11-468-008-, V 1 V 1\ 11 1 W.I VV 1. OF VENT AND DRAIN WASHING MACHINE SUPPLY & DRAIN PIPING DIAGRAM AITQ TYP. PLUMBING FIXTURES PIPING CONNECTIONS QUANT FIXTURE C.W. H.W. WASTE F.UNITS F.UNITS TOTAL 2 SHOWER 1/2 1/2 2" 2 4 3 TOILET 1/2 UNION 3" 4 4 4 LAVATORY 1/2 1/2 1 1/2" 1 4 1 WASHER 1/2 1/2 3" 4 4 1 JACUZZI 1/2 1/2 2" 2 2 1 SINK 1/2 1/2 2" 2 2 TOTAL 20 GENERAL PLUMBING NOTES AND SPECIFICATIONS 1. A. SCOPE OF WORK: THE WORK SHALL INCLUDE ALL PLUMBING NECESSARY ON THE DRAWING SPECIFIED HERE IN AND /OR AS NEEDED FOR A COMPLETE SYSTEM. INCLUDING BUT NOT NECESSARILY LIMITED TO: 1. DOMESTIC COLD AND HOT WATER PIPING SYSTEMS 2. SANITARY DRAIN AND VENT SYSTEM (N /A) 3. PLUMBING FIXTURES AND TRIM 4. AIR CONDITIONING CONDENSE DRAINS 5. PRESSURE AND TEMPERATURE RELIEF FROM WATER HEATER 6. PIPING INSULATION 7. SUPPORTS AND HANGERS B. ALL PLUMBING WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST EDITION OF THE FLORIDA BUILDING CODE, PLUMBLING. LOCAL ORDINANCES AND IN COMPLIANCE WITH THE FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION AND HRS. REGULATIONS IN THE EVENT OF CONFLICT BETWEEN ANY CODE OR REGULATIONS. THE MORE STRINGENT REQUIREMENTS WILL GOVERN. 2. CONTRACTOR TO VERIFY AT SITE THE LOCATION ELEVATION AND SIZE OF ALL EXISTING LINES FOR CONNECTION BEFORE INSTALLATION OF ANY PIPING. 3. UNDERGROUND METAL PIPING SHALL BE PROTECTED WITH A COAT OF BITUMINOUS COMPOUND BEFORE COVERING, BITUMASTIC OR EQUAL. 4. ALL FIXTURES SHALL BE PROTECTED AGAINST WATER HAMMER WITH AIR CHAMBERS OR SHOCK ABSORBERS AS INDICATED ON PLANS. 5. ALL FLOOR DRAINS TO HAVE TRAP PRIMERS %" LINE FROM THE NEAREST PLUMBING FIXTURE. 6. PLUMBING FIXTURES SHALL BE CONSTRUCTED WITH APPROVED MATERIALS SHALL HAVE SMOOTH IMPERVIOUS SURFACES AND SHALL BE FREE FROM DEFECTS AND CONCEALED FOULING SURFACES. ALL FIXTURE TRIM TO BE CHROME PLATED. FIXTURES SHALL BE PROVIDE WITH SUPPORTS, HANGERS, ETC. 7. WASTE LINES TO SLOPE 1/8 FT. UNLESS OTHERWISE NOTED. 8. VENT LINES TO EXTEND 9" MIN. ABOVE ROOF AND FLASH WITH LEAD. 9. WATER PIPE BELLOW GROUND SHALL BE COPPER TYPE. ABOVE GROUND TO BE COPPER TYPE. 10. PIPING INSULATION: A. SUPPORT ALL PIPE FROM SOUND PORTIONS OF STRUCTURE AND AT PROPER INTERVALS ACCORDING WITH CODE. B. PROVIDE SLEEVES FOR ALL PIPING PASSING THROUGH FOUNDATION. SLABS OR MASONRY WALLS. CAULKS OPENINGS BETWEEN PIPE AND SLEEVES. C. WHERE EXPOSED PIPES PASS THROUGH FLOORS, WALLS, OR CEILINGS PROVIDE ESCUTCHEONS FIRMLY SECURED TO THE PIPES AND OF SUFFICIENT OUTSIDE DIAMETER TO COVER THE SLEEVED OPENING FOR THE PIPES. PROVIDE CHROMIUM PLATED ESCUTCHEONS ON BATHROOM. 11. INSPECTIONS AND TESTS A. CONTRACTORS SHALL BE RESPONSIBLE TO ASK FOR INSPECTIONS TO THE AUTHORITIES HAVING JURISDICTION. AS THE WORK PROGRESS ALL SYSTEM SHALL BE TESTED BY CODE AND / OR LOCAL REGULATIONS. B. DRAINAGE PIPING BEFORE INSTALLATION OF ANY DRAINS. THE END OF SYSTEMS SHALL BE CAPPED AND ALL LINES FILLED WITH WATER TO HIGHEST POINT AND ALLOWED TO STAND UNTIL INSPECTIONS IS MADE BY AN OWNER REPRESENTATIVE. 12. STERILIZE ALL WATER LINES WITH A MIXTURE OF 2 POUNDS OF CHLORINATED LIMED TO 1000 GALLONS OF WATER (50PPM OF AVAILABLE CHORINE). RETAIN MIXTURES IN PIPES 24 HOURS AND FLOSS THOROUGHLY WITH POTABLE WATER BEFORE PLACING IN SERVICE. 13.SHOWER COMPARTMENTS SHALL HAVE FLOORS AND WALLS CONSTRUCTED OF SMOOTH, CORROSION RESISTANT AND NONABSORBENT WATER— RESISTANT MATERIALS TO A HEIGHT OF NOT LESS THAN 70 INCHES ABOVE THE COMPARTMENT FLOOR AT THE DRAIN. NOTE: ALL COLD AND HOT WATER OUTLETS ARE IN 1/2- 0 PIPE EXCEPT AS INDICATED ON PLANS. FINISHED W OR COLUMI` ANCHOR LI EMBEDDED IN CONC. ACCESS DOOR (TEE C.O. W/ BRONZE COUNTER SUNK PLUG SECTION TEE CLEAN OU T`. N.T.S. MAY EXTEND AS A Al WASTE OR VENT CHROME WALLCOVER AND SCREW. PLUGGED TEE W/ CLEAN OUT WALL (PER PLANS) FLOOR (PER PLANS) 1/8" C.I. BEND NOTE: BALANCE OF PIPING SAME AS CLEAN OUT TO GRADE. WALL CLEAN OUT DETAIL N.T.S. 16" SQUARE CONC. PAD TROWEL SMOOTH AND EDGE. WASTE LINE - REFER TO CIVIL DRAWINGS. - BRASS CLEAN OUT PLUG W/ COUNTER SUNK HEAD. FLUSH WITH FINISHED GRADE 1/8 C.I. BEND C.I. WASTE LINE LENGTH TO SUIT. 118 BEND IF CLEAN OUT OCCURS AT END OF LINE. FLOOR CLEAN OUT INSTALLATION N.T.S. TEMPERATURE AND PRES. RELIEF VALVE 3/4" THICK (MIN.) ARRESTER SPECS. PIPE TO OUTSIDE OF F.U. RATING CATALOG NO. BUILDING & DISCHARGE STANDARDS A 6" ABOVE GRADE 7 5005 J. R. SMITH ASSE 1010 Q SHUT -OFF p W VALVE UNION N cu Uz HEAT TRAP PER "o@ A ENERGY CODE -� o`oo UNION . rn �Qr- M ELECTRICAL ry O W N O N o -� Z JUNCTION BOX Z D- ELECT. HOT WATER 'a CONN. SUPPLY LINE i •E EMBLEM AND RATING PLATE ELECTRICAL ACCESS PANELS WATER HEATER PAN (OMIT ON GROUND FLR.) DRAIN VALVE HOSE CONNECTION PAN DRAIN PARALLEL TO�_Z P &T RELIEF HOT WATER HEATER DETAIL N.T.S. i ACCESS DOOR ELECTRICAL CKTS AND DEVICES MECHANICAL INSTALLATIONS PLUMBING INSTALLATIONS I WATER HAMMER ARRESTER SPECS. P.D.I. UNITS F.U. RATING CATALOG NO. MANUFACTURER STANDARDS A 1 — 11 5005 J. R. SMITH ASSE 1010 LEGEND: SANITARY LINE BLW. SLAB COOL WATER HOT WATER EXISTING SAN PIPE PLUMBING NOTES: 1. WC = 1.28 GALLON PER FLUSH 2. ALL SANITARY LINES SHALL BE SLOPED AS FOLLOWS: - 2" OR SMALLER SHALL BE SLOPED AT 1/4" PER FT. - 3" OR LARGER SHALL BE SLOPED AT 1/8" PER FT. 3. PROVIDE ANTI SCALD VALVES AT ALL SHOWERS. 4. PROVIDE 12" HIGH WATER HAMMER ARRESTING CHAMBER AT EACH FIXTURE GROUP. 5. PROVIDE GATE CONTROL VALVE @ EACH FIXTURE, HOSE BIB EVEN IF NOT INDICATED ON RISER OR ISOMETRIC. NO EXCEPTIONS (TYPICAL) N0 - DATE Z O _ W J W W Z o Lo N Lo V Z M M ~ U') O Ja _j U- L0 r O U W Q ^N p W 00 N cu Uz "o@ A O > o`oo W . rn �Qr- M m ry O W N O N o -� Z m o 2 o Z D- 'a Z _ Cj O •E W 00 W u- a) Z O _ W J W W Z o Lo DATE 04 -15 -2011 Lo V Z M M g Ja _j U- Q C-0 Q W C/' � Z co ZLo � 0 cn DRAWING NO. p=1 (SHEET OF 2 t� t c 4 tiZrQ,. 1 a � �• >t Y W DATE 04 -15 -2011 SCALE AS SHOWN DESIGNED E. 0. DRAWN AG SEAL DRAWING NO. p=1 (SHEET OF 2 t� t c 4 tiZrQ,. 1 a � �• >t Y W DATE 04 -15 -2011 SCALE AS SHOWN DESIGNED E. 0. DRAWN AG DRAWING NO. p=1 (SHEET OF 2 t� t c 4 tiZrQ,. 1 a � �• >t