Loading...
07-43-028i - •u O E � VI Q) 0 6 u� � E O fro' - �L Qu O O N o U V iz `w ai O U m 0 :3 cD 0 U u u ° CONCRETE FOC m SEE SCHEDULE u � ) O- u�,. u z 4 �l U TF ul loom 0 6 Quo7� \ z �o p o u m`O_� �w�o � :z �Q� a �z"� cS�NQ3 rn v Lu u • p SIl Q) �Q)�Q Ea � o 9 1 u I 'Ea Q) u L 1 m -O O -a I _ m rn��N L N��� T- Q o E n E z°)� i � O Q) O Zro QN UUJ 3 v r U �fy t" E Q z� ao z _ N oau u (k m O'ui.u� UQmtu ADD I05 CORNER BAR AT TOP 4 BOTTOM OF REAM SO HOOK AT ALL / TOP BARS 2 • 5 BARS — COL.BARS (1) EACH FACE SEE SCHEDULE (TOP PLAN SHOWN) ARCH DETAIL O 1 M 5 VERTICAL IN CONCI -ILLED CELL (SEE FOUNDATION FOR LOCATION) PRL. W.M. Q PERIM_ 30' VAPOR BARRIE THICKENED SLAB AT SEE SCHED.) ALL EXTERIOR WALL TYPICAL PERIMETER FOOTING 8'X16' OR 16'X16" CONC.BLKCOL_ W/105 a EA.CELL NOOK AND PAD (SEE FOUNDATION PLAN FOR FILLED LOCATION) Q MY � tQ W cy X o � x x— 3' -0" X 3' -0' X 12" CONC.PAD W/305 EA.LUAY (TYR.) PAD DETAIL 9 ADD 1 11 5 CORNER BAR AT TOP E BOT. OF BEAM 906 HOOK AT ALL TOP BARS BEAM STIRRUPS 4'+ 12 ",w CORNERS BAL.p 48' O.C. BEAM CORNER PLAN 6'X12' GONC,TIE BEAM 405,03 TIES 0 48'C G. u { 0 U 12' HOOK b" 13ELOW TOP OF TwTYP.) DBL TIES FLUOR LINE DBLTIES 10 TYP.COLUMN SPLICE DETAIL O GARAGE OHJDOOR 2'X6' P.T. W/5/8' * X 4' PENET. KWIK.BOLTS BY HILTI t 12' G.C. 3' FROM TOP t 50T. *A F-] E� STUCCO � 4 + 5 CONT. ` 8' CMU_ WALL TYPICAL OVERHEAD DOOR GARAGE DETAIL O 2 * 5 CONT. E55 SLIDING GLASS DOOR SILL DETAIL 6'X12' GONC.TIE BEAM F-2 « 5 CONT. I W: \ . 1# 5 CONT. 4'5,03 TIES * 481cc. 10 5 M GONG. FILLED CELL WINDOW OPENING (BEARING END) (5EA BEAM DROP DETAIL GENERAL STRUCTURAL NOTES 2.5 Nr-� VAPOR BARRIER W.W.F. O 1 0 5 CONT. • V V W • V u Y �. +� i Y • i ` . � � W r• W y v V y W V - e« • YYV V l V • Y i u �% y V Y Y Y V V V y Y • • Y V y V y W •YY•• �� Q � �IF V • � V � w 4 V V • y u V•• • r• W Y V W Y v 12901 S.W. 132 AVE MIAMI, FLORIDA 33186 THICKENED EDGE DETAIL 1 0 5 CONT. T. (305) 278 -7776 F. (305) 278 -7473 Q WWW.BELLONMILANES.COM AA- 0003505 END) O TYP.STEP IN SLAB O TYP.DROP SLAB O 1. GENERAL A. THE CONTRACTOR SHALL FIELD -CHECK ALL DIMENSIONS ON THE STRUCTURAL DRAWINGS AND VERIFY THE SAME ON THE ARCHITECTURAL SET_ ARCHITECTURAL DETAILS SUCH ASt SLAB DEPRESSIONS, WATERPROOFING, CURBS, MECHANICAL OPENINGS, FASCIA FRAMING AND BRACING SHALL BE INSTALLED AS SHOWN ON THE ARCHITECTURAL SET_ B_ THE CONTRACTOR SHALL BE RESPONSIBLE FOR SHORING AN BRACING TO ENSURE SAFE - WORKING CONDITIONS AT ALL TIMES_ ALL CONSTRUCTION SHALL CONFORM TO THE FLORIDA BUILDING CODE 2004_ 2. CONCRETE A_ ALL CASTING IN PLACE CONCRETE IN THIS JOB SHALL ATTAIN A MINIMUM COMPRESSIVE STRENGTH(Vc) AT 28 DAYS OF 3000 B. CONCRETE WORK SHALL CONFORM TO ALL REQUIREMENTS OF ACI -301 (2002) SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDING_ 3. REINFORCING STEEL A. REINFORCING STEEL SHALL BE DETAILED AND PLACED IN ACCORDANCE WITH ACI -318 (2002) B. REINFORCING STEEL SHALL BE DEFORMED BAR'S CONFORMING TO ASTM A 615 GRADE 60, UNLESS OTHERWISE NOTED. C_ ALL WELDED WIRE FABRIC SHALL CONFORM TO ASTM A 185. D. REINFORCING TO BE SECURELY IN POSITION WITH STANDARD ACCESSORIES DURING PLACING OF CONCRETE. E. ALL BOTTOM BARS SHALL BEAR 6' MINIMUM OVER SUPPORTS. 4.MINIMUM CONCRETE OVER REINFORCING MINIMUM CLEAR COVER (IN.) A CONCRETE AGAINST AND PERMANENTLY EXPOSED TO EARTH (UNFORMED FACES) 3 5. CONCRETE EXPOSED TO EARTH OR WEATHER (FORMED FACES): A. 06 BARS AND LARGER 2 5.05 BARS AND SMALLER 11/2 G. NOT IN CONTACT WITH GROUND 3/4' A. STRUCTURAL SLA55 t WALLS B. BEAMS AND COLUMNS(PRIMARY REINFORCEMENT, TIES STIRRUPS 8 SPIRALS) 1 -1/2' C. SLABS ON GRADE OVER VAPOR BARRIER 1 -1/2' 51" IASONRY A_ HOLLOW CONCRETE MASONRY UNITS SHALL BE OF A QUALITY OF AT LEAST EQUAL TO THAT REQUIRED BY ASTM C S0 'STANDARD SPECIFICATIONS FOR HOLLOW LOAD BEARING CONCRETE MASONRY UNITS'. 5. ALL MORTAR SHALL COMPLY WITH THE PROPERTY AND PROPORTION SPECIFICATIONS OF ASTM G 210. EXCEPT THAT SLAG CEMENTS SHALL NO BE USED. MORTAR FOR EXTERIOR WALLS SHALL BE TYPE M. FOR INTERIOR LOAD BEARING WALLS THE MORTAR SHALL BE TYPE M OR S. FOR INTERIOR WALLS A50VE GRADE AND NOT SUPPORTING LOADS THE MORTAR SHALL BE TYPE M, S, OR N. C. WHENEVER ANCHOR BOLTS ARE TO BE SET IN MASONRY, TWO CELLS AT THE SETTING LOCATION SHALL BE FILLED WITH CONCRETE. D. GROUT FOR MASONRY UNITS SHALL CONFORM TO ASTM C 41(o AND SHALL ATTAIN A COMPRESSIVE STRENGTH OF F'C- 3000 P.S.I, AT 28 DAYS. E. MINIMUM COMPRESSIVE STRENGTH OF UNIT MASONRY 1900 PSI RESULTING TO PRISM STRENGTH OF 1500 PSI. F. MAXIMUM POUR LIFT FOR MASONRY UNITS AND GROUT POUR HEIGHT SHALL BE 4' -0'. G. SLUMP S' + 1'_ 6.STRUCTURAL STEEL A. STRUCTURAL STEELWORK SHALL COMPLY WITH AISC 'SPECIFICATIONS FOR THE DESIGN, FABRICATIONS AND ERECTIONS OR BUILDINGS' AS IT APPEARS ON THE MANUAL OF STEEL CONSTRUCTION, LATEST EDITION. 5. STRUCTURAL STEEL SHAPES, BARS, PLATES AND PIPES SHALL CONFORM TO ASTM A 36, FY= 36 KSI_ C. STRUCTURAL STEEL TUBING SHALL CONFORM TO ASTM A 46, FY= t 46 KSI. 1. STRUCTURAL LUMBER A. QUALITY OF WOOD TO CONFORM WITH FLORIDA BUILDING CODE 2004 5. WOOD SHALL BE OF A GRADE OF NOT LESS THAN 1,000 P,S.f. OF NORMAL EXTREME FIBER STRESS. SOUTHERN PINE STRUCTURAL GRADE * 2 OR BETTER C. ALL WOOD IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE TREATED. S. WOOD TRUSSES A. TRUSSES TO BE DESIGNED AND FABRICATED TO MEET THE REQUIREMENTS OF NATIONAL DESIGN SPECIFICATIONS FOR STRUCTURAL GRADE LUMBER AND ITS FASTENINGS AND TIMBER CONSTRUCTION STANDARD BY TPI. TRUSSES SHALL BE DESIGNED FOR SUPERIMPOSED LOADS INDICATED IN PLAN. 5. TRUSSES SHALL BE ENGINEERED TO SPAN THE CONFIGURATION INDICATED ON DRAWINGS, PROVIDE(3) COPIES 24' X 36' OF TRUSS DRAWINGS AND ENGINEER'S CALCULATIONS WITH SEAL OF REGISTERED ENGINEER IN THE STATE OF FLORIDA FOR ARCHITECT'S APPROVAL PRIOR TO FABRICATION. C. ALL ROOF JOISTS, TRUSSES, LOOKOUTS, BEAMS 4 GIRDERS SHALL BE SECURED WITH APPROVED METAL TIES, CLIPS AND ANCHORS AT CONNECTIONS. SEE CONNECTION NOTES 4 DETAILS) F ; soUi 'l� [ "'llcirni "Ili ;1i Dop, -rtm i li ARCHITECTURE LAND PLANNING INTERIORS CONSTRUCTION MANAGEMENT w U Z w 0 U) W rn4 � U) O W LL Wclj a IL o > C-3 H w N o U) cn w ►, DATE: 02 -13 -01 DRAWN: ALEX P - A.P - J.P CHECKED: A -P PROJ. NO: 20061-5052 1. 2. 3. BDC: BUILDING DEPT. COMMENTS CC:` - COORDINATION- CHANGES AB- tSidWN ASTER` APPROVAL LEOPOLDO BELLON, AIA AR- 008737 ANGEL MILANES, AIA AR- 0015845 s S -3 OF