07-43-0399
N
U
6 -r-
Q)
N ya N
-6 E
aO � OI
N O
Q) �
E o
�L9-u
� o o s
`•` N O �o
U V
•� � QI
>
E- o�
u�Uii
� U '
��surn
O 0 O
�• --ate
o�
> '� Q
n
� (3
N �
u �
>Uq)
qV
U U
O
V > ,
Q)
QI ^
��CQs
� T5
W N U
z f- O
� 'ai V co O
N
Z O�
z 10
m Q O •�
zu O
oi=o�
=U
1 jT Sl
a
• p m � L
� •E 9 U
v
°X: -u
N
9 •i N 7
U O U
U i7- i�
ZD
E � •U � o
a�
J0
1 L �
's L
1 o j N
u
1 i4 �Y L
1 QI �r. •v= �}
U � E
o > >�o
1 No�u
0
n
c
13
�;oao
`6 V
N ^
Q O E O
z a-
�o�o
Z���
N LU U Z U
4- - S
q)
E
Q L
O
N
� u v2
W
_j
M =3 .6
Cp to
O
O 3L
UQ[II�
GROUNDING
ELECTRODE
GROUNDING
CONCRETE FOUNDATION
2 in. -
MIN. Ili -
BOLTED -TYPE
CONNECTION DEVICE
OR EXOTHERMIC WELD.
NONMETALLIC
PROTECTIVE
SLEEVE.
- No. 4 AWGs OR LAR2ER BA
COPPER CONDUCTOR OR 8 EEL
REINFORCING BAR OR ROD NOT
LESS THAN 1/2 -INCH PI R
20 FT
MIN.
ENCASED GROUNDING ELECTRODE DETAIL
NITS.
CONNECT TO A CONCRETE - ENCASED
ELECTRODE CON518TiNG OF AT LEAST
20 FT OF ONE OR MORE BARE OR ZINC
GALVANIZED STEEL REINFORCING BARS
OF NOT LESS THAN 1/2 INCH OR CONSISTING
OF AT LEAST 20 FT. OF BARE COPPER
CONDUCTOR NOT SMALLER THAN No. 4 AND
LOCATED WITHIN AND NFAR THE BOTTOM
OF A CONCRETE FOUNDATION OR FOOTING
THAT 18 iN DIRECT CONTACT WITH EARTH.
150 AMP5
DISC BRK
(NEMA 3R)
ELECTRICAL METER
TWO SETB OF 3 +3/0
THUN - 2' COND.
6SRViCE BY FPI_
DIRECT CONTACT
WITH EARTH.
3P 1/0 TI 1 N - )5' COND-
AND 1 s 6 (G)
30 3/0 THE N
2' COND.
200 AMPS
8 X a GUTTER D15C BRIG
NEMA 3R (NEMA 3R)
TWO 5ET5 OF 3 *3/0
THUN - 2' EA.
1_ I - 2 CU (GRD
PER NECJ
CONNECT TO A
CONCRETE- ENCASED
ELECTRODE DETAIL)
CONNECT TO A 3!4' COPPER
WATER FIRE 8TU5-OUT
200 AMPS
ELECT PANEL -A
WALL A55EMBLY - U.L. bYbTEM UJL-1039
FISE PENETRA -TION DETAIL
�RnoF TRU5515=5
ELECTRICAL
WIRES
ATTIC
CLOSET
UL SYSTEM NO WL 3044
P- RATING;: 1 OR 2 HR. T RATING: 1, 111/2'
SEALANT D1=PTH 11/2' WiTH 1/2' CROWN,
SEALANT TO BE MANUFACTURED BY
TREM8TOP IA
ISO AMP8 ELECT
PANEL-15
ELECTRICAL RISER
N.T.5
CONCRETE - ENCASED ELECTRODE. M Electrode encased by at last 2'
of concrete, located within and near the bottom of a concrete
foundation or footing that is in direct contact w/ the earth,
consisting of at least 20'of one or more steel reinforcing bars
or rods of not lass than 1/2' diameter or consisting of at least 20'
of bare copper conductor not smaller than 0 ALr;L
ELECTRiCAL LOAD CALCULATION
ITEM
PANEL -A
PANEL -B
SERVICE
5Q.FT.
2,000
2,104
GENERAL L IG gTING
6,000
1,911
SHALL APPLIANCES
4,500
COOK TOP
1,000
REFRIGERATOR
1,000
DISHWASHER
1,200
W45HER
1,500
DRYER
5,000
WATER HEATER
4,500
4,500
DISPOSAL
150
OVEN
6,000
ICE MAKER
FREEZER
JACUZZI
WINE COOLER
COMPACTOR
DOOR OPENER
1,600
5PRfNKLER PUMP
POOL EQUIPMENT
MICROWAVE
1,000
CONNECTED LOAD (LE55 A /C)
36,950
20,112
10 KW .0 100.
10,000
10,000
REST e 40%
8,180
4,285
A/C or HTNGs Q 100:
11,000
11,000
DEMAND LOAD WATTS
31,180
25,285
PHASE AMPS.
132
105
231
SERVICE SIZE
200
150
NEUTRAL LOAD
LIGHTING,WASHER,5MALL APPL
12,000
5,612
3 KW al 1001.
3,000
3,000
REST 9 35%
3,150
2,314
COOK TOP 9 10%
4,1300
OVEN lo 10%.
4,200
DRYER 9 10%
3,500
115 V APPL.
3,'350
1,(200
TOTAL NEUTRAL W.
19,200
10,414
NEUTRAL AMPS.
80
43
123
TRIEMP3T0P IA
GOTHS SIDES
I -HR. FiRE
RATED CEiLiNG
ELECTRICAL NOS
I. CONTRACTOR SHALL FURNISH ALL LABOR MATERIALS AND
EWIPMENT FOR COMPLETE ELECTRICAL INSTALLATION IN
ACCORDANCE WITH THESE DRAWINGS.
1. COMPLY WITH THE NEC. AND THE SOUTH FLORIDA BUILDING CODE
3. PROVIDE EMPTY CONDUITS AS REOJIRED FOR TELEPHONE SYSTEM
4. OBTAIN ALL PERMITS FOR WOW UNDER THIS CONTACT.
5. PROVIDE TEMPORARY POWER AND LIGHT OUTLETS FOR USE BY
OTHER TRADES.
6. NO APPLIANCES OUTLES SHALL BE INSTALLED BELOW BASE FLOOD ELEV -
1. COORDNATE ALL OUTLET LOCATIONS WITH BUILDING
ARCHITECTURAL FEATURES.
* CONTRACTOR SHALL 1ASiT THE SITE TO FAMILIARIZE HIMSELF
WITH ALL EXISTING CONDITIONS.
* A/C COMPRESSOR SHALL 13E INSTALLED ABOVE BASE FLOOD ELEV_
lo. OUTDOOR CONDUITS SHALL BE SCHEDULE 40 PVC
MINIMUM COVER SHALL BE 24'.
1L ALL MOUNTING HARDWARE SHALL BE BY CONTRACTOR.
11. ELECTRICAL OUTLETS BELOW BASE ELEV. SHALL BE INSTALLED AT THE
HIGHEST PERMITTED ELEV AND SHALL BE INSTALLED (SEPARATE) AS
r V 4 W V u
v V V V u
V W V
.W Q'
u i
V
V
L W Y W V
V W V V V
V W U U
Y V V V
y y WWY
S
vRr�
W u Y
u W 4 Y u u W V V W V V V V V u v V u v
i
I
12901 S.W. 132 AVE
MIAMI, FLORIDA 33186
T. (305) 278 -7776
F. (305) 278 -7473
WWW.BELLONMILANES.COM
AA- 0003505
ARCHITECTURE
LAND PLANNING
INTERIORS
CONSTRUCTION MANAGEMENT
W
0
Z
W
0
W Q
Ir W d
a cc
0
j LL
W Ed Q
W n o
(1) to
J
W
L
DATE: 02 -13 -01
DRAWN: ALEX P - AP - J.P
CHECKED: A.P
PROD. NO: 200(oL8052
1.
2.
0
BDC: BUILDING DEPT. COMMENTS