Loading...
14-88-022FORM 405 -10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: ADDITION RESIDENCE Builder Name: Street: 4301 SW 60TH STREET Permit Office: City, State, Zip: MIAMI , FL , 33155- Permit Number: Owner: Jurisdiction: 231000 Design Location: FL, Miami 1. New construction or existing Addition 9. Wall Types (764.0 sqft.) Insulation Area 2. Single family or multiple family Single- family a. Concrete Block - Int Insul, Exterior R =5.0 764.00 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft 2 4. Number of Bedrooms(Bedrms In Addition) 1(1) d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (401.0 sqft.) Insulation Area a. Under Attic (Vented) R =30.0 401.00 ft2 6. Conditioned floor area above grade (W) 401 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(36.0 sqft.) Description Area a. Sup: Attic, Ret: 1st Floor, AH: 1st Floor 6 47 a. U- Factor: Sgl, U =1.50 36.00 ft2 SHGC: SHGC =0.50 b. U- Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 41.4 SEER:14.00 c. U- Factor: N/A ft2 SHGC: 13. Heating systems kBtu /hr Efficiency d. U- Factor: N/A ft2 a. Electric Strip Heat 17.4 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 4.000 ft. Area Weighted Average SHGC: 0.500 14. Hot water systems - Supplemental for addition 8. Floor Types (401.0 sqft.) Insulation Area a. Electric Tankless Cap: 1 gallons a. Slab -On -Grade Edge Insulation R =0.0 401.00 ft2 b. Conservation features E F: 1.065 b. N/A R= ft2 None c. N/A R= ft2 15. Credits CV, Pstat Total Proposed Modified Loads: 15.07 Glass /Floor Area: 0.090 tiff PASS a rd Reference Loads: 20.48 I hereby certify that the pl ¢Sp�c� cations�ovAr•�f b %, Review of the plans and S� this calculation are in corr�lianqb with the F Ene%y 5 T4 2 specifications covered by this O4'ti;E =_ ; , O 8 .202 Code. - calculation indicates compliance y`� �i„ ' _. €s''.��` •C� = PREPA Eq Y: with the Florida Energy Code. Before is � rnn •, ,,.,• ,••�„ D ? �T� ©�•• DATE: construction completed this building will be inspected for compliance with Section 553.908 y r ••:c� O R10P,.�\� `���.� I hereby erti t t this buildii'tg�� �i m,d'T 4101iance fY h� �NAL Florida Statutes. C with the Florida Energy Code. �i,,, a�•O Olj WE �lHh4rllOpµ+ll��� OWNER /AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist - Cool sys #1 may be undersized. Size of 41.4 was Increased to 41.4 for simulation. Please review the Manual J8 report. 1/17/2014 10:33 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5