TRACK BRACKET OR
AS PER TABLB FEnON OF FRC. 2W4
4' PRECAST 5AND
GARAGE DOOR REGULAR ANGLE
ROOT TRUSS
UNSPRINKLERED:
AS PER TABLE 803.5 (F.B.C.) `
EXITS ACCESS OTHER SPACES
2'xb' P.T. W/ Vx4' * 24' or- 6'
1
FROM TOP 4 BOTT. OR 3i(t,'x3'
CLASSIFICATION.
_ n
POWER DRIVEN PINS 0 t' cc.
AS PER (R315.1 FBC 2004)
CLASS C: INTERIOR WALL AND CEILING
3' FROM TOP 4 BOTT.
FINISH. FLAME SPREAD 76 -200, SMOKE
FLAME- SPREAD CLASSIFICATION OF NOT GREATER
DEVELOPMENT 0 -450. INCLUDES ANY
LATCHES
MATFRIAL CLASSIFIED AT MORE THAN 25
STOP MOULDING
BUT NO MORE THAN 200 ON THE FLAME
AS PER (R315.2 FBC 2004)
MASONRY
22' X 30' ATTIC ACCESS
W126 GAMETAL CLAD COVER
ON SMOKE TEST SCALE. AS PER NFPA
SMOKE - DEVELOPED INDEX OF NOT GREATER
ON 5/8' EXT.PWD.1 HR.FIRE RATED
THAN 450.
3%. MIN.
(MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT)
RESIDENCE 4,704 S.F. / 200 = 23 PERSONS
SIDE ROOM
ATTIC ACCESS MUST BE LOCATED AT A POINT WHERE
DECORATIVE IRON WORK
AS PER CHAPTER 6 - SECTION 602.3 F.B.C. 2004 TYPE III
THERE 15 A MINIMUM 30' HEADROOM. F5C'04 8807.1
5Y OTHERS.
AS PER TABLE 601 (F.B.C.) 2004 TYPE III
(FIRE- RESISTANCE RATING REQ. FOR ILDG. ELEMENTS)
C MANUFACTURER TO PROVIDE
(FIRE - RESISTANCE RATING REQ. FOR EXT. WALLS BASED ON FIRE SEP. DISTANCE)
SHOP P11*5. TO ARCH. FOR APPROVAL)
GARAGE DOOR JAMB DETAIL
2
ATTIC ACCE55 DETAIL.
3
DECORATIVE PRECAST DETAIL
N_T_S.
N.T.S.
N.T.S.
Ilk 20' SECOND MEANS OF SCAPE WINDOWS
EGRESS WINDOW AS SECOND MEANS OF ESCAPE TO
HAVE AN OUTSIDE WINDOW OR DOOR OPERABLE
FROM THE INSIDE WITHOUT THE USE OF TOOLS AND
PROVIDING A CLEAR OPENING OF NOT LESS THAN
20 IN, IN WIDTH, 24 IN. IN HEIGHT AND 5.1 SQFT. IN
AREA AS PER SECTION R31OJ3 FB.0 2004 ED
rt
n
'
CEILING (SEE FINISH
� x MAXIMUM HEIGHT FROM FLOOR:
I SCHEDULE, TYP)
�
THE EMERGENCY ESCAPE AND RESCUE OPENING
SHALL HAVE A SILL HEIGHT OF NOT MORE THAN
3 5/6' 25 GA. METAL
44 INCHES (1118 MM) ABOVE THE FLOOR AS PER
RUNNER, (TYPICAL)
SECTION R310 F.B.0 2004 ED
I
1
'
I
I
4
EGRE55 WINDOW
N.T.S.
I
I
'
1/2' G.W.B. ON 3 5/8' 25 GA.
CEILING
METAL STUDS a 24' O.C. ON
2 X 6 WD. F=KING
CONC. TB SEE STRUCTURAL
I BOTH SIDES, (TYP)
FOR CAB. BACKING
5/8" SMOOTH STUCCO DRAWINGS
I
I
EXT. FINISH
I
� �
. /
DRYWALL ON 1110.
WAL!``q NET
FURRING (SEE TYPICAL
'
SEctION)
2 X 4 WD. BACKING At /• •�
�'. - r •
BOT_ OF WALL CABINET
1
CERAMIC TILE ON CBU_
AND AT WALL HUNG
PLUMBING FIXTURES // `�
2x6 WOOD
WHERE OCCURS - (SEE
I
- (CUT t0 4 -1/2 )
(CUT
' W/3 -I/2'X 1/4'; TAPGONS
FINISH SCHED)
COUNTERTOP
` At 4' OF EDGES 4 IN THE
MIDDLE (MAX. DIST. I' -4' OTC)
I
1 3 5/8' 25 GA
2 X 4 WOOD
77�
I METAL RUNNI =I�
g�lWs * TOP
3/4' DRIP MOLDING
SEALANT i (TYPICAL)
BASE CABINET
BOTH SIDES.
I
``'- - WOOD DOOR
-------
EXTERIOR INTERIOR
INTERIOR PARTITION
3 -5/8" METAL STUDS MIN
20 GA AT 16' O.0 (TYP)
NOTE: FOR SLIDING GLASS DOORS JAMB AND HEADER USE
MR FBC 2004
84411.45.1.1
1X4 P.T. Wp. ATTACHED W/ 1 -1/2 TAPCONS + 16' O.G. (TYP.)
NON -RATED PARTITION
W001D BACKING DETAIL
g
DOOR HEAD DETAIL
N.T.S.
N.T.S.
N.T.S.
5/8" DRYWALL ON WP.
_.
FURRING (SEE TYPICAL
SEE SCHEDULED
SECTION)
WINDOWS
INTERIOR 3/4' WD. NAILER
DRYWALL ON WD. MOLDING
= ,,. •
'
WD. BLOCKING
FURRING (SEE TYPICAL
": , .•
".SECTION)
� • STUCCO
4' PRECAST SILL
AL
FINISH
$/8' DRYWALL ON
DOOR FRAME
SCHI =DUL1=
WD. FURRING (SEE
INSULATION
TYPICAL SECTION)
..
CONC. COL. OR GMIJ '
.
SEE STRUCTURAL ► ,' ..
+ ,� '.
DRAWINGS • .
CONC. TIE BEAM (SEE .. 4 PRECAST
.
STRUCT. DWG 5) MOULDING
•
..
..,
LIGHT TEXT STUCCO
2 X PT_ WOOD
••
FINISH.
W /3 -V, x 1/4' TAPCONS
0 BOTTOM At 8' O.C. • • METAL DOOR
SCHEDULE
'SCHEDULED INSULATION
�
WINDOWS
CMU WALL
W/ BACKER ROD
SEALANT
SMOOTH STUCCO CONT. SEALANT
EXT. FINISH
- �1-
EXTERIOR
PRECA5T WINDOWS
WINDOW 5ILL 4 ANCHOR DETAIL
C3
1�
jj
DOOR BI LK DETAIL
LINTEL ANC;POR DETAIL
N.T.S.
N.T.S.
N_T.S.
BUILDING COMPLIANCE
AS PER TABLB FEnON OF FRC. 2W4
OCCUPANCY CLASSIFICATION
AS PER CHAPTER 3 SECTION 311.2 > USED: GROUP (R -3) (RESIDENTIAL)
UNSPRINKLERED:
AS PER TABLE 803.5 (F.B.C.) `
EXITS ACCESS OTHER SPACES
MINIMUM INTERIOR FINISH
C C C
CLASSIFICATION.
CLASS
AS PER (R315.1 FBC 2004)
CLASS C: INTERIOR WALL AND CEILING
WALL ANDS CEILING FINISHES SHALL HAVE A
FINISH. FLAME SPREAD 76 -200, SMOKE
FLAME- SPREAD CLASSIFICATION OF NOT GREATER
DEVELOPMENT 0 -450. INCLUDES ANY
THAN 200.
MATFRIAL CLASSIFIED AT MORE THAN 25
BUT NO MORE THAN 200 ON THE FLAME
AS PER (R315.2 FBC 2004)
SPREAD TEST SCALE AND 450 OR LESS
WALL AND CEILING FINISHES SHALL HAVE A
ON SMOKE TEST SCALE. AS PER NFPA
SMOKE - DEVELOPED INDEX OF NOT GREATER
10.2.2
THAN 450.
AS PER TABLE 1004.1.2 (F.B.C.) 2004 AREA PER OCCUPANT: 200 SQ/FT. GROSS.
(MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT)
RESIDENCE 4,704 S.F. / 200 = 23 PERSONS
AS PER TABLE 1018.1 (F.B.C.) --> MINIMUM NUMBER OF EXIT OCCUPANCY LOAD PER STORY
(MIN. NUMBER OF EXITS FOR OCCUPANT LOAD) 2 1 -500, PERS.
TYPES OF CONSTRUCTION
AS PER CHAPTER 6 - SECTION 602.3 F.B.C. 2004 TYPE III
AS PER TABLE 503 (F.B.C.) 2004
(ALLOWAMLF HEIGHT AND BUILDING AREAS) -� TYPE III ;GROUP R -3a
AS PER TABLE 601 (F.B.C.) 2004 TYPE III
(FIRE- RESISTANCE RATING REQ. FOR ILDG. ELEMENTS)
AS PER TABLE 602 (F.B.C.) 2004 > TYPE III GROUP "Rb"
(FIRE - RESISTANCE RATING REQ. FOR EXT. WALLS BASED ON FIRE SEP. DISTANCE)
BURGLARY INTRUSION NOTES
1. ALL SINGLE EXTERIOR SWING DOORS SHALL HAVE A LOCK TO BE
KEY OPERATED FROM THE EXTERIOR WITH A MINIMUM OF 6,000
POSSIBLE KEY CHANGES OR LOCKING COMBINATIONS. IF KEY -IN-
THE KNOB LOCK IS USED THERE SHALL BE AN AUXILIARY SINGLE
DEAD BOLT WITH HARDENED BOLT INSERTS.
2. THE ACTIVE LEAF OF PAIRS OF EXTERIOR SWING DOORS SHALL
HAVE SAME LOCKS AS REQUIRED FOR SINGLE EXTERIOR SWING
DOOR. THE INACTIVE LEAF OF THESE PAIR OF DOORS SHALL
HAVE MULTIPLE POINT LOCKS WITH 5/8' MIN. THROW BOLTS
WITH INSERTS.
3. SLIDING GLASS DOORS' SHALL BE PROVIDED WITH SLIDING DOOR
DEAD BOLTS OR A BOLT OR PIN NOT REMOVABLE OR OPERABLE
FOR EXTERIOR, AT THE JAMB, HEAD, SILL OR AT MEETING
MULLIONS. THESE DOORS SHALL BE REINFORCED IN THE STRIKE
AND LOCK ARE TO MAINTAIN BOLT STRENGTH EFFECTIVENESS, IF
NECESSARY, AND SUCH DOORS SHALL HAVE NO SCREWS REMOVABLE
FROM THE OUTSIDE WHICH WOULD FACILITATE READY ENTRY FROM
OUTSIDE.
4. OVERHEAD DOORS SHALL BE PROVIDED WITH MULTIPLE POINT
LOCKS OR BE LOCKED AT MORE THAN ONE POINT WITH HARDENED
BOLT OR BOLTS WITH INSERTS ENGAGING AT LEAST TWO OPPOSITE
POINTS A MIN. 5/8'. OTHER LOCKING DEVICES SMALL NOT BE
REQUIRED WHERE SUCH DOORS ARE CONTROLLED AND LOCKED
BY ELECTRIC POWER.
5. HINGES ON EXTERIOR OUT SWINGING DOORS SHALL HAVE NON
REMOVABLE PINS.
6. JAMS OF ALL EXTERIOR OFFSET TYPE IN SWING DOORS BE
RABBETED, OR OF SIMILAR FABRICATION, TO PREVENT
DEFEATING THE PURPOSE OF THE STRIKE AND THE INTEGRITY OF
LOCKS AND LATCHES.
1. SINGLE SWINGING EXTERIOR DOOR IF WOOD, SHALL BE SOLID
CORE OF NOT LESS THAN 1 1 /6' THICK.
S. GLASS AND EXTERIOR DOORS SHALL COMPLY WITH THE AMERICAN
NATIONAL STANDARDS INSTITUTES- STANDARD 29 -1.1.
9. VISION PANELS IN EXTERIOR DOORS OTHER THAN GLAZING
WITHIN 40' OF THE INSIDE LOCKING ACTIVATING DEVICE OF
LOOSE AND SWINGING DOORS SHALL COMPLY WITH AMERICAN
NATIONAL STANDARDS INSTITUTES- STANDARD 297.1.
10. SLIDING GLASS DOORS AND WINDOWS SHALL BE INSTALLED AND
CONSTRUCTED SO THAT NO PANEL CAN BE LIFTED FROM THE
TRACKS WHEN IN THE LOCKED POSITION AND SO AS TO COMPLY
WITH THE ARCHITECTURAL ALUMINUM MANUFACTURER'S
ASSOCIATION STANDARDS FOR FORCED ENTRY RESISTANCE, AAMA
1303.3.
11. VENTS ON OVERHEAD GARAGE TYPE DOORS SHALL NOT BE
INSTALLED CLOSER THAN 40' TO THE INSIDE LOCK ACTIVATING
DEVICE.
12. SINGLE SWING EXTERIOR AND SWING DOORS CONNECTING LIVING
AREAS WITH GARAGE AREA SHALL BE A MIN. 1 315" THICK,
SOLID CORE, AND SHALL BE SECURED WITH A LATCH AND SINGLE
DEAD BOLT SETS WITH LATCH THROW MIN. OF 1/2' AND BOLTS
HAVING A MIN. OF 1" THROW.
13. FRONT MAIN ENTRANCE DOORS SHALL BE PROVIDED WITH A DOOR
SCOPE OR VISION PANEL.
14. ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF
RESISTING A FORCE OF 300 LBS. APPLIED IN ANY MOVABLE
DIRECTION AND IN ACCORDANCE WITH RESISTANCE STANDARDS
SET FORTH IN METRO CODE/ FLORIDA BUILDING CODE.
l
V y U U `■�7 l
• V y V ` `
i 1• / V V V V I
Y Y V y V 1
V V Y V
uiY• •••VV r ` Y v.
yVVV V
y u •
yU Y V
U14 • YYYYV V uY1 V UyYV G
12901 S.W. 132 AVE
MIAMI, FLORIDA 33186
T. (305) 278 -7776
F. (305) 278 -7473
WWW.BELLONMILANES.COM
AA- 0003505
ARCHITECTURE
LAND PLANNING
INTERIORS
CONSTRUCTION MANAGEMENT
W
U
z
W
Q
W Q
w D
a ac
U) O
L.0 LL
W a
W O
W
D
0
►�
DATE: 02 -13 -01
DRAWN: ALEX P - AP - J.P
CHECKED: AP
PROJ. NO: 2006LB052
1.
2.
3.
BDC: BUILDING DEPT. COMMENTS
CC: COORDINATION CHANGES
AB: AS -BUILT
RAP: REVISION- �FTER ,APPROVAL
cam" n n
- � � • • p'Z � ZZ-�o 7
OPT LqO , BELLON, AIA
""AR -.00i 737
ANGEL MILANES, AIA
AR- 0015845
A -6
OF