12-910R-008I 0 I , a AIR CONDITIONING SPECIFICATIONS L GENERAL: A. ALL DIMENSIONS AND ACTUAL CONSTRUCTION CONDITIONS MUST BE VERIFIED AT THE PROJECT SITE PRIOR TO SUBMITTING BID. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY ENGINEER OF ANY DISCREPANCIES IMMEDIATELY. B. THESE DRAWINGS ARE DIAGRAMMATIC AND REQUIRE CLOSE COORDINATION WITH EXISTING STRUCTURE, LIGHTS, CONDUITS, PLUMBING AND CEILING SYSTEM. THE CEILING SPACE IS EXTREMELY TIGHT AND WILL REQUIRE CAREFUL ADVANCE PLANING BEFORE DUCT INSTALLATION. THE CONTRACTORS PRICE FOR THIS PROJECT SHALL INCLUDE A SITE VISIT TO FIELD VERIFY, ALL COORDINATION, DUCT TRANSITIONS AND FIELD ROUTING AS REQUIRED FOR A COMPLETE OPERATING AND TESTED SYSTEM. C. SUBMIT MANUFACTURERS DATA AND SHOP DRAWINGS ON ALL EQUIPMENT, MATERIALS AND DUCT SYSTEM LAYOUT FOR REVIEW BY THE ENGINEER PRIOR TO ORDERING, FABRICATION, OR INSTALLATION. PRIOR TO ORDERING ANY EQUIPMENT, IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THAT EQUIPMENT VOLTAGE SPECIFIED IS AVAILABLE. D. ALL MOTORS STARTERS SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR TO BE WIRED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. E. ALL WORK SHALL BE IN STRICT ACCORDANCE WITH THE FOLLOWING CODES: 1. THE FLORIDA BUILDING CODE 2007 2. NFPA -90A AIR CONDITIONING AND VENTILATION 3. SMACNA. LOW VELOCITY DUCT CONSTRUCTION 4. NFPA 101, LIFE SAFETY CODE 2. MATERIALS: A. GALVANIZED STEEL SHEET METAL DUCT WORK INSTALLED IN ACCORDANCE WITH "SMACNA" STANDARDS WITH R -6 FIBERGLASS DUCT WRAP INSULATION. PROVIDE MANUAL VOLUME DAMPERS AT ALL BRANCH TAKE -OFFS. PROVIDE TURNING VANES AT ALL ELBOWS. FLEXIBLE ROUND DUCTS MAY BE USED FOR DIFFUSER DROPS AS SHOWN ON PLANS. SUBMIT SHOP DRAWINGS. B. OUTSIDE AIR AND EXHAUST DUCTS SHALL BE AIR LEAK SEALED GALVANIZED SHEET METAL. OUTSIDE AIR DUCTS SHALL BE INSULATED SAME AS SUPPLY DUCTWORK ABOVE. 3. CONTRACTOR'S WARRANTY: A. CONTRACTOR SHALL PROVIDE A ONE YEAR WARRANTY FOR ALL EQUIPMENT AND SYSTEMS FROM DATE OF FINAL ACCEPTANCE BY THE OWNER, (CERTIFICATE OF OCCUPANCY). HVAC SYMBOL LEGEND: Q) THERMOSTAT DUCT SMOKE DETECTOR ROOF MTD. EXH. FAN ® REMOTE BULB SENSOR DUCT TURN DOWN ® DUCT SMOKE DETECTOR DUCT TURN UP ® TEST, RESET & ANNUNCIATOR ��,� FLEXIBLE DUCT al=:� TRANSITION FX 1E SMOKE CONTROL EXISTING SUPPLY TURNING VANE 1E EXISTING RETURN sp 45' BRANCH DUCT TAKE -OFF R RELOCATED SUPPLY 5V HORIZONTAL FIRE DAMPER 1z_1R RELOCATED RETURN .V.D. MANUAL VOLUME DAMPER ''!` 1 RETURN REGISTER �N NEW SUPPLY �' SUPPLY DIFFUSER FIN NEW RETURN ' RETURN AIR GRILLE — F FIRE DAMPER COMBINATION FlRE /SMOKE DAMPER —► AIR FLOW DIRECTION MOTORIZED DAMPER ® EXHAUST FAN -- VALVE NOTES: GYPSUM WA RETAINING ANGLE 1 1/40 1/4 x1/8' ai GYPSUM FILLER DAMPER ; MANUAL DAMPER W/ LOCKING ADJUSTMENT HANDLE i BRANCH DUCT — ' G COD EXISTING INLINE DIS EXHAUST F 10 /; /�� r EXISTING EXHAUST FAN G� � 5� P. 10 �\ pt x, \ \� EXISTIN �' �X \S�• \r INLINE EASE \ Nv \ 13 -� EXHAUS FAN 7 2 �n '200 . N`�'" __J � 3 / — \ r, •.. \ � . . � L I Lam' ~. .<�.; . .. .............. ... ... .... i .... El 9 I \ as El E j/) L_.) U.L. SIZE LIMITATIONS 0 VERTICAL MOUNT (DUCT OPENING SIZES); MAXIMUM PANEL 60 "x54" MAXIMUM ASSEMBLY: 120 "x114" MINIMUM PANEL 4 "x4" HORIZONTAL MOUNT (DUCT OPENING SIZES): MAXIMUM PANEL 60 "x54" MAXIMUM ASSEMBLY. 102 "44" MINIMUM PANEL 4 "x4' NOTES: 1. UNDERWRITERS LABORATORIES LISTED AND 1 -1/2 HOUR STANDARD 555. CLASS 'A 2. STANDARD CONSTRUCTION 18 GA. GALVINIZED STEEL 3. PROVIDE 1/8" MOUNTING SCREWS ON 6" CENTERS. 4. PROVIDE ACCESS PANELS IN ADJACENT DUCT FOR ACCESS. NAILOR —HART MODEL 0110 TYPE A 1 1/2 HR "DYNAMIC TYPE" VERTICAL MOUNT FUSIBLE LINK TEMPERATURE: 1657 FIRE DAMPER DETAIL: NOT TO SCALE DIRECTION OF AIR FLOW BRANCH TEE TRUNK DUCT DIRECTION OF AIR FLOW 45* BRANCH DUCT CONNECTION TURNING VANES CHANNEL DAMPER BLADE ZSPLITTER DAMPER CONTROL ROD W/ LOCK HANGING HANG ALL DUCT PER SMACNA STANDARDS I CHANNEL i STRAP & SADDLE 'Ely Dllxi7 CORNER ANGLE TURNING VANES HVAC DUCT DETAILS NOT TO SCALE MECHANICAL PLAN PLAN KEY NOTES: OREMOVE ALL SUPPLY & RETURN DUCTWORK FROM SPACE BACK TO AIR HANDLERS. OEXISTING CHILLED WATER AIR HANDLER TO REMAIN. OREMOVE EXISTING KITCHEN HOOD SUPPLY AND EXHAUST FANS AND DUCTWORK FORM SPACE. OREMOVE EXISTING GREASE DUCT FROM SERVICE CORRIDOR AND CAP OFF AT VERTICAL CHASE. PATCH WALL OPENINGS. FIELD VERIFY COORDINATE W/ OWNER EXACT LOCATION OF TERMINATION. OREMOVE EXISTING EXHAUST FAN, DUCT AND LOUVER. PATCH WALL OPENINGS. OREMOVE EXISTING EXHAUST FAN AND CAP DUCT. OPROVIDE FIRE DAMPER IN EXISTING OUTSIDE AIR DUCT. OFFSET DUCT AS REQUIRED FOR FIRE DAMPER INSTALLATION. FIELD VERIFY DUCT SIZE. PROVIDE DUCT ACCESS DOOR AND ACCESS DOOR IN CEILING. REUSE EXISTING FIRE DAMPER IF POSSIBLE. OPROVIDE FIRE DAMPER IN EXISTING EXHAUST DUCT. OFFSET DUCT AS REQUIRED FOR FIRE DAMPER INSTALLATION. FIELD VERIFY DUCT SIZE. PROVIDE DUCT ACCESS DOOR AND ACCESS DOOR IN CEILING. REUSE EXISTING FIRE DAMPER IF POSSIBLE. ORELOCATE EXISTING EXHAUST DUCT IN CONFLICT WITH NEW CORRIDOR WALL. 10 EXISTING SUPPLY DIFFUSER TO REMAIN. 11 EXISTING RETURN GRILLE. CEILING IS PLENUM RETURN. 12 NEW SUPPLY DUCT. 13 NEW SUPPLY DIFFUSER. 8x8" TITUS TCD SURFACE MOUNT. 2 -WAY WITH OPPOSED BLADE DAMPER. SCALE: 1/8" = 1' -0" CONTRACTOR SHALL REUSE EXISTING DIFFUSERS WHERE POSSIBLE HVAC DESIGN REQUIRES: YES NO DUCT SMOKE DETECTOR DRAWN FIRE DAMPER(S) CHECKED, DAS SMOKE DAMPER(S) FIRE RATED ENCLOSURE FIRE RATED ROOF /FLOOR CEILING ASSEMBLY FIRE STOPPING SMOKE CONTROL WARNING! sm MECHANICAL EQUIPMENT ORDERED AND DELIVERED TO THE CONSTRUCTION SITE WITH THE WRONG ELECTRICAL CHARACTERISTICS IS A MAJOR SOURCE OF CONSTRUCTION DELAYS, EXTRA COSTS AND LITIGATION. THE CONTRACTOR IS HEREBY NOTIFIED THAT IT IS THEIR RESPONSIBILITY FOR FINAL COORDINATION BETWEEN TRADES TO GUARANTEE THAT ALL EQUIPMENT HAS THE CORRECT ELECTRICAI REQUIREMENTS FOR THE ELECTRICAL DESIGN. THE ENGINEERS' REVIEW OF SHOP DRAWINGS IS FOR THE PURPOSE OF ATTEMPTING TO HELP THE CONTRACTOR CONFORM TO PLANS AND SPECIFICATIONS. CHANGES TO EQUIPMENT AND /OR CHARACTERISTICS CANNOT BE MADE THROUGH THE SHOP DRAWING PROCESS. CHANGES TO EQUIPMENT SPECIFICATIONS CAN ONLY BE MADE THROUGH THE ISSUANCE OF REVISED SIGNED AND SEALED PLANS AND SPECIFICATIONS. "0 THE BEST OF MY KNOWLEDGE, THE PLANS AND SPECIFICATIONS SUBMITTED IEREWITH COMPLY WITH EXISTING INTERPRETATIONS AND PROVISIONS OF THE \PPLICABLE BUILDING CODES. THIS DRAWING IS THE SOLE PROPERTY OF -IENZ ENGINEERING INC.' AND IS AN INSTRUMENT OF SERVICE NOT TO BE tEPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSIO )F HENZ ENGINEERING INC. I, DAVID A. SCHMIDT, P.E. #59492, CERTIFY THAT I CURRENTLY HOLD AN ACTIVE LICENSE IN THE STATE OF FLORIDA AND I AM COMPETENT THROUGH EDUCATION OR FXUFMCIIIN PROVIDE ENGINEERING SERVICES IN THE MECHANICAL I L E I IN THIS PLAN. I FURTHER CERTIFY THAT THIS PLAN WAS (� •8Y. DER MY RESPONSIBLE CHARGE AS DEFINED IN CHAPTER I $ Br 11& ''f. ® OVER I CERTIFY THAT THE COMPANY OFFERING THE II RING S Vi t NZ ENGINEERING INC', HOLDS AN ACTIVE CERTIFICATE A"05 N 80-.TO PROVIDE THE ENGINEERING SERVICE. !". -TATE OF DEC 13 2011 DATE: 4117 RGlf R111G, InC. consULTInG TnGlnim 2320 NE 9th Street, Sulte 200 Fort Lauderdale, Florldo 33304 T 954.523.4933 F 954.523.5052 www.henz.com PROJECT No.: 11098.00 arc NORBERTO ROSENSTEIN ARCHITECT , INC. MCHMCTM — NTM DPI — R M 126 S. FEDERAL HIGHWAY SUITE # 202 DANIA BEACH, FLORIDA 33004 PH: (954) 922 -6551 FAX: (954) 922 -7388 EMAIL- info•rosensteinercNtect.com WEB= www.rosensteinercNtect com STATE REG. NO. AR00I6674 NATL. RECs. NO. 69178 COPYRIC*IT 02005 NOR15ERTO ROSENSTEIN ARCHITECT, AIC. ALL RICsHTS RE5ERIjD. THI5 DOCUMENT OR PARTS THEREOF, MAY NOT SE REPRODUCED IN ANY FORM UdT'HOUT PERMISSION DESIGNED "_4::� =t DRAWN CHECKED, DAS -�•� ,. J I HEREBY CERTIFY THAT THESE PLANS WHERE PREPARED BY ME OR UNDER MY SUPERVISION, AND TO THE BEST OF MY KNOWLEDGE, COMPLY WITH ALL APPLICABLE CODES. LLU I OWNER REVISION 11/03/11 R E V I S 1 0 N S COMM. DATE 2011 -37 0/1/2011 5701 SUNSET DR SUITE A15A WHITE BOX 5OUTH MIAMI FLORIDA, 33143 MECHANICAL P LAN M -1 El 1