTALLATION OF ANY PIPING.
3. UNDERGROUND METAL PIPING SHALL BE PROTECTED WITH A COAT OF
BITUMINOUS COMPOUND BEFORE COVERING, BITUMASTIC OR EQUAL.
4. ALL FIXTURES SHALL BE PROTECTED AGAINST WATER HAMMER WITH AIR
CHAMBERS OR SHOCK ABSORBERS AS INDICATED ON PLANS.
5. ALL FLOOR DRAINS TO HAVE TRAP PRIMERS %" LINE FROM THE NEAREST
PLUMBING FIXTURE.
6. PLUMBING FIXTURES SHALL BE CONSTRUCTED WITH APPROVED MATERIALS
SHALL HAVE SMOOTH IMPERVIOUS SURFACES AND SHALL BE FREE FROM
DEFECTS AND CONCEALED FOULING SURFACES. ALL FIXTURE TRIM TO BE
CHROME PLATED. FIXTURES SHALL BE PROVIDE WITH SUPPORTS, HANGERS,
ETC.
7. WASTE LINES TO SLOPE 1/8 FT. UNLESS OTHERWISE NOTED.
8. VENT LINES TO EXTEND 9" MIN. ABOVE ROOF AND FLASH WITH LEAD.
9. WATER PIPE BELLOW GROUND SHALL BE COPPER TYPE. ABOVE GROUND
TO BE COPPER TYPE.
10. PIPING INSULATION:
A. SUPPORT ALL PIPE FROM SOUND PORTIONS OF STRUCTURE AND AT
PROPER INTERVALS ACCORDING WITH CODE.
B. PROVIDE SLEEVES FOR ALL PIPING PASSING THROUGH FOUNDATION.
SLABS OR MASONRY WALLS. CAULKS OPENINGS BETWEEN PIPE AND
SLEEVES.
C. WHERE EXPOSED PIPES PASS THROUGH FLOORS, WALLS, OR CEILINGS
PROVIDE ESCUTCHEONS FIRMLY SECURED TO THE PIPES AND OF SUFFICIENT
OUTSIDE DIAMETER TO COVER THE SLEEVED OPENING FOR THE PIPES.
PROVIDE CHROMIUM PLATED ESCUTCHEONS ON BATHROOM.
11. INSPECTIONS AND TESTS
A. CONTRACTORS SHALL BE RESPONSIBLE TO ASK FOR INSPECTIONS TO THE
AUTHORITIES HAVING JURISDICTION. AS THE WORK PROGRESS ALL SYSTEM
SHALL BE TESTED BY CODE AND / OR LOCAL REGULATIONS.
B. DRAINAGE PIPING BEFORE INSTALLATION OF ANY DRAINS. THE END OF
SYSTEMS SHALL BE CAPPED AND ALL LINES FILLED WITH WATER TO
HIGHEST POINT AND ALLOWED TO STAND UNTIL INSPECTIONS IS MADE BY
AN OWNER REPRESENTATIVE.
12. STERILIZE ALL WATER LINES WITH A MIXTURE OF 2 POUNDS OF
CHLORINATED LIMED TO 1000 GALLONS OF WATER (50PPM OF AVAILABLE
CHORINE). RETAIN MIXTURES IN PIPES 24 HOURS AND FLOSS THOROUGHLY
WITH POTABLE WATER BEFORE PLACING IN SERVICE.
13.SHOWER COMPARTMENTS SHALL HAVE FLOORS AND WALLS CONSTRUCTED
OF SMOOTH, CORROSION RESISTANT AND NONABSORBENT WATER— RESISTANT
MATERIALS TO A HEIGHT OF NOT LESS THAN 70 INCHES ABOVE THE
COMPARTMENT FLOOR AT THE DRAIN.
NOTE:
ALL COLD AND HOT WATER OUTLETS ARE
IN 1/2- 0 PIPE EXCEPT AS INDICATED ON PLANS.
FINISHED W
OR COLUMI`
ANCHOR LI
EMBEDDED
IN CONC.
ACCESS
DOOR
(TEE C.O. W/ BRONZE
COUNTER SUNK PLUG
SECTION
TEE CLEAN OU T`.
N.T.S.
MAY EXTEND AS A
Al WASTE OR VENT
CHROME WALLCOVER
AND SCREW.
PLUGGED TEE W/
CLEAN OUT
WALL (PER PLANS)
FLOOR (PER PLANS)
1/8" C.I. BEND
NOTE:
BALANCE OF PIPING SAME AS
CLEAN OUT TO GRADE.
WALL CLEAN OUT DETAIL
N.T.S.
16" SQUARE CONC.
PAD TROWEL
SMOOTH AND EDGE.
WASTE LINE -
REFER TO CIVIL
DRAWINGS.
- BRASS CLEAN OUT PLUG
W/ COUNTER SUNK
HEAD. FLUSH WITH
FINISHED GRADE
1/8 C.I. BEND
C.I. WASTE LINE
LENGTH TO SUIT.
118 BEND IF
CLEAN OUT OCCURS
AT END OF LINE.
FLOOR CLEAN OUT INSTALLATION
N.T.S.
TEMPERATURE AND
PRES. RELIEF VALVE
3/4" THICK (MIN.)
ARRESTER
SPECS.
PIPE TO OUTSIDE OF
F.U. RATING
CATALOG NO.
BUILDING & DISCHARGE
STANDARDS
A
6" ABOVE GRADE
7
5005
J. R. SMITH
ASSE 1010
Q
SHUT -OFF
p
W
VALVE
UNION
N cu
Uz
HEAT TRAP PER
"o@
A
ENERGY CODE -�
o`oo
UNION
. rn
�Qr-
M
ELECTRICAL
ry O
W N
O
N
o
-�
Z
JUNCTION BOX
Z
D-
ELECT.
HOT WATER
'a
CONN.
SUPPLY LINE
i
•E
EMBLEM AND
RATING PLATE
ELECTRICAL
ACCESS PANELS
WATER HEATER
PAN (OMIT ON
GROUND FLR.)
DRAIN VALVE
HOSE
CONNECTION
PAN DRAIN
PARALLEL TO�_Z
P &T RELIEF
HOT WATER HEATER DETAIL N.T.S.
i
ACCESS
DOOR
ELECTRICAL CKTS AND DEVICES
MECHANICAL INSTALLATIONS
PLUMBING INSTALLATIONS
I
WATER HAMMER
ARRESTER
SPECS.
P.D.I. UNITS
F.U. RATING
CATALOG NO.
MANUFACTURER
STANDARDS
A
1 — 11
5005
J. R. SMITH
ASSE 1010
LEGEND:
SANITARY LINE BLW. SLAB
COOL WATER
HOT WATER
EXISTING SAN PIPE
PLUMBING NOTES:
1. WC = 1.28 GALLON PER FLUSH
2. ALL SANITARY LINES SHALL BE SLOPED AS FOLLOWS:
- 2" OR SMALLER SHALL BE SLOPED AT 1/4" PER FT.
- 3" OR LARGER SHALL BE SLOPED AT 1/8" PER FT.
3. PROVIDE ANTI SCALD VALVES AT ALL SHOWERS.
4. PROVIDE 12" HIGH WATER HAMMER ARRESTING
CHAMBER AT EACH FIXTURE GROUP.
5. PROVIDE GATE CONTROL VALVE @ EACH FIXTURE, HOSE
BIB EVEN IF NOT INDICATED ON RISER OR ISOMETRIC. NO
EXCEPTIONS (TYPICAL)
N0 - DATE
Z
O
_
W
J
W
W
Z
o
Lo
N
Lo
V
Z
M
M
~
U') O
Ja
_j
U-
L0
r
O U
W
Q
^N
p
W
00
N cu
Uz
"o@
A
O >
o`oo
W
. rn
�Qr-
M
m
ry O
W N
O
N
o
-�
Z
m o
2 o
Z
D-
'a
Z _
Cj
O
•E
W 00
W
u- a)
Z
O
_
W
J
W
W
Z
o
Lo
DATE
04 -15 -2011
Lo
V
Z
M
M
g
Ja
_j
U-
Q C-0
Q
W C/'
�
Z co
ZLo
�
0
cn
DRAWING NO.
p=1
(SHEET OF 2
t�
t c
4
tiZrQ,.
1
a � �•
>t
Y
W
DATE
04 -15 -2011
SCALE
AS SHOWN
DESIGNED
E. 0.
DRAWN
AG
SEAL
DRAWING NO.
p=1
(SHEET OF 2
t�
t c
4
tiZrQ,.
1
a � �•
>t
Y
W
DATE
04 -15 -2011
SCALE
AS SHOWN
DESIGNED
E. 0.
DRAWN
AG
DRAWING NO.
p=1
(SHEET OF 2
t�
t c
4
tiZrQ,.
1
a � �•
>t