14-88-0241/17/2014 10:33 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5
WALLS
Ornt
Adjacent
Tn Wall-Type
Space Cavity Width Height Sheathing Framing Solar
p Ahznr
Below
rrqdeO/.
1 N
2 E
3 S
4 W
Exterior Concrete Block - Int Insul 1 st Floor 5 10 10 100 ft2 0 0.3
Exterior Concrete Block - Int Insul 1st Floor 5 6 10 60 ft2 0 0.3
Exterior Concrete Block - Int Insul 1 st Floor 5 20 10 200 ft2 0 0.3
Exterior Concrete Block - Int Insul 1 st Floor 5 40.4 10 404 ft2 0 0.3
0
0
0
0
DOORS
#
Ornt Door Type
Space Storms U -Value Width Height
Ft In Ft In
Area
1
N Insulated
1st Floor None 0.2 0.1 0.1 0.010000
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
�/ #
Wall
Ornt ID Frame Panes
Overhang
NFRC U- Factor SHGC Area Depth Separation Int Shade
Screening
1
W 4 Metal Single (Clear) Yes 1.5 0.5 36 ft2 4 ft 0 in 2 ft 0 in Drapes /blinds
None
INFILTRATION
# Scope
Method
SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Best Guess
0.000500 525.91 28.872 54.298 0.3450 9.8363
HEATING SYSTEM
#
System Type
Subtype Efficiency Capacity Block
Ducts
1
Electric Strip Heat
None COP: 1 17.4 kBtu /hr 1
sys #1
COOLING SYSTEM
#
System Type
Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit
Split SEER: 14 41.4 kBtu /hr 1242 cfm 0.75 1
sys #1
HOT WATER SYSTEM
#
System Type SubType
Location EF Cap Use SetPnt Conservation
1
Electric Tankless
Exterior 0.98 1 gal 40 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume FEF
None None
ft2
1/17/2014 10:33 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5