07-43-0382 In,
MIN.
GROUNDING
ELECTRODE
GROUNDING
15OLTED -TYPE
CONNECTION DEVICE
OR EXOTHERMIC: WELD.
NONMETALLIC
PROTECTIVE
SLEEVE.
No. 4 AWCx OR LAW ER BA
- . COPPER CONDUCTOR OR 5 E
REINFORCING BAR OR RO NC
LE55 THAN 1/2 -INC44 DIAME R.
ND FT --I `-
MIN.
ENCASED GROUNDING
ELECTRODE DETAIL
NTS.
CONNI =CT TO A CONCRETE= - INCASED
ELE=CTRODE CONSISTING OF AT LEAST
20 FT OF ONE OR MORE BARE OR ZINC
GALVANIZED STE=EL REINFORCING BARS
OF NOT LESS THAN 1/7 INCH OR CON515TING
OF AT LEAST 20 FT. OF BARE COPPER
CONDUCTOR NOT SMALLE=R THAN No. 4 AND
LOCATED WITHIN AND NEAR THE BOTTOM
OF A CONCRETE FOUNDATION OR FOOTING
THAT 15 IN DIRECT CONTACT WITH EARTH.
150 AMPS
DISC aw
(NEMA 3R)
ELECTRICAL METER
DIRECT CONTACT
WITH EARTH.
WALL ASSEMBLY - U.L. SYSTEM WL -1039
EIRE FENETRATION DET�411-
-ROOF TRUSSES
I/ i ELECTRICAL
ATTIC
CLOSET
UL SYSTEM Nt WL 3044
F- RATING: 1 OR 2 HR. T RATING: 1, 111/2'
SEALANT DEPTH 11/2' WITH 1/2' CROWN,
SEALANT TO BE MANUFACTURED BY
TREMSTOP IA
3• v0 TH-N - X' CoND.
AND 1 • b (G)
3.3/0 THHN
2' COND.
200 AMPS
b X 5 GUTTER DISC 13FK
NEMA 3R (NEMA 3R)
•310
TWO SETS 3.3/0
I �
TWO SET'S OF 3
T"
T - 2' EAA .
E
THWN - 2' COND.
60i=T,
SERVICE BY FPL
2,104
I •2 Cu (CsRD
6,000
PER NEC.)
CONNECT TO A
SMALL APPLIANCE5
CONCRETE - ENCASED
ELECTROPIE (SEE
COOK TOP
DETAIL)
y
_ CONNECT TO A 3/•1" COPPER
WATER PIPE STUB -OUT
15+0 AMPS ELECT
PANEL-5
200 AMPS
ELECT PANEL -A
ELECTRICAL RIS
N.T.S
CC 4CRETE- ENCASED ELECTRODE. An Electrode encased bg at least 2'
of concrete, located within and near the bottom of a concrete
l'oundatlon or footing that is in direct contact w/ the earth,
consisting of at least 20'of one or more steel reinforcing bars
or rods of not less than 1/2' diameter or consisting or at least 20'
of bare copper conductor not smaller than • f. AWS.
ELECTRICAL LOAD CALCULATION
ITEM
PANEL -A
PANEL-5
SERVICE
60i=T,
2000
2,104
GENERAL LIGHTING
6,000
7,917
SMALL APPLIANCE5
4,500
COOK TOP
1,000
REFRIGERATOR
1,000
DISHWASHER
i)OO
WASHER
1,500
DRYER
5,000
WATER HEATER
4,500
4,500
DISPOSAL
150
OVEN
(0,000
ICE MAKER
FREEZER
JACUZZI
WINE COOLER
COMPACTOR
DOOR OPENER
1k_0
SPRINKLER PUMP
2,000
POOL EQUIPMENT
Z11
MICROWAVE
1,000
--
CONNECTED LOAD (LESS A /C)
uo cno
22,112 I
10 KW 100%
10,000
10,000
REST a 40%
B,ZSO
5,_84
A/C or HTNG * 100%
11,000
11,000
DEMAND LOAD WATTS
31,100
26,085
PHASE AMPS.
132
108
240
SERVICE SIZE
200
150
NEUTRAL_ LOAD
LIGHTING,WA5HEER,5MALL APPL.
12,000
9,612
3 KW 100%
3,000
3,000
REST 35%
3,150
2,314
COOK TOP 9 10%
4,900
OVEN 'D 10%
4)00
DRYER Q 10%
3,500
115 V APPL.
3,950
1,600
TOTAL NEUTRAL W.
19,200
10,414
NEUTRAL AMPS.
50
43
123
r
TREMPSTOP IA
MOTHS SIDES
I -HR. FIRE
RATED CEILING
ELECTRICAL_ NOTES
L CONTRACTOR SHALL FUR415H ALL LABOR MATERIALS AND
EQUIPMENT FOR COMPLETE ELECTRICAL INSTALLATION IN
ACCORDANCE WITH THESE DRAWINGS.
2. COMPLY WITH THE NEC. AND THE SOUTH FLORIDA BUILDING CODE
3. PROVIDE EMPTY CONDUITS AS REQUIFED FOR TELEPHONE SYSTEM.
4. OBTAIN ALL PEWITS FOR WORK UNDER THIS CONTACT.
5. PROVIDES TEMPORARY POWER AND LIGHT OUTLETS FOR USE BY
OTHE=R TRADES.
6. NO APPLIANCES OUTLES SHALL BE INSTALLED BELOW BASE FLOOD ELEV.
1. COORDINATE ALL OUTLET LOCATIONS WITH BUILPM
ARCHITECTURAL FEATURES.
8. CONTRACTOR SHALL A51T THE SITE TO FAMILIARIZE HIMSELF
WITH ALL EXISTING CONDITIONS.
9, A/C COMPRESSOR SHALL BE INSTALLED ABOVE BASE FLOOD ELEV.
10. OUTDOOR CONDUITS SHALL BE SCHEDULE 40 PVC.
MINIMUM COVER SHALL BE 24'.
It ALL MOUNTING HARDWARE SHALL BE BY CONTRACTOR.
12. ELECTRICAL OUTLETS BELOW 15A5E ELEV. SHALL BE INSTALLED AT THE
HIGHEST F'EWITTED ELEV AND SHALL BE INSTALLED (SEPARATE) AS
12901 S.W. 132 AVE
MIAMI, FLORIDA 33186
T. (305) 278 -7776
F. (305) 278 -7473
WWW.BELLONMILANES.COM
AA- 0003505
ARCHITECTURE
LAND PLANNING
INTERIORS
CONSTRUCTION MANAGEMENT
W
U
z
W
r0
VJ
W
tr
VJ Q
(3) a
W L0 LL
W vi a
IL o
.G c0
rWr� Q
VJ Cl)
--J
W
r)
V
"77".
DATE: 02 -13 -01
DRAWN: ALEX P - A.P - J.P
CHECKED: A.P
PROJ. NO: 2006LE052
1. OS -22 -01 E.D.C.
2.
3.
4.
BDC: BUILDING DEPT. COMMENTS
CC: COORDINATION CHANGES
AB: A �-,$UILT
R ; R 1�Of�� �6TE�' APl'170
A
1 � � .� � ; 304'7
L OPO-�Q �,BELLON•;.,A'IA
' AR 008737,' '"
ANGEL MILANES, AIA
AR- 0015845
E -2
OF